Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETISM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Effects of paramagnetic ferrocenium cations on the magnetic properties of the anionic single-molecule magnet [Mn(12)O(12)(O(2)CC(6)F(5))(16)(H(2)O)(4)]-.

The preparation and physical characterization are reported for the single-molecule magnet salts [M(Cp')(2)](n)()[Mn(12)O(12)(O(2)CC(6)F(5))(16)(H(2)O)(4)] (M = Fe, n = 1, Cp' = C(5)Me(5) (2a), C(5)H(5) (2b); M = Co, n = 1, Cp' = C(5)Me(5) (2c), C(5)H(5) (2d); M = Fe, n = 2, Cp' = C(5)Me(5) (2e), C(5)H(5) (2f)) to investigate the effects of paramagnetic cations on the magnetization relaxation behavior of [Mn(12)]- anionic single-molecule magnets. Complex 2a.2H(2)O crystallizes in the orthorhombic space group Aba2, with cell dimensions at 173 K of a = 25.6292(2) A, b = 25.4201(3) A, c = 29.1915(2) A, and Z = 4. Complex 2c.2CH(2)Cl(2).C(6)H(14) crystallizes in the monoclinic space group P2(1)/c, with cell dimensions at 173 K of a = 17.8332(6) A, b = 26.2661(9) A, c = 36.0781(11) A, beta = 92.8907(3) degrees, and Z = 4. These two salts consist of either paramagnetic [Fe(C(5)Me(5))(2)]+ cations or diamagnetic [Co(C(5)Me(5))(2)]+ cations, and [Mn(12)O(12)(O(2)CC(6)F(5))(16)(H(2)O)(4)]- anions. The structures of the anions in the two salts are similar, consisting of a central Mn(4)O(4) cubane moiety, surrounded by a nonplanar ring of eight Mn atoms that are bridged by and connected to the cube via mu(3)-O(2)- ions. The oxidation states of four Mn sites out of eight outer Mn ions in complex 2a were assigned to be +2.75 from the valence bond sum analysis although the disordering of bridging carboxylates prevents more precise determination. On the other hand in complex 2c, one Mn site out of eight outer Mn ions was identified as a Mn(II) ion, accommodating the "extra" electron; this was deduced by a valence bond sum analysis. Thus, the anion in complex 2c has a Mn(II)(1)Mn(III)(7)Mn(IV)(4) oxidation state description. The Jahn-Teller axes of the Mn(III) ions in both anions are roughly aligned in one direction. All complexes studied exhibit a single out-of-phase ac magnetic susceptibility (chi"(M)) signal in the 4.6-4.8 K range for complexes 2a-2d and in the 2.8-2.9 K range for complexes 2e and 2f at 1 kHz ac frequency. The temperature of the chi"(M) peaks is frequency dependent, as expected for single-molecule magnets. From Arrhenius plots of the frequency dependence of the temperature of the chi"(M) maxima, the effective energy barriers U(eff) for changing spin from "up" to spin "down" were estimated to be 50-54 K for complexes 2a-2d and 27-28 K for complexes 2e and 2f. The least-squares fits of the reduced magnetization data indicate that both complexes 2a and 2d have ground states of S = (21)/(2). High-frequency EPR spectra were recorded for complex 2a at frequencies of 217, 327, and 434 GHz in the 4.5-30 K range. The observed transition fields were least-squares fit to give g = 1.91, D = -0.35 cm(-1), and B(4)(0) = -3.6 x 10(-7) cm(-1) for the S = (21)/(2) ground state. The effective energy barrier U(eff) is slightly lower than U estimated from D, which is consistent with the thermally assisted tunneling model. Magnetization hysteresis loops were observed for complexes 2a and 2c. Although 2a was oriented in a different manner as expected by strong magnetic field, both complexes show clear hysteresis loops with some steps on them, indicating that the effect of the magnetic cation on the magnetization relaxation of the anionic [Mn(12)]- complex is rather small. An 11% (57)Fe enriched complex 2b was studied by means of Mössbauer spectroscopy down to as low as 1.7 K. Slow paramagnetic relaxation broadening and magnetic hyperfine splitting were evident in the low-temperature spectra, indicating that the iron atoms feel a growing magnetic field owing to slow magnetization reversal in the [Mn(12)]- anions.

