Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “NEUTRONS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Dosimetric effects of beam size and collimation of epithermal neutrons for boron neutron capture therapy.

A series of studies of "ideal" beams has been carried out using Monte Carlo simulation with the goal of providing guidance for the design of epithermal beams for boron neutron capture therapy (BNCT). An "ideal" beam is defined as a monoenergetic, photon-free source of neutrons with user-specified size, shape and angular dependence of neutron current. The dosimetric behavior of monoenergetic neutron beams in an elliptical phantom composed of brain-equivalent material has been assessed as a function of beam diameter and neutron emission angle (beam angle), and the results are reported here. The simulation study indicates that substantial differences exist in the dosimetric behavior of small and large neutron beams (with respect to the phantom) as a function of the extent of beam collimation. With a small beam, dose uniformity increases as the beam becomes more isotropic (less collimated); the opposite is seen with large beams. The penetration of thermal neutrons is enhanced as the neutron emission angle is increased with a small beam; again the opposite trend is seen with large beams. When beam size is small, the dose delivered per neutron is very dependent on the extent of beam collimation; this does not appear to be the case with a larger beam. These trends in dose behavior are presented graphically and discussed in terms of their effect on several figures of merit, the advantage depth, the advantage ratio, and the advantage depth-dose rate. Tables giving quick summaries of these results are provided.

Boron Neutron Capture Therapy↗

Clinical dosimetry of an epithermal neutron beam for neutron capture therapy: dose distributions under reference conditions.

PURPOSE: The aim of this study was to asses the dose distribution under reference conditions for the various dose components of the Petten clinical epithermal neutron beam for boron neutron capture therapy (BNCT). METHODS AND MATERIALS: Activation foils and a silicon alpha-particle detector with a 6Li converter plate have been used for the determination of the thermal neutron fluence rate. The gamma-ray dose rate and the fast neutron dose rate have been determined using paired ionization chambers. Circular beam apertures of 8, 12 and 15 cm diameters have been investigated using a 15 x 15 x 15 cm3 solid polymethyl-methacrylate phantom, a water phantom of the same dimensions and a 30 x 30 x 30 cm3 water phantom at various phantom to beam-exit distances. RESULTS: The effect of phantom to beam-exit distance could be modeled using an inverse square law with a virtual source to beam-exit distance of 3.0 m. At a reference phantom to beam-exit distance of 30 cm, three-dimensional dose and fluence distributions of the various dose components have been determined in the phantoms. The absolute thermal neutron fluence rate at a reference depth of 2 cm in the 15 cm water phantom increased by 43% when the field size was increased from 8 to 15 cm. Simultaneously the gamma-ray dose rate increased by 46% while the fast neutron dose rate increased by only 5%. CONCLUSION: A reference treatment position at 30 cm from the beam exit allows convenient patient positioning with a relatively small increase in irradiation time compared to positions very close to the beam-exit. A more homogeneous distribution of thermal neutrons over a target volume, a higher absolute thermal neutron fluence rate and a lower contribution of the fast neutron dose to the total dose will result in improved treatment plans when using a 12 cm or 15 cm field compared to a 8 cm field. The dose distributions will be used as benchmark data for treatment planning systems for BNCT.

Boron Neutron Capture Therapy↗

Beam collimation and bolusing material optimizations for 10boron neutron capture enhancement of fast neutron (BNCEFN): definition of the optimum irradiation technique.

PURPOSE: In boron-10 neutron capture enhancement of fast neutron irradiation (BNCEFN), the dose enhancement is correlated to the 10B concentration and thermal neutron flux. A new irradiation technique is presented to optimize the thermal neutron flux. METHODS AND MATERIALS: The coupled FLUKA and MCNP-4A Monte Carlo codes were used to simulate the neutron production and transport for the Nice and Orleans facilities. RESULTS: The new irradiation technique consists of a 20-cm lead blocks additional collimator, placed close to the patient's head, which is embedded in a pure graphite cube. A 24-fold thermal neutron flux increase is calculated between a 5 x 5 cm2 primary collimated field, with the patient's head in the air, and the same field size irradiated with the optimum irradiation technique. This increase is more important for the p(60)+Be Nice beam than for the p(34)+Be Orleans one. The thermal neutron flux is 2.1 x 10(10) n(th)/Gy for each facility. Assuming a 100 microg/g 10B concentration, a physical dose enhancement of 22% is calculated. Moreover, the thermal neutron flux becomes independent of the field size and the phantom head size. CONCLUSION: This technique allows conformal irradiation of the tumor bed, while the thermal neutron flux is enhanced, and spreads far around the tumor.

