Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microdialysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Distribution of spin-trapping compounds in rat blood and brain: in vivo microdialysis determination.

Microdialysis was utilized to determine blood and brain distribution of spin-trapping nitrone compounds in the rat following intraperitoneal administration. In vivo quantitation by high-pressure liquid chromatography (HPLC) analysis, in vitro calibration of microdialysis probes, optimum perfusion rate, and the relationship of microdialysis sample recovery to tissue levels were evaluated in detail. The microdialysis sampling and HPLC analysis provided on-line, within-animal pharmacokinetic time-course determinations. At equimolar concentrations, 150 mg/kg alpha-phenyl-N-tert-butyl nitrone (PBN) or 165 mg/kg alpha-4-pyridyl-N-oxide N-tert-butyl nitrone (POBN) reached a similar, steady-state venous blood concentration of 224 +/- 21 microM and 210 +/- 10 microM, respectively. The POBN steady-state brain concentration was 149 +/- 9 microM, a significantly (p < .05) lower concentration than in the blood. In contrast, the brain concentration of PBN was 331 +/- 25 microM, significantly (p < .05) higher than its concentration in the blood. The increased brain distribution/penetration of PBN was attributed to its greater lipophilicity as measured by its octanol/water partition coefficient. All microdialysis results were validated by direct measurement of blood and brain levels at steady-state using conventional extraction procedures and assays. Also, the amount of tissue/cell bound versus unbound nitrones was determined by comparing the microdialysis "dialyzable" fraction with the total amount from whole tissue extracts. These data demonstrate that on-line determinations of nitrone spin-trap brain penetration/levels can be carried out accurately using in vivo microdialysis. The implication of these results for potential use of the microdialysis technique for detection of free radical products in in vivo animal models is discussed.

Animals↗

Estimation of in-vivo neurotransmitter release by brain microdialysis: the issue of validity.

Although microdialysis is commonly understood as a method of sampling low molecular weight compounds in the extracellular compartment of tissues, this definition appears insufficient to specifically describe brain microdialysis of neurotransmitters. In fact, transmitter overflow from the brain into dialysates is critically dependent upon the composition of the perfusing Ringer. Therefore, the dialysing Ringer not only recovers the transmitter from the extracellular brain fluid but is a main determinant of its in-vivo release. Two types of brain microdialysis are distinguished: quantitative micro-dialysis and conventional microdialysis. Quantitative microdialysis provides an estimate of neurotransmitter concentrations in the extracellular fluid in contact with the probe. However, this information might poorly reflect the kinetics of neurotransmitter release in vivo. Conventional microdialysis involves perfusion at a constant rate with a transmitter-free Ringer, resulting in the formation of a steep neurotransmitter concentration gradient extending from the Ringer into the extracellular fluid. This artificial gradient might be critical for the ability of conventional microdialysis to detect and resolve phasic changes in neurotransmitter release taking place in the implanted area. On the basis of these characteristics, conventional microdialysis of neurotransmitters can be conceptualized as a model of the in-vivo release of neurotransmitters in the brain. As such, the criteria of face-validity, construct-validity and predictive-validity should be applied to select the most appropriate experimental conditions for estimating neurotransmitter release in specific brain areas in relation to behaviour.

Journal Article↗

Measurement of drug release from microcarriers by microdialysis.

