Dose reduction of asparaginase under pharmacokinetic and pharmacodynamic control during induction therapy in children with acute lymphoblastic leukaemia.

The enzyme asparaginase is an important element in the therapy of acute lymphoblastic leukaemia (ALL). The usual asparaginase dose as prescribed in the ALL-BFM-86/90 treatment protocol for the therapy of ALL is 10,000 IU/m2 at 3 d intervals and had been developed on the basis of the E. coli asparaginase preparation Crasnitin from the Bayer company. Using the described schedule the E. coli asparaginase preparation from the Medac company shows significantly higher biological activity than the Bayer preparation. These findings prompted an attempt to reduce the dose of the Asparaginase medac under careful pharmacokinetic and pharmacodynamic monitoring. At the first step of dose reduction in ALL treatment protocol I, 11 children received 5000 IU/m2 of Asparaginase medac. Another 15 children were given 2500 IU/m2 of the enzyme at the second step of dose reduction. Prior to each asparaginase dose, blood samples were taken to determine amino acids and trough enzyme activity. Concurrent with the asparaginase monitoring, the coagulation parameters were measured. 96% of samples from the first step of dose reduction (5000 IU/m2 every third day) showed complete L-asparagine depletion (< 0.1 microM), the median trough enzyme activity was 265 IU/l. At the second step of dose reduction (2500 IU/m2) complete L-asparagine depletion was seen in 97% of samples, and the median trough enzyme activity was 102 IU/l. Cerebrospinal fluid (CSF) depletion was complete in all samples tested (11/11). We concluded that an Asparaginase medac dose reduced from the usual 10000 IU/m2 down to 5000 IU/ m2 or 2500 IU/m2, applied at 3 d intervals, was sufficient to achieve complete L-asparagine depletion in serum. Changes of the fibrinogen levels was significantly less pronounced in the group on 2500 IU.

Adolescent↗

Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature.

The two most frequently performed diagnostic X-ray examinations are those of the extremities and of the chest. Thus, dose reduction in the field of conventional skeletal and chest radiography is an important issue and there is a need to reduce man-made ionizing radiation. The large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide provides a significant reduction of radiation dose in skeletal and chest radiography compared with traditional imaging systems. This article describes the technical background and basic image quality parameters of this 43 x 43-cm digital system, and summarizes the available literature (years 2000-2003) concerning dose reduction in experimental and clinical studies. Due to its high detective quantum efficiency and dynamic range compared with traditional screen-film systems, a dose reduction of up to 50% is possible without loss of image quality.

Cesium↗

Relapse and rehospitalization during maintenance treatment of schizophrenia. The effects of dose reduction and family treatment.

BACKGROUND: Previous studies have examined dose reduction and family treatment in schizophrenia, but none has examined their interaction. This study assessed the impact of dose reduction of antipsychotic medication and family treatment on relapse and rehospitalization during maintenance treatment. METHODS: Subjects were 313 male and female outpatients at 5 centers with a DSM-III-R diagnosis of schizophrenia or schizoaffective disorder. In a 3 x 2 design, subjects were randomized to 1 of 3 medication strategies using fluphenazine decanoate under double-blind conditions: continuous moderate dose (standard) (12.5-50 mg every 2 weeks); continuous low dose (2.5-10 mg every 2 weeks); or targeted, early intervention (fluphenazine only when symptomatic). Subjects also were randomized to 1 of 2 family treatment strategies (supportive or applied). Supportive family management involved monthly group meetings. The more intensive applied family management involved monthly group meetings and home visits where communication and problem-solving skills were taught. Patients and families were treated and assessed for 2 years. RESULTS: Both continuous low-dose and targeted treatment increased use of rescue medication and relapse; only targeted treatment increased rehospitalization. This pattern was consistent across both family treatments; there were no differences between family treatments. CONCLUSIONS: These findings reaffirm the value of antipsychotic medication in preventing relapse and rehospitalization. The absence of family treatment differences may be because both conditions engaged families.

