Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPECTROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Profiling impurities and degradants of butorphanol tartrate using liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry substructural techniques.

A rapid and systemic strategy based on liquid chromatography/mass spectrometry (LC/MS) profiling and liquid chromatography/tandem mass spectrometry (LC/MS/MS) substructural techniques was utilized to elucidate the degradation products of butorphanol, the active ingredient in stadol NS. This strategy integrates, in a single instrumental approach, analytical HPLC, UV detection, full-scan electrospray mass spectrometry, and tandem mass spectrometry to rapidly and accurately elucidate structures of impurities and degradants. In these studies, several low-level degradation products were observed in long-term storage stability samples of bulk butorphanol. The resulting analytical profile includes information on five degradants including molecular structures, chromatographic behavior, molecular weight, UV data, and MS/MS substructural information. The degradation products formed during long-term storage of butorphanol tartrate included oxidative products proposed as 9-hydroxy-and 9-keto-butorphanol, norbutorphanol, a ring-contraction degradant, and delta 1, 10 a-butorphanol. These methodologies are applicable at any stage of the drug product cycle from discovery through to development. This library of butorphanol degradants provides a foundation for future development work regarding product monitoring, as well as a useful diagnostic tool for new degradation products.

Administration, Inhalation↗

Gas phase reactivity of isomeric arylglycosides towards amines. A chemical ionization mass spectrometry and tandem mass spectrometry study.

Chemical ionization mass spectrometry (MS) and tandem mass spectrometry (MS/MS) experiments have been performed for the structural characterization and isomeric differentiation of two series of C- and O-linked arylglycosides with potential antioxidant activity. Different amines have been used for producing gas phase chemical ionization. Depending on their proton affinity and steric hindrance, adduct ions with different stability are formed. The most stable adducts are produced by ethylamine and they have been extensively structurally characterized by experimental and theoretical approaches. Energy resolved chemical ionization tandem mass spectrometric experiments have allowed unambiguous characterization and differentiation of both the anomers differing at the configuration of the glycosidic C(1) atom, and regio- and structural isomers at extremely low concentrations, typical of mass spectrometry. This study has shown that amine chemical ionization mass spectrometry and MS/MS are powerful and versatile tools for the structural characterization of arylglycosides.

Amines↗

Characterization of noncovalent complexes of antimalarial agents of the artemisinin-type and FE(III)-heme by electrospray mass spectrometry and collisional activation tandem mass spectrometry.

In this study, we demonstrate, using electrospray ionization mass spectrometry (ESI-MS) and collision-induced dissociation tandem mass spectrometry (ESI-MS/CID/MS), that stable noncovalent complexes can be formed between Fe(III)-heme and antimalarial agents, i.e., quinine, artemisinin, and the artemisinin derivatives, dihydroartemisinin, alpha- and beta-artemether, and beta-arteether. Differences in the binding behavior of the examined drugs with Fe(III)-heme and the stability of the drug-heme complexes are demonstrated. The results show that all tested antimalarial agents form a drug-heme complex with a 1:1 stoichiometry but that quinine also results in a second complex with the heme dimer. ESI-MS performed on mixtures of pairs of various antimalarial agents with heme indicate that quinine binds preferentially to Fe(III)-heme, while ESI-MS/CID/MS shows that the quinine-heme complex is nearly two times more stable than the complexes formed between heme and artemisinin or its derivatives. Moreover, it is found that dihydroartemisinin, the active metabolite of the artemisinin-type drugs in vivo, results in a Na(+)-containing heme-drug complex, which is as stable as the heme-quinine complex. The efficiency of drug-heme binding of artemisinin derivatives is generally lower and the decomposition under CID higher compared with quinine, but these parameters are within the same order of magnitude. These results suggest that the efficiency of antimalarial agents of the artemisinin-type to form noncovalent complexes with Fe(III)-heme is comparable with that of the traditional antimalarial agent, quinine. Our study illustrates that electrospray ionization mass spectrometry and collision-induced dissociation tandem mass spectrometry are suitable tools to probe noncovalent interactions between heme and antimalarial agents. The results obtained provide insights into the underlying molecular modes of action of the traditional antimalarial agent quinine and of the antimalarials of the artemisinin-type which are currently used to treat severe or multidrug-resistant malaria.