Boron Neutron Capture Therapy↗

The vacuum geometry effect on neutron transmission and spatial resolution of neutron transmission.

Frequently, shields used against radiation contain some vacuum channels. We have therefore considered an infinite slab with a fixed thickness (thickness 20 lambda with lambda the mean free path of the neutron in the slab) and an infinite plane source of neutrons which arrived on the left side of the slab; transmitted neutrons through the slab to its right side are detected by finite detectors having windows equal to 2 lambda. This slab contains a vacuum channel. This channel has many legs with several horizontal parts. We used the Monte Carlo method for sampling the neutron history in the slab with a spatial biasing technique in order to accelerate the calculation convergence (Levitt, L. B. (1968) Nuclear Science and Engineering 31, 500-504; Jehouani, A., Ghassoun, J. and Aboubker, A. (1994) In Proceedings of 6th International Symposium on Radiation Physics, Rabat, Morocco). We studied the effects of the angle position and the number of horizontal parts of the channel on the neutron transmission. We have studied the effect of the vacuum channel opening (Artigas, R. and Hungerford, H. E. (1969) Nuclear Science and Engineering 36, 295-303) on the neutron transmission; for several values of this opening we have calculated the neutron transmission probability for each detector position. This study allowed us to determine the optimal conditions of vacuum geometries to improve protection against neutrons. In the second part we considered a shield which consists of a slab and a two-legged vacuum channel with two horizontal parts. The spatial distribution of neutrons transmitted through the protection screen was determined. This distribution shows two peaks. The study was made for different distances between the two horizontal parts. We have determined the smallest distance between the two horizontal parts for which the two peaks can be resolved.

Monte Carlo Method↗

Micromegas neutron beam monitor neutronics.

The Micromegas is a type of ionising radiation detector that consists of a gas chamber sandwiched between two parallel plate electrodes, with the gas chamber divided by a Frisch grid into drift and amplification gaps. Investigators have applied it to a number of different applications, such as charged particle, X-ray and neutron detection. A Micromegas device has been tested as a neutron beam monitor at CERN and is expected to be used for that purpose at the Spallation Neutron Source (SNS) under construction in Oak Ridge, TN. For the Micromegas to function effectively as neutron beam monitor, it should cause minimal disruption to the neutron beam in question. Specifically, it should scatter as few neutrons as possible and avoid neutron absorption when it does not contribute to generating useful information concerning the neutron beam. Here, we present the results of Monte Carlo calculations of the effect of different types of wall materials and detector gases on neutron beams and suggest methods for minimising disruption to the beam.

Computer Simulation↗

A Monte Carlo investigation of the dosimetric properties of monoenergetic neutron beams for neutron capture therapy.

A Monte Carlo simulation study has been carried out to investigate the suitability of neutron beams of various energies for therapeutic efficacy in boron neutron capture therapy. The dosimetric properties of unidirectional, monoenergetic neutron beams of varying diameters in two different phantoms (a right-circular cylinder and an ellipsoid) made of brain-equivalent material were examined. The source diameter was varied from 0.0 to 20.0 cm; neutron energies ranged from 0.025 eV up to 800 keV, the maximum neutron energy generated by a tandem cascade accelerator using 2.5-MeV protons in a 7Li(p,n)7Be reaction. Such a device is currently under investigation for use as a neutron source for boron neutron capture therapy. The simulation studies indicate that the maximum effective treatment depth (advantage depth) in the brain is 10.0 cm and is obtainable with a 10-keV neutron beam. A useful range of energies, defined as those neutron energies capable of effectively treating to a depth of 7 cm in brain tissue, is found to be 4.0 eV to 40.0 keV. Beam size is shown not to affect advantage depth as long as the entire phantom volume is used in determining this depth. Dose distribution in directions parallel to and perpendicular to the beam direction are shown to illustrate this phenomenon graphically as well as to illustrate the differences in advantage depth and advantage ratio and the contribution of individual dose components to tumor dose caused by the geometric differences in phantom shape.

Boron↗

[Pathomorphosis of laryngeal cancer after neutron and gamma-neutron therapy using fast neutrons of the reactor].

Studies of tumours and adjacent tissue were carried out in 29 patients with carcinoma of the larynx after preoperative irradiation with fast neurons at a total focal dose 5.6 Gy alone or in combination with gamma therapy. Pronounced pathomorphosis was established in all the cases, up to a full disappearance of the tumor in 2 patients, the degree of pathomorphosis did not depend on location, macroscopic form of growth, degree of dissemination. No changes were found in the wall of the larynx outside the tumor.

Combined Modality Therapy↗

Fission reactor neutron sources for neutron capture therapy--a critical review.