Adolescent↗

Radiation exposure in spiral computed tomography. Dose distribution and dose reduction.

RATIONALE AND OBJECTIVES: The authors investigate the dose distribution of spiral and conventional computed tomography (CT) with film densitometry and to present a new method of evaluating the possibility of dose savings with spiral CT. METHODS: Films were exposed in a cuboid polymethyl-methacrylate phantom in conventional and spiral scan technique. Axial density profiles were obtained by digitizing the films using a fluorescent light scanner. The ratio of the number of rotations in spiral CT to the number of slices in conventional CT was calculated. RESULTS: In spiral CT with a pitch of 2, the densities in all points were lower than those in corresponding points in spiral CT with a pitch of 1 and in conventional CT with slice distance equal to slice thickness. A pitch of 1.5 in spiral CT led to a dose reduction of 14% to 30% compared with conventional CT. CONCLUSIONS: Increasing the pitch in spiral CT leads to a reduction of both integral dose and absorbed doses within the examined body region. The reduction of the integral dose can be significant, especially in cases where slice overlapping is diagnostically advantageous.

Humans↗

Dose reduction by the use of erbium filtration in a general radiographic room.

The conventional aluminium filtration of a general purpose X-ray tube in a district general hospital was replaced by an erbium filter for a 2-month period. The resulting reduction in skin dose was measured for a number of examinations using thermoluminescent dosimetry. The change in effective dose equivalent was calculated from these measurements and compared with previous theoretical estimates. The use of the erbium filter had no effect on radiograph quality. It was concluded that the use of an erbium filter resulted in a worthwhile reduction in radiation dose, and was a cost-effective method of dose reduction.

Aluminum↗

Two-year trial of maintenance neuroleptic dose reduction in schizophrenic out-patients: predictors of relapse.

Low dose maintenance therapy has been proposed as a pharmacological strategy for reducing exposure to neuroleptic drugs in schizophrenia. However, reliable predictors of post-dose reduction relapse, which could guide clinicians in selecting patients suitable for this type of treatment, have not yet been determined. In this study, 41 schizophrenic out-patients were assigned, on the basis of their previously clinically determined dosages, to one of two reduced maintenance fluphenazine decanoate regimes (35 mg/4 wks. or 10 mg/4 wks.) and were assessed, subsequently, for a 2-year period. Demographic, clinical and treatment characteristics of relapsers (22 patients) and non-relapsers (18 patients) were compared using univariate and multivariate tests. Four parameters: age, course of illness, duration of illness and duration since last psychiatric hospitalization, suggested, in univariate tests, significant discrimination between relapsers and non-relapsers. Stepwise discriminant function analyses defined a highly significant function (p < .01) which included only 3 predictors of relapse. In order of importance, these predictors were: (1) a history of chronic psychosis (2) male sex, and (3) an illness of short duration. Parameters such as age, baseline rating scales scores, magnitude of dose reduction and baseline maintenance dose failed to improve the ability to discriminate between relapsers and non-relapsers. Implications of these findings for clinical practice are discussed.

Adult↗

Predictors of antipsychotic withdrawal or dose reduction in a randomized controlled trial of provider education.

