Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radiometric Dating”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3Linked to original sources

Direct radiocarbon dates for Vindija G(1) and Velika Pecína late Pleistocene hominid remains.

New accelerator mass spectrometry radiocarbon dates taken directly on human remains from the Late Pleistocene sites of Vindija and Velika Pecina in the Hrvatsko Zagorje of Croatia are presented. Hominid specimens from both sites have played critical roles in the development of current perspectives on modern human evolutionary emergence in Europe. Dates of approximately 28 thousand years (ka) before the present (B.P.) and approximately 29 ka B.P. for two specimens from Vindija G(1) establish them as the most recent dated Neandertals in the Eurasian range of these archaic humans. The human frontal bone from Velika Pecina, generally considered one of the earliest representatives of modern humans in Europe, dated to approximately 5 ka B.P., rendering it no longer pertinent to discussions of modern human origins. Apart from invalidating the only radiometrically based example of temporal overlap between late Neandertal and early modern human fossil remains from within any region of Europe, these dates raise the question of when early modern humans first dispersed into Europe and have implications for the nature and geographic patterning of biological and cultural interactions between these populations and the Neandertals.

Animals↗

Suggested protocol for collecting, handling and preparing peat cores and peat samples for physical, chemical, mineralogical and isotopic analyses.

For detailed reconstructions of atmospheric metal deposition using peat cores from bogs, a comprehensive protocol for working with peat cores is proposed. The first step is to locate and determine suitable sampling sites in accordance with the principal goal of the study, the period of time of interest and the precision required. Using the state of the art procedures and field equipment, peat cores are collected in such a way as to provide high quality records for paleoenvironmental study. Pertinent field observations gathered during the fieldwork are recorded in a field report. Cores are kept frozen at -18 degree C until they can be prepared in the laboratory. Frozen peat cores are precisely cut into 1 cm slices using a stainless steel band saw with stainless steel blades. The outside edges of each slice are removed using a titanium knife to avoid any possible contamination which might have occurred during the sampling and handling stage. Each slice is split, with one-half kept frozen for future studies (archived), and the other half further subdivided for physical, chemical, and mineralogical analyses. Physical parameters such as ash and water contents, the bulk density and the degree of decomposition of the peat are determined using established methods. A subsample is dried overnight at 105 degree C in a drying oven and milled in a centrifugal mill with titanium sieve. Prior to any expensive and time consuming chemical procedures and analyses, the resulting powdered samples, after manual homogenisation, are measured for more than twenty-two major and trace elements using non-destructive X-Ray fluorescence (XRF) methods. This approach provides lots of valuable geochemical data which documents the natural geochemical processes which occur in the peat profiles and their possible effect on the trace metal profiles. The development, evaluation and use of peat cores from bogs as archives of high-resolution records of atmospheric deposition of mineral dust and trace elements have led to the development of many analytical procedures which now permit the measurement of a wide range of elements in peat samples such as lead and lead isotope ratios, mercury, arsenic, antimony, silver, molybdenum, thorium, uranium, rare earth elements. Radiometric methods (the carbon bomb pulse of (14)C, (210)Pb and conventional (14)C dating) are combined to allow reliable age-depth models to be reconstructed for each peat profile.

Environmental Monitoring↗

Reassessment of TL age estimates of burnt flints from the Paleolithic site of Tabun Cave, Israel.

The stratigraphy of Tabun Cave (Mt. Carmel), which comprises one of the longest sequences of Lower and Middle Paleolithic of the Near East, is widely used as a reference in debates on the evolution of Paleolithic industries and on the origin of modern humans and their relationship to the Neandertals. Considering the methodological improvements during the last ten years, the thermoluminescence (TL) dates of heated flints frequently quoted in the literature require an update. New TL results are discussed and compared with radiometric data recently obtained for this site, in particular by the ESR method, and with those obtained for other Levantine sites. The chronological framework previously proposed for the Paleolithic industries of the area is then re-examined.

Animals↗

[Mycobacteria--methods to meet the CDC guidelines].

