Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Liquid-phase microextraction and capillary electrophoresis of citalopram, an antidepressant drug.

A newly developed disposable device for liquid-phase microextraction (LPME) was evaluated for the capillary electrophoresis (CE) of the antidepressant drug citalopram (CIT) and its main metabolite N-desmethylcitalopram (DCIT) in human plasma. CIT and DCIT were extracted from 1 ml plasma samples through hexyl ether immobilised in the pores of a porous polypropylene hollow fibre and into 25 microl of 20 mM phosphate buffer (pH 2.75) present inside the hollow fibre (acceptor phase). Prior to extraction, the samples were made strongly alkaline in order to promote LPME of the basic drugs. Owing to the high ratio between the volumes of sample and acceptor phase, and owing to high partition coefficients, CIT and DCIT were enriched by a factor of 25 to 30. In addition, sample clean-up occurred during LPME since salts, proteins and the majority of endogenic substances were unable to penetrate the hexyl ether layer. Since the extracts were aqueous, they were injected directly into the CE instrument. Limits of quantification (S/N= 10) for CIT and DCIT in plasma were 16.5 ng/ml and 18 ng/ml respectively, while the limits of detection (S/N=3) were 5 ng/ml and 5.5 ng/ml respectively. This enabled CIT (and DCIT) to be analysed within the therapeutic range by LPME-CE and detection limits were comparable with previously reported HPLC methods.

Antidepressive Agents, Second-Generation↗

Application of dynamic liquid-phase microextraction to the analysis of chlorobenzenes in water by using a conventional microsyringe.

A dynamic liquid-phase microextraction technique combined with gas chromatography/mass spectrometry (GC/MS) is described for the extraction of 10 chlorobenzenes from water samples into 1 microL of organic solvent by using a conventional microsyringe. The effects of extraction solvent, plunger movement pattern, sampling volume, number of samplings, and salt concentration on the extraction performance were investigated. Good repeatabilities of extraction were obtained, with the RSD values below 5.3% except for hexachlorobenzene (9.3%). By using a sampling volume of 6 microL and 15 samplings, detection limits were found to be between 0.02 and 0.05 microgram/L under GC/MS-selective ion monitoring mode.

Chlorobenzenes↗

Ion-pair mediated transport of angiotensin, neurotensin, and their metabolites in liquid phase microextraction under acidic conditions.

This paper discusses the behaviour of angiotensin 1 and neurotensin together with their metabolites in a three-phase liquid phase microextraction under acidic conditions. Variations in donor phase, organic phase, and acceptor phase are studied with extraction recovery as response variable. It is proved that for all peptides the transport across the organic phase is mediated by heptane-1-sulphonic acid. n-Octanol gave overall best results as organic phase. A donor phase volume of 1.0 mL was chosen as a compromise between optimal recovery and robustness of the LPME device. The optimal pH of the donor phase (using acceptor phase of pH 2) was found to be different for the peptides, which opens opportunities for selective sample preparation. Decreasing the acceptor phase pH to 1.0 resulted in increased extraction recoveries. On using 1.0 mL of donor phase containing 50 mM heptane-1-sulphonic acid pH 3, n-octanol as organic phase immobilized in the pores of the fibre, and 20 microL of acceptor phase containing 0.1 mol/L HCl, extraction recoveries up to 82% (enrichment factor = 41) were achieved. To our knowledge this is the first report on liquid phase microextraction of angiotensins and neurotensins.

Angiotensins↗

Determination of pesticides in soil by liquid-phase microextraction and gas chromatography-mass spectrometry.

Trace amounts of pesticides in soil were determined by liquid-phase microextraction (LPME) coupled to gas chromatography-mass spectrometry (GC-MS). The technique involved the use of a small amount (3 microl) of organic solvent impregnated in a hollow fiber membrane, which was attached to the needle of a conventional GC syringe. The organic solvent was repeatedly discharged into and withdrawn from the porous polypropylene hollow fiber by a syringe pump, with the pesticides being extracted from a 4 ml aqueous soil sample into the organic solvent within the hollow fiber. Aspects of the developed procedure such as organic solvent selection, extraction time, movement pattern of plunger, concentrations of humic acid and salt, and the proportion of organic solvent in the soil sample, were optimized. Limits of detection (LOD) were between 0.05 and 0.1 microg/g with GC-MS analysis under selected-ion monitoring (SIM). Also, this method provided good precision ranging from 6 to 13%; the relative standard deviations were lower than 10% for most target pesticides (at spiked levels of 0.5 microg/g in aqueous soil sample). Finally, the results were compared to those achieved using solid-phase microextraction (SPME). The results demonstrated that LPME was a fast (within 4 min) and accurate method to determine trace amounts of pesticides in soil.

