Search PubMedSearch

SEARCH · Search PubMed

Results for “Error minimization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

185 records · Page 3Linked to original sources

Analyzing salinity tolerance in grass carp (Ctenopharyngodon idella): Insights from genome-wide association study and genomic selection.

Grass carp (Ctenopharyngodon idella) is one of the most widely cultured freshwater fish species globally. However, the expansion of its farming scale faces severe limitation owing to freshwater scarcity; therefore, the development of strains with greater salinity tolerance is key for expanding production using brackish water resources. To investigate the genetic basis of salinity tolerance in grass carp, a genome-wide association study (GWAS) was conducted using 200 individuals representing extreme phenotypes, namely salinity-tolerant and salinity-sensitive groups. In total, 17 single nucleotide polymorphisms (SNPs) related to salinity tolerance were detected, which were distributed across 11 chromosomes. Through gene annotation, 38 candidate genes were obtained from these loci. Enrichment analysis revealed these candidate genes are primarily implicated in key biological processes, including osmotic regulation, energy metabolism, and stress responses. Analyses of different SNP densities revealed that the 5 K SNP density panel can balance prediction accuracy and computational efficiency. The BayesA model achieved the highest prediction accuracy under the GWAS_Evenly selection strategy, with substantial reductions in mean absolute error and mean square error. This study reveals the genetic mechanisms of salinity tolerance in grass carp, which might be optimized through genomic selection, and provides insights for selectively breeding new varieties with greater salinity tolerance.

Animals

Patient-reported outcome measures for depression or anxiety symptoms in patients with cardiovascular disease: A COSMIN systematic review.

BACKGROUND: Depression and anxiety are common in patients with cardiovascular disease (CVD), but the measurement quality of patient-reported outcome measures (PROMs) used in this population remains unclear. This review aimed to evaluate the methodological quality, measurement properties, and certainty of evidence for depression and anxiety PROMs in adults with CVD and to inform instrument selection. METHODS: Following COSMIN and PRISMA guidance, four databases were searched from inception to February 2026. Studies assessing measurement properties of PROMs in adults with CVD were included. Methodological quality was evaluated using the COSMIN Risk of Bias checklist, and certainty of evidence was graded using an adapted GRADE approach. RESULTS: Sixty-six studies assessing 38 PROMs were included, comprising 29 generic and 9 CVD-specific instruments. Six PROMs met COSMIN Category A criteria: Cardiac Depression Scale-Short Form, Patient Health Questionnaire-9, Beck Depression Inventory-II, Hospital Anxiety and Depression Scale, Generalized Anxiety Disorder-7, and Major Depression Inventory. Four instruments were classified as Category C because of insufficient structural validity. Content-validity evidence was largely indeterminate or of limited certainty. Only 24 studies used confirmatory factor analysis or Rasch analysis, and no study assessed measurement error or responsiveness. Cross-cultural validity evidence was scarce. CONCLUSIONS: Six PROMs met Category A criteria, but selection should remain purpose- and context-specific. Particular attention should be given to somatic symptom overlap and intended clinical use. Further validation should prioritize content validity, measurement invariance, responsiveness, measurement error, and clinimetric performance.

Humans

Webcam-Based Real-Time Visual Feedback During Baduanjin Practice in Older Adults: 6-Week Pilot Randomized Study.