OBJECTIVES: To evaluate the effects of an educational program to reduce antipsychotic use in nursing homes that had high use rates post-OBRA-87 and to identify factors that predicted antipsychotic withdrawal or 50% or greater dose reduction. DESIGN/SETTING: A randomized controlled trial (RCT) of the educational program (nursing home the unit of randomization and analysis) was conducted in 12 Tennessee nursing homes (6 education/6 control). Cohort analysis in baseline antipsychotic users identified factors predicting withdrawal or dose reduction. SUBJECTS: The RCT analysis included 1152 patients in the homes at baseline and 6 months. The cohort analysis included 133 baseline antipsychotic users in the five education homes able to implement the recommendations of the educational program. OUTCOME MEASURES: Change in days of antipsychotic use per 100 days of nursing home residence, withdrawal from antipsychotics, reduction in antipsychotic dose by 50% or more. RESULTS: Following the educational intervention, use of antipsychotics in the six education homes decreased from 25.3 days per 100 at baseline to 19.7 days per 100 by month 6, a 23% reduction relative to control homes (P = .014). In the withdrawal analysis, 44 (33%) of 133 baseline antipsychotic users were withdrawn. Factors at baseline predicting successful withdrawal were low antipsychotic dose, no use of benzodiazepines or antidepressants, and behavioral symptoms score below the median. However, although an additional 22 patients had dose reductions > or = 50%, none of the predictors of withdrawal were associated with dose reductions. CONCLUSIONS: Focused provider education programs may facilitate antipsychotic reduction above and beyond that attributable to regulatory changes. Patients who are poor candidates for total antipsychotic withdrawal may tolerate substantial dose reductions, which should reduce their risk of adverse antipsychotic effects.

Aged↗

Dose reduction to the thyroid gland in intraoral source radiography.

Organs near the oral cavity may be exposed to unacceptably high levels of radiation in intraoral source radiography. Three methods for reducing the dose to the thyroid gland have been investigated. A restriction of the exposure geometry by use of the B and C types of applicator was an efficient means of dose reduction. Absorbed doses to the thyroid gland were 30-50% less than those obtained when using the A-type applicator. A 10 degree upward inclination of the occlusal plane reduced the dose by 20%. In contrast, three thyroid protectors had no effect on dose reduction.

Absorption↗

Impact of ribavirin dose reductions in hepatitis C virus genotype 1 patients completing peginterferon alfa-2a/ribavirin treatment.

BACKGROUND & AIMS: To maximize sustained virologic response (SVR) in patients with chronic hepatitis C virus (HCV) infection, treatment with pegylated interferon and ribavirin has been genotype-specific (1 vs non-1). We evaluated the effects of ribavirin and peginterferon alfa-2a dose reductions on SVR in patients infected with HCV genotype 1. METHODS: Data were pooled from 569 patients enrolled in 2 phase III trials of 48 weeks of treatment with peginterferon alfa-2a and ribavirin. All patients were evaluated for the effect of cumulative drug exposure on 4- and 12-week responses, and the 427 patients who completed treatment were evaluated for effect of drug exposure on SVR. RESULTS: Of patients who completed treatment, more had reductions (< or =97% cumulative dose) of ribavirin than of peginterferon alfa-2a (43% vs 27%). Neither early virologic response nor SVR was affected adversely by ribavirin reductions when the cumulative ribavirin exposure was greater than 60%. The SVR was reduced significantly (P = .0006) in patients with less than the 60% cumulative ribavirin dose and was associated with prolonged periods of dose reduction, temporary interruptions, or premature cessation of ribavirin. Ribavirin dose reductions had minimal impact on SVR in patients who achieved rapid virologic response, defined as undetectable HCV RNA levels after 4 weeks, even when they received less than the 60% cumulative ribavirin dose. In contrast, SVR was reduced markedly in patients who had ribavirin dose reductions and did not achieve rapid virologic response. CONCLUSIONS: Minor ribavirin dose reductions to manage adverse events do not appear to affect SVR adversely, unless cumulative exposure is less than 60%. Prospective studies, however, are required to establish the impact of ribavirin dose reduction on SVR.

Adult↗

Factors contributing to ribavirin dose reduction due to anemia during interferon alfa2b and ribavirin combination therapy for chronic hepatitis C.

