Search PubMedSearch

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

[Analysis of solutions for parenteral use under field conditions].

Methods for determination of relative density, osmolarity, then refractometry, polarymetry and conductometry as simple methods suitable for work under field conditions have been applied for the quality control of the following solutions for infusion and injections: glucose, mannitol, sodium chloride, sodium hydrogencarbonate, magnesium sulphate and potassium chloride. The results obtained in the analysis of preparations have shown the advantage of refractometry.

Infusions, Parenteral

Active and monomeric human red cell glucose transporter after high performance molecular-sieve chromatography in the presence of octyl glucoside and phosphatidylserine or phosphatidylcholine.

The human red cell glucose transporter (Glut 1) was purified by ion-exchange chromatography in the presence of octyl glucoside. The state of association of the protein was studied, and the transport activity was determined after exchange of copurified membrane lipids for phosphatidylserine (PS) or phosphatidylcholine (PC). The purpose was to analyze the Glut 1 preparation for homogeneity and activity prior to attempts at crystallization. Analyses by high performance molecular-sieve chromatography showed that the Glut 1 was monomeric immediately after the ion-exchange purification: the Mr of the Glut 1 polypeptide was estimated to be 49,000 +/- 6000 by TSKgel G3000SW chromatography monitored by low-angle laser light-scattering photometry, differential refractometry and UV photometry. This required determination of the absorption coefficient of the Glut 1, which was measured to be 1.13 +/- 0.03 ml mg-1 cm-1 at 280 nm, referring to the polypeptide concentration. The Mr value is consistent with the cDNA-deduced Mr 54,117 of the very similar HepG2 glucose transporter polypeptide. At 2 degrees C, pH 7 and an ionic strength of 0.06 M, the Glut 1 associated gradually during three days to form oligomers. These formed much more rapidly at room temperature or at high ionic strength. Freshly prepared Glut 1 retained high activity after separation from membrane lipids on a TSKgel G3000SW column in the presence of 40 mM octyl glucoside and 1 mM PS or PC. In contrast, most of the activity was lost when the membrane lipids were separated from the protein in the absence of eluent lipids. The presence of a phospholipid was thus essential for retention of high activity of the Glut 1 in octyl glucoside and PC was nearly as effective as PS.

Chromatography, Gel

Determination of cholesterol and cortisone absorption in polyurethane. I. Methodology using size-exclusion chromatography and dual detection.

A size-exclusion chromatographic method is described for measuring the absorption of the steroid-based lipids cholesterol and cortisone into Pellethane 2363, a polyurethane used in biomedical implants. The method uses refractometry and ultraviolet diode-array detection, with tetrahydrofuran as the mobile phase. Using an injection volume of 150 microliters, the lower limit of accurate measurement for cholesterol (refractive index detection) was 6 micrograms/ml with a lower limit of detection, based on a 2:1 signal-to-noise ratio, of 0.15 micrograms (1 microgram/ml). For cortisone (ultraviolet detection), the lower accurate limit was 0.6 micrograms/ml with a lower limit of 0.015 micrograms (0.1 micrograms/ml). The results show that after 44 h, 2037 micrograms/g cholesterol and 3131 micrograms/g cortisone were absorbed by the polyurethane. The method eliminates extensive sample manipulation and is sensitive to low levels of lipid in the presence of a high-molecular-mass synthetic polymer.

Absorption

An automatic interference refractometer.

Interference refractometry is a well-established method of determining the concentration of anaesthetic agents in gas mixtures. A photo-electric detector system has been fitted to a small portable, direct-reading interference refractometer to display automatically the concentration of the agent being measured. The design of the instrument is described and two possible methods of information display are suggested.

Anesthetics

The clinical refractometer: a useful tool for the determination of specific gravity and osmolality in canine urine.

For the determination of specific gravity of canine urine the urinometer is often used. An alternative method is based on refractometry. Both methods were compared and a table for converting refractometer values to urinometer values is given. The refractometer was also compared with an osmometer. A linear relation was found between the readings of both instruments. The results clearly indicate that the refractometric method is very suitable for the small animal practitioner. The instrument appears to be a good alternative for both the urinometer and the osmometer.

Animals

A human model of allergic conjunctivitis.

Using the method of refractometry to measure protein concentration in tears, a simple model was developed to evaluate the allergic response in humans. Timothy grass pollen was instilled into the cul de sac of a human subject, and the protein content of the subject's tears was sampled every 15 minutes for three hours. Once the time course of this experiment was predictable, various eye medications were instilled into the subject's eye 30 minutes after allergic challenge. It was noted that 1.0% and 0.1% prednisolone, each combined with 0.12% phenylephrine hydrochloride, as well as 1% epinephryl borate eye drops, produced an almost immediate return to normal of tear protein levels, whereas 1.0% medrysone, 0.1% fluorometholone, 1.0% prednisolone, and 0.12% prednisolone had less pronounced effects on reduction of elevated tear protein concentration.