BACKGROUND: Baduanjin qigong is a traditional mind-body exercise used to support balance and physical health in older adults. Age-related changes in proprioception may make accurate self-directed performance difficult without external guidance. OBJECTIVE: The aim of this study is to explore whether webcam-based real-time visual feedback delivered during supervised laboratory sessions was associated with differences in webcam-derived 2D pose discrepancy and movement consistency during Baduanjin practice in older adults. METHODS: A total of 31 older adults were enrolled, and 28 participants with complete analyzable records were included in this complete-case dataset (feedback group, n=14; nonfeedback group, n=14). All sessions were conducted face-to-face in a supervised motion-analysis laboratory. Weekly 2D pose-discrepancy values were analyzed using a linear mixed-effects model with fixed effects for group, categorical week, and the group-by-week interaction and a participant-specific random intercept. Joint- and movement-specific participant-level 6-week means were analyzed exploratorily using Welch independent-samples t tests. Holm correction was applied across 24 exploratory contrasts (6 week-specific, 8 joint-specific, and 10 movement-specific comparisons), and Hedges g and 95% CIs were reported. Participant-specific weekly slopes and within-participant variability were additionally examined to directly assess longitudinal error drift. RESULTS: The linear mixed-effects model showed no significant group-by-week interaction (Wald χ25=1.09; P=.96) and no significant overall week effect (Wald χ25=6.40; P=.27). Averaged across 6 weeks, the feedback group had an estimated mean 2D pose discrepancy 1.20° lower than the nonfeedback group (95% CI -2.38° to -0.02°; P=.046), although this marginal pilot finding was sensitive to an analytic approach. No week-specific contrast remained significant after Holm adjustment. Nominal right elbow, right shoulder, and right knee differences did not survive global Holm correction. Form 3 showed a lower mean discrepancy in the feedback group (mean difference -3.70°, 95% CI -5.86° to -1.54°; Hedges g=-1.30; unadjusted P=.002; Holm-adjusted P=.04). Direct analyses of participant-specific slopes and within-participant SDs did not support a significant between-group difference in longitudinal error drift. CONCLUSIONS: In this small exploratory pilot study conducted under supervised laboratory conditions, the 6-week trajectories did not differ significantly between groups. A marginally lower average 2D pose discrepancy was observed in the feedback group across the 6 weeks, but no individual week- or joint-specific comparison remained significant after multiplicity adjustment. Form 3 was the only exploratory contrast that remained significant after global Holm correction. Direct longitudinal analyses did not demonstrate prevention of error drift. Larger studies using validated reference measurements, prespecified outcomes, and adequately powered longitudinal designs are required.

Humans

Not just when, but how: An exploratory dual-control approach to video feedback in motor learning.

The present study provides exploratory evidence for a novel dual-control paradigm. It examines whether combining temporal over video feedback timing with learner-controlled interactive playback functions (pause, slow-motion, rewind) would enhance motor skill acquisition beyond temporal autonomy alone. Sixty-four novice adults were randomly assigned to one of four conditions: Full Control (self-controlled timing + interactive replay), Partial Control (self-controlled timing + non-interactive replay), Yoked Full Control (externally controlled timing + interactive replay), or Yoked Partial Control (externally controlled timing + non-interactive replay). Motor accuracy (Radial Error), movement consistency (Bivariate Variable Error), technical execution, and self-efficacy were assessed at pre-test, 24-h retention, and 72-h retention following two acquisition sessions on a dart-throwing task (120 trials total). The Full Control group demonstrated the greatest and most durable learning gains across all outcomes. The Group × Time interaction was significant across all dependent variables (η2ₚ ranging from 0.140 to 0.234), with Full Control demonstrating superior retention at both 24 and 72 h relative to other groups (though differences relative to Partial Control were more pronounced at 72-h retention). Critically, the Yoked Full Control group showed comparatively weaker outcomes despite access to the same interactive playback functions. These findings suggest that interactive video tools may be most useful when learners can regulate both when feedback is accessed and how it is inspected. Theoretical and practical implications for the design of learner-centered video feedback systems are discussed.

Humans

Conserved host-exclusive oligonucleotide motifs enriched in pathogenic genes of human oncogenic viruses.

Comparative viral genomics can reveal sequence-level constraints influencing virus-host interactions. Relative minimal absent words (rMAWs) are short oligonucleotide motifs present in viral genomes but completely absent from the host, potentially reflecting selective pressures related to host adaptation and immune evasion. Using the EAGLE algorithm and the GRCh38 human reference genome, we systematically screened for prevalent rMAWs (prMAWs) across six major human oncogenic viruses: Epstein-Barr virus (EBV), hepatitis B virus (HBV), hepatitis C virus (HCV), human papillomavirus (HPV), human T-cell leukemia virus type 1 (HTLV-1), and human herpesvirus 8/Kaposi's sarcoma-associated herpesvirus (HHV-8/KSHV). highly conserved 11- and 12-bp prMAWs were identified in EBV, HBV, HTLV-1, and HHV-8/KSHV, with sequence prevalences ranging from 91.5% to 97.9%. Conversely, no short prMAWs were detected in HCV or HPV, likely reflecting differences in genome architecture, mutation rates, and long-term host adaptation to the human host. Importantly, the identified host-exclusive motifs exhibited non-random genomic distribution and were preferentially embedded within viral genes central to replication, persistence, immune modulation, and oncogenesis, including EBNA-1 (EBV), HBx (HBV), Tax-associated regions (HTLV-1), and lytic replication genes of HHV-8/KSHV. Notably, all detected prMAWs were enriched in GC nucleotides and exhibited marked CpG over-representation, suggesting sequence constraints associated with epigenetic regulation and viral persistence. Collectively, these highly conserved, host-exclusive signatures offer promising, candidates for sequence-directed approaches in the diagnosis, monitoring, and investigation of virus-associated cancers.

