Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microbubbles”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Nanointerrogation of ultrasonic contrast agent microbubbles using atomic force microscopy.

Predicting the acoustic response of an encapsulated microbubble to ultrasound requires an accurate assessment of the mechanical properties of the microbubble shell. Atomic force microscopy (AFM) provides an unprecedented spatial and force resolution of the order of Angstroms and subnanonewtons, respectively. It is introduced here as a means to interrogate microbubbles manufactured for ultrasonic imaging. The advantage of AFM over scanning electron microscopy (SEM) is that the microbubbles need not be subjected to a low temperature or low-pressure environment. The microbubbles were interrogated in a liquid environment, which could potentially be a simulated physiological environment. AFM was used in tapping mode imaging to reveal topographical detail of biSphere microbubbles. Because microbubbles are large objects compared with the overall size of usual AFM tips, a convolution between the AFM tip and the microbubble was typical of the acquired topographies. However, a part of the top half of the bubble was imaged with nanometer resolution, and roughness measurements are reported. Force-distance curves were captured using contact mode AFM. The range of stiffness or effective spring constant of biSphere was found to be between 1 and 6 N m(-1). In conclusion, the AFM is proposed here for the first time as a tool to image the surface of bubbles at the nanometer range in liquid and to perform reproducible measurements on the mechanical properties of individual microbubbles.

Biomechanical Phenomena↗

Ultrasound attenuation in encapsulated microbubble suspensions: The multiple scattering effects.

The phenomenon of image distortions caused by the multiple scattering (MS) effects of encapsulated microbubbles in ultrasoniqc imaging was experimentally found in previous studies (Soetanto and Chan 2000a), but its mechanism has not been fully understood. To study the MS effects of microbubbles in contrast imaging, two approaches are employed in this article--the effective medium approach initialized by Kargl (2002), which includes all the high-order rescattering of free bubbles, and the classic lowest-order approximation approach of Commander and Prosperetti (1989), which ignores the higher-order rescattering between bubbles. In this work, they are modified to model encapsulated microbubble suspensions, and the discrepancies in attenuation coefficients calculated by these two approaches, i.e., the higher-order rescattering of bubbles are defined as the measure of the MS effects of microbubbles. The intrinsic relations between the MS effects of microbubbles in suspensions and physical properties of the microbubbles, such as the bubble concentrations, sizes, and the shell thicknesses etc., are simulated and discussed. It is found that in suspensions for identical microbubbles >12 microm in size, the MS effects come to be significant when the bubble concentrations exceed 1 x 10(5) bubbles/mL. The MS effects of microbubbles with broad size spectrums are examined by simulating Soetanto and Chan's experiments. Also, the MS effects of UCAs in current ultrasonic imaging practice are discussed. The STARs and extinction cross-sections of different-sized individual encapsulated microbubbles are calculated for further investigations on the mechanism of the MS effects of UCAs.

Acoustics↗

Acoustic radiation force enhances targeted delivery of ultrasound contrast microbubbles: in vitro verification.

Recent research has shown that targeted ultrasound contrast microbubbles achieve specific adhesion to regions of intravascular pathology, but not in areas of high flow. It has been suggested that acoustic radiation can be used to force free-stream microbubbles toward the target, but this has not been verified for actual targeted contrast agents. We present evidence that acoustic radiation indeed increases the specific targeted accumulation of microbubbles. Lipid microbubbles bearing an antibody as a targeting ligand were infused through a microcapillary flow chamber coated with P-selectin as the target protein. A 2.0 MHz ultrasonic pulse was applied perpendicular to the flow direction. Microbubble accumulation was observed on the flow chamber surface opposite the transducer. An acoustic pressure of 122 kPa enhanced microbubble adhesion up to 60-fold in a microbubble concentration range of 0.25 x 10(6) to 75 x 106) ml(-1). Acoustic pressure mediated the greatest adhesion enhancement at concentrations within the clinical dosing range. Acoustic pressure enhanced targeting nearly 80-fold at a wall shear rate of 1244 s(-1), suggesting that this mechanism is appropriate for achieving targeted microbubble delivery in high-flow vessels. Microbubble adhesion increased with the square of acoustic pressure between 25 and 122 kPa, and decreased substantially at higher pressures.

Antibodies↗

Acoustic detection of controlled laser-induced microbubble creation in gelatin.