Journal Article↗

Magnetic orientation and the magnetic sense in arthropods.

The physical properties of the earth's magnetic field are summarized with the aim of emphasizing their significance as cues that can be exploited in orientational tasks. Past work has revealed magnetic orientation in vertebrates as well as invertebrates, including arthropods. The key finding to date has been that, as opposed to many vertebrates, the magnetic compass of arthropods responds to the polarity, rather than to the inclination of the earth's magnetic field. As in the case of vertebrates, the debate over how arthropods detect magnetic fields has yet to be resolved. Currently, evidence has been reported in support of a detection system based on magnetite crystals together with a variety of detection systems based on events occurring at the molecular level. Interactions between the magnetic and other compasses in orientation experiments suggest the existence of an area in the brain where spatial orientation information from magnetic and other stimuli converges. The slow advance of our knowledge on magnetic orientation in arthropods, as opposed to the much better understanding of magnetic orientation in vertebrates, arises from difficulties in identifying the appropriate behavioural contexts in which arthropods respond to magnetic fields in both laboratory and field situations. Arthropods thus present challenges not only in demonstrating magnetic orientation, but also in elucidating the sensory mechanisms involved in the perception of magnetic fields.

Animals↗

Safety study of the Cochlear Nucleus 24 device with internal magnet in the 1.5 Tesla magnetic resonance imaging scanner.

OBJECTIVES: To evaluate the effect of the 1.5 Tesla magnetic resonance imager (MRI) on the Cochlear Nucleus 24 Device without removing the internal magnet. To determine whether device fixation using a compression dressing could prevent internal magnet displacement in the MRI scanner and potentially obviate the need for surgical removal of the internal magnet. STUDY DESIGN: Prospective cadaveric study. METHODS: Four cadaver heads were implanted bilaterally with the Nucleus device with the internal magnet in place and placed into the 1.5 Tesla MRI scanner. The devices were then explanted after interaction with the MRI and evaluated for displacement of the internal magnet. Conditions tested include device fixation with a commercially available compression dressing and no fixation (worst-case scenario). Magnet strength was measured before and after each of the test conditions. RESULTS: Moderate to severe displacement of the magnet from the internal device occurred in 14 of 16 (87%) implants when no compression dressing was placed. Displacement occurred in 0 of 16 (0%) implants when the compression dressing was applied. No decrease in the strength of the implant magnet was found with the initial or subsequent MRI/implant interactions. CONCLUSIONS: Use of the 1.5 Tesla MRI on subjects with Cochlear Nucleus 24 implants did not result in any significant demagnetization of the internal magnet and did not cause displacement of the magnet when an external compression dressing was applied. Surgical removal of the internal magnet before scanning with the 1.5 Tesla MRI may not be necessary if a compression dressing is applied.

Cadaver↗

Single-chain magnet (NEt4)[Mn2(5-MeOsalen)2Fe(CN)6] Made of Mn(III)-Fe(III)-Mn(III) trinuclear single-molecule magnet with an S(T) = 9/2 spin ground state.