The purpose of this study was to examine the feasibility of the microdialysis sampling technique as a method to precisely and conveniently measure drug release from microcarrier systems such as liposomes and microspheres. Release of 5-fluorouracil (5-FU) from liposomes and microspheres was evaluated in vitro using microdialysis. Retrodialysis calibration using 5-chlorouracil (5-CU) was performed in conjunction with on-line HPLC analysis. At a microdialysis perfusate flow rate of 0.5 muL/min, concurrent 5-FU gain and 5-CU loss ranged from 72% to 75%, while concurrent 5-FU loss and 5-CU ranged from 69% to 71%. After calibration, simultaneous 5-FU release profiles were obtained by continuous microdialysis and discrete equilibrium dialysis sampling using a side-by-side diffusion apparatus. Release rates were characterized by a first-order release model. The release rate constants for a representative liposomal formulation were 0.30 and 1.85/h by microdialysis in the acceptor and donor compartments, respectively, and 0.39/h by equilibrium dialysis in the acceptor compartment. The calculated release rate constant determined by equilibrium dialysis in the donor compartment (1.98/h) agrees with that determined by microdialysis (1.85/h) when the resistance of the equilibrium dialysis membrane with associated first-order rate constant of transfer of 0.42/h is taken into account. Release profiles of 5-FU from a number of different liposome and microsphere formulations were determined. The results indicate that a convenient and reproducible characterization of drug release from various liposome and microsphere formulations is readily obtainable by microdialysis.

1,2-Dipalmitoylphosphatidylcholine↗

Experimental and theoretical microdialysis studies of in situ metabolism.

Microdialysis sampling was performed to monitor localized metabolism in vivo and in vitro. A mathematical model that accounts for analyte mass transport during microdialysis sampling was used to predict metabolite concentrations in the microdialysis probe during localized metabolism experiments. The model predicts that metabolite concentrations obtained in the microdialysis probe are a function of different experimental parameters including membrane length, perfusion fluid flow rate, and sample diffusive and kinetic properties. Different microdialysis experimental parameters including membrane length and perfusion fluid flow rate were varied to affect substrate extraction efficiency (E(d)), or loss to the sample matrix, in vivo and in vitro. Local hepatic metabolism was studied in vivo in male Sprague-Dawley rats by infusing acetaminophen through the microdialysis probe. Acetaminophen sulfate concentrations increased linearly with respect to acetaminophen E(d) in contrast to modeling predictions. Xanthine oxidase was used as an in vitro model of localized metabolism. In vitro experimental results partially matched modeling predictions for 10-mm probes. These results suggest that monitoring local metabolism using microdialysis sampling is feasible. It is important to consider system parameters such as dialysis flow rate, membrane length, and sample properties because these factors will affect analyte concentrations obtained during local metabolism experiments.

Animals↗

Consequences of inspired oxygen fraction manipulation on myocardial oxygen pressure, adenosine and lactate concentrations: a combined myocardial microdialysis and sensitive oxygen electrode study in pigs.

Adenosine is a potent vasodilator whose concentration has been shown to increase in cardiac tissue in response to hypoxia. However, the time-dependent relationship between the levels of myocardial interstitial adenosine and tissue oxygenation has not yet been completely established. Therefore, the purpose of this study was to investigate the complex relationship between tissue myocardial oxygen tension (PtiO(2)) and interstitial myocardial adenosine and lactate concentrations by developing a new technique which combines a cardiac microdialysis probe and a Clark-type P O(2)electrode. The combined and the single microdialysis probes were implanted in the left ventricular myocardium of anesthetized pigs. The consequences of the combined use of microdialysis and P O(2)probes on myocardial PtiO(2)and microdialysis performances against glucose were evaluated. A moderate but significant reduction in the relative recovery against glucose of the combined probe was observed when compared to that of the single microdialysis probe (42+/-2 v 32+/-1%, mean+/-S.E. M.n=5 P<0.05), at 2microl/min microdialysis probe perfusion flow. Similarly, myocardial oxygen enrichment, measured by the P O(2)electrode, was negligible when microdialysis probe perfusion flow was 2microl/min. Systemic hypoxia (FiO(2)=0.08) resulted in a significant decrease in PtiO(2)from 30+/-4 to 11+/-2 mmHg, limited increase in coronary blood flow (CBF), and a significant increase in myocardial adenosine and lactate concentrations from 0.34+/-0.05 to 0.98+/-0.06micromol/l and from 0.45+/-0.05 to 0.97+/-0.06 mmol/l respectively (P<0.05). Increasing the FiO(2)to 0.3 restored the PtiO(2)and hemodynamic parameters to baseline values with no changes in interstitial adenosine and lactate concentrations. Nevertheless, myocardial interstitial adenosine remained significantly higher than baseline values. In conclusion, this study demonstrates the ability of a combined probe to measure simultaneously regional myocardial PtiO(2)and metabolite concentration during hypoxia. The hypoxia-induced increase in myocardial adenosine persists after correction of hypoxia. The physiological significance of this observation requires further studies.