Humans

Improving insurance deduction identification: a hybrid artificial intelligence model using machine learning and expert systems.

PURPOSE: Financial challenges in healthcare systems worldwide, especially in low- and middle-income countries like Iran, have increased hospitals' reliance on insurance reimbursements. Unrecognized insurance deductions often cause severe financial shortages, making efficient deduction management crucial. This study aimed to design a hybrid intelligent system for identifying and predicting insurance deductions by combining machine learning and expert system frameworks. DESIGN/METHODOLOGY/APPROACH: A mixed-methods design was applied in four stages. First, a scoping review identified the causes and patterns of insurance deductions. Second, interviews with 15 insurance experts produced a validated checklist and a dataset from inpatient billing records. Third, using the CRISP-DM methodology, machine learning algorithms were developed and tested in SPSS Modeler alongside a fuzzy expert system developed in MATLAB. Finally, the model was validated using the holdout method. FINDINGS: Four categories of deduction drivers were identified: service provision, registration errors, document submission issues, and revenue conversion processes. The CHAID decision tree outperformed other algorithms with a 99% precision rate and the lowest Mean Absolute Error (9.43). A brief assessment of potential overfitting was conducted to ensure that the CHAID model's high accuracy was interpreted cautiously and supported by the validation results. The fuzzy expert system with validated rules was adaptable for deduction classification, especially for cases unsuitable for quantitative modeling. ORIGINALITY/VALUE: The hybrid model improves detection and prevention of deductions, offering actionable insights for hospital administrators, insurers, and policymakers. Its implementation can enhance hospital information systems, streamline claims processing, and optimize revenue management amid financial constraints.

Machine Learning

Gelified ethanol for percutaneous sclerotherapy of bone lesions: a systematic review of clinical applications and outcomes.

PURPOSE: To systematically review the available evidence on the feasibility, safety, and clinical effectiveness of percutaneous sclerotherapy using radiopaque gelified ethanol (RGE, Discogel®) for bone lesions. METHODS: A systematic search of MEDLINE, Embase, Web of Science, and Cochrane CENTRAL was performed. Primary studies reporting clinical, technical, and safety outcomes following RGE sclerotherapy for bone lesions were included. Data on patient characteristics, lesion type, procedural details, and outcomes were extracted and synthesized descriptively. RESULTS: Six retrospective studies involving 55 patients (mean age 22.2 ± 20.4 years; range 3-65; 26 females) with 56 lesions and 119 procedures were included (mean 2.16 procedures per patient). Aneurysmal bone cysts (80%) and aggressive vertebral hemangiomas (18%) were the main indications. Technical success was reported in 100% of procedures. Pain outcomes were available for 28 patients, with complete resolution in 64.3% (18/28), partial reduction in 32.1% (9/28), and persistence in 3.6% (1/28). Radiological follow-up (50 lesions) demonstrated complete response in 96% and partial response in 4%. No major adverse events were reported according to CIRSE (≥ 4) or CTCAE (≥ 4) criteria. One SIR grade 3 vertebral fracture occurred without confirmed causal association to RGE. Subsequent surgery was required in 3.6% of lesions. CONCLUSION: Although limited to small retrospective series, current evidence suggests that RGE sclerotherapy is a safe and effective minimally invasive option for selected benign bone lesions. Prospective comparative studies with longer follow-up are warranted.

Humans

The Impact of Video Game Experience on Surgical Performance: A Systematic Review.

