Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques.

We developed an integrated array of needle-type biosensors employing a novel process of fabrication, comprising conventional semiconductor fabrication and micromachining technology. Amperometric sensing electrodes with plasma-polymerized films and a thin-film Ag/AgCl reference electrode were directly integrated on a glass substrate with thin-film process, e.g., sputtering. An enzyme was immobilized on the electrode via the plasma-polymerized film, which was deposited directly on the substrate using a dry process. The novel thin-film Ag/AgCl reference electrode showed stable potentials in concentrated chloride solutions for a long period. The plasma-polymerized film is considered to play an important role as an interfacial design between the sensing electrode and the immobilized enzyme considering that the film is extremely thin, adheres well to the substrate (electrode) and has a highly cross-linked network structure and functional groups, such as amino groups. The results showed increments of the sensor signal, probably because the plasma-polymerized film allowed a large amount of enzyme to be immobilized. The greatest advantage is that the process can permit the mass production of high-quality biosensors at a low cost.

Biosensing Techniques↗

[Picture quality and film mammography. I. The physical parameters of the filming system (gradation, sensitivity, definition and granularity) and the effect of exposure geometry (author's transl)].

The physical parameters of three radiographic filming systems used for mammography were analysed (industrial film without screens, lo dose system (Dupont), industrial film with lo dose screens). Their effect on image quality was studied and the influence of the exposure geometry on sharpness and detail was investigated experimentally. Geometrical unsharpness so reduces the difference in definition between screenless industrial film and a film-screen combination that the total unsharpness at the centre of the breast parenchyma of an average breast becomes approximately the same. In particular, recognition of fine detail (microcalcification) is reduced by geometric unsharpness. Final grading of the three film systems is only possible after development of a concept of film quality which takes account of the parameters of the filming system and of exposlre geometry, together with physiological and practical requirements (paper II).

Absorptiometry, Photon↗

Female responsiveness to erotic films and the "ideal" erotic film from a feminine perspective.

Subjects were 20 volunteers randomly selected from all female undergraduate students attending a local university, who were 21 years of age or older, and living off campus. The stimuli consisted of seven films, of approximately 5 minutes duration each, which depicted various types of human sexual behavior. Themes included "romantic" heterosexual behavior, primarily genital heterosexual behavior, a mild, and an explicit form of group-sex behavior, a mild and explicit form of heterosexual sadomasochistic behavior, and male homosexuality. Subjects rated the degree of sexual arousal experienced for each film on a 50-point Likert scale. The order of presentation of the films for each subject was randomized, and all subjects participated individually with only a female experimenter present. Following the rating period, subjects completed the Sex Knowledge and Attitude Test (9). Finally, a structured interview was conducted to probe specific likes and dislikes with respect to the content of the films viewed. Results indicated that rank order ratings of the films, from most to least sexually stimulating, was: heterosexual, romantic; group-sex mild (two males and one female); heterosexual-genital; group-sex explicit (three males and three females); sadomasochism (mild); sadomasochism-explicit (forcing and brutal); and male homosexuality. One conclusion that the data led to was that females preferred and were significantly more sexually stimulated by films in which a male related to a female (even if the male was treating the female cruelly) than they were by homosexual stimuli involving two males together. Correlational data between the rating responses and the Sex Knowledge and Attitude Test yielded much information including significant negative correlations between ratings of both group-sex films and rejection of sexual myths. Also, significant positive correlations were found between rated degree of sexual stimulation for the heterosexual and the group-sex films and the consideration of pre- and extramarital relations as acceptable or even desirable.

Abortion, Spontaneous↗

Detection of simulated chest lesions: comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography.

PURPOSE: To compare a high-contrast asymmetric screen-film system with a conventional screen-film combination and storage phosphor radiographs for detection of simulated chest lesions. MATERIALS AND METHODS: To test the diagnostic performance of these three systems, the authors used three types of simulated lesions that were superimposed over the chests of 10 patients and an anthropomorphic phantom. In the patient and phantom study, a total of 1,350 observations by each of the eight radiologists were analyzed by means of receiver operating characteristics. RESULTS: In the patient study, mediastinal nodules were better visualized with high-contrast asymmetric screen-film and storage phosphor radiographs compared with the conventional screen-film system. For visualization of pulmonary nodules, the high-contrast asymmetric screen-film system was best. Micronodules were poorly visualized on high-contrast asymmetric screen-film and storage phosphor radiographs, but only in the phantom study. CONCLUSION: The high-contrast asymmetric screen-film system combines the advantages of conventional screen-film radiographs with improved visualization of the mediastinum.

Adult↗

Evaluating sol-gel ceramic thin films for metal implant applications. II. Adhesion and fatigue properties of zirconia films on Ti-6AI-4V.