The cyano-bridged trinuclear compound, (NEt(4))[Mn(2)(salmen)(2)(MeOH)(2)Fe(CN)(6)] (1) (salmen(2)(-) = rac-N,N'-(1-methylethylene)bis(salicylideneiminate)), reported previously by Miyasaka et al. (ref 19d) has been reinvestigated using combined ac and dc susceptibility measurements. The strong frequency dependence of the ac susceptibility and the slow relaxation of the magnetization show that 1 behaves as a single-molecule magnet with an S(T) = (9)/(2) spin ground state. Its relaxation time (tau) follows an Arrhenius law with tau(0) = 2.5 x 10(-)(7) s and Delta(eff)/k(B) = 14 K. Moreover, below 0.3 K, tau saturates around 470 s, indicating that quantum tunneling of the magnetization becomes the dominant process of relaxation. (NEt(4))[Mn(2) (5-MeOsalen)(2)Fe(CN)(6)] (2) (5-MeOsalen(2)(-) = N,N'-ethylenebis(5-methoxysalicylideneiminate)) is a heterometallic one-dimensional assembly made of the trinuclear [Mn(III)(SB)-NC-Fe(III)-CN-Mn(III)(SB)] (SB is a salen-type Schiff-base ligand) motif similar to 1. Compound 2 has two types of bridges, a cyano bridge (-NC-) and a biphenolate bridge (-(O)(2)-), connecting Mn(III) and Fe(III) ions and the two Mn(III) ions, respectively. Both bridges mediate ferromagnetic interactions, as shown by modeling the magnetic susceptibility above 10 K with g(av) = 2.03, J(Mn)(-)(Fe)/k(B) = +6.5 K, and J'/k(B) = +0.07 K, where J' is the exchange coupling between the trimer units. The dc magnetic measurements of a single crystal using micro-SQUID and Hall-probe magnetometers revealed a uniaxial anisotropy (D(T)/k(B) = -0.94 K) with an easy axis lying along the chain direction. Frequency dependence of the ac susceptibility and time dependence of the dc magnetization have been performed to study the slow relaxation of the magnetization. A mean relaxation time has been found, and its temperature dependence has been studied. Above 1.4 K, both magnetic susceptibility and relaxation time are in agreement with the dynamics described in the 1960s by R. J. Glauber for one-dimensional systems with ferromagnetically coupled Ising spins (tau(0) = 3.7 x 10(-)(10) s and Delta(1)/k(B) = 31 K). As expected, at lower temperatures below 1.4 K, the relaxation process is dominated by the finite-size chain effects (tau'(0) = 3 x 10(-)(8) s and Delta(2)/k(B) = 25 K). The detailed analysis of this single-chain magnet behavior and its two regimes is consistent with magnetic parameters independently estimated (J'and D(T)) and allows the determination of the average chain length of 60 nm (or 44 trimer units). This work illustrates nicely a new strategy to design single-chain magnets by coupling ferromagnetically single-molecule magnets in one dimension.

Journal Article↗

Study of magnetic particles pulse-injected into an annular SPLITT-like channel inside a quadrupole magnetic field.

Advantages of the continuous magnetic flow sorting for biomedical applications over current, batch-wise magnetic separations include high throughput and a potential for scale-up operations. A continuous magnetic sorting process has been developed based on the quadrupole magnetic field centered on an annular flow channel. The performance of the sorter has been described using the conceptual framework of split-flow thin (SPLITT) fractionation, a derivative of field-flow fractionation (FFF). To eliminate the variability inherent in working with a heterogenous cell population, we developed a set of monodisperse magnetic microspheres of a characteristic magnetization, and a magnetophoretic mobility, similar to those of the cells labeled with a magnetic colloid. The theory of the magnetic sorting process has been tested by injecting a suspension of the magnetic beads into the carrier fluid flowing through the sorter and by comparing the theoretical and experimental recovery versus total flow-rate profiles. The position of the recovery maxima along the total flow-rate axis was a function of the average bead magnetophoretic mobility and the magnetic field intensity. The theory has correctly predicted the position of the peak maxima on the total flow-rate axis and the dependence on the bead mobility and the field intensity, but has not correctly predicted the peak heights. The differences between the calculated and the measured peak heights were a function of the total flow-rate through the system, indicating a fluid-mechanical origin of the deviations from the theory (such as expected of the lift force effects in the system). The well-controlled elution studies using the monodisperse magnetic beads, and the SPLITT theory, provided us with a firm basis for the future sorter evaluation using cell mixtures.

Magnetics↗

A hybrid, inverse approach to the design of magnetic resonance imaging magnets.

This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries.

Algorithms↗

Direct versus mediated through-space magnetic interactions: A first principles, bottom-up reinvestigation of the magnetism of the pyridyl-verdazyl:hydroquinone molecular co-crystal.