A high-frequency (85 MHz) acoustic technique is used to identify system parameters for controlled laser-induced microbubble creation inside tissue-mimicking, gelatin phantoms. Microbubbles are generated at the focus of an ultrafast 793-nm laser source and simultaneously monitored through ultrasonic pulse-echo recordings. Displayed in wavefield form, these recordings illustrate microbubble creation, and integrated backscatter plots provide specifics about microbubble characteristics and dissolution behavior. By varying laser parameters, including pulse fluence (or pulse energy flux, J/cm2), total number of pulses delivered, and the period between pulses, the size, lifetime, and dissolution dynamics of laser-induced microbubbles may be independently controlled. Pulse fluence is the main size-controlling parameter, whereas both increases in pulse fluence and pulse number can lengthen microbubble lifetime from tens to hundreds of milliseconds. In short, a microbubble of particular lifetime does not necessarily have to be of a particular size. Microbubble behavior, furthermore, is independent of pulse periods below a fluence-dependent threshold value, but it exhibits stochastic behavior if pulse repetition is too slow. These results demonstrate that laser pulse fluence, number, and period may be varied to deposit energy in a specific temporal manner, creating and stabilizing microbubbles with particular characteristics and, therefore, potential uses in sensitive acoustic detection and manipulation schemes.

Acoustics↗

[Targeted adhesion of platelet receptor-specific microbubble agent to thrombus in vitro].

OBJECTIVE: To examine the thrombus-targeting effect of platelet receptor-specific lipid microbubbles. METHODS: The targeted microbubbles were prepared by coupling Arg-Gly-Asp-Ser (RGDS) with the lipid microbubbles, which were added to the microthrombus generated by platelet aggregation. The effects of the targeted microbubbles on the ultrasonic signal was observed in an artificial thrombus model. RESULTS: The targeted microbubbles were adhesive to the microthrombus, while the non-targeted microbubbles did not possess this property. The ultrasonic signal of the thrombus border was enhanced significantly after the addition of the targeted microbubbles. CONCLUSIONS: Platelet receptor-specific microbubbles possess significant adhesive property to the thrombus and can improve signal-to-noise ratio of the thrombus, suggesting the potential value of the targeted microbubbles for clinical application in the diagnosis and treatment of thrombus.

Cell Adhesion↗

Value of intraoperative left ventricular microbubbles detected by transesophageal two-dimensional echocardiography in predicting neurologic outcome after cardiac operations.

To determine whether the presence or absence of left ventricular (LV) intracavitary microbubbles during cardiac surgery predicts neurologic sequelae, 82 patients undergoing cardiac surgery were studied using transesophageal 2-dimensional (2-D) echocardiography. Cross-sectional images were recorded just before and immediately after cardiopulmonary bypass and stop frames were reviewed for the presence of microbubbles, rated as: 0 = absent, 1 = fewer than 5/frame, 2 = 10 to 25/frame, 3 = too numerous to count. Microbubbles were detected after cardiopulmonary bypass in 34 patients (41%) and found more often in valvular or other intracardiac manipulations than in coronary revascularization, 30 of 40 vs 4 of 42, respectively (p less than 0.001). When grade 2 or 3 microbubbles were identified (22 of 34 patients), mechanical attempts to eradicate them were not successful. Postoperative follow-up in all patients revealed no new focal neurologic deficits. Prolonged encephalopathy (confusional state more than 72 hours) occurred in 4 of 48 patients with no detectable microbubbles and in 3 of 34 patients with microbubbles (difference not significant). Thus, intracavitary left ventricular microbubbles are often detected during cardiac operations, particularly during valve replacement, but are not predictive of postoperative neurologic complications. This is true even if microbubbles are densely concentrated; attempts to eradicate microbubbles are unsuccessful and may be unnecessary.

Cardiac Surgical Procedures↗

Optical and acoustical dynamics of microbubble contrast agents inside neutrophils.

Acoustically active microbubbles are used for contrast-enhanced ultrasound assessment of organ perfusion. In regions of inflammation, contrast agents are captured and phagocytosed by activated neutrophils adherent to the venular wall. Using direct optical observation with a high-speed camera and acoustical interrogation of individual bubbles and cells, we assessed the physical and acoustical responses of both phagocytosed and free microbubbles. Optical analysis of bubble radial oscillations during insonation demonstrated that phagocytosed microbubbles experience viscous damping within the cytoplasm and yet remain acoustically active and capable of large volumetric oscillations during an acoustic pulse. Fitting a modified version of the Rayleigh-Plesset equation that describes mechanical properties of thin shells to optical radius-time data of oscillating bubbles provided estimates of the apparent viscosity of the intracellular medium. Phagocytosed microbubbles experienced a viscous damping approximately sevenfold greater than free microbubbles. Acoustical comparison between free and phagocytosed microbubbles indicated that phagocytosed microbubbles produce an echo with a higher mean frequency than free microbubbles in response to a rarefaction-first single-cycle pulse. Moreover, this frequency increase is predicted using the modified Rayleigh-Plesset equation. We conclude that contrast-enhanced ultrasound can detect distinct acoustic signals from microbubbles inside of neutrophils and may provide a unique tool to identify activated neutrophils at sites of inflammation.