The degree to which ceramic coatings or thin films applied to bone-interfacing metallic implants can improve the overall performance of these implants with respect to implant fixation, wear, or corrosion relies especially on the response of these films to loading. In this study, the adhesion and fatigue properties of sol-gel zirconia films that could be reproducibly deposited onto polished Ti-6AI-4V substrates was investigated. For zirconia films on the order of 100 nm thick, a shear lag-based strain approach indicated a shear adhesion strength of approximately 275 MPa. Small variations in film thickness and substrate surface preparation had little effect on this adhesion, which was believed to be due to alkoxide molecule interactions with free hydroxyl groups on the substrate surface as well as some limited interfacial diffusion following the 500 degrees C anneal. Subsequent fatigue testing of these films in air using novel tapered rotating beam fatigue samples demonstrated their excellent fatigue characteristics, with films surviving up to 10(7) cycles, the endurance limit of the Ti-6AI-4V (approximately 635 MPa). Overall, the exceptional mechanical properties of this ZrO2/Ti-6AI-4V system along with the inherent advantages of sol-gel processing support continued studies to utilize this technology for implant surface modification.

Alloys↗

Evaluating sol-gel ceramic thin films for metal implant applications: III. In vitro aging of sol-gel-derived zirconia films on Ti-6Al-4V.

Sol-gel-derived zirconia films were deposited onto polished Ti-6Al-4V substrates by dip-coating from an alkoxide precursor solution. No change in morphology of the zirconia film was observed after aging at 37 degrees C for 4-12 weeks in pH 4.0 buffer solution or Hanks' balanced salt solution (HBSS), although a precipitate predominantly composed of calcium phosphate was formed on those films aged in HBSS. X-ray diffraction identified the phase of the zirconia film as either cubic or tetragonal, and revealed no degradation to the monoclinic phase after aging. By a substrate straining test, the fracture strain of the coating was revealed to be 1.5%, above the yield strain of the titanium alloy substrate. At this strain level, through-thickness cracks formed in the coating where slip bands emerged from the substrate. Qualitatively, the adhesion of the film was sufficient to prevent gross delamination of the film at high strain levels, although small regions of delamination were caused by compressive buckling of the film. This behavior indicates generally good adhesion. No change in this behavior was observed after aging.

Alloys↗

Slow release of drug through deformed coating film: effects of morphology and drug diffusivity in the coating film.

The effects of the morphology and drug diffusivity in the coating film on the slow release characteristics have been analyzed numerically under the constraint that the volume of the coating film and the drug matrix is maintained constant. Two different systems of coated particles with deformed coating films were studied and their release characteristics compared with those of the coated particles having spherical coating films. The average release rate, fractional release, drug concentration profiles, and the initial burst of drug were found to be strongly influenced by the ratio of drug diffusivity in the coating film to that in the drug matrix D(r) (i.e., dimensionless drug diffusivity in the coating film). Increasing D(r) always increased the release rate, the fractional release, and the initial burst of drug, but reduced the initial lag times of drug release. The effect of shape deformation was very significant in the drug concentration profiles and the initial lag times; in contrast, it was not so substantial on the fractional release and the average release rates. The morphology difference in the deformed systems was also found to affect the release characteristics to different extents. Increasing the degree of the shape deformation, represented by the perturbation parameter epsilon, always reduced the effective surface area for the controlled release of drug. Because of the compensation effects between decreasing surface area and the non-uniform mass flux distribution, even though the heterogeneity of surface mass flux distribution would become more considerable, the effects of increasing shape deformation to the overall release rate would be less than expected unless the coating film was deformed significantly enough. The effect of the shape deformation and the morphology difference become less effective to differentiate the release characteristics with increasing D(r).

Delayed-Action Preparations↗

Lipid-protein surface films generated from membrane vesicles: selfassembly, composition, and film structure.

Lipid-protein films at the air-water interface were generated from a variety of native vesicles and from vesicles derived from lipid extracts. A technique is described which is particularly suitable for the generation of films from small amounts of material at high yield and velocity. In all instances, 10 microliters vesicle suspensions containing 25 micrograms protein yield at least 50 cm2 film area at a constant surface pressure of 12 mN/m within minutes. Upon formation, surface films are separated from vesicles by use of shear forces. Complete separation is demonstrated by electron microscopy and surface pressure-area diagrams. The latter confirms previous conclusions that surface films generated from lipid vesicles are organized as a monolayer. Analysis of lipid-protein surface layers reveals that their lipid to protein ratios match those of the vesicles used, within a factor of two, irrespective of whether films are generated at high or low surface pressure. Surface denaturation of membrane proteins is shown to be effectively prevented when the film is generated and held at high surface pressure (greater than or equal to 15 mN/m). Upon surface pressure jumps from high to low values, denaturation kinetics revealed activation areas of 1.5 (+/- 0.2) nm2.