Gas Chromatography-Mass Spectrometry↗

Dynamic liquid-phase microextraction with HPLC for the determination of phoxim in water samples.

A new method, which involves dynamic liquid-phase microextraction followed by HPLC with variable wavelength detection, was developed to determine phoxim in water samples. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, sampling volume, dwell time, number of samplings, and salt concentration were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 10 microg/mL. The LOD is 2 ng/mL, and RSD at the 100 ng/mL levels is 8.9%. Lake water and tap water samples were successfully analyzed using the proposed method.

Chromatography, High Pressure Liquid↗

Identification of volatile basic components in tobacco by headspace liquid-phase microextraction coupled to matrix-assisted laser desorption/ionization with Fourier transform mass spectrometry.

A method incorporating headspace liquid-phase microextraction (HS-LPME) coupled to matrix-assisted laser desorption/ionization (MALDI) with Fourier transform mass spectrometry (FTMS) was established to analyze volatile basic components in tobacco. The sample preparation volume for MALDI-MS was compatible with the volume of the solvent microdrop in the HS-LPME procedure. The pH and the polarity of the solvent for HS-LPME were adjusted by choice of the MALDI matrix and matrix additive. Based on the elemental composition and tandem mass spectrometry information, 25 volatile nitrogenous compounds in tobacco were detected and identified. The approach is fast and sensitive, and has the potential for automation for high-throughput analysis. This approach offers an alternative method for analysis of trace volatile organic compounds in complex samples.

Gas Chromatography-Mass Spectrometry↗

Use of ionic liquids for liquid-phase microextraction of polycyclic aromatic hydrocarbons.

This paper demonstrates, for the first time, that ionic liquids (IL) such as 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM][PF(6)]) are excellent extraction solvents in liquid-phase microextraction (LPME). The unique properties of nonvolatility and adequate viscosity allow IL to be conveniently adopted as extraction solvents in both direct-immersion and headspace LPME. Model compounds, polycyclic aromatic hydrocarbons (PAHs), are conveniently and rapidly enriched in a 3-microL drop of [C(8)MIM][PF(6)] suspended on the tip of a microsyringe followed by liquid chromatographic determination. Compared to 1-octanol, a larger volume drop of [C(8)MIM][PF(6)] can be formed and survive for a longer extraction time; therefore, a much higher enrichment factor for PAHs can be reached. For low-volatility PAHs, direct-immersion LPME provides higher enrichment factors than that of headspace LPME. However, the enrichment factor obtained by headspace LPME was almost 3-fold of that by direct-immersion LPME in a 30-min extraction of the most volatile PAH, naphthalene. For 30-min direction-immersion LPME of EPA priority PAHs, the enrichment factor, correlation coefficient (R(2)), and reproducibility (RSD, n = 5) were in the range of 42-166, 0.9169-0.9976, and 2.8-12%, respectively. Considering that IL can be easily prepared from relatively inexpensive materials and tuned by combination of different anions and cations for task-specific extraction of analytes from various solvent media, this proposed method should have great potentiality in sample preparation. Furthermore, the nonvolatility of IL makes it potentially useful for headspace LPME of volatile analytes.

Journal Article↗

Liquid-phase microextraction as an on-line preconcentration method in capillary electrophoresis.

A simple and efficient sample preconcentration method for capillary electrophoresis has been developed using liquid-phase microextraction (LPME). A thin layer of an organic liquid was used to separate a drop of the aqueous acceptor phase hanging at the inlet of a capillary from the bulk aqueous donor phase. The donor-phase pH was 1.0, and the acceptor phase pH was 9.5. This pH difference caused the preconcentration of the acidic compounds, fluorescein and fluorescein isothiocyanate, into the acceptor-phase drop. Enrichment factors of 3 orders of magnitude were obtained with 30-min LPME at 35 degrees C.

Journal Article↗

Liquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry.