Administration, Topical

Outflow facility and its response to pilocarpine decline in aging rhesus monkeys.

Refractive error and total outflow facility were determined by Hartinger coincidence refractometry and two-level constant-pressure perfusion, respectively, in 17 rhesus monkeys, aged 5 to 29 years. Maximum accommodative response to corneal (iontophoretic) carbachol hydrochloride, baseline outflow facility, and the facility response to strong but submaximal intracameral doses of pilocarpine hydrochloride all declined with age. The correlation between accommodative response to carbachol and facility response to pilocarpine was slightly stronger than that between age and facility response. Since the ciliary muscle plays a major role in controlling both outflow facility and accommodation, and since histologic and videographic techniques demonstrate an age-related decline in rhesus ciliary muscle excursion induced by topical pilocarpine or electrical stimulation of the Edinger-Westphal nucleus, the present data support the hypothesis that an age-related decline in ciliary muscle mobility is associated, perhaps causally, with an age-related decline in facility and facility responsiveness to cholinergic drugs.

Accommodation, Ocular

Lamellar keratoplasty in keratoconus.

The authors present the results of 11 keratoplasties in cases of keratoconus, comparing the visual acuity and the ocular refraction before and after the operation (ophtalmometry, objective and subjective refractometry). The statistical data indicate a meaningful flattening of the corneal curvature (12.84 dpt average) and a mean reduction of the myopia for 8.227 dpt. In fact, the basic regular astigmatism of the cornea had not been altered. The mean visual acuity was 0.68 (with an improvement of 0.495). No further damage of acuity had been observed. After 10 to 69 months a medical checkup revealed transparent grafts in five cases; four presented small maculae; one, thin folds of Descemet's membrane. Based on the authors' experience and on the literature, the paper recommends lamellar keratoplasty in cases of keratoconus, the surgeon must choose the appropriate moment in the course of the development of this disease.

Adult

Functional morphology of accommodation in the raccoon.

The raccoon (Procyon lotor) is a small carnivore which eats in the upright position, using hand- and finger-like front paws and digits to wash, hold and examine its food at close range. These anatomic and behavioral characteristics prompted structural and functional studies of the accommodative capability of this species. By light and electron microscopy, we observed a prominent ciliary smooth muscle and zonular apparatus. When stimulated by carbachol or pilocarpine, the muscle and zonular apparatus exhibited a shift from longitudinal to reticular or circular orientation of some ciliary muscle bundles, anterior movement of the muscle as a whole, and more oblique crossing of the zonular fiber bundles in the zonular plexus. Maximum carbachol-induced accommodative amplitude measured by coincidence refractometry ranged from 3 to 19 diopters in these 1 to 9 yr old animals, with no definite age-accommodation relationship. A-scan ultrasonographic biometry showed that during accommodation the lens thickened very little, if at all, but moved anteriorly, while the apparent cornea to retina distance increased slightly. The raccoon thus exhibits the greatest accommodative capability of any non-primate terrestrial mammal so far studied.

Accommodation, Ocular

Characterization of functionally distinct lymphoid and myeloid cells from human blood and bone marrow. I. Separation by a buoyant density gradient technique.

A buoyant density gradient procedure for mammalian cell separation is described. Gradients of Ficoll and Hypaque in balanced salt solution were used in a zonal rotor to separate distinct leukocyte populations from human peripheral blood and bone marrow. This method possesses the advantages of uniform osmolarity, density determination by refractometry, ease of preparation of gradient solutions, large sample capacity, and low viscosity with consequent ease of sterilization. Granulocyte-monocyte colony-forming units (CFU-C) from blood and bone marrow banded as a homogeneous peak with a density of 1.056 g cm-3 on steep gradients. Recovery of CFU-C was 36% with a 7- to 9-fold enrichment on shallow gradients. Both fractionated and unfractionated peripheral blood cells were stimulated by phytohemagglutinin (PHA), Concanavalin A (Con A), and allogeneic lymphocytes. In contrast, cells from unfractionated bone marrow and cells from the light density fraction of marrow were inhibited by Con A and responded variably to PHA.

Blood Cells

The magnitude of longitudinal chromatic aberration of the human eye between 458 and 633 nm.

The longitudinal chromatic aberration (LCA) of the human eye was determined between wavelengths 458 and 633 nm for ten observers by incorporating Argon and Helium-Neon Lasers into a Badal optometer system such that tonic (or "dark focus") resting positions of accommodation could be measured under darkroom conditions. A mean chromatic range of 1.87 D was found between 488 and 633 nm. The range increased slightly to 1.91 D when the experiment was repeated under cycloplegia on a subset of three subjects. Additional wavelengths (458 and 476 nm) for a further subset (four subjects) increased the range to 2.65 D. This magnitude of LCA would support recent predictions based on Abbe and Pulfrich refractometry analyses of the dispersion of the human crystalline lens and ocular media.

Accommodation, Ocular

A comparison of three methods for determining the concentration of rat urine.

The concentrations of 78 rat urines were compared using osmometry, refractometry and test strips for specific gravity. Test strip specific gravity values are a guide to urine concentration; where small changes of urine concentration are expected, the test strips should not be a replacement for more accurate methods such as osmometry.

Animals

A field lab method to determine urine concentration in small mammals.

1. The concentrations of 136 urine samples from four species of small mammals were compared using osmometry, refractometry and a colorimetric test for urea concentration. 2. To obtain a wide range of concentrations (430-3950 mOsm/kg), urine samples were collected under normal and dehydration conditions. 3. Regression analyses of paired values indicate that measurements of total solids concentration (refractometric method) permit evaluations of urine osmolality and estimations of the concentration of urea with a high degree of confidence.

Animals

Water-soluble proteins do not bind octyl glucoside as judged by molecular sieve chromatographic techniques.

It is well known that the non-ionic detergent octyl glucoside (1-O-n-octyl-beta-D-glucopyranoside) solubilizes biological membrane components. It forms complexes with membrane-spanning proteins by hydrophobic interactions and it forms mixed micelles with membrane lipids. In contrast, non-ionic detergents usually do not bind to water-soluble proteins. According to a recent report, substantial and cooperative binding of octyl glucoside to several water-soluble proteins does occur near the critical micelle concentration. However, data have been obtained that contradict this report. No decrease was found in the elution volumes of five water-soluble proteins on molecular sieve chromatography on two Superose columns in tandem when 35 mM octyl glucoside was included in the eluent. No binding of the detergent to these proteins was observed at 20 or 22.5 mM octyl glucoside on molecular sieve chromatography on a TSK SW guard column as determined by differential refractometry and UV spectrophotometry of the proteins in the absence or presence of octyl glucoside. The experiments were done with the same buffer system and with six of the proteins used in the reported study. It is concluded that, as expected, there is no binding of octyl glucoside to water-soluble proteins above the detection limit (0.1 g detergent/g protein) of the refractometric method. The binding of, on average, 1.3 +/- 0.2 g of detergent per gram of water-soluble protein that was observed at 20 mM octyl glucoside in the reported study is not consistent with the present results.

Chromatography, Gel

Interaction of ribonuclease A with aqueous 2-methyl-2,4-pentanediol at pH 5.8.

The interactions between ribonuclease A and solvent components in aqueous 2-methyl-2,4-pentanediol (MPD) have been investigated by differential refractometry and light scattering at pH 5.8, i.e., conditions similar to those used to crystallize the protein from this solvent system. Application of multicomponent thermodynamic theory shows that, at all solvent compositions up to 50% (v/v) MPD, the protein is preferentially hydrated; i.e., addition of ribonuclease to the mixed solvent leads to an increase in the chemical potential of MPD. This unfavorable thermodynamic interaction leads to phase separation, probably caused by local salting out of the MPD by the charges on the surface of the protein molecule. A parallel examination by circular dichroism (CD) has shown that the CD spectrum of ribonuclease in 50% MPD is indistinguishable from that in dilute buffer.

Animals

Proton-dependent dissociation equilibrium of hemoglobin. 1. A 700-nanometer light-scattering study on horse methemoglobin in the pH range 4.8 to 7.2.

The effect of proton concentration upon the subunit dissociation of horse methemoglobin has been investigated at two ionic strengths by light scattering photometry at 700 nm. Differential refractometry revealed a slight but systematic decrease of the specific refractive index increment with decreasing protein concentration for solutions in dialytic equilibrium with the solvent. In the pH range 4.8-7.2 the dissociation can be described by a simple equilibrium between tetramers and dimers. The dissociation constant Kd of the met derivative is found to be very similar to those of the O2- and CO-ligated states. From the slope of a plot of log Kd vs. pH, the number of protons bound is n = 1.3 +/- 0.1 resulting from an increase in the pK values of two groups upon dissociation. These two groups must be identical because the dissociation is symmetrical.

Animals

[Eliminating reflection of intraocular lenses].

Reflections on the refractive surfaces of intraocular lenses can be a nuisance when performing retinoscopy or refractometry. Some patients with IOLs also see reflections which disturb their vision. This article examines the conditions for coating IOLs. It also explains why conventional coating methods cannot be used for IOLs.

Humans

A simple field test for assessing salt balance in heat-stressed miners.

A simple colorimetric test for urinary chloride (Fantus test) corrected for urine specific gravity (measured by refractometry) enabled 24-hour urinary sodium excretion rates to be predicted accurately from a single spot sample of urine. In 29 acclimatized miners working in an environment in excess of 40 degrees C, salt-conserving mechanisms, involving renin and aldosterone, were not active until the urinary sodium excretion rate fell below 50 mmol/24 h. A predicted sodium excretion rate greater than 50 mmol/24 h indicates that dietary sodium supplementation is not necessary.

Adult