Antimalarials↗

Determination of capsaicin, dihydrocapsaicin, and nonivamide in self-defense weapons by liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the analysis of capsaicin, dihydrocapsaicin, and nonivamide in pepper spray products have been developed. Chromatographic separation of the capsaicinoid analogues was achieved using a reversed-phase HPLC column and a stepwise gradient of methanol and distilled water containing 0.1% (v/v) formic acid. Identification and quantification of the capsaicinoids was achieved by electrospray ionization single-stage mass spectrometry monitoring the protonated molecules of the internal standard (m/z 280), capsaicin (m/z 306), dihydrocapsaicin (m/z 308), and nonivamide (m/z 294) or by tandem mass spectrometry monitoring the appropriate precursor-to-product-ion transitions. The plot of concentration versus peak area ratio was linear over the range of 10-750 ng/ml using LC-MS and 10-500 ng/ml using LC-MS-MS. However, to accurately quantify the capsaicinoids in the pepper spray products calibration curves between 10 and 1000 ng were constructed and fit using a weighted quadratic equation. Using the quadratic curve, the accuracy of the assay ranged from 91 to 102% for all analytes. The intra-assay precision (RSD) for capsaicin was 2% at 25 ng/ml, 10% at 500 ng/ml, and 3% at 800 ng/ml. The inter-assay precision (RSD) for capsaicin was 6% at 25 ng/ml, 6% at 500 ng/ml, and 9% at 800 ng/ml. Similar values for inter- and intra-assay precision were experimentally obtained for both dihydrocapsaicin and nonivamide. The analysis of selected pepper spray products demonstrated that the capsaicinoid concentration in the products ranged from 0.7 to 40.5 microg/microl.

Capsaicin↗

Hyphenated techniques in anticancer drug monitoring. II. Liquid chromatography-mass spectrometry and capillary electrophoresis-mass spectrometry.

High-performance liquid chromatography has become the separation technique of choice for the monitoring of generally thermolabile anticancer agents. With the introduction of electrospray mass spectrometry, the coupling of liquid chromatogaphy and mass spectrometry has opened the way to widely and routinely applied anticancer drug monitoring. Real-time metabolism versus degradation can now be distinguished, since derivatization is no longer obligatory. This is important for the monitoring of the anabolic and catabolic pathways of the same agent, such as 5-fluorouracil. Detection limits almost equal to those obtained with capillary gas chromatography-mass spectrometry are realistic with the latest generation of mass spectrometers, enabling quantitative analysis of various anticancer agents and their metabolites down to the low ng/ml level. Furthermore, sample clean-up and chromatography can be downscaled markedly using the latest column technologies, such as the generally applied 10 cm x 2.8 mm I.D. RP 18 columns. The coupling of capillary electrophoresis to mass spectrometry is today far from a routine application in anticancer drug monitoring. Nevertheless, interesting applications have been reported and are selected for the present review.

Antineoplastic Agents↗

Studies of cisplatin and hemoglobin interactions using nanospray mass spectrometry and liquid chromatography with inductively-coupled plasma mass spectrometry.

Interactions of cisplatin with hemoglobin (Hb) were studied using both nanoelectrospray mass spectrometry (nanoESI-MS) and a combination of size exclusion high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICPMS). Size exclusion HPLC separation of free and protein-bound cisplatin followed by simultaneous monitoring of 195Pt and 57Fe demonstrated the presence of Hb-bound Pt complexes. Nanospray quadrupole time-of-flight mass spectrometry studies of the Hb-cisplatin complexes further demonstrated the specific binding of cisplatin to the alpha-chain, heme-alpha, beta-chain, and heme-beta units of hemoglobin. Accurate mass measurements and tandem mass spectrometry information confirmed the Hb-cisplatin complexes. The formation of Hb-cisplatin complexes was observed at the sub-microM to microM concentration levels of cisplatin, which are relevant to clinical levels. These findings and the techniques developed for cisplatin-Hb interaction studies are useful for understanding of drug-protein interactions.

