Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PERIMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

The effect of attention on conventional automated perimetry and luminance size threshold perimetry.

PURPOSE: To investigate the effects of divided attention on conventional automated perimetry (CAP) and luminance size threshold perimetry (LSTP). METHODS: Ten healthy subjects, ages 27 to 65, with two perimetry types (CAP and LSTP) were tested in random order. At a later session, these tests were given with a mental workload to simulate the effect of anxiety or distraction on subjects performing visual field testing, also in random order. The mental workload, the Paced Auditory Serial Addition Test (PASAT), was first administered to each subject, and the score was recorded. During the visual field testing, the PASAT was again administered continuously. Each subject was instructed to attend primarily to the PASAT while taking each visual field test. RESULTS: CAP was affected by the addition of the PASAT, with a worsening of sensitivity from an average of 30.0 +/- 0.67 to 24.2 +/- 7.4 dB with a range of -0.04 to -23.2 dB (P = 0.04). LSTP showed a generalized reduction in threshold 1.71 +/- 0.22 to 2.35 +/- 0.72 dB with a range of 0.12 to -2.17 dB (P = 0.25). The percentage of correct responses on the PASAT was not significantly different between CAP (76.9%) and LSTP (74.8%). False-positive and -negative catch trial responses were increased during CAP with PASAT testing (P = 0.009). A substantial increase of fixation losses occurred during CAP with PASAT (3.7-16.2, P = 0.002). LSTP with PASAT showed increases in localization error (P < 0.001) and reaction time (P = 0.004). CONCLUSIONS: Divided attention significantly affects performance on conventional automated perimetry with its fixed size stimuli and when the stimuli are scaled (LSTP). The deficits may simulate nerve-fiber-bundle-like defects.

Adult↗

[A dissociation of thresholds between Goldmann kinetic perimetry and high-pass resolution perimetry in retinitis pigmentosa].

The authors studied the differences between the automated static perimetry of high-pass resolution perimeter (HRP) and the kinetic perimetry of the Goldmann perimeter in 12 patients with retinitis pigmentosa. In a total of 10 eyes of 6 patients, we found 19 quadrants in which the patients were not able to recognize the largest ring target even when the target was within the isopter of the Goldmann perimetry. Also, there were 10 quadrants in which the largest target was not recognized in a total of 6 eyes of 4 patients even though their visual field showed symmetrical isopter in upper and lower or right and left quadrants in the Goldmann perimetry. As a result, it was suggested that the causes of the dissocation were a greater decrease in sensitivity for the low spatial frequency target than the high spatial frequency target and/or a greater decrease in resolution sensitivity than light sensitivity in retinitis pigmentosa.

Adolescent↗

Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry.

OBJECTIVE: To investigate whether frequency-doubling perimetry (FDP) predicts future visual field loss with achromatic automated perimetry (AAP), just as it may be predicted with short-wavelength automated perimetry (SWAP). METHODS: We recruited 62 patients selectively from an urban glaucoma practice. At the commencement of the study, each patient had ocular hypertension with normal visual fields on AAP. Baseline SWAP and FDP were performed to determine whether underlying earlier visual field loss was present. Patients were then followed up prospectively for 3 years with annual AAP, SWAP, and FDP. Main Outcome Measure The development of visual field loss on AAP. RESULTS: Nine subjects had abnormal SWAP findings and 10 had abnormal FDP findings. At the conclusion of the study, field loss on AAP developed in 5, all of whom had preexisting abnormal SWAP and FDP results. No AAP visual field loss developed in patients with a normal SWAP or FDP. The rate of development of visual field loss on AAP was therefore significantly greater for those with abnormal SWAP (chi21 = 40.83; P<.001) and abnormal FDP findings (chi21 = 32.76; P<.001) than for those with normal SWAP and FDP findings. CONCLUSION: In the same way that SWAP may predict AAP visual field loss, FDP may also detect field loss earlier than AAP.

Female↗

HPR perimetry and Humphrey perimetry in glaucomatous children.

