Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Environmental monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Synthetic musks in environmental samples: indicator compounds with relevant properties for environmental monitoring.

Synthetic musks (nitro and polycyclic musks) are a group of chemicals offering a wide range of important properties for environmental monitoring programs. They are produced as odorous chemicals and added to a wide variety of perfumes, toiletry products and other household products. As such, they are directly applied in cosmetic products or in washed textiles to the human body in considerable concentrations and accumulate owing to dermal resorption. In addition, synthetic musks also enter the environment via waste water treatment. Several polycyclic musks are chiral. By using chiral gas chromatographic methods, it is possible to determine the enantiomeric ratio and assess their bioavailability. Although an comprehensive quality assurance program must be followed during the analysis of synthetic musks in environmental samples, the determination of these compounds is not very demanding and can be carried out by a standard analytical laboratory specialising in trace analysis of organic pollutants. Owing to the pheromone-like behavior of some synthetic musks, the induction of receptors in olfactory systems should be investigated. For HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta[g]-2-benzopyran, e.g., Galaxolide), three-dimensional structural similarities with androstenone (5 alpha-androst-16-en-3-one), a mammalian steroid pheromone, were found, which support the hypothesis of HHCB as an artificial pheromone. Owing to their environmental abundance, their relation to human activities and their potential for pheromone-like environmental behavior, synthetic musks are especially valuable as future indicator chemicals for environmental monitoring.

Air Pollution, Indoor↗

An approach to the assessment of the quality of environmental monitoring data.

This paper reports an approach to the assessment of the validity of environmental monitoring data--a 'data filter'. The strategy has been developed through the UK National Marine Analytical Quality Control (AQC) Scheme for application to data collected for the UK National Marine Monitoring Plan, although the principles described are applicable more widely. The proposed data filter is divided into three components: Part A, 'QA/QC'--an assessment of the laboratory's practices in Quality Assurance/Quality Control; Part B, 'fitness for purpose'--an evaluation of the standard of accuracy that can be demonstrated by activities in (A), in relation to the intended application of the data; and Part C, the overall assessment on which data will be accepted as usable or rejected as being of suspect quality. A pilot application of the proposed approach is reported. The approach described in this paper is intended to formalise the assessment of environmental monitoring data for fitness for a chosen purpose. The issues important to fitness for purpose are discussed and assigned a relative priority order on which to judge the reliability/usefulness of monitoring data.

Data Collection↗

Sublethal concentrations of mercury in river otters: monitoring environmental contamination.

Hair, muscle, and liver mercury concentrations were determined in river otter (Lutra canadensis) carcasses collected from the lower coastal plain and piedmont of Georgia. Mean muscle and hair mercury concentrations were greater (P < 0.001) in otters from the lower coastal plain (4.42 and 24.25 mg/kg wet wt, respectively) compared to otters from the piedmont (1.48 and 15.24 mg/kg, respectively). Liver tissue from lower coastal plain otters averaged 7.53 mg/kg mercury. Mean fetus brain and muscle mercury concentrations were 1.03 and 1.58 mg/kg wet wt, respectively, and fetal muscle mercury concentrations were correlated (r = 0.92) with maternal muscle mercury concentrations. Comparison of mercury concentrations found in Georgia otters to those associated with adverse effects in otter and mink (Mustela vison), indicate sublethal contamination with concentrations in some individuals approaching that observed in experimentally dosed individuals that developed clinical signs of mercurialism. Mercury concentrations in fish from the lower coastal plain approached or exceeded concentrations demonstrated to be toxic to experimentally dosed otters.

Animals↗

Comparative study on two freshwater invertebrates for monitoring environmental lead exposure.

Two freshwater invertebrate organisms, Biomphalaria glabrata and Lumbriculus variegatus, were tested as potential experimental animal models to assess Pb exposure using acute laboratory bioassays. Since long, the enzyme delta-aminolevulinic acid dehydratase (ALA-D) has been recognised as a useful biomarker of Pb exposure and effect. Therefore, determinations of ALA-D activity were performed in the whole body soft tissues of pigmented and non-pigmented gastropods B. glabrata and in the oligochaete L. variegatus. The organisms were exposed to varying concentrations of Pb for 48 h. Levels of Pb in the invertebrates were also analysed. Highly significant negative correlations were found between the enzymatic activity and the levels of Pb exposure, and also between the enzymatic activity and the metal incorporated by the invertebrates. No significant differences were found in the enzyme activity nor in the resulting metal accumulation based on gastropod pigmentation. The values of Pb concentration that produce 50% of inhibition on the enzyme activity (EIC50) were 0.023 and 0.029 mg Pb/L for pigmented and non-pigmented B. glabrata, respectively. A much higher value was found for L. variegatus (0.703 mg Pb/L). The non-observed effect concentration (NOEC) on enzyme activity for the oligochaetes was 0.05 mg Pb/L, about twice the EIC50 calculated for the gastropods. These data showed that both pigmented and non-pigmented B. glabata were much more sensitive organisms than the oligochaetes. The differences in enzyme inhibition could be attributed, at least partly, to differences in the metal body burden found between the organisms, since levels of Pb accumulated by B. glabrata were approximately three times higher compared to those observed in L. variegatus. Therefore B. glabrata showed to be a more suitable and reliable bioindicator organism for assessing Pb contamination in aquatic ecosystems, especially at low levels of metal exposure.

Animals↗

A beta spectrometer for monitoring environmental matrices.

In environmental matrices, pure beta emitters are often present with other beta-gamma emitters. This work describes a beta spectrometer that allows measurement of pure beta-emitter activities of about 10(-2) Bq. The detection system consists of a plastic scintillator surrounded in a 4 pi geometry by large anticoincidence NaI(Tl) scintillators. Solid, liquid, and gaseous samples can be analyzed, and no chemical separation is necessary. The system is particularly useful for 90Sr measurement.

Beta Particles↗

Use of Wild Rodents for Environmental Monitoring - Comparison of Rats in Bangkok and Rural Areas of Thailand.

There is a great deal of concern regarding the hazard potential of human exposure to toxic substances and carcinogens as well as infectious agents in the environment. For monitoring purposes fish are well established with regard to aquatic pollution. However, for the human environment, mammalian species might be considered more relevant. As the various types of rats are one of the most common animals sharing human habitants they are natural candidates. In the present study, numbers of such wild rats were trapped in the metropolis of Bangkok and country regions of Thailand for comparison of lesions in the liver and lung which might provide indicators of carcinogens or other hazardous agents in the environment. Glutathione S transferase P form positive foci could be detected in livers, comparable to the laboratory rat case, but without any significant link to site of capture. In contrast, fatty liver and inflammation/cirrhosis were significantly more frequent in animals from the metropolis. Parasite infection also tended to be more prevalent, along with leptospirosis. Inflammatory change was similarly found in the lungs but without any variation between the city and countryside groups. These results suggest that wild rats could be employed as monitors of environmental agents of toxicological significance.

Journal Article↗

Environmental monitoring of pesticides by immunoanalytical techniques: validation, current status, and future perspectives.

Reliable monitoring technology is an essential component of effective regulation and risk management of environmental contaminants such as pesticides. Most environmental monitoring and analysis is currently conducted using instrumental techniques such as gas-liquid chromatography (GLC) and liquid chromatography (LC). Immunoanalysis provides powerful monitoring techniques that have emerged in the last 3 decades. This paper shows they can deliver rapid, accurate, and relatively inexpensive analysis with high throughput and that have the capability to be field oriented. The technique is versatile in application and can be formatted to suit different purposes such as quantitative analysis or simple "yes/no" tests that are field-portable. While there is a range of opinion on the merits of immunoassays as an analytical tool for pesticides, we suggest that this technology is best considered as complementary to GLC and LC, extending the range of capability for field monitoring. Supporting this view, an increasing number of successful applications of immunoassays to monitoring have been reported in recent years. We also report here the implications of recent developments in the field of immunodiagnostics and their application to monitoring of environmental contaminants. We emphasise that, together with adequate validation by instrumental techniques, immunoassays provide monitoring services yielding realistic and comprehensive data for risk management, allowing decisions on appropriate action by various authorities to be made.

Animals↗

Integrating spatio-temporal information in environmental monitoring data--a visualization approach applied to moss data.

Large-scale environmental monitoring data being sparse and collected on irregular grids, which may differ from year to year, are difficult to analyse and present. The traditional techniques from statistics and Geographic Information Systems (GIS) may not be useful given the often relatively small sample size combined with varying sampling density. In this study, the freeware visualization package XmdvTool was used for integration and exploration of monitoring data from three surveys of terrestrial mosses. Data on contents of Cu, Ni, Pb, V and Zn in mosses within an area of 300x300 km in southern Sweden, sampled in 1985 (177 samples), 1990 (156 samples) and 1995 (188 samples), were integrated and visualized using parallel coordinate and scatterplot display techniques. Several interesting findings about multi-element composition of samples, as well as changing temporal trends in the relations of five metals were made during interactive visual discovery. Visualization techniques for high-dimensional data may have limitations considering, for example, number of variables, ranges of data values, and spatial scales. Nevertheless, interactive data manipulation tools encourage the process of visual exploration, and the unique way of integrating spatial, temporal and multi-element components of moss data provided visual insights that are not possible to gain with traditional analysis tools.

Bryophyta↗

Electrochemical sensors for environmental monitoring: design, development and applications.