The status of fission reactor-based neutron beams for neutron capture therapy (NCT) is reviewed critically. Epithermal neutron beams, which are favored for treatment of deep-seated tumors, have been constructed or are under construction at a number of reactors worldwide. Some of the most recently constructed epithermal neutron beams approach the theoretical optimum for beam purity. Of these higher quality beams, at least one is suitable for use in high through-put routine therapy. It is concluded that reactor-based epithermal neutron beams with near optimum characteristics are currently available and more can be constructed at existing reactors. Suitable reactors include relatively low power reactors using the core directly as a source of neutrons or a fission converter if core neutrons are difficult to access. Thermal neutron beams for NCT studies with small animals or for shallow tumor treatments, with near optimum properties have been available at reactors for many years. Additional high quality thermal beams can also be constructed at existing reactors or at new, small reactors. Furthermore, it should be possible to design and construct new low power reactors specifically for NCT, which meet all requirements for routine therapy and which are based on proven and highly safe reactor technology.

Animals↗

Lithium neutron producing target for BINP accelerator-based neutron source.

Pilot innovative accelerator-based neutron source for neutron capture therapy is under construction now at the Budker Institute of Nuclear Physics, Novosibirsk, Russia. One of the main elements of the facility is lithium target, that produces neutrons via threshold (7)Li(p,n)(7)Be reaction at 25 kW proton beam with energies 1.915 or 2.5 MeV. In the present report, the results of experiments on neutron producing target prototype are presented, the results of calculations of hydraulic resistance for heat carrier flow and lithium layer temperature are shown. Calculation showed that the lithium target could run up to 10 mA proton beam before melting. Choice of target variant is substantiated. Program of immediate necessary experiments is described. Target design for neutron source constructed at BINP is presented. Manufacturing the neutron producing target up to the end of 2004 and obtaining a neutron beam on BINP accelerator-based neutron source are planned during 2005.

Boron Neutron Capture Therapy↗

Enhancement of a 252Cf-based neutron beam via subcritical multiplication for neutron capture therapy.

Previous studies indicated that an epithermal-neutron beam based on bare 252Cf is not feasible for neutron capture therapy (NCT). It was reported that a clinically useful epithermal-neutron beam requires a minimum of 1.0 g of 252Cf, which is more than twice the US current annual supply. However, it was reasoned that the required quantity of 252Cf could be dramatically reduced when used with a subcritical multiplying assembly (SMA). This reasoning is based on the assumption that the epithermal-neutron beam intensity for NCT is directly proportional to the fission neutron population, and that the neutron multiplying factor of the SMA can be estimated by 1/(1 - k(eff)). We have performed detailed Monte Carlo calculations to investigate the validity of the above reasoning. Our results show that 1/(1 - k(eff)) grossly overestimates the beam enhancement factor for NCT. For example, Monte Carlo calculations predict a beam enhancement factor of 6.0 for an optimized SMA geometry with k(eff) = 0.968. This factor is much less than 31 predicted by 1/(1 - k(eff)). The overestimation is due to the fact that most of the neutrons produced in the SMA are self-shielded, whereas self-shielding is negligible in a bare 252Cf source. Since the beam intensity of a 0.1 g 252Cf with the optimized SMA enhancement is still more than an order of magnitude too low compared to the existing reactor beams, we conclude that the enhancement via an SMA for a 252Cf-based epithermal-neutron beam is inadequate for NCT.

Californium↗

The requirements and development of neutron beams for neutron capture therapy of brain cancer.

One of the two overriding conditions for successful BNCT is that there must be a sufficient number of thermal neutrons delivered to each of the boronated cells in the tumour bed (target volume). Despite the poor experience with BNCT in the USA some 40 years ago, the continued apparent success of BNCT in Japan since 1968, lead indirectly to the re-start of clinical trials on BNCT in 1994 at both Brookhaven and MIT. Similar trials will start soon at Petten in Europe. At other centres worldwide, many neutron beam designs are being proposed with either thermal or epithermal neutrons, emanating predominantly from nuclear research reactors. It is apparent that whilst the success of BNCT depends on a suitable neutron beam, there is a diversity in available designs, as well as each proposed type of neutron source, with consequently different characteristics of the emergent neutron beam. The paper presents the historical development of neutron beams used for BNCT, addresses the requirements on the types of beams, describes some of the existing designs and other proposals elsewhere and lastly, considers the broader requirements in designing NCT facilities. The focus of the paper is on treatment of brain cancer, neutron beam requirements for other types of cancer may vary.