The mechanism of the magnetic interaction in the pyridyl-verdazyl radical:hydroquinone (pyvd:hq) molecular co-crystal is important as it has been suggested to originate by a unique "mediated through-space" magnetic interaction. This interaction was proposed to magnetically connect two nonadjacent pyridyl-verdazyl radicals within a pi stack, where adjacent radicals pile up in a head-over-tail orientation. The connection is made through a third radical sitting between the previous two mediated radicals. Given the relevance of this proposal, we decided to reinvestigate the magnetic properties of this co-crystal by using our recently proposed first-principles "bottom-up" procedure. Based on B3LYP/6-31+G(d) and CASSCF(6,6)/6-31+G(d) calculations (the results of which are identical to those provided by CASSCF(10,10)/6-31+G(d) calculations), we have computed the microscopic J(AB) values for all direct through-space magnetic interactions between nearby pyridyl-verdazyl radicals. The magnetic interactions give rise to two dominant values of similar strength: -56 and -54 cm(-1) at the B3LYP level, which are calculated as -38 and -31 cm(-1) at the CASSCF(6,6) and CAS(10,10) levels (all other interactions being smaller than |1| cm(-1)). The dominant interactions correspond to the direct through-space interaction between two adjacent radicals of a pi stack. The crystal also exhibits a radical-mediated through-space interaction of -0.31 cm(-1) between two nonadjacent radicals of a pi stack. The direct through-space magnetic interactions are two orders of magnitude larger than the mediated through-space interaction. Thus, first-principles calculations do not support a mediated through-space mechanism to explain the magnetism of the pyvd:hq co-crystal. The magnetic topology generated by the two dominant antiferromagnetic interactions in the pyvd:hq co-crystal consists of one-dimensional (1D) alternating chains (interacting very weakly along the b and c axes). By using this topology, the computed macroscopic magnetic susceptibility curve reproduces the experimental one properly. This first-principles bottom-up description of the magnetism in the pyvd:hq co-crystal differs in some fundamental aspects from that previously proposed in the literature.

Journal Article↗

Extremely low frequency magnetic fields in residences in Germany. Distribution of measurements, comparison of two methods for assessing exposure, and predictors for the occurrence of magnetic fields above background level.

We examined the results of 1,835 magnetic field measurements in German residences conducted between November 1997 and September 1999. The measurements were part of an epidemiological study on the relationship between magnetic fields and childhood leukemia. We performed a fixed-location measurement of the magnetic field at 50 Hz and 16 2/3 Hz (frequency of the German railway system) over 24 h in the child's bedroom in the residence of each study participant. In addition, we conducted a second 24 h-measurement in the living room at 50 Hz, and spot measurements while walking through all rooms of the respective dwelling. Median 50 Hz magnetic fields above 0.2 muT were found to be infrequent in Germany (only 1.4% of all residences). Fields produced by high-voltage power lines (123-420 kV) were lower than expected: the median magnetic field was above 0.2 muT in only 8 (32.0%) of 25 residences located 50 m or closer to a high-voltage power line indicating that power lines in Germany are usually run well below the maximum power load. We found that magnetic fields were correlated with the type of residence and higher magnetic fields were measured in apartment buildings. There was also some evidence for a positive correlation between magnetic fields and traffic density and an inverse association between magnetic fields and family net income. The 24 h-magnetic field measurements correlated well with the spot measurements (r>0.7). However, when dichotomized with a cut-off point of 0.2 muT, there was only a poor agreement between the two measurement methods. A loss of the strength of the association after categorization was also observed when comparing the arithmetic mean and median of the same 24 h-measurement. In summary, these analyses give a valuable overview of magnetic field distributions in German residences.

Child↗

Magnetic nanostructures as amplifiers of transverse fields in magnetic resonance.

We introduce the concept of amplifying the transverse magnetic fields produced and/or detected with inductive coils in magnetic resonance settings by using the reversible transverse susceptibility properties of magnetic nanostructures. First, we describe the theoretical formalism of magnetic flux amplification through the coil in the presence of a large perpendicular DC magnetic field (typical of magnetic resonance systems) achieved through the singularity in the reversible transverse susceptibility in anisotropic single domain magnetic nanoparticles. We experimentally demonstrate the concept of transverse magnetic flux amplification in an inductive coil system using oriented nanoparticles with uni-axial magnetic anisotropy. We also propose a composite ferromagnetic/anti-ferromagnetic core/shell nanostructure system with uni-directional magnetic anisotropy that, in principle, provides maximal transverse magnetic flux amplification.

Journal Article↗

Magnetic fluctuations with a zero mean field in a random fluid flow with a finite correlation time and a small magnetic diffusion.

