Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid-Liquid Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Determination of terbinafine in tissues.

Terbinafine and N-demethyl terbinafine concentrations were determined simultaneously in rat tissues by a high-performance liquid chromatography method. This method involved the homogenization of tissues (except for skin) followed by a liquid-liquid extraction. Skin samples were dissolved in sodium hydroxide prior to extraction. Terbinafine and its N-demethylated metabolite were assayed using a C(18) reversed-phase column with a mobile phase of acetonitrile and water (40:60) containing ortho phosphoric acid (0.02 M) and triethylamine (0.01 M), and UV detection (at 224 nm). The standard curve for the assay (constructed using clotrimazole as internal standard) was linear over the concentration range 100-3000 ng/g in skin and 10-600 ng/g in all other tissues. The inter- and intra-day precision for both terbinafine and metabolite was between 0.2% and 16%. The limit of quantification was 10 ng/g in all tissues and 100 ng/g in skin. This assay was found to be reliable and reproducible for the determination of terbinafine and N-demethyl terbinafine concentration in all rat tissues and has been used for tissue distribution studies.

Adipose Tissue↗

Quantitative determination of melatonin in human plasma and cerebrospinal fluid with high-performance liquid chromatography and fluorescence detection.

A validated new and precise reversed-phase high-performance liquid chromatographic method for the determination of melatonin in human plasma and cerebrospinal fluid, with 5-fluorotryptamine as internal standard, is described. Liquid-liquid extraction with dichloromethane was performed under alkaline conditions. After evaporation of the organic solvent, the extract was dissolved in eluent and chromatographed on a base-deactivated octadecyl column, using an eluent composed of 650 mL potassium dihydrogenphosphate solution (0.07 mol/L water), adjusted to a pH of 3.0 with a 43% phosphoric acid solution, mixed with 350 mL methanol. Fluorescence detection at an excitation wavelength of 224 nm and an emission wavelength of 348 nm was used for quantitation. Melatonin and 5-fluorotryptamine chromatographed with retention times of 5.3 and 9. 3 min, respectively. Mean recoveries of 96% (n = 10) and 95% (n = 5) were found for melatonin in plasma and cerebrospinal fluid respectively. 5-Fluorotryptamine was found to have a mean recovery of 90% (n = 10) and 82% (n = 5) in plasma and cerebrospinal fluid, respectively. The repeatability coefficients of variation for both melatonin and 5-fluorotryptamine in plasma were 4-5% [five different samples (r = 5) on two consecutive days (n = 2)], with reproducibility coefficients of 1.6-7% (n = 2, r = 5) and 0.9-4% (n = 2, r = 5) for melatonin and internal standard, respectively. In cerebrospinal fluid the repeatability coefficient of variation of the extraction procedure was 5% (n = 1, r = 5) for melatonin and 7% (n = 1, r = 5) for 5-fluorotryptamine. The correlation coefficients of the calibration curves were 0.9998 (n = 2) in plasma at a concentration range of 0.108-25.9 ng/mL and 0.9994 (n = 2) at a concentration range of 0.108-25.9 ng/mL in cerebrospinal fluid. The limit of detection was determined at 8 pg/mL which enables to measure melatonin concentrations at physiological concentrations reached during daytime.

Adult↗

A new sensitive determination method of estradiol in plasma using peroxyoxalate ester chemiluminescence combined with an HPLC system.

A new sensitive determination method of estradiol in a plasma sample using peroxyoxalate ester chemiluminescence was developed. Estradiol, which was extracted by liquid-liquid extraction using ethyl acetate from plasma, was derivatized with dansyl-chloride (DNS-Cl) and separated by reverse-phase HPLC. The performance of four oxalates, bis(trichlorophenyl)oxalate (TCPO), bis(2,4-dinitrophenyl)oxalate (DNPO), bis(pentafluorophenyl)oxalate (PFPO), and bis[4-nitro-2-(3,6, 9-trioxadecyloxycarbonyl)phenyl] oxalate (TDPO), were evaluated using the static system, and DNPO was found to have the most sensitive and stable chemiluminescence at a H(2)O(2) concentration of 30 mM. HPLC-chemiluminescence system using DNPO for the determination of estradiol was established. The detection limit of dansylated-estradiol (DNS-E2) was 15 fmol (4 pg) in the standard solution and 44 fmol (12 pg) in the rat plasma sample at S/N = 3.