Fifteen children aged less than 11 years, affected by congenital glaucoma, underwent visual field testing using two different methods: conventional computerized perimetry (24-2 Humphrey program) and High Pass Resolution perimetry (Ring test). The aim of the study was to discover which of the two perimetric techniques was more suitable for younger patient. Results showed that HPR perimetry is more suitable to children. Reasons include the short duration of the test (5 min), and the appearance like a pleasant game to 80% of the subjects tested. In addition it proved to be better than Humphrey test because of the minimal possibilities of memorisation with a reproducibility factor of 68% in our sample and because of the reliable results and satisfactory evaluation in 76% of the eyes examined.

Child↗

[Conventional perimetry. Part 3: Static perimetry: grid--strategy--visualisation].

Methods for visual field examination using static strategies began with manual static profile perimetry. The transition from a linear stimulus alignment along the profile section to a two-dimensional grid arrangement introduced the era of static grid perimetry. The use of computers makes it possible to automate and standardise this process, allowing the examiner to choose the visual field area, an adequate grid and the optimal strategy, while leaving the processing, visualisation and recording completely observer-independent. This contribution is based only on conventional static procedures for visual field examination (the use of white on white perimetry) as this technique is easily accessible, standardised and well established in everyday practice.

Diagnosis, Computer-Assisted↗

[Conventional techniques of visual field examination: part 4 Static perimetry: interpretation--perimetric indices--follow-up--perimetry in childhood].

Visual field examination with fixed stimuli was first realized in manual static profile perimetry. The transition from a linear stimulus alignment along a profile section towards a two-dimensional arrangement introduced the era of static grid perimetry. Application of computer technology nowadays allows automation and standardization of this procedure, which enables the examiner to select the necessary visual field area, the adequate grid, and the optimal strategy for an estimation of differential luminance sensitivity. Furthermore, the computer independently takes over the recording, visualization, and processing of the perimetric procedure. This contribution discusses conventional static visual field examinations since these are widely used, easily accessible, well established for practical application, and standardized. This paper (part 4) explicitly focuses on the correct interpretation of automated static strategies of visual field examinations. Furthermore the classification and scoring of visual field defects as well as quality control, progression analysis, and perimetry in childhood are addressed. This manuscript is based on three preceding parts, which were published in previous issues of this journal [27, 28, 29].

Child↗

Fundus perimetry with the Micro Perimeter 1 in normal individuals: comparison with conventional threshold perimetry.

PURPOSE: To determine differential light threshold values obtained with the Micro Perimeter 1 (MP1) in healthy volunteers and to correlate them with conventional automated static threshold perimetry using the Octopus 101 Perimeter. DESIGN: Prospective comparative observational study. PARTICIPANTS: Thirty healthy volunteers. METHODS: In 30 eyes of 30 healthy volunteers, static threshold perimetry was performed with the MP1 Micro Perimeter (Nidek Inc., Italy) and the Octopus 101 (Haag-Streit AG, Switzerland) in the same eye in random order. MAIN OUTCOME MEASURES: Differential light threshold values obtained with the MP1 and their difference to differential light threshold values with the Octopus. Differential light sensitivity was compared for 21 matching points in a rectangular test grid using similar examination settings with Goldmann III stimuli, stimulus presentation time of 100 msec, and white background illumination (1.27 cd/m2). RESULTS: For the 21 matching locations, mean differential light thresholds with the MP 1 and the Octopus were 15.5+/-0.8 decibels (dB) (range, 13.0-17.1) and 30.2+/-1.2 dB (range, 27.7-32.0), respectively. On the average, the Octopus showed higher threshold values for all test locations than the MP1. The mean difference between both examinations was 14.6+/-1.8 dB for all locations and 14.8+/-1.7 dB excluding the test locations at the blind spot. With a considerably high grade of variation according to the test point location, the difference between the 2 devices varied from 11.4 to 18.3 dB, showing a vertical asymmetry with a larger difference in the lower part of the visual field. Linear regression of the perimetric results for each test point location, excluding the area of the blind spot and the lower line of the test grid, showed significant correlation (r = 0.56; P = 0.036). CONCLUSIONS: The results show that the MP1 provides reproducible threshold values with a systematic difference compared with standard Octopus perimetry of approximately 15 dB. With a larger difference in the lower part of the visual field, differential light sensitivity values in microperimetry with the MP1 are comparable to the threshold values obtained with the Octopus 101 using a correction factor of 11.4 to 18.3 dB according to stimulus location.