Magnetic fluctuations with a zero mean field in a random flow with a finite correlation time and a small yet finite magnetic diffusion are studied. Equation for the second-order correlation function of a magnetic field is derived. This equation comprises spatial derivatives of high orders due to a nonlocal nature of magnetic field transport in a random velocity field with a finite correlation time. For a random Gaussian velocity field with a small correlation time the equation for the second-order correlation function of the magnetic field is a third-order partial differential equation. For this velocity field and a small magnetic diffusion with large magnetic Prandtl numbers the growth rate of the second moment of magnetic field is estimated. The finite correlation time of a turbulent velocity field causes an increase of the growth rate of magnetic fluctuations. It is demonstrated that the results obtained for the cases of a small yet finite magnetic diffusion and a zero magnetic diffusion are different.

Journal Article↗

High-resolution magnetic relaxation dispersion measurements of solute spin probes using a dual-magnet system.

The magnetic field dependence of the nuclear spin-lattice relaxation rate provides a detailed report of the spectral density functions that characterize the intra- and intermolecular fluctuations that drive magnetic relaxation. We have addressed the difficult sensitivity and resolution problems associated with low magnetic field strengths by using two magnets in close proximity and shielded from each other. The sample is stored in the high magnetic field, pneumatically driven to the variable satellite field, then returned to the high field for detection at high resolution. A magnetic shield effectively decouples the two magnets so that varying the satellite field strength has minimal effect on the field strength and shim of the high field magnet. The disadvantage of the sample-shuttle magnet-pair system is the restriction imposed on the relaxation times by the finite shuttle times. Experiments not described here have shown this rate maximum to be about 20 s(-1) for most practical solutions. However, we demonstrate here that the sensitivity gains over switched-current magnet systems permit characterization of solute inter- and intramolecular dynamics over the time scale range from tens of microseconds to less than a picosecond. This range permits investigation of a number of crucial chemical dynamics questions, while high sensitivity permits examination of a variety of solute spins. Representative data are presented for (1)H, (111)Cd, and (7)Li.

Cadmium↗

[Field perturbations by magnetic dipoles as a model for magnetically labelled cells in MRI].

UNLABELLED: Due to the creation of intense local magnetic fields, iron oxide nanoparticles are used as a contrast agent to produce signal loss in Magnetic Resonance Imaging (MRI) in regions where labelled cells have migrated. OBJECTIVE: To study effects of the intracellular distribution of magnetic moments on the extracellular magnetic field by means of numerical simulations. METHODS: Various geometries of intracellular particle distributions were scrutinized and the extracellular field distortions were computed. The total magnetic moment of a labelled cell was assigned to various magnetic subcompartments. The implications on the intravoxel frequency distribution and the static MR signal decay were assessed. RESULTS: The extracellular field perturbation was affected by the intracellular particle distribution only in close proximity to the labelled cell. With increasing distance from the labelled cell, the effects of the intracellular particle distribution were less pronounced. The intravoxel frequency distribution induced by a single labelled cell was non-lorentzian. CONCLUSION: The magnetic fields created by an iron loaded cell are sensitive to the intracellular distribution of nanoparticles only in close proximity to the cell. Far from the cell the field perturbation cannot be distinguished from the magnetic dipole field produced by a magnetic sphere with the same total magnetic moment.

Humans↗

[A functional orthodontic magnetic appliance (FOMA) after Vardimon. 1. A three-dimensional analysis of the force system of the attractive magnets].

The functional magnetic system (FMS) is a removable functional appliance which induces mandibular advance by means of mandibular and maxillary magnets in an attracting configuration. The maxillary and mandibular plates are each equipped with 2 cylindrically shaped cobalt-samarium magnets, 4 mm in diameter and 3 mm in height, which are welded into stainless steel housings. The force system of this magnetic configuration was analyzed using the orthodontic measurement and simulation system (OMSS). OMSS simulated the mandibular jaw movements by separating the installed magnets vertically, corresponding to a mouth opening of X = -10 mm, transversally (right excursion, +/left excursion, -) at Y = +/- 10 mm and sagittally (anterior displacement, +/posterior displacement, -) at Z = +/- 10 mm. The resulting 2D and 3D force/displacement diagrams elucidate the outstanding centripetal-spatial orientation characteristics of the functional magnetic appliance in reference to the full overlap brought about by the attraction of the mandibular magnet by the maxillary magnet. The maximum centripetal forces reached a value of approximately FY, max = 0.65 N for the vertical attracting force at full overlap of the mandibular and maxillary magnets (X = 0.55 mm, Y = Z = 0 mm), a value of FY, max = 0.65 N for the medial shearing force at a partial transversal overlap Z = 0, Y = +/- 2 mm and Y = +/- 6 mm), and for the sagittal shearing force a value of FZ, max = 1.2 N at a partial sagittal overlap of the magnets (Y = 0 mm, Z = +/- 2 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

Cobalt↗

Magnetic strength and corrosion of rare earth magnets.