OBJECTIVE: To assess whether video gaming experience is associated with improved surgical performance in the surgeon population across laparoscopic, robotic, and other surgical modalities, and evaluate its implications on surgical training and education. METHODS: A structured literature search was conducted across five databases on 29th November 2024 in adherence to PRISMA guidelines. Comparative studies evaluating surgical performance outcome data between surgeons with differing video game experience were eligible for inclusion. Outcomes evaluated were time to complete task, error rate, accuracy, economy of motion, and overall score. Included studies were assessed for risk of bias using ROBINS-I and RoB 2. RESULTS: 15 studies involving 641 participants were included, comprising one randomized controlled trial and 14 nonrandomized studies. All nonrandomized studies were judged to be at moderate or serious risk of bias, and the single randomized controlled trial was judged to be at serious risk of bias. Differences in study design and outcome measures meant that quantitative synthesis could not be performed. Across laparoscopic studies, video gaming experience was associated with improved overall score and time to task completion predominantly in the period prior to structured training interventions, with accuracy findings consistently favoring gamers in the two studies reporting this outcome. Error rate and economy of motion findings were inconsistent or predominantly nonsignificant. No meaningful association was identified across nonlaparoscopic modalities. CONCLUSIONS: Video gaming may be associated with improved surgical performance in surgeons, though this appears restricted to laparoscopic tasks and the pretraining intervention period. As a low-cost and accessible activity, video gaming may represent a practical informal adjunct to formal surgical training to help ease the transition into structured technical training. Surgical program directors need not alter existing selection criteria or training modules based on the available literature.

Video Games

Effect of protective ventilation throughout the intubation period on perioperative oxygenation in patients undergoing MIDCABG: a randomised controlled trial.

INTRODUCTION: Minimally invasive direct coronary artery bypass grafting (MIDCABG) requires prolonged one-lung ventilation (OLV), increasing postoperative pulmonary complications (PPCs) risk. We investigated whether protective lung ventilation (PLV) throughout intubation benefits MIDCABG patients. METHODS: In this single-center randomized study, MIDCABG patients received PLV (low tidal volume of 6-8&#x2009;mL&#xb7;kg-1, PEEP of 6&#x2009;cm H2O, alveolar recruitment maneuvers) or conventional mechanical ventilation (CMV, tidal volume of 8-10&#x2009;mL&#xb7;kg-1, without PEEP or maneuvers) from tracheal intubation to extubation. The primary outcome was perioperative oxygenation, assessed by the PaO2/FiO2 ratio. RESULTS: Sixty patients (n = 30 per group) were enrolled. Compared with CMV, PLV improved PaO2/FiO2 ratios (mean difference at OLV60: 34.56&#x2009;mmHg; 95% CI: 11.78-57.33; p&#x2009;<&#x2009;0.01), shortened median durations of postoperative mechanical ventilation (median difference: -4.5&#x2009;h, 95% CI: -8.5 to -0.5; p&#x2009;=&#x2009;0.013) and hospital stay (median difference: -3.0&#x2009;days, 95% CI: -5.0 to -1.0; p&#x2009;=&#x2009;0.019). PLV also reduced driving pressure, airway pressure and intrapulmonary shunt during OLV (all p&#x2009;<&#x2009;0.05). Desaturation occurred in 23.3% of CMV patients and 13.3% of PLV patients (p&#x2009;=&#x2009;0.506). Hemodynamic parameters were generally comparable between groups, except for lower MPAP and PVRI in the PLV group during OLV and after ICU admission (p&#x2009;<&#x2009;0.05). The incidence of PPCs did not differ between groups. CONCLUSIONS: In patients undergoing MIDCABG, PLV applied throughout intubation improved perioperative oxygenation and shortened the duration of postoperative mechanical ventilation and hospital stay, but did not reduce PPCs. CLINICAL TRIAL REGISTRATION: ChiCTR1900022005.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n&#x2009;=&#x2009;18) or conventional RP (n&#x2009;=&#x2009;22). Eligible patients were &#x2265;&#x2009;18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16&#xa0;min compared to conventional RP (38 vs. 54&#xa0;min, p&#x2009;=&#x2009;0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans

Clinical Efficacy and Learning Curve of Far-Lateral Approach (FLA) in Uni-Portal Non-Coaxial Spinal Endoscopic Surgery (UNSES) in the Treatment of Lumbar Degenerative Diseases: A Prospective Study.