Adult↗

Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage.

OBJECTIVE: Reevaluation of the relationship between short wavelength automated perimetry (SWAP), standard achromatic perimetry (SAP), and frequency doubling technology (FDT) in glaucoma and ocular hypertensive patients and in glaucoma suspects. DESIGN: Prospective comparative observational study. PARTICIPANTS: Four age-matched groups were evaluated (42 patients with early to moderate glaucoma, 34 ocular hypertensives, 22 glaucoma suspects, and 25 normal controls) using SAP, SWAP, and FDT. INTERVENTION: All participants underwent full clinical ophthalmologic evaluation followed by SWAP, SAP, and FDT perimetry within a period of not more than 3 months. Mean defect (MD), pattern standard deviation (PSD), visual field (VF) indices, and the percentage of depressed visual field points with P value <5% and <1% in the pattern deviation plot were evaluated. MAIN OUTCOME MEASURES: For each of the four study groups, the MD, PSD, and the percentage of abnormal points significantly depressed <5% and <1% were compared for the three VF testing modalities. RESULTS: In the glaucoma group, the mean percentage of the total number of abnormal points in SWAP was significantly less than abnormal points in SAP and FDT, both for 5% (P values were 0.0001 and 0.0001, respectively) and 1% (P values were 0.0001 and 0.0001, respectively). The same applied to the ocular hypertensives group. However, in the suspects group, no significant difference was detected. In normal controls, the abnormal points in SWAP were significantly lower than those in SAP for 5% (P value was 0.01) and 1% (P value was 0.05). FDT detected significantly larger defects (percentage of points <5%) than SAP in ocular hypertensives and suspects (P values were 0.01 and 0.004, respectively). CONCLUSIONS: SWAP in its existing condition is markedly less efficient than either SAP or FDT in detecting VF defects, especially in glaucoma patients and ocular hypertensives (defects detected with SWAP are less than both SAP and FDT). Defects detected with FDT are equivalent to SAP and sometimes larger, especially in ocular hypertensives and glaucoma suspects; this makes it a useful tool for picking up early glaucomatous defects in populations at risk.

Adult↗

A comparison of short wavelength automated perimetry with frequency doubling perimetry for the early detection of visual field loss in ocular hypertension.

BACKGROUND: Achromatic automated perimetry (AAP) is limited in its ability to detect very early visual field loss in ocular hypertensive patients. Tests targeting axons that are selectively damaged, or have low redundancy, may detect visual field losses before they are seen on AAP. It has been claimed that short wavelength automated perimetry (SWAP) and frequency doubling perimetry (FDP) are two tests that provide early detection. METHODS: Patients (n = 62) were selected on the basis that they had raised intraocular pressure but normal visual fields detected by AAP. A SWAP and an FDP was performed on each of the patients and the results compared. Fields were scored as either normal or abnormal based on criteria used in previous studies. RESULTS: On comparing FDP with SWAP as the 'gold standard', a sensitivity of 88.9% and a specificity of 96.2% was found, showing a high concordance between the two tests. CONCLUSION: These results suggest that as SWAP may be predictive of AAP visual field loss, FDP may be similarly predictive.

Adult↗

Relationship between indices of Humphrey perimetry and Frequency Doubling Technology Perimetry in glaucoma.