INTRODUCTION: Rare earth magnets have been used in orthodontics, but their corrosion tendency in the oral cavity limits long-term clinical application. The aim of this project was to evaluate several; magnet coatings and their effects on magnetic flux density. METHODS: A total of 60 neodymium-iron-boron magnets divided into 6 equal groups--polytetrafluoroethylene-coated (PTFE), parylene-coated, and noncoated--were subjected to 4 weeks of aging in saline solution, ball milling, and corrosion testing. RESULTS: A significant decrease in magnet flux density was recorded after applying a protective layer of parylene, whereas a slight decrease was found after applying a protective layer of PTFE. After 4 weeks of aging, the coated magnets were superior to the noncoated magnets in retaining magnetism. The corrosion-behavior test showed no significant difference between the 2 types of coated magnets, and considerable amounts of iron-leached ions were seen in all groups. CONCLUSIONS: Throughout the processes of coating, soaking, ball milling, and corrosion testing, PTFE was a better coating material than parylene for preserving magnet flux density. However, corrosion testing showed significant metal leaching in all groups.

Boron↗

Magnetic drug targeting--biodistribution of the magnetic carrier and the chemotherapeutic agent mitoxantrone after locoregional cancer treatment.

Magnetic Drug Targeting means the specific delivery of chemotherapeutic agents to their desired targets, e.g. tumors, by using magnetic nanoparticles (ferrofluids) bound to these agents and an external magnetic field which is focused on the tumor. This type of target directed drug injection attempts to concentrate a pharmacologic agent by enhancing its efficacy while simultaneously minimizing deleterious side effects. In previous studies, we have been able to demonstrate the efficacy of this type of localized intraarterial chemotherapy in VX2 squamous cell carcinoma among rabbits [Alexiou, C., Arnold, W., Klein, R.J., Parak, F.G., Hulin, P., Bergemann, C., Erhardt, W., Wagenpfeil, S. and Lübbe, A.S. "Locoregional cancer treatment with Magnetic Drug Targeting", Cancer Res. 60 (2000) 6641-6648]. In the present investigation, we have studied the biodistribution of ferrofluids and chemotherapeutic agent by measuring the amount in the tumor, peritumoral area, various organs and body fluids (e.g. blood and urine), with and without Magnetic Drug Targeting. We compared results to that of administering a chemotherapeutic agent soley. An external magnetic field was directed toward the tumor for 60 min. Biodistribution of ferrofluids in the tumor was investigated using histological cross sections and measured semi-quantitatively using 123I-labeled nanoparticles and quantitatively by the use of radioactive 59Fe-ferrofluids. Mitoxantrone was quantitatively measured using HPLC-analysis. The strength of the external magnetic field was 0.6 Tesla (permanent magnet) in the 123iodine study and 1.7 Tesla (electromagnet) in the 59Fe-study and HPLC-analysis. The concentration of the ferrofluids (FFs) in the tumor region i.e. the tumor tissue and the surrounding area, which was under the influence of an external magnetic field, was found to be much higher than in the absence of one. In contrast to systemic chemotherapy, a much higher concentration of mitoxantrone in the tumor and the peritumoral area (region surrounding the tumor < or = 1 cm), by using only 50% and 20% of the normal dose was seen. Thus, the higher concentration of mitoxantrone could explain the therapeutic efficacy of Magnetic Drug Targeting in treatment of VX2 squamous cell carcinoma in rabbits in our previous studies with the advantage of no adverse clinical side effects.

Animals↗

[Establishment of two-dimensional magnetic field finite element analysis model of cup-yoke-type magnetic attachment].

OBJECTIVE: The purpose of this study was to establish two-dimensional magnetic field finite element analysis model of cup-yoke-type magnetic attachment for optmizing the design of magnetic attachments. METHODS: Because the magnetic field of cup-yoke-type magnetic attachment is stable axial-symmetrical, the authors only analyzed two-dimensional magnetic field of 1/2 section. The Maxwell stress between magnet and keeper was integral analyzed using the finite element method, and the attractive force between magnetic attachments was obtained. RESULTS: Compared the value of calculated attractive force with that of examined, the authors found that the procedure veritably reflected influencing trend of variable factors on attractive force, and the value of former one was 10% less than the later one. CONCLUSION: This procedure can be used in magnetic field calculation of cup-yoke-type magnetic attachments.