Antineoplastic Agents↗

Assessment of the amount of body water in the Red Knot (Calidris canutus): an evaluation of the principle of isotope dilution with 2H, (17)O, and (18)O as measured with laser spectrometry and isotope ratio mass spectrometry.

We have used the isotope dilution technique to study changes in the body composition of a migratory shorebird species (Red Knot, Calidris canutus) through an assessment of the amount of body water in it. Birds were quantitatively injected with a dose of water with elevated concentrations of 2H, (17)O, and (18)O. Thereafter, blood samples were taken and distilled. The resulting water samples were analysed using an isotope ratio mass spectrometry (for 2H and (18)O only) and a stable isotope ratio infrared laser spectrometry (2H, (17)O, and (18)O) to yield estimates of the amount of body water in the birds, which in turn could be correlated to the amount of body fat. Here, we validate laser spectrometry against mass spectrometry and show that all three isotopes may be used for body water determinations. This opens the way to the extension of the doubly labelled water method, used for the determination of energy expenditure, to a triply labelled water method, incorporating an evaporative water loss correction on a subject-by-subject basis or, alternatively, the reduction of the analytical errors by statistically combining the (17)O and (18)O measurements.

Animals↗

Investigation of the tris(trimethoxyphenyl)phosphonium acetyl charged derivatives of peptides by electrospray ionization mass spectrometry and tandem mass spectrometry.

Charged derivatives of peptides are useful in obtaining simpler collision-activated dissociation (CAD) mass spectra. An N-terminal charge-derivatizing reagent capable of reacting with picomole levels of peptide has been recently reported (Huang et al. Anal. Chem. 1997, 69, 137-144) in the contexts of analyses by fast atom bombardment (FAB) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Electrospray ionization (ESI) mass spectrometric investigation of these tris(trimethoxyphenylphosphonium) acetyl derivatives are described in this article, including studies by in-source fragmentation (ISF) and tandem mass spectrometry (MS/MS). Results from ISF are compared with those from MS/MS. Similarities and differences between ESI-ISF, MALDI-post-source decay (PSD), and FAB-CAD data are presented. Differences in fragmentation of these charged derivatives in the triple quadrupole and ion trap mass spectrometers also are discussed. Application of this derivatizing procedure to tryptic digests and subsequent analysis by liquid chromatography-mass spectrometry is also shown.

Amino Acid Sequence↗

Gas chromatography/electron impact mass spectrometry, fast atom bombardment mass spectrometry, mass-analyzed ion kinetic energy spectroscopy and B/E linked scan analysis of triaryl phosphates and triethylene glycol fatty acid esters.

Tris(isopropylphenyl/phenyl) phosphates and triethylene glycol dicaprate/caprylate mixtures of typical industrial compositions have been analyzed by fast atom bombardment (FAB) mass spectrometry, FAB collisional activation (CA) mass-analyzed ion kinetic energy spectroscopy and FAB/electron impact (EI) CA B/E linked scans. Data obtained by these state-of-the-art methodologies are compared qualitatively and semi-quantitatively with those provided by classical gas chromatography (GC)/EI MS. To identify the plasticizers in cases of suspected contamination, GC/EI MS still appears to be the method of choice whenever ultimate sensitivity and specificity are needed. In cases where these requirements are less demanding, FAB mass spectrometry and FAB tandem mass spectrometry may be sufficient and more convenient.

Chemical Phenomena↗

Investigation of the interaction between enzyme and inhibitor by the combination of chemical modification, electrospray ionization mass spectrometry and frit-fast atom bombardment liquid chromatography/mass spectrometry.