Animals↗

High-throughput quantitative bioanalysis by LC/MS/MS.

This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.

Acetonitriles↗

Development and application of a chiral high performance liquid chromatography assay for pharmacokinetic studies of methadone.

Methadone enantiomers and EDDP, the main metabolite of methadone, were separated (R(s) = 2.0 for methadone enantiomers) following liquid-liquid extraction from human serum and urine followed by reverse-phase high-performance liquid chromatography on a derivatized beta-cyclodextrin column and quantified at therapeutic concentrations with ultraviolet detection. Detector response was linear (r(2) > 0.98) to 1,000 and 2,500 ng x mL(-1) for methadone enantiomers and EDDP, respectively. The limit of quantification from a 1-mL biological sample was 2.5 and 5 ng x mL(-1) for methadone enantiomers and EDDP, respectively. Interday variation was <13% and intraday variation was <8% for the analytes of interest. The assay was applied to plasma protein and erythrocyte binding studies and a 96-h pharmacokinetic study in two healthy female volunteers following oral dosing with rac-methadone. The binding of methadone to plasma proteins was enantioselective with the active (-)-(R) enantiomer having the highest free fraction (mean +/- SD: 21.2+/-7.6% vs. 13.3+/-6.2% for (+)-(S)-methadone, n = 8). Binding of methadone to erythrocytes was not apparently enantioselective (38.6+/-1.3% and 38.1+/-1.4% bound for (-)-(R)- and (+)-(S)-methadone, respectively). The pharmacokinetic study revealed enantioselective disposition of methadone in one volunteer but not in the other. EDDP was observed in urine but was only in small or undetectable concentrations in serum. The method is applicable to in vitro and pharmacokinetic studies of rac-methadone disposition in humans.

Administration, Oral↗

Enantiomeric determination of praziquantel and its main metabolite trans-4-hydroxypraziquantel in human plasma by cyclodextrin-modified micellar electrokinetic chromatography.

A capillary electrophoresis method for the simultaneous quantitation of praziquantel and its main metabolite trans-4-hydroxypraziquantel enantiomers in human plasma was developed and validated using cyclodextrin-modified micellar electrokinetic chromatography. Sample clean-up involved a single-step liquid-liquid extraction of plasma with toluene after the addition of NaCl. The complete enantioselective analysis was obtained in less than 7 min using 2% w/v sulfated beta-cyclodextrin as chiral selector and 20 mmol/L sodium deoxycholate as surfactant, in 20 mmol/L sodium borate buffer, pH 10. A 50 microm x 42 cm uncoated fused-silica capillary was used for the analysis, performed at a voltage of 18 kV and at 20 degrees C. The calibration curves were linear over the 125-625 ng/mL concentration range. The mean recoveries for praziquantel and trans-4-hydroxypraziquantel were up to 96 and 71%, respectively, with good precision. All four enantiomers were quantified at two concentration levels (200 and 600 ng/mL) with precision and accuracy below 15%. The quantitation limit was 50 ng/mL for (-)-(R)- and (+)-(S)-praziquantel and 62.5 ng/mL for (-)-(R)- and (+)-(S)-trans-4-hydroxypraziquantel, using 1 mL of human plasma.

Chromatography↗

Simultaneous determination of disopyramide and mono-N-dealkyldisopyramide enantiomers in human plasma by capillary electrophoresis.

In this paper, a rapid method for the enantioselective analysis of the antiarrhythmic drug disopyramide and its main metabolite mono-N-dealkyldisopyramide in human plasma by capillary electrophoresis employing the cyclodextrin-modified electrokinetic chromatography mode is described. Sample clean-up was carried out by alkalinization with sodium hydroxide followed by liquid-liquid extraction with toluene. The complete enantioselective analysis was performed within less than 5 min using 20 mmol/L sodium acetate buffer, pH 5.0, containing 0.2% w/v sulfated beta-cyclodextrin as chiral selector. A 40 cm uncoated fused-silica capillary was used for the analysis, performed at a voltage of 15 kV and at 20 degrees C. The calibration curves were linear over the concentration range of 62.5-1850 ng/mL and 125-1850 ng/mL for each enantiomer of disopyramide and mono-N-dealkyldisopyramide. The mean recoveries for disopyramide and mono-N-dealkyldisopyramide enantiomers were up to 87 and 69%, respectively. All four enantiomers studied could be quantified at three different concentrations (200, 400 and 600 ng/mL) with coefficient of variation and % relative error not higher than 15%. The quantitation limit was 62.5 ng/mL for (+)-(S)-and (-)-(R)-disopyramide and (-)-(R)-mono-N-dealkyldisopyramide and 125 ng/mL for (+)-(S)-mono-N-dealkyldisopyramide, using 1 mL of human plasma.