BACKGROUND: Recent studies indicate that combination therapy with ribavirin and interferon alfa2b (IFNAlpha2b) is effective for chronic hepatitis C virus (HCV) infection. However, reversible hemolytic anemia is a common side effect of this therapy. METHODS: We determined those factors that contribute to ribavirin dose reduction due to anemia during this treatment by using multiple logistic regression analysis in Japanese patients. The study included 123 patients with chronic hepatitis C (85 male, 38 female; mean age, 50 years; range, 20-70 years), who received 24-week combination therapy. All patients were treated with IFNAlpha2b daily for 2 weeks, followed by three times weekly dosing for 22 weeks, with oral ribavirin twice daily, at a total daily dose of 600 or 800 mg. RESULTS: Of the 123 patients, 34 patients required dose reduction of ribavirin, and 78 patients required no dose reduction. Overall, 20 patients discontinued. On univariate analysis, reduction of the ribavirin dose correlated significantly with pretreatment hemoglobin (Hb) levels of less than 14 g/dl, female sex, and patient age 55 years or older. On multivariate analysis, pretreatment Hb of less than 14 g/dl level and age 55 years or older were significantly associated with ribavirin dose reduction. The hazard ratios were 3.56 (95% confidence interval [CI], 1.48-8.53) for pretreatment Hb levels of less than 14 g/dl, and 2.50 (95% CI, 1.05-5.94) for age 55 years or more. CONCLUSIONS: Because patient age of 55 years or more, and Hb levels of less than 14 g/dl are significant factors that influence ribavirin-induced hemolytic anemia, more careful monitoring is necessary during combination therapy for patients with these risk factors.

Adult↗

Patient dose reduction by audit of grid usage in barium enemas.

Patient dose reduction may be achieved by removal of the antiscatter grid during fluoroscopy when fine detail is not required, such as during the filling phase of barium enemas. A questionnaire revealed that none of 22 trainee radiologists routinely removed the grid for the filling phase of adult barium enemas. Following this, 100 consecutive barium enemas were observed, with assessment of patient radiation dose by means of a dose-area product meter. The grid was removed in only six examinations. Phantom measurements implied a possible 46% reduction in dose for the filling phase by correct grid usage. These data were presented at a local clinical audit meeting, resulting in a change in departmental policy to recommend routine removal of the grid for the filling phase of barium enemas. In a follow-up audit the grid was removed in 96 of 100 consecutive enemas, resulting in a significant 46.5% dose reduction for the filling phase (95% confidence interval 38-61%). Further re-audit has demonstrated continued good practice.

Adult↗

Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield.

Shielding the radiosensitive gonads during X-ray exposure has been advocated for plain film radiography for many years. In the UK, gonad shields are not widely employed in routine CT scanning, possibly owing to a perceived difficulty in protecting the gonads from a multidirectional X-ray source. The increasing numbers of CT scanners in the UK, with the large doses they deliver to patients, make potential dose reduction methods an important issue. This study measures the dose reduction achievable by shielding the male gonads with a lead wrap-around protection device. The reductions in dose when shielded both from direct radiation and from indirect radiation scattered from local tissues were studied. The use of the device resulted in a statistically significant reduction in the absorbed testicular dose from both direct and scattered radiation, with no increase in the dose measured in surrounding tissues. In three clinically relevant experimental protocols where the testes were not irradiated directly, the testicular absorbed dose from indirect scatter was reduced by 77-93% of the corresponding non-shielded figure. In these three experiments, image quality was unaltered by the use of the shield. A larger dose reduction was obtained when the shield was used to protect the testes from direct irradiation. However, this was achieved at the expense of considerable image degradation from streak artefact that would effectively prevent the clinical use of the device in this setting.

Gonads↗

Experimental and clinical studies on dose reduction effects of spacers in interstitial brachytherapy for carcinoma of the mobile tongue.

The difference of radiation dose reduction effect with spacers of different materials, a heat-curing denture base resin and a silicon impression material, was examined experimentally and clinically. Radium needles and iridium hairpins were used as radioactive sources. In both studies, it was revealed that a dose reduction effect of silicon impression material was greater than that of denture base resin. Silicon impression material was thought to be a better material for spacers because of its larger radiation dose reduction effect and the time saving to produce the spacer.