Contrast Media↗

Study on the lifetime and attenuation properties of microbubbles coated with carboxylic acid salts.

Four kinds of surfactants, sodium laurate, sodium myristate, sodium palmitate and sodium oleate were used to study the effects of surfactant coatings on the lifetime and attenuation of microbubbles. The changes in the size distribution of microbubbles prepared with these surfactants in saline were measured with a Coulter Multisizer (Coulter Electronics Ltd., Luton, UK). Frequency characteristics of ultrasonic attenuation of the microbubble suspensions were measured between 400 kHz and 6 MHz. From the changes in attenuation in the microbubble suspensions over time, it was found that the lifetime of microbubbles in a suspension also depends on the frequency of the irradiating ultrasound. The effect of surfactants on the frequency characteristics of attenuation was also studied, and characteristics of the surfactant coating, including shell elasticity and shell friction parameters were calculated from the measurement results. Microbubbles produced with sodium palmitate had the longest lifetime and the smallest average size. The shell had very little effect on the ultrasonic properties of microbubbles produced with sodium palmitate, suggesting that the sodium palmitate microbubbles behaved ultrasonically as free microbubbles.

Air↗

Interaction of diagnostic ultrasound with synthetic oligonucleotide-labeled perfluorocarbon-exposed sonicated dextrose albumin microbubbles.

The purpose of this study was to determine, first, whether the albumin on perfluorocarbon-exposed sonicated dextrose albumin microbubbles has retained its known ability to bind antisense oligonucleotides (DNA utilized to inhibit viral replication and intimal hyperplasia). The binding kinetics of synthetic antisense oligonucleotides to perfluorocarbon-exposed sonicated dextrose albumin microbubbles as well as to room air-containing sonicated dextrose albumin microbubbles were compared. Second, the effect of diagnostic ultrasound on this binding is unknown. The ability of diagnostic ultrasound to release synthetic antisense oligonucleotides from perfluorocarbon-exposed sonicated dextrose albumin microbubbles also was tested in vitro and in vivo in three dogs. Synthetic antisense oligonucleotides exhibited binding to perfluorocarbon-exposed sonicated dextrose albumin microbubbles much like that of native albumin but did not bind uniformly with room air-containing sonicated dextrose albumin microbubbles. Diagnostic ultrasound resulted in significant partitioning of synthetic antisense oligonucleotides into non-bubble containing regions after insonation in vitro as well as deposition of greater amounts of synthetic antisense oligonucleotides in the insonated kidney after intravenous injections of synthetic anti-sense oligonucleotide-labeled perfluorocarbon-exposed sonicated dextrose albumin microbubbles. We conclude that perfluorocarbon-exposed sonicated dextrose albumin microbubbles, unlike room air-containing sonicated dextrose albumin microbubbles, have bioactive albumin on their surface that can bind synthetic antisense oligonucleotides and then release them in the presence of diagnostic ultrasound.

Animals↗

Prolonging the ultrasound signal enhancement from thrombi using targeted microbubbles based on sulfur-hexafluoride-filled gas.

RATIONALE AND OBJECTIVES: The objective of this study is to develop and characterize new microbubbles based on lipids and sulfur hexafluoride (SF6) for targeting thrombi as an improved ultrasound contrast agent. MATERIALS AND METHODS: Bioconjugate ligands were inserted into the lipid-coated membranes of SF6 gas microbubbles, and their physicochemical properties were determined. Diagnostic efficacies of SF6-filled microbubbles and the contrast agent SonoVue (Bracco Imaging, Geneve, Switzerland) were compared in dogs. RESULTS: Suspensions of lyophilized powder were reconstituted by injecting saline containing 3.1 x 10(8) SF6 microbubbles/mL with a mean diameter of 4.4 microm. More than 90% of microbubbles had diameters between 1 and 10 microm. After reconstitution, echogenicity and microbubble characteristics were unchanged for 8 hours. Targeted microbubbles increased the echogenicity of thrombi significantly and provided a longer period of optimal signal enhancement compared with nontargeted microbubbles. CONCLUSIONS: Our thrombus-targeting microbubble contrast agent shows high echogenicity and stability and thereby enhances the visualization of intravascular thrombi and prolongs the duration of the diagnostic window.