In response to the guidelines from the Centers for Disease Control and Prevention, Atlanta, U.S.A. (1994), a considerable effort has been focused on the development and application of rapid laboratory testings for Mycobacterium tuberculosis. Concerning the first goal, "acid-fast bacillus smear results should be reported within 24 hr of specimen collection", most laboratories latently have an ability to perform unless the specimens will be processed in a lump. However, the second goal, "isolation and identification of M. tuberculosis should be within 10 to 14 days", is almost impossible for most Japanese laboratories where the radiometric Bactec 460 system is not applicable. In recent years, several nonradiometric, automated or semiautomated mycobacterial culture systems are developed and applied. To date, the evaluated results indicate that the newly developed mycobacterial culture systems with Middlebrook 7H9 broth can report positive with means of 17 to 20 day incubation, 3 to 6 days behind the CDC guidelines. Finally, regarding the third goal, "susceptibility test results should be within a total of 15 to 30 days", our developed microdilution test method can report quantitative minimum inhibitory concentrations (MICs) for M. tuberculosis after 7 day incubation. Overall, our procedures are very close to the CDC guidelines, except for isolation and identification of M. tuberculosis. The remaining key to fulfil the guidelines is a rapid detection, that is, culture media which can support rapid mycobacterial growth and advanced technology to detect attenuated growth of M. tuberculosis.

Bacteriological Techniques↗

Proterozoic eucaryotes from eastern california.

Both procaryotic and eucaryotic nannofossils occur in chert from the upper Beck Spring Dolomite (Pahrump Group) in northeastern San Bernardino County, California. These fossils include the oldest reasonably certain records to date of chlorophycean and chrysophycean algae, and hence of the eucaryotic or mitosing cell. Associated with these are cyanophycean procaryotes of still more ancient affinities. Indirect radiometric evidence implies an age of 1.2 to 1.4 aeons (1.2 to 1.4 x 10(9) years) for the enclosing rocks. Associated stromatolites are consistent with such an age assignment.

Journal Article↗

Direct estimation of the frequency of human cytotoxic T lymphocytes and their precursors following in vitro allosensitization.

Cell mediated lympholysis (CML) has been proposed as an in vitro model of the rejection process that results from transplantation of allogeneic tissue. To date, the absolute frequencies of cytotoxic T lymphocytes (CTL) and their precursors (CTL.P) have not been directly estimated in man because of technical difficulties. Through optimizing the conditions for radiometric detection of 51Cr release and the attendant improvement in CML sensitivity, direct CTL frequency estimates have been determined in peripheral blood (PBL), spleen (SPL), and lymph nodes (LNC) after in vitro allostimulation using unrelated human cells and limiting dilution assays. The mean frequency of CTL generated from PBL is 1 in 826 cells (0.121% +/- 0.101%) which, from preliminary experiments, is significantly greater than that generated from either LNC or SPL (p less than 0.05). With restimulation of primed cells on day 10, the frequency of CTL generated from PBL was increased 400%. The CTL.P frequency (0.0064% +/- 0.0050%) was approximately 5% of the corresponding CTL frequency. The CTL.P frequencies were found to be minimal estimates as both accessory "filler" cells and T cell growth factors increased the level of detection of CTL.P an average of threefold. The limiting cell dilution assay as detailed in this report should be a powerful tool for defining the cellular requirements and related factors necessary for optimal induction of a CTL response and should provide the means for determination of the immunogenetic requirements and the allospecificity of human cytotoxic lymphocytes.

Cells, Cultured↗

Ultraviolet radiation protection factors for clothing.

There has been considerable interest and activity in Australia during recent years in providing ultraviolet radiation protection for the public and the work force. Many requests from the public and manufacturers have been received by the Australian Radiation Laboratory for the quantification of the protection provided by different articles of clothing. The laboratory has been making spectral measurements of the ultraviolet radiation transmission of materials and fabrics for a number of years and, to this date, have tested and rated > 2,000 samples. The laboratory test methods for making spectral transmission measurements of both dry and wet fabric samples are described along with the radiometric test methods to determine ultraviolet radiation transmission. A scheme to designate the amount of ultraviolet radiation protection of materials using ultraviolet protection factors is outlined and used to compare the results obtained by different test methods. Some typical measurement results are also summarized and presented.

Clothing↗

[Report of a new radioimmunologic technic for the assay of HBs antigen].