Two modes of liquid-phase microextraction (LPME) combined with hollow fiber (HF) were developed for gas chromatography/mass spectrometry (GC/MS). Both methodologies, that is, static LPME with HF and dynamic LPME with HF, involved the use of a small volume of organic solvent impregnated in the hollow fiber, which was held by the needle of a conventional GC syringe. In static LPME/HF, the hollow fiber impregnated with solvent was immersed in the aqueous sample, and the extraction processed under stirring; in dynamic LPME/HF, the solvent was repeatedly withdrawn into and discharged from the hollow fiber by a syringe pump. This is believed to be the first reported instance of a semiautomated liquid microextraction procedure. The performance of the two techniques was demonstrated in the analysis of two PAH compounds in an aqueous sample. Static LPME/HF provided approximately 35-fold enrichment in 10 min and good reproducibility (approximately 4%). Dynamic LPME/HF could provide higher enrichment (approximately 75-fold) in 10 min and even better reproducibility (approximately 3%). Both methods allow the direct transfer of extracted analytes to a GC/MS system for analysis.

Journal Article↗

Liquid-phase microextraction as a sample preparation technique prior to capillary gas chromatographic-determination of benzodiazepines in biological matrices.

Liquid-phase microextraction (LPME) and gas chromatography were applied to determine diazepam and the main metabolite N-desmethyldiazepam in human urine and plasma. The analytes were extracted from 3.0-3.5 ml sample volumes directly into 25 microl of extraction solvent. The microextraction device consisted of a porous hollow fiber of polypropylene attached to two guiding needles inserted through a septum and a 4 ml vial. The hollow fiber filled with extraction solvent was immersed in sample solution. The extraction device was continuously vibrated at 600 rpm for 50 min. An aliquot (1 microl) of the extraction solvent with preconcentrated analytes was injected directly into the capillary gas chromatograph. Thirty samples were extracted simultaneously on the vibrator, providing a high sample capacity. The limits of detection were from 0.020 to 0.115 nmol/ml for diazepam and N-desmethyldiazepam in plasma and urine using a nitrogen-phosphorus detector (NPD).

Chromatography, Gas↗

Liquid-phase microextraction utilising plant oils as intermediate extraction medium--towards elimination of synthetic organic solvents in sample preparation.

Hollow fibre based liquid-phase microextraction (LPME) using fatty oils and essential oils as the organic phase was evaluated to develop sample preparation technology eliminating the use of hazardous organic solvents. Basic drugs were extracted from different aqueous samples (0.2 to 1 mL) through approximately 15 microL of either almond oil, arachis oil, olive oil, soy-bean oil, anise oil, fennel oil, lavender oil, or peppermint oil (organic phase) immobilised within the pores of a polypropylene hollow fibre and into 20 microL of 10 mM HCOOH (acceptor phase) present inside the lumen of the hollow fibre. The extraction performance of the essential oils was comparable with the solvents normally used in LPME (dihexyl ether, n-octanol, and dodecyl acetate) in terms of extraction recovery and extraction speed. Whereas all essential oils tested were compatible with human urine, only anise oil was successful for plasma. The fatty oils provided lower recoveries than the essential oils due to higher viscosity, but all the fatty oils were compatible both with urine and plasma samples. In spite of the multi-component nature of the oils tested, they were not found to seriously contaminate the acceptor phases during extraction. In conclusion, fatty oils and essential oils may serve as alternative organic phase in LPME, eliminating the use of hazardous organic solvents.

Mentha piperita↗

Injection port derivatization following ion-pair hollow fiber-protected liquid-phase microextraction for determining acidic herbicides by gas chromatography/mass spectrometry.