Animals↗

Encapsulated ultrasound microbubbles: therapeutic application in drug/gene delivery.

Encapsulated gas microbubbles are well known as ultrasound contrast agents for medical ultrasound imaging. Nonetheless, not only do these microbubbles help to image, but they can also be used as drug/gene carriers. The microbubbles as drug/gene carriers have an average size less than that of red blood cells, i.e. they are capable of penetrating even into the small blood capillaries and releasing drug and genes under the action of ultrasound field. The application of ultrasound and microbubbles to targeted drug and gene delivery has been the subject of intense experimental research. Under exposure of sufficiently high-amplitude ultrasound, these targeted microbubbles would rupture, spewing drugs or genes, which are contained in its encapsulating layer, to targeted cells or tissues. Recently, targeting ligands are attached to the surface of the microbubbles (i.e. targeted-microbubbles), which have been widely used in cardiovascular system and tumor diagnosis and therapy. In this paper, the characterization of novel targeted ultrasonic contrast agents or microbubbles and their potential applications in drug delivery or gene therapy are reviewed.

Albumins↗

Targeted tissue transfection with ultrasound destruction of plasmid-bearing cationic microbubbles.

The aim of this study was to assess the relative efficacy and mechanism of gene transfection by ultrasound (US) destruction of plasmid-bearing microbubbles. Luciferase reporter plasmid was charge-coupled to cationic lipid microbubbles. Rat hindlimb skeletal muscle was exposed to intermittent high-power US during dose-adjusted intra-arterial (IA) or IV administration of plasmid-bearing microbubbles via the carotid artery or jugular vein, respectively. At 4 days, luciferase activity in US-exposed skeletal muscle was 200-fold greater with IA than with IV administration of plasmid-bearing microbubbles, and was similar to transfection achieved by IM injection of plasmid (positive control). No transfection occurred with US and IA injection of plasmid alone. Intravital microscopy of the cremaster muscle in mice following administration of microbubbles and US exposure demonstrated perivascular deposition of fluorescent plasmid, the extent of which was twofold greater for IA compared to IV injection. Electron microscopy demonstrated a greater extent of myocellular microporations in US-exposed muscle after IA injection of microbubbles. We conclude that muscle transfection by US destruction of plasmid-bearing cationic microbubbles is amplified by IA, rather than IV, injection of microbubbles due to greater extravascular deposition of plasmid and to greater extent of myocellular microporation.

Animals↗

Enhancement of enzymatic fibrinolysis with 2-MHz ultrasound and microbubbles.

BACKGROUND: Microbubbles used for echo-contrast agents accelerate enzymatic fibrinolysis of clots exposed to low-frequency ultrasound (US). It is not known whether microbubbles are also effective in enhancing high-frequency US-driven enzymatic fibrinolysis. METHODS AND RESULTS: Calibrated whole blood clots were exposed to US, or US and galactose-based microbubbles (Levovist), with or without recombinant tissue plasminogen activator (rt-PA) in an in-vitro flow system. We used low-intensity, 2-MHz, pulsed wave US. Relative weight reduction of clot +/- SD was 30.7 +/- 9.5% after exposure to microbubbles, rt-PA and US, 13.1 +/- 2.6% after exposure to rt-PA and US, 10.9 +/- 3.6% after exposure to microbubbles and US, and 6.1 +/- 1.9% after exposure to US alone. anova demonstrated a significant effect of rt-PA (P =0.001), microbubbles (P = 0.012), and interaction of both (P = 0.022). CONCLUSIONS: The application of galactose-based microbubbles (Levovist) strongly accelerates lysis of clots exposed to 2 MHz, low-intensity US in vitro both with and without rt-PA. The findings suggest a synergy between microbubbles and rt-PA. These methods routinely used for transcranial diagnostic applications have the potential to improve the efficacy of intravenous rt-PA in acute ischemic stroke.

Blood Coagulation↗

Incidence, time course, and characteristics of microbubble formation during radiofrequency ablation of pulmonary veins with an 8-mm ablation catheter.

BACKGROUND: Microbubble formation during pulmonary vein (PV) radiofrequency (RF) ablation of atrial fibrillation (AF) occurs relatively frequently. Prior studies have shown that microbubble formation may be associated with an increased risk of complications. However, the incidence, time course, and temperature characteristics of microbubble formation during AF ablation with an 8-mm catheter have not been prospectively described in humans. METHODS: We studied 46 (30 men, age 56+/-10 years) patients with AF who underwent RF ablation of PVs between January 2005 and December 2005 using an 8F, 8-mm Biosensetrade mark ablation catheter (Biosense-Webster, Diamond Bar, CA, USA). All patients underwent continuous intracardiac echocardiography (ICE). Microbubble patterns were classified as either type 1 (intermittent, scattered microbubble formation) or type 2 (explosive shower of dense microbubbles). Formation of any microbubbles was detected by ICE and the time, PV location, and electrode temperature were recorded. RESULT: A total of 1,479 (32+/-13, range 12-73) RF lesions were delivered to 167 veins. Twenty (2%) lesions were classified as type 2. Since the number of lesions resulting in type 2 bubbles was very small, only type 1 lesions were included in the final analysis. Thirty-nine (85%) patients had at least one lesion associated with bubble formation during ablation (mean: 7+/-7 lesions, range 1-28 lesions). Twenty-three percent (327) of the RF lesions resulted in bubble formation. RF generator power setting during lesions resulting in bubble formation was lower than lesions which did not result in bubble formation (47.9+/-7.4 W vs 49.7+/-7.1 W, P<0.001). Logistic regression analysis revealed a significant negative correlation (P<0.001) between RF generator power settings and a positive correlation between the generator temperature settings and formation of bubbles (both P<0.02). However, the maximum temperature attained was not different between lesions resulting in bubble formation (n=327) and those which did not result in bubble formation (n=1,139). Fifty-three (16%) of the lesions associated with bubble formation occurred within 2-10 seconds after RF was begun. Bubble formation was significantly more frequent in left superior PVs compared to the other PVs (left superior PV 27.3% left inferior PV 18.6%, right superior PV 20.5%, and right inferior PV 18.8%, P=0.005, left superior PV vs other PVs, P<0.001) even after adjustment for the other factors including generator power settings and the temperature setting. CONCLUSION: Bubble formation is common during RF ablation of PV with 8-mm tip catheter and can occur as early as 2 seconds after starting RF. RF generator power is negatively correlated with bubble formation while generator temperature settings are positively correlated with formation of bubbles. Microbubble formation is also more frequent with ablation of the left superior PV probably due to better catheter contact in that area.

Atrial Fibrillation↗

Monitoring response to anticancer therapy by targeting microbubbles to tumor vasculature.

PURPOSE: New strategies to detect tumor angiogenesis and monitor response of tumor vasculature to therapy are needed. Contrast ultrasound imaging using microbubbles targeted to tumor endothelium offers a noninvasive method for monitoring and quantifying vascular effects of antitumor therapy. We investigated the use of targeted microbubbles to follow vascular response of therapy in a mouse model of pancreatic adenocarcinoma. EXPERIMENTAL DESIGN: Microbubbles conjugated to monoclonal antibodies were used to image and quantify vascular effects of two different antitumor therapies in s.c. and orthotopic pancreatic tumors in mice. Tumor-bearing mice were treated with anti-vascular endothelial growth factor (VEGF) monoclonal antibodies and/or gemcitabine, and the localization of microbubbles to endoglin (CD105), VEGF receptor 2 (VEGFR2), or VEGF-activated blood vessels (the VEGF-VEGFR complex) was monitored by contrast ultrasound. RESULTS: Targeted microbubbles showed significant enhancement of tumor vasculature when compared with untargeted or control IgG-targeted microbubbles. Video intensity from targeted microbubbles correlated with the level of expression of the target (CD105, VEGFR2, or the VEGF-VEGFR complex) and with microvessel density in tumors under antiangiogenic or cytotoxic therapy. CONCLUSIONS: We conclude that targeted microbubbles represent a novel and attractive tool for noninvasive, vascular-targeted molecular imaging of tumor angiogenesis and for monitoring vascular effects specific to antitumor therapy in vivo.

Angiogenesis Inhibitors↗

Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine.