We tested a new radiometric assay (Hépatube Wellcome) using a complete automatic device, in hepatitis B surface antigen detection with I 125 marked antibody. The additional advantage of this reagent is its very long life-span (twelve weeks after the date of manufacture). The hepatube system is fully automatic, micro processor-controlled and designed to complete all washing and tracer addition steps in the hepatube test sequence after addition of the patient's sample. The results were compared in the same protocol with those obtained by the method currently used in our group (Ausria II 125). This study has been carried out on 7.589 sera or plasma samples; blood donors 5.352; medical and chirurgical patients 1.292; sera panel 87; repeated tests 367; positives and negatives control sera 421; assays ran the first day 70 The 153 positive results (2.3%) were confirmed by another assay before neutralisation. The sensitivity of both techniques was compared using a reference panel containing samples showing varying degrees of positivity, and representative of both main subtypes. We repeated the assay on this panel 2 months after issue of materials and again 3 months later. This new system is more sensitive than Ausria II 125. Of 6 644 patients the false positive was found in 1,1% of the cases, this was superior to the results found with Ausria II 125 but there is no false negative with this new method. There was no difference when serum or plasma was used.

False Positive Reactions↗

A 3.3-Ma impact in argentina and possible consequences

Enigmatic glassy materials (escorias) and red bricklike materials (tierras cocidas) occur at a restricted stratigraphic level (the top of the Chapadmalal Formation). Materials from one locality near Mar del Plata are attributed to a mid-Pliocene impact event with a radiometric and magnetostratigraphic age of 3.3 million years ago (Ma). An extinction of endemic fauna (including the glyptodonts and flightless cariamid birds) correlates with the unit containing the impact glasses. Moreover, the age of the glasses is coincident within dating uncertainties with a pulselike change in the oxygen isotope marine record in the Atlantic and Pacific Oceans just before the late Pliocene deterioration of the climate.

Journal Article↗

Initial in-orbit results from a low-cost atmospheric ozone monitor operating on board the FASat-Bravo microsatellite.

In 1994, a collaborative programme was set up between the University of Surrey and the Chilean Air Force to design and build a low-cost 50 kg microsatellite with instrumentation capable of monitoring the distribution and concentration of stratospheric ozone, particularly over Chilean territory. This resulted in the joint design and development of the ozone-layer monitoring experiment (OLME), which was flown on board the resultant FASat-Bravo microsatellite, launched in July 1998 into an 820 km altitude Sun-synchronous orbit. The nadir-pointing OLME measures the solar ultraviolet light backscattered from the atmosphere in four spectral bands. From these raw radiometric data, total column ozone concentrations can be deduced. Since the launch, a series of high-spatial-resolution measurements have been made over Chilean scientific stations, while continuous low-spatial-resolution measurements have been used to provide global coverage. To date, the University of Surrey has concentrated on these global measurements, and has used a simplified ozone retrieval algorithm to check the results qualitatively against ozone maps produced by NASA's Earth Probe Total Ozone Mapping Spectrometer (TOMS) payload. These initial results look promising, with apparently good correlation between the two datasets. A novel, more-complex retrieval algorithm has been applied to the high-resolution data, and early results have shown agreement with the TOMS.

Algorithms↗

Surface aerosol radiative forcing derived from collocated ground-based radiometric observations during PRIDE, SAFARI, and ACE-Asia.

An approach is presented to estimate the surface aerosol radiative forcing by use of collocated cloud-screened narrowband spectral and thermal-offset-corrected radiometric observations during the Puerto Rico Dust Experiment 2000, South African Fire Atmosphere Research Initiative (SAFARI) 2000, and Aerosol Characterization Experiment-Asia 2001. We show that aerosol optical depths from the Multiple-Filter Rotating Shadowband Radiometer data match closely with those from the Cimel sunphotometer data for two SAFARI-2000 dates. The observed aerosol radiative forcings were interpreted on the basis of results from the Fu-Liou radiative transfer model, and, in some cases, cross checked with satellite-derived forcing parameters. Values of the aerosol radiative forcing and forcing efficiency, which quantifies the sensitivity of the surface fluxes to the aerosol optical depth, were generated on the basis of a differential technique for all three campaigns, and their scientific significance is discussed.

Journal Article↗

Oral administration of pyridostigmine bromide and huperzine A protects human whole blood cholinesterases from ex vivo exposure to soman.