The advancement in miniaturization and microfabrication technology has led to the development of sensitive and selective electrochemical devices for field-based and in situ environmental monitoring. Electrochemical sensing devices have a major impact upon the monitoring of priority pollutants by allowing the instrument to be taken to the sample (rather than the traditional way of bringing the sample to the laboratory). Such devices can perform automated chemical analyses in complex matrices and provide rapid, reliable and inexpensive measurements of a variety of inorganic and organic pollutants. Although not exhaustive due to the vast amounts of new and exciting electrochemical research, this review addresses many important advances in electrochemical sensor design and development for environmental monitoring purposes. Critical design factors and development issues including analytical improvements (e.g. detection limits), microfabrication and remote communication are presented. In addition, modern environmental applications will be discussed and future perspectives considered.

Biosensing Techniques↗

A portable Raman acoustic levitation spectroscopic system for the identification and environmental monitoring of algal cells.

We report the coupling of a portable Raman spectrometer to an acoustic levitation device to enable environmental monitoring and the potential taxonomic identification of microalgae. Spectra of living cells were recorded at 785 nm using a fiber-optic probe coupled to a portable Raman spectrometer. The spectra exhibit an excellent signal-to-noise ratio and clearly show bands from chlorophyll a and beta-carotene. Spectra of levitated photobleached microalgae clearly show a reduction in chlorophyll a concentration relative to beta-carotene after 10 min of exposure to a quartz halogen lamp. Spectra recorded from levitated nitrogen-limited cells also show a significant reduction in bands associated with chlorophyll a, as compared to nitrogen-replete cells. To investigate the diagnostic capability of the technique, four species of microalgae were analyzed. Good quality spectra of all four species were obtained showing varying ratios of beta-carotene to chlorophyll. The combination of an acoustic levitation device and a portable Raman spectrometer shows potential as a taxonomic and environmental monitoring tool with direct application to field studies in remote environments.

Chlorophyta↗

Training of environmental health officers in Anglophone west Africa: how adequate for environmental monitoring?

There is concern that the curriculum for training Environmental Health Officers (EHO) in Anglophone English speaking West Africa grossly lags behind the skills needed by sanitarians in the sub-region to cope with the challenge of environmental monitoring/control. This paper examines in detail the existing curriculum for the training of EHOs at the diploma and degree levels in the sub-region and observes that both curricula lack sufficient credit weight to impart the desired skills to perform the highly scientific task of environmental monitoring. Suggestions are made on ways and means of enhancing the professional education of EHOs in the sub-region. The paper contends that the situation places sanitarians in the sub-region at a serious academic handicap as many universities are reluctant to accept them for further studies in related fields.

Africa, Western↗

[Occupational exposure to antineoplastic drugs in a hospital setting: biological and environmental monitoring].

OBJECTIVE: To estimate the occupational exposure of hospital personnel handling antineoplastics drugs using a highly sensitive and specific analitycal method in biological and environmental samples. DESIGN: To develop analitycal methods for the biological and environmental monitoring of more than one substance. SETTING: Five departments of the Policlinico Sant'Orsola-Malpighi (Bologna, Italy) involved in the preparation and administration of antineoplastic drugs. PARTICIPANTS: 50 nurses handling antineoplastics drugs. MAIN OUTCOME MEASURES: Evaluation of the occupational exposure of hospital personnel handling and administering anticancer drug cocktails. RESULTS: 19 of 50 subjects were positive to biological monitoring. Three were positive for MTX only, 11 for CP only and 5 subjects were positive for both. Urinary MTX levels ranged from 0.3 to 2.0 ppb, CP ranged fom 0.06 to 10.0 ppb. Wipe tests showed a higher contamination on the hoods working tray (where drugs are prepared), suggesting that the organization layout can affect the surface contamination level. Samples from each department resulted positive for at least one of three drugs. CONCLUSIONS: The analytical methods developed allow sensitive and specific determination of indicators of internal and external dose. Biological monitoring is of primary importance for assessing the real espoxure of hospital personnel during the preparation and administration of the drugs. Environmental monitoring stresses the importance to observe the Guidelines for standard operating procedures and the importance of protective disposables to reduce exposure and the associated health risk.

Antineoplastic Agents↗

Environmental monitoring in the The Netherlands: past developments and future challenges.

During the past three decades environmental monitoring systems covering an immense variety of environmental problems emerged rapidly throughout the world. In The Netherlands the entire spectrum of monitoring systems is present. Their development is especially interesting because of the Dutch complex environmental landscape: a result of the combination of a natural setting with a high small-scale variation and an intense use of the available space by both industry and agriculture. This necessitates a well balanced environmental policy wherein monitoring of both environmental compartments and environmental policy itself plays an important role. In this article we focus on abiotic systems, whereby the development of monitoring will be related to that of environmental policy in general. Some general lines emerge: from quantity towards quality, from single pollutants towards environmentally harmful processes as a whole, and from a focus on human health and safety towards integrated environmental management. Because The Netherlands is a highly organized and highly educated society, reacting fast and flexible to new problems, this progression has happened quickly. However, still much remains to be desired and flexibility not necessarily guarantees optimal routes of development. Paramount is the development of sophisticated and robust monitoring systems that truly support integrated environmental management. This asks for clear objectives based on solid scientific insights.

Environment↗