BACKGROUND AND PURPOSE: Destruction of microbubbles by transcutaneous low-frequency ultrasound (LFUS) has been used to lyse adjacent clot and recanalize acutely thrombosed vessels. LFUS with intraarterial microbubbles has been shown to lyse cerebral clot rapidly in pigs without thrombolytic drugs. We hypothesized that intravenous platelet-targeted microbubbles with LFUS may be a rapid noninvasive technique to recanalize thrombosed intracerebral vessels. METHODS: After angiography, 0.5 cc of autogenous thrombus was injected into 1 ascending pharyngeal artery of a pig, occluding it and the rete mirabile. These vessels connect the carotid to the internal carotid and are the main cerebral blood supply. Saline control or intravenous decafluorobutane-sonicated dextrose albumin microbubbles tagged with a subtherapeutic quantity of glycoprotein 2b/3a receptor inhibitor eptifibatide (75 U/kg plus 12 cc of microbubbles administered over 21 minutes), or eptifibatide control, was given with transcutaneous temporal LFUS (1 MHz at 2.0 W/cm2) for 24 minutes. Angiography followed with scoring of declotting and flow. The same protocol was repeated on the contralateral side with the other test fluid so each animal received a saline control and either tagged microbubble or eptifibatide alone. RESULTS: Fifteen pigs completed the protocol with a mean clot age of 4.6 hours. Using tagged microbubbles, 6 of 8 achieved success compared with 0 of 7 receiving eptifibatide alone (P=0.007) and 1 of 15 receiving saline alone (P=0.02). CONCLUSIONS: Intravenous platelet-targeted microbubbles combined with transcranial LFUS can rapidly open acute intracranial thrombotic occlusions. Further development for ischemic stroke therapy is justified.

Animals↗

Ultrasound wave propagation in tissue and scattering from microbubbles for echo particle image velocimetry technique.

Nonlinear wave propagation in tissue can be employed for tissue harmonic imaging, ultrasound surgery, and more effective tissue ablation for high intensity focused ultrasound (HIFU). Wave propagation in soft tissue and scattering from microbubbles (ultrasound contrast agents) are modeled to improve detectability, signal-to-noise ratio, and contrast harmonic imaging used for echo particle image velocimetry (Echo-PIV) technique. The wave motion in nonlinear material (tissue) is studied using KZK-type parabolic evolution equation. This model considers ultrasound beam diffraction, attenuation, and tissue nonlinearity. Time-domain numerical model is based on that originally developed by Lee and Hamilton [J. Acoust. Soc. Am 97:906-917 (1995)] for axi-symmetric acoustic field. The initial acoustic waveform emitted from the transducer is assumed to be a broadband wave modulated by Gaussian envelope. Scattering from microbubbles seeded in the blood stream is characterized. Hence, we compute the pressure field impinges the wall of a coated microbubble; the dynamics of oscillating microbubble can be modeled using Rayleigh-Plesset-type equation. Here, the continuity and the radial-momentum equation of encapsulated microbubbles are used to account for the lipid layer surrounding the microbubble. Numerical results show the effects of tissue and microbubble nonlinearities on the propagating pressure wave field. These nonlinearities have a strong influence on the waveform distortion and harmonic generation of the propagating and scattering waves. Results also show that microbubbles have stronger nonlinearity than tissue, and thus improves S/N ratio. These theoretical predictions of wave phenomena provide further understanding of biomedical imaging technique and provide better system design.

Computer Simulation↗

Preparation and evaluation of poly(L-lactide-co-glycolide) (PLGA) microbubbles as a contrast agent for myocardial contrast echocardiography.

A kind of absorbable PLGA microbubble-based contrast agent (PLGA microspheres with porous or hollow inner structure) was fabricated by an improved double emulsion-solvent evaporation method. The contrast efficiency was evaluated and proved both in vitro and in vivo. By adjusting the polymer concentration and volume of the inner aqueous phase during the fabrication of microbubbles, the inner structure of the microbubbles could be controlled. Both air-filled and perfluoropropane-filled microbubbles can opacify the left ventricle. However, when compared with air-filled microbubbles, perfluoropropane-filled microbubbles can produce significantly longer enhancement in left ventricle in the dog model due to the lower diffusivity and lower solubility of perfluoropropane in blood. A suspension of perfluoropropane-filled PLGA microbubbles (1.8 microm average microbubbles size, 2 x 10(8) microbubbles/mL concentration) has successfully and safely achieved myocardial opacification in closed-chest dogs. A perfusion defect was observed in both of the two dogs with acute myocardial infarction with Power Contrast Imaging (PCI) triggered technology. In the examination of contrast in both ventricular and myocardial opacification, the high mechanical index (MI) was found to have superior contrast sensitivity over the low MI for PLGA-based contrast agents.

Acoustics↗