The interaction between enzyme and its inhibitor, hen egg-white lysozyme and tri-N-acetylglucosamine (NAG3), was studied by the combination of chemical modification, enzymatic digestion, electrospray ionization mass spectrometry and frit-fast atom bombardment liquid chromatography/mass spectrometry. Chemical modification of amino groups, carboxyl groups, and indole groups was carried out independently. In the absence of NAG3, the carboxyl group in Asp 101 was modified by glycinamidation, and the indole group in Trp 62 was modified by Koshland reagent. In the presence of NAG3, the degree of modification of Asp 101 and Trp 62 decreased. It is suggested that Asp 101 and Trp 62 are involved in the interaction with NAG3. The result is consistent with the one obtained by x-ray crystallography. It is indicated that the combination of chemical modification and mass spectrometry may be effective for the investigation of the binding reaction of enzyme to inhibitor and of protein-protein interaction.

Amines↗

Analysis of amphetamines and fentanyls by atmospheric pressure desorption/ionization on silicon mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry and its application to forensic analysis of drug seizures.

The suitability of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS) and matrix-assisted laser desorption ionization mass spectrometry (AP-MALDI-MS) for the identification of amphetamines and fentanyls in forensic samples was studied. With both ionization techniques, the mass spectra recorded showed abundant protonated molecules, and the background did not disturb the analysis. The use of tandem mass spectrometry (MS/MS) allowed unambiguous identification of the amphetamines and fentanyls. AP-DIOS-MS/MS and AP-MALDI-MS/MS were also successfully applied to the identification of authentic compounds from drug seizures. Common diluents and tablet materials did not disturb the analysis and compounds were unequivocally identified. The limits of detection (LODs) for amphetamines and fentanyls with AP-DIOS-MS/MS were 1-3 pmol, indicating excellent sensitivity of the method. The LODs with AP-MALDI-MS/MS were about 5-10 times higher.

Amphetamines↗

Large-scale identification of proteins in human salivary proteome by liquid chromatography/mass spectrometry and two-dimensional gel electrophoresis-mass spectrometry.

Human saliva contains a large number of proteins and peptides (salivary proteome) that help maintain homeostasis in the oral cavity. Global analysis of human salivary proteome is important for understanding oral health and disease pathogenesis. In this study, large-scale identification of salivary proteins was demonstrated by using shotgun proteomics and two-dimensinal gel electrophoresis-mass spectrometry (2-DE-MS). For the shotgun approach, whole saliva proteins were prefractionated according to molecular weight. The smallest fraction, presumably containing salivary peptides, was directly separated by capillary liquid chromatography (LC). However, the large protein fractions were digested into peptides for subsequent LC separation. Separated peptides were analyzed by on-line electrospray tandem mass spectrometry (MS/MS) using a quadrupole-time of flight mass spectrometer, and the obtained spectra were automatically processed to search human protein sequence database for protein identification. Additionally, 2-DE was used to map out the proteins in whole saliva. Protein spots 105 in number were excised and in-gel digested; and the resulting peptide fragments were measured by matrix-assisted laser desorption/ionization-mass spectrometry and sequenced by LC-MS/MS for protein identification. In total, we cataloged 309 proteins from human whole saliva by using these two proteomic approaches.

Chromatography, Liquid↗

A novel approach for identification and measurement of hemoglobin adducts with 1,2,3,4-diepoxybutane by liquid chromatography/electrospray ionisation mass spectrometry and matrix-assisted laser desorption/ionisation tandem mass spectrometry.

The structural characterisation of the adducts formed by in vitro interaction of hemoglobin (Hb) with 1,2,3,4-diepoxybutane (DEB), the most reactive 1,3-butadiene (BD) metabolite, was obtained by liquid chromatography/electrospray ionisation mass spectrometry (LC/ES-MS) analysis of modified tryptic peptides of human hemoglobin chains. The reactive sites of human hemoglobin towards DEB and its hydroxylated derivatives (trihydroxybutyl (THB)-derivatives) were identified through the characterisation of alkylated tryptic peptides by matrix-assisted laser desorption/ionisation tandem mass spectrometry (MALDI-MS/MS). Based on this characterisation, a procedure was set up to measure the Hb-adducts of THB-derivatives by isotope dilution mass spectrometry with the use of a deuterated peptide standard. The results obtained here could permit optimisation of molecular dosimetry of BD-adducts, and extension of the analysis to the biological monitoring of occupational exposure to butadiene.