Boron Neutron Capture Therapy↗

Self-shielding effects in neutron spectra measurements for neutron capture therapy by means of activation foils.

The design and optimisation of a neutron beam for neutron capture therapy (NCT) is accompanied by the neutron spectra measurements at the target position. The method of activation detectors was applied for the neutron spectra measurements. Epithermal neutron energy region imposes the resonance structure of activation cross sections resulting in strong self-shielding effects. The neutron self-shielding correction factor was calculated using a simple analytical model of a single absorption event. Such a procedure has been applied to individual cross sections from pointwise ENDF/B-VI library and new corrected activation cross sections were introduced to a spectra unfolding algorithm. The method has been verified experimentally both for isotropic and for parallel neutron beams. Two sets of diluted and non-diluted activation foils covered with cadmium were irradiated in the neutron field. The comparison of activation rates of diluted and non-diluted foils has demonstrated the correctness of the applied self-shielding model.

Absorption↗

Development and calculation of an energy dependent normal brain tissue neutron RBE for evaluating neutron fields for BNCT.

In Boron Neutron Capture Therapy (BNCT) of malignant brain tumors, the energy dependence of a clinically relevant Relative Biological Effectiveness (RBE) for epithermal neutrons, RBE(En), is important in neutron field design. In the first half of this paper, we present the development of an expression for the energy dependent normal-tissue RBE, RBE(En). We then calculate a reasonable estimate for RBE(En) for adult brain tissue. In the second half of the paper, two separate RBE expressions are developed, one for the RBE of the neutrons that interact in tissue via the 14N(n,p)14C reaction, denoted RBE(N), and one for the RBE of the neutrons which interact in tissue via the 1H(n,n')1H reaction, denoted RBE(H). The absorbed-dose-averaged values of these expressions are calculated for the neutron flux spectrum in phantom for the Brookhaven Medical Research Reactor (BMRR) epithermal neutron beam. The calculated values, [RBE(norm)N] = 3.4 and [RBE(norm)H] = 3.2, are within 6% of being equal, and support the use of equal values for RBEN and RBE(H) by researchers at Brookhaven National Laboratory (BNL). Finally, values of [RBE(norm)N] and [RBE(norm)H], along with the absorbed-dose-averaged RBE for brain, [RBE(norm)b], were calculated as a function of depth along the centerline of an ellipsoidal head phantom using flux spectra calculated for our Accelerator-Based Neutron Source (ABNS). These values remained essentially constant with depth, supporting the use of constant values for RBE, as is done at BNL.

Absorption↗

Comparison of measured parameters from a 24-keV and a broad spectrum epithermal neutron beam for neutron capture therapy: an identification of consequential parameters.

Epithermal neutron beams are under development in a number of locations in the U.S. and abroad. The increased penetration in tissue provided by these neurons should circumvent problems associated with the rapid attenuation of thermal neutron beams encountered in previous clinical trials of neutron capture therapy (NCT). Physical and radiobiological experiments with two "intermediate energy" or "epithermal" beams have been reported. A comparison is made here between the 24-keV iron-filtered beam at Harwell, England, and the broad-spectrum Al2 O3 moderated beam at the Brookhaven Medical Research Reactor (BMRR). In addition, parameters which are relevant for NCT, and which are best suited for evaluation and comparison of beams, are discussed. Particular attention is paid to the mean neutron energy which can be tolerated without significant reduction of therapeutic gain (TG), where TG is the ratio of tumor dose to maximum normal tissue dose. It is suggested that the simplest and most meaningful parameters for comparison of beam intensity and purity are the epithermal neutron fluence rate, and the fast neutron dose per epithermal neutron (4.2 X 10(-11) rad/neutron for the broad-spectrum beam and 29 X 10(-11) rad/neutron for the 24-keV beam). While the Al2O3 beam is close to optimal, the 24-keV beam produces a significant fast neutron dose which results in a lower TG.(ABSTRACT TRUNCATED AT 250 WORDS)

Biophysical Phenomena↗

Relative biological effectiveness measurements using murine lethality and survival of intestinal and hematopoietic stem cells after fermilab neutrons compared to JANUS reactor neutrons and 60Co gamma rays.

The relative biological effectiveness (RBE) of the 25-MeV (average energy) neutron beam at the Fermi National Accelerator Laboratory was measured using murine bone marrow (LD50/30) and gut (LD50/6) lethality and killing of hematopoietic colony forming units (CFU-S) or intestinal clonogenic cells (ICC). The reference radiation was 60Co gamma rays. The LD50/30 and LD50/6 for mice exposed to the Fermilab neutron beam were 6.6 and 8.7 Gy, respectively, intermediate between those of JANUS neutrons and 60Co gamma rays. The D0 values for CFU-S and ICC were 47 cGy and 1.05 Gy, respectively, also intermediate between the lowest values found for JANUS neutrons and the highest values found after 60Co gamma rays. The split-dose survival ratios for CFU-S at intervals of 1-6 hr between doses were essentially 1.0 for both neutron sources, while the corresponding split-dose survival ratio for 60Co gamma rays was consistantly above 1, reaching a maximum of 1.7 with a 1-hr interval between doses. The 3-hr split-dose survival ratios for ICC were 1.0 for JANUS neutrons, 1.85 for Fermilab neutrons, and 6.5 for 60Co gamma rays. The RBE estimates for LD50/30 were 1.5 and 2.3 for Fermilab and JANUS neutrons, respectively. Based on LD50/6, the RBEs were 1.9 (Fermilab) and 3.0 (JANUS). The RBEs for CFU-S D0 were 1.4 (Fermilab) and 1.9 (JANUS) and for jejunal microcolony D0 1.4 (Fermilab) and 2.8 (JANUS).

Animals↗

Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy.

A new thermal neutron monitor for boron neutron capture therapy was developed in this study. We called this monitor equipped boron-loaded plastic scintillator that uses optical fiber for signal transmission as an [scintillator with optical fiber] SOF detector. A water phantom experiment was performed to verify how the SOF detector compared with conventional method of measuring thermal neutron fluence. Measurements with a single SOF detector yielded indistinguishable signals for thermal neutrons and gamma rays. To account for the gamma ray contribution in the signal recorded by the SOF detector, a paired SOF detector system was employed. This was composed of an SOF detector with boron-loaded scintillator and an SOF detector with a boron-free scintillator. The difference between the recorded counts of these paired SOF detectors was used as the measure of the gamma ray contribution in the measured neutron fluence. The paired SOF detectors were ascertained to be effective in measuring thermal neutron flux in the range above 10(6)(n/cm(2)/s). Clinical trials using paired SOF to measure thermal neutron flux during therapy confirmed that paired SOF detectors were effective as a real-time thermal neutron flux monitor.

Boron Neutron Capture Therapy↗

Neutron and gamma-irradiation of bacteriophage M13 DNA: use of standard neutron irradiation facility (SNIF).

We describe here the use of the Van de Graaff accelerator as a source of high energy neutrons for biological irradiation. Single-stranded bacteriophage M13 DNA was chosen as the system to determine the relative biological effectiveness of monoenergetic neutrons. A Standard Neutron Irradiation Facility (SNIF) was established using a 3 MV Van de Graaff accelerator. The 2D (d,n)3He nuclear reaction was used to produce neutron fluxes of 3 x 10(8) cm 2 sec-1 yielding dose rates as high as 50 Gy h-1. A detailed description of the neutron source, neutron fluence measurement, dose calculation and calibration are included. Exposure of single-stranded bacteriophage M13 DNA to 90 Gy of neutrons reduced survival to 0.18% of the unirradiated value. 500 Gy of gamma-rays were required for the same level of killing, and RBE was estimated at 6 based on Do values. Determination of the extent of DNA damage after exposure to cleavage using gel electrophoresis, gave RBE values of 6-8 which was very similar to that observed for bacteriophage survival. The facility described here provides a reproducible source of high energy monoenergetic neutrons and dose levels suitable for experiments designed to measure DNA damage and effects on DNA synthesis.

Coliphages↗

Dose distributions in a human head phantom for neutron capture therapy using moderated neutrons from the 2.5 meV proton-7Li reaction or from fission of 235U.

The feasibility of neutron capture therapy (NCT) using an accelerator-based neutron source of the 7Li(p,n) reaction produced by 2.5 MeV protons was investigated by comparing the neutron beam tailored by both the Hiroshima University radiological research accelerator (HIRRAC) and the heavy water neutron irradiation facility in the Kyoto University reactor (KUR-HWNIF) from the viewpoint of the contamination dose ratios of the fast neutrons and the gamma rays. These contamination ratios to the boron dose were estimated in a water phantom of 20 cm diameter and 20 cm length to simulate a human head, with experiments by the same techniques for NCT in KUR-HWNIF and/or the simulation calculations by the Monte Carlo N-particle transport code system version 4B (MCNP-4B). It was found that the 7Li(p,n) neutrons produced by 2.5 MeV protons combined with 20, 25 or 30 cm thick D20 moderators of 20 cm diameter could make irradiation fields for NCT with depth-dose characteristics similar to those from the epithermal neutron beam at the KUR-HWNIF.

Head↗