Cholinesterases (ChEs) are classified as acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) according to their substrate specificity and sensitivity to selected inhibitors. The activities of AChE in red blood cells (RBC-AChE) and BChE in serum can be used as potential biomarkers of suppressed and/or heightened activity in the central and peripheral nervous systems. Exposure to organophosphate (OP) chemical warfare agents (CWAs), pesticides, anesthetics, and a variety of drugs such as cocaine, as well as some neurodegenerative and liver disease states, selectively reduces AChE or BChE activity. In humans, the toxicity of pesticides is well documented. Therefore, blood cholinesterase activity can be exploited as a tool for confirming exposure to these agents and possible treatments. Current assays for measurement of RBC-AChE and serum BChE require several labor-intensive processing steps, suffer from wide statistical variation, and there is no inter-laboratory conversion between methods. These methods, which determine only the serum BChE or RBC-AChE but not both, include the Ellman, radiometric, and deltapH (modified Michel) methods. In contrast, the Walter Reed Army Institute of Research Whole Blood (WRAIR WB, US Patent #6,746,850) cholinesterase assay rapidly determines the activity of both AChE and BChE in unprocessed (uncentrifuged) whole blood, uses a minimally invasive blood sampling technique (e.g., blood from a finger prick), and is semi-automated for high-throughput using the Biomek 2000 robotic system. To date, the WRAIR whole blood assay was used to measure AChE and BChE activities in human blood from volunteers in FDA clinical trials. In the first FDA study, 24 human subjects were given either 30 mg PB orally (n = 19) or placebo (n = 5). Blood samples were obtained pre-dosing and 2.5, 5, 8, and 24 h post-dosing. The samples were analyzed for AChE and BChE activity using the WRAIR WB robotic system, and for PB concentration by HPLC. We found that maximal inhibition of AChE (26.2%) and concentration of PB (17.1 ng/mL) occurred at 2.5 h post-PB dosing. AChE activity returned to almost 100% of pre-dose values by 6 h. A dose-dependent linear correlation was found between the amount of PB measured in the blood and the inhibition of AChE. Following soman (GD) exposure, recovered AChE activity was similar to levels that were reversibly protected by the PB administration. Therefore, the WRAIR ChE WB data clearly supports the conclusion that PB is an effective pre-treatment drug for nerve agent exposure (GD). In the second FDA human study for the treatment of Alzheimer's disease, the WRAIR ChE WB assay was used to determine the RBC-AChE and serum BChE profile of healthy elderly volunteers receiving Huperzine A. Huperzine A is a plant-derived reversible and selective AChE inhibitor compared to BChE, and is a more potent inhibitor of AChE than PB. Huperzine A is available as a nutraceutical, a natural supplement reported to improve memory, and has a variety of neuroprotective effects. Individuals received an increasing dose regimen of huperzine A (final dose 200 microg after 4 weeks), which produced more than 50% inhibition of RBC-AChE. Huperzine A was well tolerated by these patients at doses that sequestered more RBC-AChE than PB, and thus warrants further study as a prophylaxis for OP poisoning in addition to Alzheimer's therapy. Due to the documented use of OPs by terrorists and in warfare around the globe, Federal, State, and local authorities need a reliable, fast, inexpensive, and standard method for confirming such an assault in order to initiate appropriate containment, decontamination, and treatment measures. This assay is ideal for prescreening military personnel for atypical ChE activities that would preclude their deployment to areas of potential CWA exposure. The WRAIR WB ChE assay will fulfill the requirement for rapid and reliable monitoring of such exposure in military and civilian populations.

Administration, Oral↗

New early Jurassic tetrapod assemblages constrain Triassic-Jurassic tetrapod extinction event.

The discovery of the first definitively correlated earliest Jurassic (200 million years before present) tetrapod assemblage (Fundy basin, Newark Supergroup, Nova Scotia) allows reevaluation of the duration of the Triassic-Jurassic tetrapod extinction event. Present are tritheledont and mammal-like reptiles, prosauropod, theropod, and ornithischian dinosaurs, protosuchian and sphenosuchian crocodylomorphs, sphenodontids, and hybodont, semionotid, and palaeonisciform fishes. All of the families are known from Late Triassic and Jurassic strata from elsewhere; however, pollen and spore, radiometric, and geochemical correlation indicate an early Hettangian age for these assemblages. Because all "typical Triassic" forms are absent from these assemblages, most Triassic-Jurassic tetrapod extinctions occurred before this time and without the introduction of new families. As was previously suggested by studies of marine invertebrates, this pattern is consistent with a global extinction event at the Triassic-Jurassic boundary. The Manicouagan impact structure of Quebec provides dates broadly compatible with the Triassic-Jurassic boundary and, following the impact theory of mass extinctions, may be implicated in the cause.