PURPOSE: To study whether the correlation between indices of Humphrey perimetry and Frequency Doubling Technology (FDT) perimetry differs in the early and later stages of glaucoma. METHODS: This study included 200 eyes of 200 patients with primary open-angle glaucoma or normal-tension glaucoma. The eyes were classified into the early and later stages by the median value (-4.51 dB) (Classification 1; n = 100 and 100, respectively) or the average value of the maximum and minimum values (-11.90 dB) (Classification 2; n = 165 and 35, respectively) of mean deviation (MD) obtained from a set of measurements with the Humphrey Full-Threshold 30-2 program in all eyes. The correlation between MD (H-MD) or pattern standard deviation (PSD) (H-PSD), as obtained from another set of measurements with the Humphrey Full-Threshold 30-2 program, and MD (F-MD) or PSD (F-PSD), as calculated by the Full-Threshold N-30 program of FDT perimetry, were evaluated using linear regression analysis. RESULTS: Overall, H-MD and H-PSD significantly correlated with F-MD (r = 0.713; P < 0.001) and F-PSD (r = 0.731; P < 0.001), respectively. In each of Classifications 1 and 2, H-MD and H-PSD significantly correlated with F-MD and F-PSD, respectively, both in the early and later stages. However, in each classification, the correlation between H-MD and F-MD differed significantly between the two stages (Classification 1; P < 0.001; Classification 2, P = 0.003), while the correlation between H-PSD and F-PSD did not differ significantly between the two stages. CONCLUSION: The degree of correlation between H-MD and F-MD differed between the early and later stages of glaucoma.

Female↗

A new scoring system for comparing the results of high-pass resolution perimetry and differential light sensitivity perimetry in glaucoma patients.

Using a new standard, we compared the visual field defects detected by high-pass resolution perimetry (HRP) and differential light sensitivity (DLS) perimetry in 61 eyes of 61 open-angle glaucoma patients. Abnormal test points were determined using probability plot analysis of HRP and total deviation probability maps of the Humphrey Field Analyzer. To evaluate the agreement between the two tests, we developed a new scoring system. Thirty-three eyes, 23 eyes, and 5 eyes had good, fair, and poor agreement, respectively. In relation to Aulhorn's stage classification, the more advanced the glaucomatous stage, the more increased the percentages of good agreement. These results suggest that the distribution and severity of visual field defects demonstrated by HRP agree closely with those found using DLS perimetry in glaucomatous eyes, especially those with advanced visual field changes.

Adolescent↗

Visual field assessment in glaucoma: comparative evaluation of manual kinetic Goldmann perimetry and automated static perimetry.

PURPOSE: To compare the detection and assessment of progression of visual field defects in primary open-angle glaucoma with manual suprathreshold perimetry on Goldmann perimeter and automated static threshold perimetry on Humphery visual field (HVF) analyzer. METHODS: 105 eyes of 54 patients of primary open-angle glaucoma were followed up with 3-monthly perimetry on Goldmann perimeter and HVF analyzer, for a period of 9 months. RESULTS: HVF analyzer picked up visual field defects in 48 (46%) eyes whereas Goldmann perimeter picked up visual field defects in 26 (25%) eyes. HVF analyzer demonstrated progression in 14 eyes whereas Goldmann perimeter detected progression in 7 eyes during follow up of 9 months. CONCLUSIONS: HVF analyzer is superior to Goldmann perimeter to document and to demonstrate progression of visual field defects in primary open-angle glaucoma.

Adolescent↗

Comparison of standard white-on-white automated perimetry and short-wavelength automated perimetry in early glaucoma patients.