Injection port derivatization following ion-pair hollow fiber-protected liquid-phase microextraction (LPME) for the trace determination of acidic herbicides (2,4-dichlorobenzoic acid, 2,4-dichlorophenoxyacetic acid, 2-(2,4-dichlorophenoxy)propionic acid, 3,5-dichlorobenzoic acid, 2-(2,4,5-trichlorophenoxy)propionic acid) in aqueous samples by gas chromatography/mass spectrometry (GC/MS) was developed. Prior to GC injection port derivatization, acidic herbicides were converted into their ion-pair complexes with tetrabutylammonium chloride in aqueous samples and then extracted by 1-octanol impregnated in the hollow fiber. Upon injection, ion pairs of acidic herbicides were quantitatively derivatized to their butyl esters in the GC injection port. Thus, several parameters related to the derivatization process (i.e., injection temperature, purge-off time) were evaluated, and main parameters affecting the hollow fiber-protected LPME procedure such as extraction organic solvent, ion-pair reagent type, pH of aqueous medium, concentration of ion-pair reagent, sodium chloride concentration added to the aqueous medium, stirring speed, and extraction time profile, optimized. At the selected extraction and derivatization conditions, no matrix effects were observed. This method proved good repeatability (RSDs <12.3%, n = 6) and good linearity (r2 > or = 0.9939) for spiked deionized water samples for five analytes. The limits of detection were in the range of 0.51-13.7 ng x L(-1) (S/N =3) under GC/MS selected ion monitoring mode. The results demonstrated that injection port derivatization following ion-pair hollow fiber-protected LPME was a simple, rapid, and accurate method for the determination of trace acidic herbicides from aqueous samples. In addition, this method proved to be environmentally friendly since it completely avoided open derivatization with potentially hazardous reagents.

Acids↗

Liquid-phase microextraction combined with capillary electrophoresis, a promising tool for the determination of chiral drugs in biological matrices.

A disposable device for liquid-phase microextraction (LPME) based on porous polypropylene hollow fibres has recently been introduced. In the present paper, LPME was combined with capillary electrophoresis (CE) and the combination was for the first time evaluated for chiral determination of drugs in biological matrices. The chiral antidepressant drug mianserin was selected as model compound. The mianserin enantiomers were extracted from 0.5 ml of plasma added internal standard and made alkaline with 0.25 ml of 2 M NaOH. The unionised analytes were extracted into di-n-hexyl ether impregnated in the pores of the hollow fibre, and into an acidic solution inside the hollow fibre. This resulted in a three-phase system where the extracts were aqueous, and hence directly compatible with the CE system. Efficient sample clean-up was seen and the extraction recovery was 80% for both enantiomers. Discrimination between the enantiomers in the extraction system was not observed. The limit of quantitation (S/N= 10; 12.5 ng/ml for both enantiomers) and the limit of detection (S/N=3; 4 ng/ml for both enantiomers) were below the therapeutic range for mianserin. The method was validated and successfully applied to determine R- and S-mianserin in plasma samples from seven patients treated with mianserin, indicating that LPME-CE is a promising combination for analysis of racemic drugs present in low concentrations in biological matrices.

Calibration↗

Ionic liquid for high temperature headspace liquid-phase microextraction of chlorinated anilines in environmental water samples.

Based on the non-volatility of room temperature ionic liquids (IL), 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) IL was employed as an advantageous extraction solvent for high temperature headspace liquid-phase microextraction (LPME) of chloroanilines in environmental water samples. At high temperature of 90 degrees C, 4-chloroaniline, 2-chloroaniline, 3,4-dichloroaniline, and 2,4-dichloroaniline were extracted into a 10 microl drop of [C4MIM][PF6] suspended on the needle of a high-performance liquid chromatography (HPLC) microsyringe held at the headspace of the samples. Then, the IL was injected directly into the HPLC system for determination. Parameters related to LPME were optimized, and high selectivity and low detection limits of the four chlorinated anilines were obtained because the extraction was performed at high temperature in headspace mode and the very high affinity between IL and chlorinated anilines. The proposed procedure was applied for the analysis of the real samples including tap water, river water and wastewater samples from a petrochemical plant and a printworks, and only 3,4-dichloroaniline was detected in the printworks wastewater at 88.2 microg l(-1) level. The recoveries for the four chlorinated anilines in the four samples were all in the range of 81.9-99.6% at 25 microg l(-1) spiked level.

Aniline Compounds↗

Determination of trace level chemical warfare agents in water and slurry samples using hollow fibre-protected liquid-phase microextraction followed by gas chromatography-mass spectrometry.