Alkylation↗

Determination of the acylcoenzyme A cholesterol acyltransferase inhibitor 447C88 in plasma using gas chromatography-mass spectrometry and liquid chromatography atmospheric pressure chemical ionisation tandem mass spectrometry.

Two mass spectrometry-based methods are described for the determination of 447C88 (I), a novel inhibitor of acylcoenzyme A cholesterol acyltransferase (ACAT), in rat, dog and human plasma. The first method uses gas chromatography-mass spectrometry (GC-MS) with electron ionisation and selected-ion monitoring. The method employs solid-phase extraction of I from plasma and requires alkylation of I using iodoethane. The second method uses liquid chromatography-tandem mass spectrometry (LC-MS-MS) with atmospheric-pressure chemical-ionisation and selected-reaction monitoring. The LC-MS-MS method uses a simplified version of the extraction procedure used for GC-MS and does not require derivatisation of I. While both methods provide the necessary limit of quantitation of 0.5 ng/ml in human, dog and rat plasma with the required precision and accuracy, the LC-MS-MS assay offers increased sensitivity, selectivity and speed over the GC-MS assay. This allows a same day turn round of results for in excess of 100 samples, including sample preparation and data acquisition and processing.

Alkylation↗

Analysis of protein phosphorylation by capillary liquid chromatography coupled to element mass spectrometry with 31P detection and to electrospray mass spectrometry.

A method for phosphopeptide identification by capillary liquid chromatography (muLC) interfaced alternatively to element mass spectrometry (inductively coupled plasma mass spectrometry, ICPMS) and to electrospray ionization mass spectrometry (ESI-MS) is described. ICPMS is used for 31P detection and ESI-MS provides the corresponding molecular weight information. Alignment of the two separate muLC runs is performed using the baseline distortion at the elution front, which shows up in both muLC-ICPMS and muLC-ESI-MS. Both a quadrupole and a magnetic sector field mass analyzer were used in combination with ICP. The detection limit achieved for the muLC-ICP-HRMS runs is approximately 0.1 pmol of phosphopeptide injected. Without any further precautions, contamination by phosphate-containing compounds at this level was found to be uncritical. The method is demonstrated for the analysis of a complex mixture of synthetic phosphopeptides and a set of tryptic digests of three phosphoproteins. These include beta-casein, activated human MAP kinase ERK1, and protein kinase A catalytic subunit. The tryptic phosphopeptides of these proteins could all be detected and identified by our new strategy. Analysis of three fractions of protein kinase A catalytic subunit with different phosphorylation status gives direct access to the order in which the phosphorylation of the four phosphorylation sites occurs. The two most important aspects of using muLC-ICPMS with 31P detection for phosphopeptide identification are (i) that a high selectivity is achieved and (ii) that the signal intensity is independent of the chemical form of phosphorus and directly proportional to the molar amount of 31P in the muLC eluate. Thus, muLC-ICPMS with 31P detection is introduced as a new, robust, and specific method in phosphoproteomics.

Amino Acid Sequence↗

Coupling capillary electrophoresis and high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of complex lipopolysaccharides.

High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technology for atmospheric pressure, room temperature separation of gas-phase ions. The FAIMS system acts as an ion filter that can continuously transmit one type of ion, independent of mass-to-charge ratio (m/z). Capillary electrophoresis-electrospray mass spectrometry (CE-MS) has been extensively used for the analysis of complex bacterial lipopolysaccharides (LPS). The coupling of FAIMS to CE-MS provides a sensitive technique for the characterization of these complex glycolipids, permitting the separation of trace-level LPS oligosaccharide glycoforms for subsequent structural characterization using tandem mass spectrometry. This was demonstrated for LPS from nontypeable Haemophilus influenzae strain 375 following O-deacylation with anhydrous hydrazine. This strain of H. influenzae can express a triheptosyl-containing glycoform to which four hexose residues are linked forming the outer-core region of the molecule. This has been referred to as the Hex4 glycoform. Glycoforms have been identified which differ in the number of phosphoethanolamine substituents in the inner-core. With the use of CE-FAIMS, isomeric Hex4 glycoforms containing two PEtn groups were separated and characterized by MS/MS. FAIMS provided a significant reduction in mass spectral noise, leading to improved detection limits ( approximately 70 amol of the major glycoform). The extracted mass spectrum showed that the apparent noise was virtually eliminated. In addition to the reduction of chemical background, the ion current was increased by as much as 7.5 times as a result of the atmospheric pressure ion-focusing effect provided by the FAIMS system. The linearity of response of the CE-FAIMS-MS system was also studied. The calibration curve is linear for approximately 3 orders of magnitude, over a range of 40 pg/microL to 10 ng/microL.

Carbohydrate Sequence↗

Negative ion chemical ionization gas chromatography-mass spectrometry and atmospheric pressure chemical ionization liquid chromatography-mass spectrometry of low-dosed and/or polar drugs in plasma.

In clinical and forensic toxicology, doping control, and therapeutic drug monitoring, specific and sensitive detection and precise quantification of xenobiotics in biosamples are great challenges. Today, mass spectrometry techniques, coupled with gas chromatography or liquid chromatography, are the most powerful methods in analytic toxicology. The pros and cons of electron ionization (EI) and negative ion chemical ionization (NICI) gas chromatography-mass spectrometry (GC-MS) and of atmospheric pressure chemical ionization liquid chromatography-mass spectrometry (APCI-LC-MS) are described for determination of the low-dosed benzodiazepine flunitrazepam and its 7-amino and its nor-metabolite in plasma. In addition, application of NICI-GC-MS is described for sensitive chiral determination of amphetamine derivatives in plasma and application of APCI-LC-MS for screening, library-assisted identification, and validated quantification of oral antidiabetics and for validated quantification of the neuroleptic risperidone and its 9-hydroxy metabolite. These examples show that NICI-GC-MS and LC-MS are powerful tools for determination of low-dosed and/or rather polar drugs or poisons, thus becoming indispensable supplements to classic EI-GC-MS in clinical and forensic toxicology as well as in doping control.

Amphetamine↗

Preliminary investigation of glycosylated proteins by capillary electrophoresis and capillary electrophoresis/mass spectrometry using electrospray ionization and by matrix-assisted laser desorption ionization/time-to-flight mass spectrometry.

In recent years, the biotechnological industry has emerged as the major source of new human therapeutic proteins. Although the great majority of these occur naturally as glycoproteins, it has been observed that glycosylation of the recombinantly produced proteins could be fundamental for their in vivo activity (e.g. tissue plasminogen activator, erythropoietin) or, on the contrary, insignificant (e.g. interleukin-1 receptor antagonist, gamma-interferon, granulocyte macrophage-colony-stimulating factor). The inherent heterogeneity of these complex biomolecules presents an exciting challenge in the analytical field for both their structural analysis and the development of suitable analytical methods to guarantee consistency of their production. Owing to this ever increasing therapeutic interest in proteins and glycoproteins, this paper compares the information provided by different analytical techniques (i.e. high-performance liquid chromatography, sodium dodecyl sulphate polyacrylamide gel electrophoresis, capillary electrophoresis, capillary electrophoresis/electrospray ionization mass spectrometry, matrix-assisted laser desorption/ionization time-of flight mass spectrometry and high-performance liquid chromatography/matrix-assisted laser desorption/ionization time-of flight mass spectrometry when used for the analysis of proteins and glycoproteins. For the sake of simplicity, reference standard proteins and glycoproteins were used as samples.

Chromatography, High Pressure Liquid↗