Computer Simulation↗

[MnIII2 (5-Rsaltmen)2NiII(pao)2(L)]2+: an S(T)=3 building block for a single-chain magnet that behaves as a single-molecule magnet.

Mn(III)-Ni(II)-Mn(III) linear-type trinuclear complexes bridged by oximate groups were selectively synthesized by the assembly reaction of [Mn2(5-Rsaltmen)2(H2O)2](ClO4)2 (5-Rsaltmen2-=N,N'-(1,1,2,2-tetramethylethylene) bis(5-R-salicylideneiminate); R=Cl, Br) with [Ni(pao)2(phen)] (pao-=pyridine-2-aldoximate; phen=1,10-phenanthroline) in methanol/water: [Mn2(5-Rsaltmen)2Ni(pao)2(phen)](ClO4)2 (R=Cl, 1; R=Br, 2). Structural analysis revealed that the [Mn(III)-ON-Ni(II)-NO-Mn(III)] skeleton of these trimers is in every respect similar to the repeating unit found in the previously reported series of 1D materials [Mn2(saltmen)2Ni(pao)2(L1)2](A)(2) (L(1)=pyridine, 4-picoline, 4-tert-butylpyridine, N-methylimidazole; A=ClO4-, BF4-, PF6-, ReO4-). Recently, these 1D compounds have attracted a great deal of attention for their magnetic properties, since they exhibit slow relaxation of the magnetization (also called single-chain magnet (SCM) behavior). This unique magnetic behavior was explained in the framework of Glauber's theory, generalized for chains of ferromagnetically coupled anisotropic spins. Thus, in these 1D compounds, the [Mn(III)-ON-Ni(II)-NO-Mn(III)] unit was considered as an S(T)=3 anisotropic spin. Direct-current magnetic measurements on 1 and 2 confirm their S(T)=3 ground state and strong uniaxial anisotropy (D/k(B) approximately -2.4 K), in excellent agreement with the magnetic characteristic deduced in the study on the SCM series. The ac magnetic susceptibility of these trimers is strongly frequency-dependent and characteristic of single-molecule magnet (SMM) behavior. The relaxation time tau shows a thermally activated (Arrhenius) behavior with tau0 approximately 1x10(-7) s and Delta(eff)/k(B) approximately 18 K. The effective energy barrier for reversal of the magnetization Delta(eff) is consistent with the theoretical value (21 K) estimated from |D| S2T. The present results reinforce consistently the interpretation of the SCM behavior observed in the [Mn2(saltmen)2Ni(pao)2(L1)2](A)2 series and opens new perspectives to design single-chain magnets.

Journal Article↗

Transport coefficients and orientational distributions of spheroidal particles with magnetic moment normal to the particle axis (Analysis for an applied magnetic field normal to the shear plane).

We have investigated the influence of the magnetic field strength, shear rate, and rotational Brownian motion on transport coefficients such as viscosity and diffusion coefficient, and also on the orientational distributions of rodlike particles of a dilute colloidal dispersion. The rodlike particle is modeled as a magnetic spheroidal particle which has a magnetic moment normal to the particle axis; such a particle may typically be a hematite particle. In the present study, an external magnetic field is applied in the direction normal to the shear plane of a simple shear flow. The basic equation of the orientational distribution function has been derived from the balance of torques and solved numerically. The results obtained here are summarized as follows. Although the orientational distribution function shows a sharp peak in the shear flow direction for a very strong magnetic field, such a peak is not restricted to the field direction alone, but continues in every direction of the shear plane. This is due to the characteristic particle motion that the particle can rotate around the axis of the magnetic moment in the shear plane, although the magnetic moment nearly points to the magnetic field direction. This particle motion in the shear plane causes negative values of the viscosity due to the magnetic field. The viscosity decreases, attains a minimum value, and then converges to zero as the field strength increases. Additionally, the diffusion coefficient is significantly influenced by such characteristic particle motion in the shear plane for a strong magnetic field.

Journal Article↗