BACKGROUND: To evaluate the relationship between short-wavelength automated perimetry (SWAP) and the standard white-on-white automated perimetry (W-W) in detection of early glaucomatous visual field deficits. METHODS: Twenty-four patients suspected of having glaucoma and who had experience with automated visual field tests were evaluated by SWAP and standard W-W perimetry. Results of the mean deviation (MD), pattern standard deviation (PSD), pattern deviation probability plot, test reliability, and test time were compared. RESULTS: The average MD in the SWAP group was significantly higher than that in the W-W group (SWAP: -6.55 db, W-W: -2.69 db, p<0.001). A significant difference also existed in PSD between the 2 groups (SWAP: 3.49 db, W-W: 2.40 db, p<0.001). The test time was longer in the SWAP group than in the W-W group (SWAP: 15 min, 6 s; W-W: 13 min, 8 s, p<0.001). There was no significant difference between the 2 groups in test reliability or in the number of points that were depressed below the 1% and 5% sensitivity levels on the pattern deviation probability plot. CONCLUSIONS: This study showed that greater MD and PSD were demonstrated with SWAP. The test time was longer for SWAP. However, in order to conclude that SWAP is an early indicator of glaucomatous damage, longer follow-up and further analyses are required.

Adolescent↗

[Comparison of SKP (semi-automated kinetic perimetry) and SASP (suprathreshold automated static perimetry) techniques in patients with advanced glaucoma].

PURPOSE: To compare the results of conventional suprathresold automated static perimetry (SASP) and a new method of kinetic visual field examination (semi-automated kinetic perimetry--SKP) in patients with advanced retinal nerve fibre layer (RNFL) defects, caused by glaucoma. MATERIAL AND METHODS: Nineteen patients (10 women and 9 men) suffering from advanced open-angle glaucoma (17 patients) and low tension glaucoma (2 patients) were enrolled in this study. The mean age was 65.3 years (range 49.0-82.9 years). One eye of each subject was examined with SKP and SASP, both implemented in Octopus 101 perimeter (Haag-Streit, Koeniz, Switzerland) on the same day. The examiner using SKP did not know the SASP results. The static visual field examination was performed first. In order to compare visual fields results obtained with both methods, only central 30 degree area of the visual fields was taken into consideration. The area obtained by creating a virtual isopter (option of SKP software) located between the position of defective and intact visual field regions of SASP and the area of I4e isopter obtained with SKP (stimulus angular velocity 3 degrees/s) were measured in deg2 and compared. RESULTS: The mean area (+/-SD) of I4e isopter obtained with SKP was 1882 deg2 (+/- 510 deg2) and the mean area of SASP 30 degree visual field was 1737 deg2 (+/- 546 deg2). This difference was not statistically significant. CONCLUSION: Quantitative comparison of static and kinetic perimetry is a difficult task to perform. The SKP software offers a possibility of direct quantitative assessment of the area of each isopters in deg2. This study shows that the results of visual field examinations obtained with both methods in this group do not differ significantly between SASP and SKP.

Aged↗

High-pass resolution perimetry and light-sense perimetry in open-angle glaucoma.

To determine the correlation between the results obtained with light-sense and ring perimetry in glaucoma, we examined 201 eyes of 107 patients with ocular hypertension or different stages of glaucoma using Octopus 1-2-3 and the Ophthimus ring perimeter. Statistical parameters describing the mean visual field defect ["global defect, GD," or "neural capacity, NC" (Ophthimus)] were significantly correlated (P < 0.0001). Statistical parameters describing the local deviations were significantly correlated as well ["loss of variance, LV" (Octopus) and "local defect, LD" (Ophthimus), P < 0.0001]. Correlation between the MD and the LV or LD was somewhat less significant. As compared with the MD or LV (Octopus) the Ophthimus parameters GD, NC, and LD were less often pathological. We conclude from our data that due to the good correlation between light-sense and resolution perimetry results, both perimeters are equally suited for the follow-up of glaucoma patients. Sensitivity to early glaucomatous damage seems to be higher in light-sense perimetry (Octopus 1-2-3).

Adult↗

A comparison of Peritest automated perimetry and Goldmann perimetry.