Animals↗

Rapid radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis.

Pyrazinamide (PZA) is one of the most important drugs in modern chemotherapy of tuberculosis. Since PZA is active only at an acid pH, testing the susceptibility of Mycobacterium tuberculosis to PZA is difficult and timeconsuming. Therefore, we evaluated the BACTEC system for rapid testing of PZA susceptibility at pH 6. A total of 91 M. tuberculosis strains and 2 different strains of M. bovis BCG were screened for susceptibility to PZA. Each strain was tested in special 7H12 broth supplemented with polyoxyethylene stearate containing 25, 50 and 100 micrograms PZA/ml. Strains resistant to 100 micrograms/ml were retested against 25-100 micrograms/ml and at an extended range of PZA concentrations from 200-6,400 micrograms/ml. The MIC was determined with all strains within 4-20 (mean 7) days. Of the 77 susceptible strains, based on the pyrazinamidase test, MIC were less than or equal to 25 micrograms/ml for 34 strains, 50 for 38 and 100 for 2 strains. Three pyrazinamidase-positive strains had still higher MIC, 1 at 800 and 2 at 3,200 micrograms/ml. PZA-resistant strains had MIC of 800 or greater. Monoresistance to PZA has not been detected to date. The clear bimodal distribution of MIC in this method could enable the routine clinical microbiology laboratory to perform PZA susceptibility testing as easily as the 4 drugs now tested in the BACTEC system.

Evaluation Studies as Topic↗

In vitro characterization of synthesized thyroglobulin immune complexes (IC). A model for studies of IC containing an autoantigen.

Human thyroglobulin (Tg) immune complexes (TgIC) were preformed at different ratios from purified Tg, and Tg antibodies (TgAb) obtained from six patients with autoimmune thyroid diseases. TgIC were characterized by precipitation with polyethylene glycol, and sedimentation in sucrose gradient. TgIC from one patient were further characterized by concanavalin A (con A), and binding to the complement factor Clq and rheumatoid factor (RF). Tg and TgIC had almost identical binding to con A, no binding to Clq, but could be partially separated by ultracentrifugation and polyethylene glycol. The highest degree of separation was obtained by a RF-coated plastic tube radiometric assay, using 125-I-rabbit TgAb as indicator. Tg showed no binding to RF, and a dose-response curve of TgIC in serum could be established. There was a dependence of the Tg-TgAb ratio, TgIC at equilibrium and in antibody excess being detected most efficiently. The method may serve as an aid in the evaluation of the fate of Tg, TgAb and TgIC following thyroid damage (surgery, radioiodine) and may be extended as a model system in the investigation of immune complexes in connection with autoimmune disorders.

Antigen-Antibody Complex↗

Initial evaluation of human monoclonal anti-lipid A antibody (HA-1A) in patients with sepsis syndrome.

HA-1A, a human monoclonal immunoglobulin M antibody that binds specifically to the lipid A domain of endotoxin, was administered to septic patients to evaluate the safety, pharmacokinetics, and immunogenicity of the antibody. Thirty-four patients received a single infusion of either 25 mg, 100 mg, or 250 mg, and were followed clinically for 14 to 21 days after treatment. HA-1A serum levels were measured before infusion and frequently after infusion with a radiometric assay. A one-compartment pharmacokinetic model was fit to the measured serum levels, and accurately described the changes in HA-1A level over time in each dose group (r2 = .99). The mean +/- SEM apparent volume of distribution of HA-1A was 48.5 +/- 4.5 ml/kg, and the mean serum clearance was 2.8 +/- 0.4 ml/kg.h. The mean serum half-life of HA-1A was 15.9 +/- 1.5 h. The mean serum level one hour after a 100-mg dose was 33.2 +/- 2.4 micrograms/ml, and the mean concentration 24 h later was 9.1 +/- 1.6 micrograms/ml. The dose administered and presence of Gram-negative bacterial infection did not significantly influence the volume of distribution or serum clearance. No adverse reactions to HA-1A were observed, and no antibodies against HA-1A were detected in any patient. These data indicate that the pharmacokinetics of HA-1A are well described by a one-compartment pharmacokinetic model, and that HA-1A is safe and nonimmunogenic in patients with sepsis.

Adult↗