Disopyramide↗

Head-column field-amplified sample stacking in capillary electrophoresis for the determination of cimetidine, famotidine, nizatidine, and ranitidine-HCl in plasma.

In this study, low concentrations of histamine2-receptor (H2-)antagonists were effected across a water plug, with separation taking place in a binary buffer comprising ethylene glycol and NaH2PO4 (pH 5.0), and detection at 214 nm. Liquid-liquid extraction with ethyl acetate- isopropanol is shown to provide extracts that are sufficiently clean. The calibration curves were linear over a concentration range of 0.1-2.00 microg/mL cimetidine, 0.2-5.0 microg/mL ranitidine-HCl, 0.3-5.0 microg/mL nizatidine, and 0.1-3.0 microg/mL famotidine. Mean recoveries were > 82%, while the intra- and interday relative standard deviations (RSDs) and relative errors (REs) were all < 13%. The method is sensitive with a detection limit of 3 ng/mL cimetidine, 30 ng/mL ranitidine HCl, 50 ng/mL nizatidine and 10 ng/mL famotidine (S/N = 3, electric-driven injection 90 s). This newly developed capillary electrophoresis (CE) method was applied for the determination of analytes extracted from plasma taken from a volunteer dosing a cimetidine, ranitidine, and nizatidine tablet simultaneously. These three H2-antagonists can be detected in real samples by this method, excluding the low dosing of famotidine tablet.

Buffers↗

Enantioselective analysis of albendazole sulfoxide in cerebrospinal fluid by capillary electrophoresis.

Albendazole (ABZ) is a benzimidazole anthelmintic drug used in the treatment of neurocysticercosis. After oral administration, ABZ is rapidly oxidized to albendazole sulfoxide (ABZSO), which has an asymmetric sulfur center, and later to albendazole sulfone (ABZSO2). ABZSO is the active metabolite responsible for the therapeutic effect of the drug. Previous studies have demonstrated pharmacokinetic differences between the two enantiomers, with the predominance of (+)-ABZSO in human biological fluids. This article describes for the first time the enantioselective analysis of ABZSO in cerebrospinal fluid (CSF) using capillary electrophoresis. The samples were prepared by liquid-liquid extraction using chloroform:isopropanol (8:2 v/v). The resolution of ABZSO enantiomers was obtained with a fused-silica capillary (60 cm x 75 microm ID) using 20 mmol/L Tris, pH 7.0, with 3.0% w/w sulfated beta-cyclodextrin as running buffer. The coefficient of variations and % relative error obtained for both within-day and between-days assays were lower than 15%. The method was linear over the concentration range of 100 to 2,500 ng/mL for each enantiomer, indicating that it is suitable for the analysis of ABZSO enantiomers in CSF from patients medicated with ABZ.

2-Propanol↗

Investigation of capillary electrophoresis-laser induced fluorescence as a tool in the characterization of sewage effluent for fluorescent acids: determination of salicylic acid.

The investigation of emerging contaminant issues is a proactive effort in environmental analysis. As a part of this effort, sewage effluent is of current analytical interest because of the presence of pharmaceuticals and their metabolites and personal care products. The environmental impact of these components is still under investigation but their constant perfusion into receiving waters and their potential effect on biota is of concern. This paper examines a tool for the characterization of sewage effluent using capillary electrophoresis-laser induced fluorescence (CE-LIF) with a frequency-doubled laser operated in the ultraviolet (UV). Fluorescent acidic analytes are targeted because they present special problems for techniques such as gas chromatography-mass spectrometry (GC-MS) but are readily accessible to CE-LIF. As an example of the application of this tool, salicylic acid is determined near the 100 ng/L (7 x 10(-10) M) level in sewage effluent. Salicylic acid is a metabolite of various analgesics. Relatively stable in the environment, it is a common contaminant of municipal sewage systems. Salicylic acid was recovered from freshly collected samples of the effluent by liquid-liquid extraction. Confirmation of identity was by electron ionization GC-MS after conversion of the salicylic acid to the methyl ester by means of trimethylsilyldiazomethane. CE-LIF in the UV has revealed more than 50 individual peaks in the extract and a background response that suggests a large and indeterminate number of additional compounds are present. These data together with complementary techniques provide information on the complexity and components in these effluent streams.