Adenosine↗

Application of in vivo microdialysis to the study of cholinergic systems.

The application of in vivo microdialysis to the study of acetylcholine (ACh) release has contributed greatly to our understanding of cholinergic brain systems. This article reviews standard experimental procedures for dialysis probe selection and implantation, perfusion parameters, neurochemical detection, and data analysis as they relate to microdialysis assessments of cholinergic function. Particular attention is focused on the unique methodological considerations that arise when in vivo microdialysis is dedicated expressly to the recovery and measurement of ACh as opposed to other neurotransmitters. Limitations of the microdialysis technique are discussed, as well as methodological adaptations that may prove useful in overcoming these limitations. This is followed by an overview of recent studies in which the application of in vivo microdialysis has been used to characterize the basic pharmacology and physiology of cholinergic neurons. Finally, the usefulness of the microdialysis approach for testing hypotheses regarding the cholinergic systems' involvement in cognitive processes is examined. It can be concluded that, in addition to being a versatile and practical method for studying the neurochemistry of cholinergic brain systems, in vivo microdialysis represents a valuable tool in our efforts to better comprehend ACh's underlying role in a variety of behavioral processes.

Acetylcholine↗

In vivo microdialysis for nonapeptides in rat brain--a practical guide.

Microdialysis provides a direct approach to monitor changes in interneuronal communication by monitoring the fluctuation of local, extracellular concentrations of potential neurotransmitters/neuromodulators. The present article is based on more than 10 years experience in performing microdialysis experiments in freely moving animals with inexpensive self-made microdialysis probes and accessories for monitoring of intracerebral neuropeptide release. On the basis of this experience, we provide a guide for the construction of different types of microdialysis probes and their application. Furthermore, we give information about organizing and performing a microdialysis experiment that can easily be adapted to fit individual applications needs. Finally, on the basis of theoretical background information advantages as well as limitations of the microdialysis technique are discussed with the intent to provide help to potential users for designing an appropriate microdialysis experiment.

Animals↗

Cerebral microdialysis as a monitoring method in subarachnoid hemorrhage patients, and correlation with clinical events--a systematic review.

BACKGROUND: One of the goals in treating subarachnoid hemorrhage patients is to prevent or minimize vasospasm-induced ischemia. Intracerebral microdialysis is a rapidly developing tool to monitor physiological and pathophysiological changes in chemical processes associated with ischemia. OBJECTIVE: To determine the diagnostic accuracy of microdialysis in detecting ischemia or ischemic events in patients with subarachnoid hemorrhage. METHODS: A systematic review of clinical studies regarding microdialysis as a monitoring method in patients in the acute stage of subarachnoid hemorrhage was conducted by performing a MEDLINE search using the terms "subarachnoid hemorrhage", "brain ischemia", "intracranial aneurysm", "cerebrovascular accident" and "stroke". These were combined with a search on "microdialysis". The methodological quality of the studies was assessed independently by two reviewers. For each study the grades of recommendation were determined. RESULTS: The search yielded 73 publications of which 13 studies were analysed. The methodological quality of the studies was low,with only 3 studies fulfilling more than 50% of the criteria. Consequently the level of evidence was low. Of the internal validity criteria the characteristics of study populations were similar in most of the studies. The technical assessment varied considerably. A quantitative analysis (meta-analysis) could not be performed because of lack of sufficient data. A qualitative analysis yielded a positive impression with regard to the diagnostic accuracy of microdialysis in detecting ischemic events. CONCLUSION: There is a positive tendency to use microdialysis as a diagnostic tool for monitoring of ischemic events in subarachnoid hemorrhage patients. However, there is insufficient evidence for the routine use of microdialysis.

Cerebral Cortex↗

Brain microdialysis and its application for the study of animal behaviour.

Microdialysis is a sampling method that is used to determine the extracellular concentration of neurotransmitters in the brain. The method can be applied to conscious and unrestrained animals and is very suitable for the study of the chemistry of endogenous behaviour. This article reviews the contribution that microdialysis made to our understanding of the chemistry of behaviour. Methodological and practical considerations such as the implantation time and the use of guide cannulas are reviewed. The question whether neurotransmitters and related metabolites in dialysates reflect true synaptic release is critically discussed. There is much evidence that dopamine, noradrenaline, acetylcholine and serotonin in dialysates are related to neurotransmission, but there is serious doubt whether this is the case with amino acid transmitters such as GABA, glutamate and aspartate. Until now far over 100 papers appeared that used microdialysis in behavioural studies. Behavioural activation, the sleep-awake cycle and diurnal rhythms were subject of several of these studies. Various workers have described neurochemical changes in the brain that are related to feeding. Other studies were concerned with sexual behaviour and the sexual cycle in females. Parturition, maternal behaviour and offspring recognition have been studied in a series of microdialysis studies carried out in sheep. An overview is given of the microdialysis studies that were carried out to understand the biochemistry of stress. In this respect dopamine and noradrenaline have received much attention. A great number of microdialysis studies dealt with the role of dopamine in self-stimulation, reward and aversive emotions. It is concluded that microdialysis is at presently the most versatile and practical method to study the chemistry of behaviour and it is to be expected that it will soon be a routine methodology in behavioural research. Finally, perspectives and possible future developments of the methods are discussed.

Animals↗

Sampling glutamate and GABA with microdialysis: suggestions on how to get the dialysis membrane closer to the synapse.

Microdialysis is currently optimized to sample the extrasynaptic pool. As such, the technique has facilitated discovery of ischemia-induced excitotoxic glutamate overflow (Benveniste H, Drejer J, Schousboe A, Diemer NH, 1987, Regional cerebral glucose phosphorylation and blood flow after insertion of a microdialysis fiber through the dorsal hippocampus in the rat. J. Neurochem., 49, 729-734) and adenosinergic sleep drive (Porkka-Heiskanen T, Strecker RE, Thakkar M, Bjorkum AA, Greene RW, McCarley RW, 1997, Adenosine: a mediator of the sleep-inducing effects of prolonged wakefulness. Science, 276 (5316), 1265-1268); and is proving essential for clinical monitoring of glutamate and cellular metabolites in stroke and head trauma (Sarrafzadeh AS, Sakowitz OW, Kiening KL, Benndorf G, Lanksch WR, Unterberg AW. Bedside microdialysis: a tool to monitor cerebral metabolism in subarachnoid hemorrhage patients? Crit. Care Med. 2002, 30 (5): 1062-1070). Study of the origin of extrasynaptic glutamate sampled with microdialysis has advanced understanding of extrasynaptic signal processing (Baker DA, Xi ZX, Shen H, Swanson CJ, Kalivas PW. The origin and neuronal function of in vivo nonsynaptic glutamate. J. Neurosci. 2002, 22 (20): 9134-9141; Baker DA, McFarland K, Lake RW, Shen H, Tang XC, Toda S, Kalivas PW, 2003, Neuroadaptations in cystine-glutamate exchange underlie cocaine relapse. Nat. Neurosci., 6, 743-749) in the CNS. Microdialysis studies furthermore demonstrate that synaptic pools of some neurotransmitters spill into the extrasynaptic space. For this reason, microdialysis has provided a window into the synaptic pool that has significantly advanced understanding of neurotransmitter control of behavior (Tanda G, Pontieri FE, Di Chiara G, 1997, Cannabinoid and heroin activation of mesolimbic dopamine transmission by a common mu1 opioid receptor mechanism. Science, 276, 2048-2050). Nonetheless, ability to sample synaptic pools of neurotransmitters is limited. Here we summarize evidence that microdialysis often fails to sample synaptic pools of neurotransmitters, such as glutamate and GABA because of rapid clearance and limited diffusion of these neurotransmitters from the synapse. Moreover, we consider means to move the dialysis membrane closer to the synapse to facilitate sampling of the synaptic pool of these neurotransmitters by minimizing tissue trauma, decreasing probe size and increasing temporal resolution.