BACKGROUND: Uniportal non-coaxial spinal endoscopic surgery (UNSES) via far-lateral approach (FLA) is an innovative minimally invasive procedure for lumbar degenerative diseases, particularly far-lateral disc herniation and foraminal stenosis. However, complex lateral lumbar anatomy and strict endoscope-instrument coordination create a distinct learning curve that may compromise early surgical efficiency and safety. This study aimed to evaluate the efficacy and safety, quantify the learning curve, and to provide clinical guidance for the standardized promotion and application of this technology. METHODS: A total of 40 consecutive patients with lumbar degenerative diseases who underwent UNSES via FLA by a single surgeon between January 2025 and December 2025 were included. All data were analyzed using SPSS 26.0 statistical software (IBM, USA). Primary outcomes included operation time, blood loss, fluoroscopy frequency, and intraoperative complication rate. Secondary outcomes were VAS, ODI, and modified Macnab criteria at 1, 3, and 6&#x2009;months postoperatively. The learning curve and the inflection point of the learning curve was determined using cumulative sum (CUSUM) analysis. The differences in clinical indicators between early and proficient stage were compared. RESULT: Operation time, blood loss, and fluoroscopy times decreased significantly with case accumulation (p&#x2009;<&#x2009;0.05). CUSUM identified an inflection point at the 16th case, after which operation time stabilized at (55.3&#x2009;&#xb1;&#x2009;8.6) min, much shorter than the early phase (89.5&#x2009;&#xb1;&#x2009;10.3) min (p&#x2009;<&#x2009;0.001). Before the 16th case, the curve was in an upward trend; after the 16th case, the curve tended to be flat, indicating the proficiency stage. Postoperative VAS and ODI improved significantly than those before surgery at each follow-up time (p&#x2009;<&#x2009;0.05). There was no significant difference in postoperative VAS score and ODI between the two groups at each follow-up time point (p&#x2009;>&#x2009;0.05). The total complication rate was 12.5% (5/40), were cured by conservative treatment. The total excellent-good rate was 90.0% (36/40). L5/S1 and Bertolotti's syndrome were independent factors affecting the learning curve. CONCLUSION: UNSES via FLA is a safe and effective minimally invasive technique for treating complex lumbar degenerative diseases. It has a certain learning curve, and the inflection point is about the 16th case. After mastering the key techniques such as anatomical positioning, endoscopic manipulation and hemostasis, the surgeon can gradually reach the proficiency stage, with significantly improved surgical efficiency and clinical efficacy, and controllable complications. This study provides a theoretical basis for the clinical training and technology promotion of UNSES via FLA.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Proficiency-based training and evidence-based methodology: a systematic review and meta-analysis.

OBJECTIVE: To assess adherence of self-labelled proficiency-based progression (PBP) studies to evidence-based PBP criteria and examine associations with training outcomes. METHODS: A systematic review and meta-analysis were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered in the International Prospective Register of Systematic Reviews. PubMed, CENTRAL, EMBASE, MEDLINE, and Scopus were searched from inception to 1 March 2023. Prospective English-language studies on healthcare procedural training reporting objective performance outcomes were included; non-prospective, non-quantitative, non-procedural, non-English studies, and reviews were excluded. Pre-specified outcomes included adherence to 18 evidence-based PBP criteria and objective performance metrics (errors, steps, time); secondary outcomes included proficiency benchmark achievement and Likert ratings. Data extraction was performed independently by multiple reviewers. Study quality was assessed using the Medical Education Research Study Quality Instrument and risk of bias by two investigators. Effect sizes were pooled using random-effects models (DerSimonian-Laird), expressed as the ratio of means (ROM) for continuous outcomes and bias-corrected odds ratios for dichotomous outcomes. RESULTS: Of 646 studies identified 175 met inclusion criteria. In the PBP studies (n&#x2009;=&#x2009;18), 94% fulfilled minimum criteria (use of a proficiency benchmark, its quantitative definition, and requirement for demonstration prior to progression) vs 36% of non-PBP studies (n&#x2009;=&#x2009;157). If all PBP criteria were included, 83% of PBP studies used these criteria vs only 2% of non-PBP-studies. In quantitative analysis (27 randomised clinical studies, 761 participants), ROM results showed that PBP training reduced the number of performance errors by 58% (P&#x2009;<&#x2009;0.001) and procedural time by 28% (P&#x2009;=&#x2009;0.006), increasing number of steps performed by 22% (P&#x2009;=&#x2009;0.03). When stratified based on number of criteria fulfilled, meta-regression demonstrated that increasing the number of PBP criteria fulfilled was associated with progressive and systematic trainee performance improvement. CONCLUSIONS: The more training methodologies adhere to established PBP criteria, the better training outcome will be.

Humans

F-URS with FANS versus mPCNL for 2-3&#x2009;cm UUTS: a RCT with a subgroup analysis of 2-2.5&#x2009;cm stones.