A simple and solvent-minimised sample preparation technique based on hollow fibre-protected liquid-phase microextraction was investigated for the gas chromatography/mass spectrometric analysis of chemical warfare agents in water and slurry samples. The chemical warfare agents included four nerve agents and a blister agent. Parameters such as extraction solvent, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The technique provided a linear range of two orders of magnitude, good repeatability (RSDs < 10%, n = 6), good linearity (r2 >or= 0.995) and limits of detection (LODs) in the range of 0.02-0.09 microg l(-1) (S/N = 3) under full scan mode. The optimised technique was also applied to more complex slurry samples and similar precision (RSD < 15%, n = 3) and limits of detection (0.02-0.2 microgl(-1), S/N = 3) were obtained.

Chemical Warfare Agents↗

Ion-pair dynamic liquid-phase microextraction combined with injection-port derivatization for the determination of long-chain fatty acids in water samples.

Ion-pair dynamic liquid-phase microextraction coupled to injection-port derivatization has been developed for the determination of long-chain fatty acids in water samples by gas chromatography-mass spectrometry (GC-MS). In this procedure, long-chain fatty acids (C(14), C(16) and C(18)) were converted into their ion-pair complexes with tetrabutylammonium hydrogen sulfate and then extracted by organic solvent (1-octanol) impregnated in the hollow fiber. The dynamic nature of the extraction was represented by the repeated movement of the acceptor phase (organic solvent) in the hollow fiber that was controlled by a syringe pump. Ion pairs of fatty acids quantitatively formed butyl esters in the injection-port of the gas chromatography. Several parameters such as injection temperature, purge-off time, organic solvent, ion-pair reagent, pH, agitation speed, extraction time and the syringe pump parameters (plunger speed and dwell time) have been optimized. The limits of detection were in the range 0.0093-0.015 ng mL(-1) (at a signal-to-noise ratio of 3) under GC-MS-selected ion monitoring mode and the relative standard deviations were between 7.7% and 11.5%. The method was successfully applied to measure long-chain fatty acids in real water samples.

Chemical Fractionation↗

Liquid phase microextraction with in situ derivatization for measurement of bisphenol A in river water sample by gas chromatography-mass spectrometry.

A new method that involves liquid phase microextraction (LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) is described for the determination of trace amounts of bisphenol A (BPA) in river water samples. The LPME conditions, such as the type of extraction solvent and the extraction time, are investigated. Then, the extract is directly injected into GC-MS. The detection limit and the quantification limit of BPA in river water sample are 2 and 10pgml(-1) (ppt), respectively. The calibration curve for BPA is linear with a correlation coefficient of >0.999 in the range of 10-10,000pgml(-1). The average recoveries of BPA in river water samples spiked with 100 and 1000pgml(-1) BPA are 104.1 (RSD: 8.9%) and 98.3 (RSD: 3.2%), respectively, with correction using the added surrogate standard, bisphenol A-(13)C(12). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of BPA in liquid samples.

Benzhydryl Compounds↗

Liquid-phase microextraction of protein-bound drugs under non-equilibrium conditions.

Recently, we introduced an inexpensive and disposable hollow fiber-based device for liquid-phase microextraction (LPME) where ionic analytes typically were extracted and preconcentrated from 1-4 mL aqueous samples (such as plasma and urine) through an organic solvent immobilized in the pores of a polypropylene hollow fiber and into a 10-25 microL volume of acceptor phase present inside the lumen of the hollow fiber. Subsequently, the acceptor phase was directly subjected to the final analysis by a chromatographic or electrophoretic method. In the present work, attention was focused on LPME of the basic drugs amphetamine, pethidine, promethazine, methadone and haloperidol characterized by substantial differences in the degree of protein binding. Drug-protein interactions in plasma resulted in reduced recoveries and substantially increased extraction times compared with extraction of the drugs from a pure water matrix. However, by addition of 5-50% methanol to the plasma samples, recoveries were comparable with LPME from water samples and ranged between 75 and 100%. The addition of methanol was found not to speed up the LPME process and extractions from plasma were performed in 45 min to reach equilibrium. Because approximately 55-70% of the final analyte concentrations were achieved within the initial 10 min of the LPME process, validation was accomplished after 10 and 45 min of LPME. In general, the results with 10 and 45 min were almost comparable, with precision data in the range 1.2-11.1% (RSD) and with linearity in the concentration range 20-1000 ng mL(-1) (r = 0.999). In conclusion, excellent LPME results may be achieved in a short time under non-equilibrium conditions with a minor loss of sensitivity. In cases of drug-protein interactions, methanol may be added to ensure a high extraction recovery.

Amphetamine↗