Animals↗

In vitro characterization of an in situ microdialysis sampling assay for elastase activity detection.

A microdialysis sampling method has been developed to detect the in vitro presence of a proteolytic enzyme, porcine elastase, external to a microdialysis probe. Elastase converts the substrate, succinyl(Ala)(3)-p-nitroanilide (suc(Ala)(3)-p-NA), to p-nitroaniline (p-NA). The substrate, suc(Ala)(3)-p-NA, was locally delivered through the microdialysis probe to external solutions containing different elastase activities (0.025-0.5 units/mL). The product, p-NA, was recovered back into the probe. Dialysates containing both suc(Ala)(3)-p-NA and p-NA were quantified using HPLC-UV. Different microdialysis suc(Ala)(3)-p-NA extraction efficiencies (EE) were observed among different elastase-containing solutions (buffer and 0.3% agar solutions). The p-NA concentrations recovered back into the microdialysis probe correlated with the elastase activity external to the microdialysis probe. The greatest fraction of p-NA recovered as compared to substrate lost occurred with the highest flow rate used (5.0 microL/min). However, the highest concentrations of p-NA recovered occurred at the lowest flow rates. This method may allow for microdialysis sampling to be used as a means to study localized enzyme activity.

Agar↗

Effects of tissue trauma on the characteristics of microdialysis zero-net-flux method sampling neurotransmitters.

Microdialysis has been used for studying neurochemistry in brain regions that respond to afferent inputs or administered drugs. As the knowledge derived from and concerning microdialysis grows, so do the concerns over its invasiveness and, hence, the credibility of resulting data. Recent experimental and theoretical studies impugned the validity of the microdialysis zero-net-flux (ZNF) method in measuring brain extracellular neurotransmitters, suggesting that the tissue trauma resulting from probe implantation seriously compromises its worth. This paper developed a theoretical model to study the influences of two categories of tissue trauma on microdialysis ZNF operation: (1) morphological alterations in tissue extracellular structure and (2) physiological impairment of neurotransmitter release and uptake processes. Model results show that alterations of tissue extracellular structure negligibly affect the accuracy of the ZNF method in determining the basal level of extracellular neurotransmitter but do affect the fundamental characteristics of microdialysis: the extraction efficiency and relative recovery. An inhibited or damaged neurotransmitter uptake process always decreases the efficiency of microdialysis extraction, but rise of the relative recovery of neurotransmitters with the same uptake inhibition/damage occurs only when there is far more damage to the neurotransmitter release than to the uptake process in the tissue. A criterion for this rising trend of microdialysis relative recovery is discussed in terms of trauma parameters and neurotransmitter uptake inhibition.

Brain Injuries↗

Microdialysis in peripheral tissues.

The objective of this review is to survey the recent literature regarding the applications of microdialysis in pharmacokinetic studies and facilitating many other studies in peripheral tissues such as muscle, subcutaneous adipose tissue, heart, lung, etc. It has been reported extensively that microdialysis is a useful technique for monitoring free concentrations of compounds in extracellular fluid (ECF), and it is gaining popularity in pharmacokinetic and pharmacodynamic studies, both in experimental animals and humans. The first part of this review discusses the use of microdialysis technique for ECF sampling in peripheral tissues in animal studies. The second part of the review describes the use of microdialysis for ECF sampling in peripheral tissues in human studies. Microdialysis has been applied extensively to measure both endogenous and exogenous compounds in ECF. Of particular benefit is the fact that microdialysis measures the unbound concentrations in the peripheral tissue fluid which have been shown to be responsible for the pharmacological effects. With the increasing number of applications of microdialysis, it is obvious that this method will have an important place in studying drug pharmacokinetics and pharmacodynamics.