OBJECTIVE: To evaluate the safety and efficacy of flexible ureteroscopy (f-URS) with a flexible and navigable suction ureteral access sheath (FANS) compared with mini-percutaneous nephrolithotomy (mPCNL) in the treatment of 2-3&#x2009;cm upper urinary tract stones (UUTS), with a prespecified subgroup analysis for stones &#x2265;2 to <2.5&#x2009;cm. METHODS: This randomized controlled trial enrolled 326 patients with 2-3&#x2009;cm UUTS between June 2023 and December 2025. Patients were randomly assigned in a 1:1 ratio to undergo either f-URS with FANS or mPCNL. A prespecified subgroup analysis was conducted for stones measuring &#x2265;2 to <2.5&#x2009;cm. The primary outcomes were the immediate and 1-month stone-free rate (SFR). Secondary outcomes included the operative duration, decrease in haemoglobin, hospital stay, and complication rate. RESULTS: The baseline characteristics were comparable between the two groups. In the overall 2-3&#x2009;cm cohort, the FANS group achieved immediate and 1-month SFRs comparable to those of the mPCNL group. Although the operative time was longer in the FANS group, it was associated with significantly less haemoglobin loss and a shorter hospital stay, with no significant difference in infection-related complications. Notably, in the subgroup of stones &#x2265;2 to <2.5&#x2009;cm, the FANS group demonstrated a non-inferior SFR at both time points, and the operative time was not significantly longer than that of the mPCNL group. CONCLUSION: For 2-3&#x2009;cm UUTS, f-URS with FANS offers a SFR comparable to that of mPCNL, along with the advantages of reduced blood loss and shorter hospitalization. In the &#x2265;2 to <2.5&#x2009;cm subgroup, FANS shows comprehensive benefits over mPCNL. These findings support FANS as an effective alternative to mPCNL for 2-3&#x2009;cm stones and a potentially preferred option for stones measuring 2-2.5&#x2009;cm.

Humans

Robot-assisted bladder diverticulectomy in adults: a systematic review and pooled analysis of perioperative and functional outcomes.

Robot-assisted bladder diverticulectomy (RABD) is used for symptomatic acquired bladder diverticula, but evidence is dispersed across small single-centre series and the only dedicated systematic review dates from 2010. We reviewed contemporary perioperative and functional outcomes of RABD. Following a protocol registered on the Open Science Framework ( https://doi.org/10.17605/OSF.IO/54CFT ), PubMed, Embase, the Cochrane Library, Scopus and Web of Science were searched from inception to 30 August 2026 (initial search June 2026, re-run and broadened for this version), following PRISMA 2020. Eligible studies were original series of five or more adults undergoing robot-assisted bladder diverticulectomy reporting extractable outcomes. Two reviewers independently screened, extracted data and appraised risk of bias with the Joanna Briggs Institute checklist for case series, with third-reviewer adjudication. Binary outcomes were pooled as proportions with Wilson 95% confidence intervals (CI); continuous outcomes were summarised as patient-number-weighted descriptive values, because mixed median/mean reporting and clinical heterogeneity precluded a formal pooled-effect meta-analysis. Twelve studies (146 patients) were included and all outcomes were extracted from the full-text reports. A transperitoneal route was used throughout. There were no conversions to open surgery (0/129; 95% CI 0-2.9%). Major complications (Clavien-Dindo&#x2009;&#x2265;&#x2009;III) occurred in 3.0% (4/135; 95% CI 1.2-7.4%). Patient-number-weighted descriptive values (combining study-level medians and means, and therefore not a pooled mean) were: operative time 163 min, blood loss 99 mL, length of stay 3.6 days and catheter duration 7.7 days. Symptom scores and post-void residual improved in every reporting series, significantly in five. The single non-randomised comparison with open surgery reported fewer major complications after RABD (5% [1/20] vs. 50% [3/6], p&#x2009;=&#x2009;0.007), but the open arm comprised only six patients and this finding should not be regarded as comparative evidence. Across these series, RABD was feasible with low reported short-term morbidity in selected patients: no conversions to open surgery were recorded in the studies reporting conversion status, the major-complication rate was low, and symptom scores and post-void residual improved in every series that measured them. A minority of patients had an incidentally detected intradiverticular tumour; oncological outcomes were not an endpoint of this review. Evidence remains limited by small, heterogeneous, mostly retrospective series, so these findings should be read as descriptive; prospective comparative data are warranted.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans