Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Insertion--complications”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Postoperative continuous interscalene brachial plexus blockade for hand surgery.

Interscalene brachial plexus blockade is a well-established means of providing analgesia and anesthesia for upper extremity surgery. Extension into the postoperative period with continuous infusions of 0.25% bupivacaine provides several added advantages. Our survey over two years covered 126 patients undergoing surgery by the Department of Hand Surgery of our hospital. Postoperative verbal analogue pain scores obtained for three days showed scores of 4 or less (range 0 to 10) being reported by more than 70% of all patients with 6.3% and 11.9% requiring additional narcotics and non-steroidal anti-inflammatory drugs, respectively. Compliance with early occupational therapy was good with only 7 patients having difficulty with active mobilisation as a result of excessive motor blockade. The insertion complication rate was 11.1%; all these cases were attributed to the bolus dose given and resolved over the next few hours. Eighteen (14.3%) of the patients developed complications while on continuous infusion, the most frequent being catheter dislodgement and pain at the insertion site. In all we found this method of providing postoperative analgesia to be effective, inexpensive and easy to implement in our large hospital setting.

Adult↗

[Endoscopic management of benign strictures of the common bile duct].

UNLABELLED: 3 females with benign hepatic duct strictures were treated endoscopically. The treatment consisted of placement of one or two endoprostheses in all cases and endoscopic balloon dilatation in two cases. The stent was removed from the first patient--who had hepatic duct stones as well--after a 15 months stenting period and mechanical lithotripsy and balloon dilatation were performed with good results. The second and third patient-after stent insertion--was operated with suspicion of malignancy. Tumor was not proved. In the second patient the endoscopically placed stent was changed by a large diameter teflon stent surgically. The third patient's stents were left in place. These stents were removed after 3 months and balloon dilatation was performed. Patients' jaundice subsided and cholangitis improved following the stent insertion. COMPLICATIONS: Stent occlusion developed and common bile duct stones occurred once. There was not observed any other complication. Benign hepatic duct strictures can be treated by combination of prolonged endoscopic biliary stenting and balloon dilatation successfully.

Adult↗

Acute complications of central line placement in profoundly thrombocytopenic cancer patients.

BACKGROUND: Morbidities associated with the insertion of central venous catheters in severely thrombocytopenic cancer patients were analyzed in this prospective observational study. One hundred fifteen consecutive thrombocytopenic patients requiring central venous access (internal jugular or subclavian vein cannulation by a modified Seldinger technique) were evaluated. METHODS: One hundred fifteen catheters were inserted. For each patient, the following factors were documented: age; sex; diagnosis; previous catheterization; prior neck, chest, breast, or axillary surgery or radiation therapy; presence of other lines prior to venipuncture; site and indication for line insertion; complications; PT and PTT; platelet counts; and hematocrit. RESULTS: Of the total number of catheters inserted, 63 (55%) were subclavian and 52 (45%) were internal jugular. Successful cannulations with no complications (n = 91; 79% of the total) were achieved with 1.2 +/- 0.5 attempts. Twenty-four major and minor complications (20%) occurred with an average of 1.6 +/- 1 attempts (P = 0.003). The mean preprocedure platelet counts were 14.8 +/- 4.5 x 10(9)/L for the subclavian group and 14.3 +/- 4.8 x 10(9)/L for the internal jugular group. With platelet transfusion, the mean postprocedure platelet counts for the subclavian and internal jugular groups were 23.9 +/- 12.8 x 10(9)/L and 24.6 +/- 15 x 10(9)/L, respectively. In the subclavian group, seven patients (6%) experienced minor complications. There were 17 minor complications (15%) and 1 pneumothorax in the internal jugular group. Patients experiencing more than one attempt at cannulation had more complications (P = 0.003). CONCLUSIONS: With the appropriate precautions and platelet transfusions, central venous catheters can be inserted safely with minimal complications into thrombocytopenic cancer patients. Fewer attempts are associated with fewer complications. High risk procedures should be attempted only by experienced personnel or under their direct and strict supervision.

Adult↗

Venous interruption as prophylaxis of pulmonary embolism: vena cava filters.