Animals↗

Thin-film glucose biosensor based on plasma-polymerized film: simple design for mass production.

We propose a simple thin-film glucose biosensor based on a plasma-polymerized film. The film is deposited directly onto the substrate under dry conditions. The resulting films are extreme thin, adhere well onto the substrate (electrode), and have a highly cross-linked network structure and functional groups, such as amino groups, which enable a large amount of enzyme to be immobilized. Since this design allows fabrication through a dry process, with the exception of the enzyme immobilization, which is the last stage of the process, the chip fabrication can be designed as a full-wafer process to achieve mass production compatibility. The resulting sensors produced using this film are more reproducible, exhibit lower noise, and reduce the effect of interference to a greater degree than sensors made using conventional immobilization methods, e.g., via 3-(aminopropyl)triethoxysilane. The obtained film is a good interfacial design between enzyme and electrode; enzyme two-dimensionally locates very close to the electrode in a manner that is quite reproducible. Therefore, a wide dynamic range (up to 60 mM) and rapid response time (11.5+/-0.8 s) were obtained. Because of its highly cross-linking network structure, the amperometric response due to interferences such as ascorbic acid and acetaminophen was reduced by size discrimination of plasma-polymerized films.

Biosensing Techniques↗

Equivalent-circuit model for the thickness-shear mode resonator with a viscoelastic film near film resonance.

We derive a lumped-element, equivalent-circuit model for the thickness-shear mode (TSM) resonator with a viscoelastic film. This modified Butterworth-Van Dyke model includes in the motional branch a series LCR resonator, representing the quartz resonance, and a parallel LCR resonator, representing the film resonance. This model is valid in the vicinity of film resonance, which occurs when the acoustic phase shift across the film is an odd multiple of pi/2 rad. For low-loss films, this model accurately predicts the frequency changes and damping that arise at resonance and is a reasonable approximation away from resonance. Elements of the parallel LCR resonator are explicitly related to film properties and can be interpreted in terms of elastic energy storage and viscous power dissipation. The model leads to a simple graphical interpretation of the coupling between the quartz and film resonances and facilitates understanding of the resulting responses. These responses are compared with predictions from the transmission-line and Sauerbrey models.

Elasticity↗

Glass transitions and dynamics in thin polymer films: dielectric relaxation of thin films of polystyrene

The glass transition temperature T(g) and the temperature T(alpha) corresponding to the peak in the dielectric loss due to the alpha process have been simultaneously determined as functions of film thickness d through dielectric measurements for polystyrene thin films supported on glass substrate. The dielectric loss peaks have also been investigated as functions of frequency for a given temperature. A decrease in T(g) was observed with decreasing film thickness, while T(alpha) was found to remain almost constant for d>d(c) and to decrease drastically with decreasing d for d<d(c). Here, d(c) is a critical thickness dependent on molecular weight. The relaxation time tau(alpha) of the alpha process, which was measured as the frequency at which the dielectric loss realizes its peak value at a given temperature, was found to have a d dependence similar to that of T(alpha). The relaxation function for the alpha process was obtained by using the observed frequency dependence of the peak profile of the dielectric loss. The exponent beta(KWW), which was obtained from the relaxation functions, decreases as thickness decreases. This suggests that the distribution of relaxation times for the alpha process broadens with decreasing thickness. The thickness dependence of T(g) is directly related to the distribution of relaxation times for the alpha process, not to the relaxation time itself. The value of the thermal expansion coefficient normal to the film surface was found to increase with decreasing film thickness below T(g), but to decrease with decreasing film thickness above T(g). These experimental results are discussed in the context of a three-layer model in which within thin films there are three layers with different mobilities and glass transition temperatures.

Journal Article↗

The influence of chromatin compactness on the stoichiometry of the Feulgen-Schiff procedure studied in model films. II. Investigations on films containing condensed or swollen chicken erythrocyte nuclei.

As models for different states of chromatin compactness, nuclei from chicken erythrocytes were isolated and either osmotically swollen or kept as condensed as possible. Both types of nuclei were then fixed and incorporated into polyacrylamide films. Hydrolysis with 5 N HCl and staining with Schiff's reagent of these model films were studied using several parameters. The phosphate content of the films was analyzed as a parameter for the depolymerization losses and the staining with Schiff's reagent as a parameter for the apurinic acid (APA) content. The loss of ultraviolet absorbance from the films and the accumulation of ultraviolet absorbing substances in the hydrolyzing acid were monitored as parameters for the progress of hydrolysis. Conversion of the generated aldehyde groups to APA-Schiff chromophore is shown to take place with the same stoichiometry for both types of nuclei as well as for DNA in model films. It is further shown that the nuclei- and DNA-films are suitable models for investigating the influence of chromatin compactness on the course of the Feulgen-Schiff reaction. For the most compact form of chromatin studied, a very high reduction in staining intensity of up to 40% could be demonstrated after certain normally applied hydrolysis times. This is due primarily to a decrease with a factor of 2.3 of the depurination rate constants of these models (from 0.030/min to 0.013/min). Therefore prolonged hydrolysis periods are required to obtain the same APA concentrations, but then depolymerization processes cause losses of nuclear material. The differences in depurination rates could be explained by a decrease in [H3O]+ in the neighborhood of the purine-sugar linkages, caused by the presence of fixed positive charges form the protein components of the chromatin. These findings may explain the cytophotometrically determined differences in chromophore yield of 10-20% found in the nuclei of cells with different states of compactness of their chromatin. The descending part of the Feulgen hydrolysis curve represents the depolymerization of APA and loss by diffusion of the reaction products. In the Appendix, cytophotometric data of cells have been analyzed to show that this part of the hydrolysis curve may be used to estimate the acid stability of chromatin complexes. The depurination and depolymerization rates found closely correspond with the data obtained from the model films.

Animals↗

Film-based chest radiography: AMBER vs asymmetric screen-film systems.

OBJECTIVE: Contrast-to-noise ratios were measured on radiographs from two types of state-of-the-art chest imaging systems (an Advanced Multiple Beam Equalization Radiography [AMBER] system and an asymmetric screen-film system) to facilitate an objective comparison of image quality. MATERIALS AND METHODS: Radiographs of a chest phantom were obtained by using the AMBER system with a medium-latitude screen-film image recorder (Kodak T-MAT L film and Lanex regular screens) and a commercially available asymmetric, zero-crossover screen-film system optimized for chest radiography (Kodak InSight and InSight HC). Conventionally acquired radiographs (T-MAT L/Lanex regular) were also evaluated as a reference. Films were digitized, radiographic contrast and noise were measured in the lung-, mediastinum-, and subdiaphragm-equivalent regions of each image, and contrast-to-noise ratios were computed. RESULTS: Radiographic contrast and contrast-to-noise values were found to be higher on AMBER images in all chest regions when compared with radiographs obtained with the asymmetric screen-film systems (InSight contrast-to-noise ratio approximately 77% of AMBER contrast-to-noise in the lung-equivalent region, 57% in the mediastinum-equivalent region, and 43% in the subdiaphragm-equivalent region). On conventional radiographs, the contrast and contrast-to-noise values were higher than on all other image types in the lung-equivalent region and lower than on all other image types in the less well penetrated chest areas. CONCLUSION: Image quality was higher, most notably in dense phantom regions, on radiographs obtained with the AMBER system than on radiographs obtained with the new asymmetric screen-film systems. Clinical studies are needed to determine whether this level of image improvement justifies the additional expense of the exposure equalization system.

Humans↗

Corresponding dose response of radiographic film with layered gafchromic film.

This note investigates the dose response of layered HS Gafchromic film compared to Kodak EDR-2 radiographic film. Using five layers of HS type Gafchromic film a dose response greater than EDR-2 film is achieved at the peak wavelength (0.55 OD/Gy versus 0.3 OD/Gy for EDR-2 film). Even over a broader waveband of 30 nm, which is similar to that found in ultra bright LED scanners, the response was found to be 0.38 OD/Gy as opposed to 0.29 OD/Gy. Measurements averaged over the entire visible spectrum produce a relative dose response of 0.165 OD/Gy for five layer HS and 0.29 OD/Gy for EDR-2 film. Due to this high dose response that is achievable, the five layer HS could be used in applications where small doses are delivered to certain areas and a low dependence of energy response is required for measurement.

Dose-Response Relationship, Radiation↗

Evaluating sol-gel ceramic thin films for metal implant applications. I. Processing and structure of zirconia films on Ti-6AI-4V.

Thin ceramic films or coatings over metallic bone-interfacing implant surfaces have the potential to improve implant performance with respect to implant fixation, wear, or corrosion. In this study, zirconia (ZrO2) thin films formed on Ti-6AI-4V using a polymeric alkoxide-based solgel process were investigated. ZrO2 films of uniform thickness on the order of 100 nm were obtained by dip coating Ti-6AI-4V samples into a zirconium propoxide containing solution using a substrate withdrawal speed ranging from 2 to 8 cm/min and a sol of nominal viscosity approximately 6 cps. These films were essentially free of surface macrodefects but had random submicron "pinholes." X-ray diffraction studies suggested that the films were at least partially crystalline, with some "metastable" cubic and/or tetragonal phases after annealing for 1 h at 500 degrees C. The demonstrated reproducibility of this approach for producing good quality ZrO2 films on Ti-6AI-4V warrants further studies to optimize processing conditions for implant applications.

Alloys↗