Carboxylic Acids↗

Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography.

This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.

Chromatography, Micellar Electrokinetic Capillary↗

Determination of residues of enrofloxacin and its metabolite ciprofloxacin in chicken muscle by capillary electrophoresis using laser-induced fluorescence detection.

A method for the residue analysis of the veterinary antimicrobial agent enrofloxacin and its active desethyl metabolite ciprofloxacin in chicken muscle tissue has been developed and validated. The detection of the analytes was performed by laser-induced fluorescence (LIF) detection using a HeCd laser (lambda(ex) = 325 nm) providing an enhancement in sensitivity and selectivity compared to conventional UV detection. The assay has been validated with satisfying results. The limits of quantification for enrofloxacin and ciprofloxacin were 5 microg/kg and 20 microg/kg, respectively, with a fivefold preconcentration yielded by a sample clean-up with a simple liquid-liquid extraction procedure. Calibration graphs were linear from 5 to 1000 microg/kg for enrofloxacin and from 20 to 1000 microg/kg for ciprofloxacin. The assay allows the detection of contaminated muscle samples at the required maximum residue limit of the European Union, which is 100 microg/kg for the sum of enrofloxacin and ciprofloxacin.

Animals↗

Extraction of electrolytes from aqueous solutions and their spectrophotometric determination by use of acid-base chromoionophores in lipophylic solvents.

The formation of non-absorbing complexes in an organic phase has been exploited for the spectrophotometric determination of ionic analytes in aqueous solutions. The method is based on liquid-liquid extraction of aqueous solution with lipophylic organic phases containing an acid-base chromoionophore, a neutral lypophilic ligand (neutral carrier) selective to the analyte and a cationic (or anionic) exchanger. The method avoids all difficulties of the preparation of the very thin membranes used in optodes, so that it can advantageously be used for the study of the role physical-chemical parameters of the system in order to optimize them and to prepare, if necessary, an optimized optode. Two lipophylic derivatives of Nile Blue and 4',5-dibromofluorescein have been synthesized, in order to ensure their permanence within organic phase. Two different neutral carriers previously characterized by us as ionophores for liquid-membrane Ion Selective Electrodes have been employed. Three different ionic exchangers have been tested. Furthermore, a model allowing the interpolation of experimental data and the determination of the thermodynamic constant of the ionic-exchange equilibrium has been developed and applied.

Electrolytes↗

Aroma composition of red wines by different extraction methods and Gas Chromatography-SIM/MASS spectrometry analysis.

One hundred and one volatile compounds, reported in literature as powerful odorants of wine, were quantified by Gas Chromatography-Selective Ion Monitoring/Mass Spectrometry (GC-SIM/MS) in Primitivo, Aglianico, Merlot and Cabernet Sauvignon red wines. Wine samples were extracted by 3 different extraction methods: 1) separation of the alcoholic fraction from the aqueous phase by salting-out and subsequent extraction by liquid-liquid micro-extraction with 1,1,2-trichlorotrifluoroethane (Freon 113); 2) extraction by liquid-liquid micro-extraction with dichloromethane; 3) solid phase extraction (SPE cartridge: 800 mg of LiChrolut EN resin) with pentane-dichloromethane (20:1) and dichloromethane. The selection of the ion fragments used for quantification was directly performed on a red wine sample. For each compound the area of the corresponding peak was normalized respect to the peak of the internal standard and then interpolated in a calibration curve obtained analysing a model wine solution (water, ethanol, tartaric acid and known amounts of analytes and of internal standard). The methods showed a good linearity: r2>0.990, except for farnesol (isomer a and c), octanal, decanal, furaneol and phenylacetic acid with 0.966 < or = r2 < or = 0.990. The 7 most powerful odorants were: beta-damascenone, acetaldehyde, maltol, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, 3-methylbutanoic acid and acetal; 7 other slightly less important were: ethyl hexanoate, ethyl acetate, 1-octen-3-ol, butanoic acid, rose oxide, furaneol and sotolon. The Aglianico wines were characterised by the major fermentation compounds (esters, fatty acids and 2-phenylethanol), beta-damascenone, beta-ionone and linalool. The Primitivo wines were characterized by furaneol, methoxypyrazine, gamma-nonalactone and acetaldehyde, while Cabernet Sauvignon and Merlot wines principally by cask derivates (vanillin, (Z) 3-methyl-gamma-octalactone [(Z) wiskylactone], maltol and eugenol), some aldehydes and 3-isopropyl-2-methoxypyrazine.

Gas Chromatography-Mass Spectrometry↗

Determination of furaneol (4-hydroxy-2,5-dimethyl-3(2H)-furanone) in some wines from Italian native grapes by Gas-Chromatography-SIM/MASS spectrometry.

Gas Chromatography-Mass Spectrometry (GC-MS) analysis by Selective Ion Monitoring (SIM) was applied to quantify 4-Hydroxy-2,5-dimethyl-3(2H)-furanone (HDMF) in both red and white wines obtained from some Italian cultivar of Vitis vinifera. Wines were extracted by liquid-liquid extraction performed with 1,1,2-trichlorotrifluoroethane (Freon 113). The ion m/z 128 was used for quantification while the ion m/z 129 as qualifier. Precision, linearity and accuracy of the method resulted satisfactory. Results showed a significant variation in the concentration of furaneol in wine with grape variety. Generally, HDMF concentrations in white wines were lower than in red wines. Among white wines, Chardonnay resulted characterized by the highest concentration of HDMF. Among red wines the highest concentrations of HDMF were detected in Primitivo and Refosco varieties.

Furans↗

Determination of polycyclic aromatic hydrocarbons (PAHs) and total fats in human milk.

A sensitive and reliable analytical method was developed for the simultaneous extraction of PAHs and total fats and their determination in the human milk. The method involved a liquid-liquid extraction of PAHs and fats, followed by the gravimetric determination of the latter. PAHs were separated from lipids by size exclusion chromatography eluting with methylene chloride and analysed by gaschromatography coupled with mass spectrometry (GC/MS). The recovery of analytes was in the range of 42-101% and agreed well with their boiling temperatures (R2=0.779). Precision of the method was found between 7.6 and 19%. Quantification and detection limits for individual PAHs ranged from 0.011 to 0.032 and from 0.006 to 0.022 microg/Kg milk (wet weight), respectively. Quantification limit for the total fat determination was 0.26 g/Kg milk (wet weight). This procedure, applied to milk samples of ten healthy, non-smoking, Italian primiparae, living in rural or low-traffic zones, allowed for the identification and quantitative determination of naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo(a)anthracene, benzo(b)fluoranthene and benzo(k)fluoranthene in the mean concentration range 0.114-6.95 microg/Kg milk (wet weight). The most volatile compounds, which were not investigated elsewhere, were found at much higher concentrations than those observed for the others. No relation was found between PAH and total fat concentrations.

Adult↗

Hydrogen peroxide synthesis: an outlook beyond the anthraquinone process.

Hydrogen peroxide (H2O2) is widely used in almost all industrial areas, particularly in the chemical industry and environmental protection. The only degradation product of its use is water, and thus it has played a large role in environmentally friendly methods in the chemical industry. Hydrogen peroxide is produced on an industrial scale by the anthraquinone oxidation (AO) process. However, this process can hardly be considered a green method. It involves the sequential hydrogenation and oxidation of an alkylanthraquinone precursor dissolved in a mixture of organic solvents followed by liquid-liquid extraction to recover H2O2. The AO process is a multistep method that requires significant energy input and generates waste, which has a negative effect on its sustainability and production costs. The transport, storage, and handling of bulk H2O2 involve hazards and escalating expenses. Thus, novel, cleaner methods for the production of H2O2 are being explored. The direct synthesis of H2O2 from O2 and H2 using a variety of catalysts, and the factors influencing the formation and decomposition of H2O2 are examined in detail in this Review.

Journal Article↗