Adipose Tissue↗

Methodological issues in microdialysis sampling for pharmacokinetic studies.

Microdialysis is an in vivo technique that permits monitoring of local concentrations of drugs and metabolites at specific sites in the body. Microdialysis has several characteristics, which makes it an attractive tool for pharmacokinetic research. About a decade ago the microdialysis technique entered the field of pharmacokinetic research, in the brain, and later also in peripheral tissues and blood. Within this period much has been learned on the proper use of this technique. Today, it has outgrown its child diseases and its potentials and limitations have become more or less well defined. As microdialysis is a delicate technique for which experimental factors appear to be critical with respect to the validity of the experimental outcomes, several factors should be considered. These include the probe; the perfusion solution; post-surgery interval in relation to surgical trauma, tissue integrity and repeated experiments; the analysis of microdialysate samples; and the quantification of microdialysate data. Provided that experimental conditions are optimized to give valid and quantitative results, microdialysis can provide numerous data points from a relatively small number of individual animals to determine detailed pharmacokinetic information. An example of one of the added values of this technique compared with other in vivo pharmacokinetic techniques, is that microdialysis reflects free concentrations in tissues and plasma. This gives the opportunity to assess information on drug transport equilibration across membranes such as the blood-brain barrier, which already has provided new insights. With the progress of analytical methodology, especially with respect to low volume/low concentration measurements and simultaneous measurement of multiple compounds, the applications and importance of the microdialysis technique in pharmacokinetic research will continue to increase.

Animals↗

Blood microdialysis in pharmacokinetic and drug metabolism studies.

Microdialysis is a sampling technique allowing measurement of endogenous and exogenous substances in the extracellular fluid surrounding the probe. In vivo microdialysis sampling offers several advantages over conventional methods of studying the pharmacokinetics and metabolism of xenobiotics, both in experimental animals and humans. In the first part of this review article various practical aspects related to blood microdialysis will be discussed, such as: probe design, surgical implantation techniques, methods to determine the in vivo relative recovery of the analyte of interest by the probe, special analytical considerations related to small volume microdialysate samples, and pharmacokinetic calculations based on microdialysis data. In the second part of this review a few selected applications of in vivo microdialysis sampling to investigate pharmacokinetic processes are briefly discussed: determination of in vivo plasma protein binding in small laboratory animals, distribution of drugs across the blood-brain barrier, the use of microdialysis sampling to study biliary excretion and enterohepatic cycling, blood microdialysis sampling in man and in the mouse, and in vivo drug metabolism studies.

Animals↗

Extracellular glutamate changes in rat striatum during ischemia determined by a novel dialysis electrode and conventional microdialysis.

Our newly developed method using a dialysis electrode has made it possible to perform real time monitoring of extracellular glutamate concentration ([Glu]e) utilizing the oxygen-independent reaction with glutamate oxidase and ferrocene. In this study, we therefore, investigated [Glu]e changes during brain ischemia using both the conventional microdialysis method and the dialysis electrode method. A comparison between our newly developed dialysis electrode and conventional microdialysis methods provided the following results. When the conventional microdialysis method was employed: (1) the elevation of [Glu]e during complete global ischemia was delayed; and (2) the elevation of concentration and reuptake of glutamate were delayed during 10-min transient ischemia, and the elevation of [Glu]e reached a maximum later using conventional microdialysis than using our dialysis electrode. (3) The biphasic [Glu]e elevation of glutamate concentration detected using the dialysis electrode method was not observed using the conventional microdialysis method. It was additionally investigated why the conventional microdialysis method provides inferior time resolution. In this study, we also demonstrated with the chromatographic SMART procedure coupled to UV detection that biogenic substances, i.e. low molecular weight proteins and peptides, are released during ischemic injury, and they may cause a delay in the time resolution in the microdialysis method.

Animals↗

Microdialysis measurement of glucose in subcutaneous adipose tissue up to three weeks in type 1 diabetic patients.

BACKGROUND: Microdialysis of subcutaneous adipose tissue may provide an opportunity to monitor glucose continuously, when the device is connected to an extracorporal glucose sensor. We assessed whether our microdialysis probes are capable of measuring adipose tissue glucose over a prolonged period in Type 1 diabetic patients. Furthermore, the relationship between abdominal skinfold thickness and glucose recovery and the effect of spontaneous glucose excursions on its recovery were evaluated. METHODS: Microdialysis probes were pairwise inserted subcutaneously into the abdominal fat and remained in situ for 3 weeks in eight Type 1 diabetic patients. At days 1, 3, 4, 8, 11, 16, and 18 of probe retention, glucose, as measured by microdialysis, was compared to capillary blood glucose concentrations during a 4 h period. The recovery of glucose obtained by microdialysis was expressed as a percentage of the capillary blood glucose concentration. RESULTS: Eleven of the 16 inserted probes (69%) were evaluable during the complete study. Recovery of glucose was lower at day 1 and 3 (51+/-23% and 56+/-18%, respectively, mean+/-S.D.) compared to values found afterwards (67+/-19%, 72+/-13%, 76+/-14%, 71+/-16%, and 76+/-18%, for day 4, 8, 11, 16, and 18, respectively, for all P<0.05 vs. day 1 and 3). Skinfold thickness was inversely related to the overall 3 week glucose recovery (r=-0.76; P<0.03). Recovery was similar over a wide range of capillary blood glucose concentrations. CONCLUSIONS: Prolonged in vivo retention of microdialysis probes improves the recovery and lowers the variability of adipose tissue-sampled glucose in Type 1 diabetic patients. These findings show that microdialysis-based glucose measurements offer an opportunity for prolonged glucose monitoring.

Adipose Tissue↗

Microdialysis for the evaluation of penetration through the human skin barrier - a promising tool for future research?

The direct measurement of local drug concentration levels at discreet skin locations with minor trauma has recently become possible with the introduction of cutaneous microdialysis. Cutaneous microdialysis is an in vivo sampling technique for measuring solutes in the extracellular fluid of the dermis. When used in combination with other experimental approaches, for example with a variety of non-invasive techniques to describe the functional status of the skin (bioengineering methods), it may help investigators to gain new insights into the fields of skin diseases, metabolism and drug absorption/penetration. An important parameter to describe the efficacy of microdialysis is the relative recovery. This is the ratio between the concentration of a substance in the dialysate and the true extracellular concentration. Several methods are in common use to describe the relative recovery (no-net-flux method or retrodialysis). Parameters such as probe design, depth of the probe in the dermis, physico-chemical properties of the compound of interest, and analytical aspects are important factors influencing microdialysis. Microdialysis has been used to investigate the influence of penetration enhancers, vehicles or iontophoresis on percutaneous absorption, performed by in vivo studies in rats. In human volunteers, most of the experiments have been performed to study the kinetics of fast penetrating substances, e.g. nicotine, non-steroidal antiinflammatory drugs, local anaesthetics, or solvents. Problems have been encountered in the detection of lipophilic and highly protein-bound substances. Further, dermal metabolism and the influence of barrier perturbation on percutaneous absorption have been analyzed. Investigations suggest that microdialysis, in combination with traditional techniques, might give valuable information regarding the assessment of the penetration of drugs and other exogenous agents through the skin. In spite of the clearly defined and accepted advantages of microdialysis technology for studies of transdermal drug delivery, to date no standardized test procedure exists nor has the reproducibility of the results been evaluated. In the future, these problems have to be solved to enable this method to find its place in standard research.

Humans↗