Interruption of vena cava for prevention of pulmonary embolism (PE) was achieved in the past with surgical ligation or placement of clips outside the infrarenal vena cava. At present, this procedure is performed with percutaneous insertion of vena cava filters. Vena cava filters can be permanent or temporary, catheter-retrievable. Main indications for placement of a vena cava filter are: contraindication for anticoagulant therapy in patients with severe PE in whom a further embolic episode would be fatal or patients with PE (or its recurrence) undergoing adequate anticoagulant therapy. Temporary filters are reserved to patients where the risk of PE is limited in time as in posttraumatic, post-partum or postoperative thromboembolism. The incidence of recurrence after placement of a vena cava filter varies between 0.5 and 7%. Procedure-associated complications are usually mild. However, severe complications as filter migration into the pulmonary artery or vena cava perforation were described. Our experience concerns the insertion of 61 vena cava filters (47 permanent and 14 temporary). Indications were as follows: iliofemoral thrombosis at embolic risk (37 cases), contraindication for anticoagulant therapy in the presence of deep vein thrombosis with embolic risk (7 cases), protection during fibrinolytic therapy (3 cases), PE during anticoagulant therapy (5 cases) complications of anticoagulant therapy which required discontinuation (5 cases), prophylaxis in view of surgery at high risk for PE (2 cases), protection for surgical venous thrombectomy (2 cases). Mortality was nil. Clinically evident PE was not observed in any patient in whom vena cava filter was inserted. Complications were mild and asymptomatic. Vena cava filters represent an effective prevention of PE together with medical and surgical treatment. At present, problems of this procedure are not technical but rather concern correct indications. Interruption of vena cava is effective if planned within a global strategy for prevention of thromboembolism.

Adolescent↗

Subcutaneously implanted central venous access devices in cancer patients: a prospective analysis.

BACKGROUND: Long term intravenous access is a common requirement for cancer patients. This analysis was designed to determine device-related morbidity and factors predictive of poor long term outcome for patients with subcutaneous single lumen intravenous access ports. METHODS: Six hundred eighty patients who underwent subcutaneous intravenous port placement between June 1987 and May 1989 at Memorial Sloan-Kettering Cancer Center were followed prospectively until port removal, death, or a maximum of 1960 days. Indications for and circumstances of placement, patient diagnoses, patient demographics, and subsequent courses of treatment were recorded, as well as technical and microbiologic device-related complications. Total, device specific, and complication free device durations were calculated. RESULTS: The median patient age was 52.4 years (range, 1.6-83.9 years). The female-to-male ratio was 1.5 to 1. Cancer diagnoses included solid organ tumors (84%), leukemia (4%), lymphoma (11%), and others (1%). Indications included access for systemic chemotherapy (98%), total parenteral nutrition (0.5%), and others (1.5%). One insertion complication and six insertion failures occurred, without mortality. The estimated mean overall actuarial device specific duration was 1191 days (range, 2-1960 days). Actuarial mean complication free, device specific duration was 952 days. Complications included sepsis (n = 31; 4.4%), site infection (n = 31; 4.4%), and accessibility failures such as thrombosis and leakage (n = 40, 5.7%). Reasons for end of port duration were patient death (72.4%), end of treatment (13.5%), functional failure or intractable infection (11.2%), and others (2.9%). Independent factors correlating with decreased port specific, complication free duration included placement site, age, tumor type, and catheter tip position. CONCLUSIONS: Subcutaneous intravenous access ports in cancer patients are safe and well tolerated. Long term device duration is primarily influenced by patient survival. In this study, 90% of patients alive at 1 year and 70% of patients alive at 4 years had a functional port.

Adolescent↗

[The principles of designing stump pin inserts in pathological tooth abrasion].

A total of 278 patients aged 40 to 67 with pathological abrasion of hard dental tissues were treated. Decreased occlusion height was diagnosed in 152 (54.67%) of these. In 146 patients abutment teeth under permanent dentures were fixed with cast stump pin insertions. Complications occurred in 9.6% cases: perforation of the wall of the root canal (1.14%), failure of cementing (3.98%), fracture of the root (1.14%), breaking of a fragment of the root at the neck of the tooth (2.84%), and inflammations of the marginal periodontium (0.57%). In order to prevent these complications and improve the fixation of cast stump pin insertion, we used our modifications of cast stump pin insertions (n = 394) for anterior and lateral teeth. The incidence of complications decreased more than 5 times. Follow-up of 2 to 8 years showed 1.78% of complications.

Adult↗

Complications associated with pulmonary artery catheterization.

OBJECTIVE: To review the literature addressing complications associated with pulmonary artery catheterization. DATA SOURCE: All pertinent English language articles dealing with complications associated with pulmonary artery catheterization were retrieved from 1979 through 1996. STUDY SELECTION: Articles were chosen for review if the primary objective of the paper was complications associated with pulmonary artery catheterization. DATA EXTRACTION: From the literature selected, information was obtained about frequency and types of complications associated with pulmonary artery catheterization. DATA SYNTHESIS: Complications are grouped into three categories: complications associated with insertion, complications associated with indwelling catheters, and complications that occur during or after removal of the catheter. CONCLUSION: With the introduction of any new technology, there are risks and potential complications. Pulmonary artery catheterization was introduced in 1970 and has not been without complications and controversy. Recent research findings have again led to the discussion of the efficacy and safety of pulmonary artery catheter (PAC) use. This article discusses complications associated with pulmonary artery catheterization and makes recommendations for future research and continued safe use of the PAC.

Catheterization, Swan-Ganz↗

The Italian Registry of Pediatric Chronic Peritoneal Dialysis: a ten-year experience with chronic peritoneal dialysis catheters.

OBJECTIVE: To analyze the data from 347 peritoneal catheters implanted in 249 pediatric patients aged < or = 15 years at start of chronic peritoneal dialysis (CPD). DESIGN: Restrospective study of the data collected between 1986 and 1995, in 20 dialysis centers, from the Italian Registry of Pediatric Chronic Peritoneal Dialysis. Data collection for each pediatric catheter included: catheter type, site and technique of insertion, complications, duration, and reason for removal or replacement. RESULTS: Fifty catheters were inserted in patients under 2 years of age, 50 in patients aged 2 - 5 years and 247 in patients over 5 years of age. Catheter types included 307 (88.5%) Tenckhoff (286 double cuff, 21 single cuff) and 40 (11.5%), double-cuff, Valli-type catheters. All catheters were surgically implanted and omentectomy was performed in 83.5% of cases; the entry-site was in the midline in 136 cases (39.2%) and paramedian in 211 (60.8%). During 6076 CPD months we observed 274 catheter-related complications: 182 catheter infections (exit-site and/or tunnel infection), 23 leakages, 19 obstructions, 19 cuff-extrusions, 14 dislocations, 6 hemoperitoneum, 10 other (incidence of one complication every 21.8 dialysis-months). A significant reduction of catheter-related complications occurred in the last five years, compared with the first 5 years. One hundred and six catheters were removed due to catheter-related causes: infection (83 cases), obstruction (11), dislocation (4), outer-cuff extrusion (3), leakage (2), bowel incarceration (2), and bowel infarction (1). Catheter survival was 72.2% at 12 months, 52.3% at 24 months, 32.8% at 36 months, and 25.7% at 48 months. Significantly lower catheter survival was found in younger children (0 - 2 years) compared with two other age groups (2 - 5 years, and > 5 years). No significant correlation was found between catheter survival and catheter entry-site (midline vs paramedian). CONCLUSIONS: Catheter-related infections were confirmed to be the most common complication and most frequent cause of peritoneal catheter removal. In addition, catheter survival rate was worse in younger children, indicating that more effort should be made to improve peritoneal catheter survival particularly in this age group.

Adolescent↗

Resolved: A pulmonary artery catheter should be used in the management of the critically ill patient. Pro.

Selected studies showing both positive and negative outcomes with the use of pulmonary artery catheters (PACs) are reviewed. Indications for use of a PAC are controversial, although clearly the "red cap syndrome" is an indication for its insertion. There are sufficient data as well as personal experience to suggest that PACs do make a difference in the management of critically ill patients. Attention is focused on the level of physician expertise in interpreting data provided by PAC monitoring as the most critical limitation on the physician's ability to make appropriate clinical decisions. Studies are reviewed that addressed physician level of expertise related to PAC insertion, complications, data and waveform interpretation, and management. User knowledge clearly is suboptimal. Before attempting to draw conclusions from outcome studies, criteria for appropriate use need to be developed and clinician knowledge needs to be significantly improved.

Cardiac Output↗

Post-cardiotomy intra-aortic balloon counter pulsation: application and prognostic evaluation.

Cardiac assistance by intra-aortic balloon counter pulsation was studied in 113 cardiac surgical cases comprising 91 male and 22 female patients. This included 82 percent of patients having coronary artery bypass surgery, while 18 percent were operated for valvular lesions. It was observed that the time of institution of cardiac assistance by intra-aortic balloon counter pulsation, following cardiac surgery, was of prime importance to decrease patient mortality. It was lowest (16%) when the balloon was inserted for assistance before termination and highest (50%) when there was delay of more than 15 minutes following termination of cardiopulmonary bypass. Early balloon assistance significantly lowered the pulmonary capillary wedge pressure and usually 1:2 augmentation was more effective, probably because of existing tachycardia in most patients. Advances in catheter technology have reduced the vascular complication at the insertion site. Percutaneous insertion had less local complications (13.3%) than open arteriotomy technique (31.2%). Similarly with sheathless insertion, complications were less (6.6%) in comparison to sheathed insertion (21.7%). Proper placement of balloon avoided position-related complications and there was no compromise of blood flow through left internal mammary artery as noticed in our series.

Adolescent↗

Incidence, prevalence, and trends of acute pelvic inflammatory disease and its consequences in industrialized countries.

Pelvic inflammatory disease is used herein synonymously with acute salpingitis. In modern industrialized countries, the annual incidence of PID in women 15 to 39 years of age seems to be 10 to 13 per 1,000 women, with a peak incidence of about 20 per 1,000 women in the age group 20 to 24 years. Since 1960 an increase in incidence by a factor of 1.6 to 1.9 has been observed in the age group 20 to 29 years. The incidence of PID is correlated strongly with the prevalence of sexually transmitted diseases, although a fraction of the infections might be of endogenous origin. Use of intrauterine contraceptive devices and operations for legal abortions contribute to the increase in incidence. The prevalence of women in the post-PID state has increased by a factor of about 1.5 since 1960. Women in the post-PID state have a tenfold increased risk for ectopic pregnancy and 25% of the increase in ectopic pregnancy can be accounted for by the increase in post-PID women. Infertility after PID ranges between 5.8% and 60% depending on severity of infection, number of infections, and age of the women. The fraction of women rendered infertile because of PID has increased by a factor of about 1.6 since 1960.

Adolescent↗

Do insertion-related problems affect subsequent IUD performance?

This investigation compares the IUD performance of 372 women who had an insertion-related problem (most with moderate or severe pain) and 372 matched women who had no such problem; all women had interval insertion. A woman in the Problem Cohort and her matched counterpart in the Comparison Cohort were inserted with the same IUD type by the same insertor on the same day or on close dates. The six IUD types used by these women were Lippes Loop D, Copper-7, Copper T-200, Copper T-380 Ag, Multiload Copper 250 and Multiload Copper 375. Cumulative gross life-table rates of the pertinent events (accidental pregnancy, expulsion and medical removal for bleeding and pain), adjusted for age and parity, were calculated. Between the Problem Cohort and the Comparison Cohort, no differences were detected in the event rates that were of either statistical or practical significance. Results from this preliminary study suggest that the insertion-related problems usually encountered during interval insertion such as insertion pain, syncope and/or mild cervical laceration are not associated with an increased risk of IUD discontinuation due to pertinent events.

Adult↗

Intrauterine devices and pelvic inflammatory disease: recent developments.

The potential relationship between use of intrauterine devices and pelvic inflammatory disease is one of the most important issues in contraception today. A number of large, sophisticated studies published since mid-1980 have clarified this association. All have consistently revealed an increased risk of pelvic inflammatory disease among intra-uterine device users, but the most objective of these studies indicate a relative risk compared to women using no method (1.5-2.6) lower than previous estimates. For most intrauterine device wearers, the increased risk of pelvic inflammatory disease persists for only a few months after insertion. The Dalkon Shield appears associated with a higher risk of pelvic inflammatory disease than the Lippes Loop, Saf-T-Coil, or copper devices. Careful selection of candidates for intrauterine devices may further reduce the risk of intrauterine device-associated pelvic inflammatory disease.

Female↗

A randomized trial of the Gyne T 380 and Gyne T 380 Slimline Intrauterine Copper devices.

To facilitate manufacture and insertion of the Gyne T 380 IUD, design changes were instituted. Copper collars were seated flush at the ends of the horizontal crossbar of the device. A randomized study of the Gyne T 380 Slimline, the new design, was undertaken in comparison with the standard Gyne T 380. A total of 996 women were enrolled, with 698 Slimline insertions and 298 of the standard Gyne T. No statistically significant difference in ease of insertion or in performance was detected between the models. At one year, the pregnancy rate of each model was below 0.5 per 100 and the continuation rate was 79-80 per 100. Pelvic inflammatory disease or endometritis was found in one percent of subjects in the first year. This is the seventh multicenter randomized study of a collared T IUD with 380 mm2 of copper surface. In all seven, the one-year gross pregnancy rate has been 1.2 per 100 or lower.

Adult↗

A comparison of prostaglandin E2 pessaries and laminaria tents for ripening the cervix before termination of pregnancy.

Forty primigravid women aged 15-45 years were randomly allocated to receive either an intravaginal pessary of 3 mg prostaglandin E2 (PGE2) or an intracervical 5-mm laminaria tent (LT) 12-16 h before termination of pregnancy at 6-14 weeks gestation. The degree of dilatation of the cervix at operation and its resistance to further dilatation during the procedure were assessed by a 'blind' operator. Laminaria tents were more effective in achieving dilatation and softening of the cervix than were PGE2 pessaries and in 40% of women no further dilatation was necessary. There were no associated side-effects or complications. A cervical tear occurred in two of 20 patients treated with PGE2 pessaries and all 20 required further dilatation of the cervix. Laminaria tents provide a simple, safe, acceptable and effective means of 'ripening' the cervix prior to termination of early pregnancy.

Abortion, Therapeutic↗

Experience of Finnish women with Norplant insertions and removals.

OBJECTIVE: Norplant and Norplant-2 have been available for use by Finnish women since 1984 and 1986, respectively. The objective of this study was to explore Norplant users' experiences of insertions, removals and medical treatments. DESIGN: A questionnaire was sent to women who had received Norplant or Norplant-2 implants one to two years earlier (n = 262) in normal clinical settings; the response rate was 79%. RESULTS: At insertion, problems were experienced by 9% and at least some pain by 23% of women. During the first year 20% of all users (14% of Norplant and 33% of Norplant-2 users) had their implants removed. Problems were experienced at removal by 33% of women and pain was experienced by 40%; nevertheless most users were satisfied with the device. Findings were similar for the two types of Norplant. Forty-two percent of the women had received minipills containing levonorgestrel before Norplant insertions in an attempt to assess Norplant's suitability, and 8% had received drugs for adverse effects caused by Norplant. CONCLUSIONS: Studies including perspectives of Norplant users and the whole lifespan of Norplant (including removal) should be conducted in all clinical settings where Norplant is provided.

Contraceptive Agents, Female↗

Insertion and removal of Norplant contraceptive implants by physicians and nonphysicians in an Indonesian clinic.

This paper reports on a study in which the performances of physicians were compared to those of nonphysician health personnel in inserting and removing NORPLANT subdermal contraceptive implants. The study was conducted in Raden Saleh Clinic at the University of Indonesia, Jakarta, from September 1982 to August 1984. In a group of 828 women who accepted NORPLANT 285 insertions were performed by physicians and 543 by nonphysician health personnel. During the study period, 122 removals were performed (43 by physicians and 79 by nonphysicians). This small proportion of removals reflects the high continuation rate for NORPLANT. There was no significant difference between the two groups of acceptors regarding age, parity, education, or side effects. The average insertion times were 7.6 minutes for the physician group and 7.4 minutes for the nonphysician group (p greater than 0.1). The average removal times were 21.7 minutes for physicians and 21.8 minutes for nonphysicians (p greater than 0.9). Complications during and following insertion and removal were minimal for both groups, and no significant differences were found. It was concluded that nonphysician health personnel are qualified to administer the NORPLANT contraceptive implants.

Adult↗

Immediate postabortion intrauterine contraception in nulliparous adolescents.

Immediate postabortion insertion of an intrauterine device (IUD) was performed in 162 nulliparous adolescents. No insertion failures occurred. Twelve-month continuation rates were 86.6% for the Copper-7 IUD, 75.4% for the Copper-T device and 48.2% for the Lippes loop. Overall complications were greater for the Lippes loop than for the other two devices. The results suggest that immediate postabortion insertion should be considered for poorly motivated or uneducated adolescent girls who have already failed in contraception and require abortion.

Abortion, Induced↗