Both Peritest perimetry and Goldmann visual field testing were performed on three groups of eyes. Eighty-one eyes had glaucoma with elevated intraocular pressures and abnormal visual fields determined by Goldmann perimetry. There were 47 eyes with suspected glaucoma, based on elevated IOPs and normal Goldmann visual fields. Nineteen eyes were normal. All visual fields were evaluated in masked fashion, and the results were compared. The Peritest had a high sensitivity in both glaucomatous (98.8%) and normal (94.7%) eyes. One half of the eyes with suspected glaucoma had abnormal Peritest results but normal Goldmann visual fields. These eyes were examined prospectively with color stereo discs and monochromatic nerve fiber layer photographs. One half of the eyes with suspected glaucoma and abnormal Peritest results also had photographic evidence suggesting optic nerve damage. Thus, early field defects detected by the Peritest perimeter in eyes with suspected glaucoma are likely to be representative of glaucomatous damage.

Adult↗

Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma.

PURPOSE: To evaluate the reproducibility and efficacy of frequency-doubling perimetry (FDP), a new perimetric method for the detection of functional glaucomatous damage. METHODS: Thirty-four glaucomatous eyes of 34 patients were examined by FDP (using the complete N30 threshold test of the Humphrey Frequency Perimeter) and by standard achromatic computerized perimetry (SAC; using the full threshold program 30-2 of the Humphrey Field Analyzer). Twenty-six of these eyes were examined twice by FDP. Reproducibility of repeated FDP was tested by the difference and the average of mean deviations (MD). Efficacy was studied by comparison of FDP and SAC using MD, as well as threshold results of FDP and corresponding SAC-tested areas. Spearman's rank correlation was calculated. RESULTS: A significant correlation of repeated FDP examinations was found regarding MD [r=0.94, P<0.00001 (n=26)]. The reproducibility of FDP was independent of the glaucomatous damage [r=0.04, P=0.85 (n=26)], based on the correlation of the difference, and the average of MD. The MD of FDP and that of SAC showed a significant correlation [r=0.87, P<0.00001 (n=34)]. In advanced glaucoma, FDP tended to yield lower measurement values than SAC. Regarding corresponding areas, there was a significant correlation between threshold results of FDP-tested areas and the corresponding SAC testpoints [r=0.92, P<0.00001 (n=34)]. The conformity decreased from the peripheral to the central tested visual field. CONCLUSIONS: Sufficient reproducibility of FDP could be demonstrated in early and advanced glaucomatous visual field defects. Conformity between FDP and SAC was shown in terms of MD and threshold results of FDP-tested areas and corresponding SAC testpoints.

Aged↗

Frequency-doubling perimetry: comparison with standard automated perimetry to detect glaucoma.

PURPOSE: To compare second generation frequency-doubling perimetry (FDP) with standard automated perimetry (SAP) to detect glaucomatous visual field abnormalities. DESIGN: Prospective, cross-sectional, controlled observational study. METHODS: Fifty eyes of 50 patients with glaucoma with confirmed SAP visual field abnormalities and 42 eyes from 42 normal control subjects were studied. Swedish Interactive Thresholding Algorithm (SITA) standard 24-2 SAP and FDP visual fields were performed. The correlation of global indices and the number of defects on total deviation (TD) and pattern deviation (PD) plots were compared. The spatial concordance of FDP and SAP defect locations was determined. RESULTS: In patients with glaucoma, significant correlations of mean deviation (MD) and pattern standard deviation (PSD) were found between SAP and FDP (P < .001 for MD and P < .001 for PSD), but not in the normal group. FDP had significantly greater defect scores than SAP on total deviation and PD plots in the glaucoma group (P = .028 and P = .01, respectively). In comparison with SAP, sensitivity and specificity of FDP were 92% and 98% with glaucoma hemifield test criteria and 98% and 93% with PSD <5% criteria, respectively. Similarly high diagnostic precision was found with MD and PSD (at 95% specificity; MD and PSD sensitivity was 82% and 90%, respectively). The location of defects within 12 hemifield clusters found with FDP agreed moderately well with those detected with SAP (kappa = .48). CONCLUSIONS: FDP and SAP perform similarly in their ability to detect visual field defects in early to moderate glaucoma. Larger and deeper defects detected with FDP suggests the possibility of earlier detection at high specificity.

Adult↗