Brachytherapy↗

[Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations].

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied by 2.7. A factor less than 2.7 means further dose reduction. Compared to the radiation exposure with a standard adult protocol, the effective dose in a pediatric thoracic MSCT could be reduced by up to 92 % in neonates, 89 % in toddlers and 80 % in school children. In abdominal MSCT, the effective dose could be reduced by up to 90 % in neonates, 89 % in toddlers and 83 % in school children. Using an adequate MSCT technique in children by adjusting the CT scanning parameters to the clinical question and body weight of the examined child enables a significant reduction of radiation exposure in comparison to standard MSCT protocols.

Body Weight↗

[Radiological technologists view about dose reduction techniques in interventional radiology].

We classified radiation exposure in interventional radiology into medical exposure and occupational exposure, and examined dose reduction and optimization from the point of view of radiological technologists. Radiologists and radiological technologists should share knowledge and information about dose reduction for patients and operators, and should maintain good relations and a good environment to further the management of dose reduction in clinical practice.

Humans↗

[Possibilities for dose reduction in coronal spiral CT of the mid-face area].

The radiation dose at the eye lens and the thyroid gland in spiral-CT-examinations is comparable to those known from conventional computed tomography. In view of an increasing artificial radiation exposure, it remains an important aim to achieve dose reduction with persistent adequate imaging quality. We determined the doses of the named organs in four different CT-examination protocols by use of phantom studies and in 45 patients. By reduction of tube current and tube voltage, organ doses can be reduced by half. This is achieved without a relevant loss in diagnostic precision as far as high-contrast structures are concerned. Compared to conventional CT-scanning, the dose reduction reached 75%. Taking into consideration the increasing insensitivity in the z-plane and the worsening of the section-sensitivity profile, a properly chosen increase in pitch may result in a significant dose reduction. CT-scanning of high-contrast structures in the head and neck can and should be performed with the least radiation exposure possible.

Craniofacial Abnormalities↗

Erbium filtration for dose reduction in dental radiography.

Previous work has suggested that rare-earth filtration of diagnostic X rays is an effective means of dose reduction in radiology. Erbium (atomic number 68) is particularly promising in this respect. The effects on the X-ray beam and surface dose of the addition of 0.1 mm of erbium foil to the conventional filtration of a GE1000 dental X-ray set were investigated. Filtration by 0.1 mm of erbium produced a beam of narrower spectrum, greater penetration but lower intensity than that filtered conventionally by aluminium alone. The overall dose reduction achieved in dental radiography was greater than 30% between 65 and 85 kVp with a maximum dose reduction of 42% at 65 kVp. The question of the cost-effectiveness of erbium filtration as a radiation protection measure is also addressed.

Erbium↗

Dose reduction in maxillofacial imaging using low dose Cone Beam CT.

OBJECTIVES: (a) To measure the absorbed dose at certain anatomical sites of a RANDO phantom and to estimate the effective dose in radiographic imaging of the jaws using low dose Cone Beam computed tomography (CBCT) and (b) to compare the absorbed and the effective doses between thyroid and cervical spine shielding and non-shielding techniques. STUDY DESIGN: Thermoluminescent dosimeters (TLD-100) were placed at 14 sites in a RANDO phantom, using a Cone Beam CT device (Newtom, Model QR-DVT 9000, Verona, Italy). Dosimetry was carried out applying two techniques: in the first, there was no shielding device used while in the second one, a shielding device (EUREKA!, TRIX) was applied for protection of the thyroid gland and the cervical spine. Effective dose was estimated according to ICRP(60) report (E(ICRP)). An additional estimation of the effective dose was accomplished including the doses of the salivary glands (E(SAL)). A Wilcoxon Signed Ranks Test was used for statistical analysis. RESULTS: In the non-shielding technique the absorbed doses ranged from 0.16 to 1.67 mGy, while 0.32 and 1.28 mGy were the doses to the thyroid and the cervical spine, respectively. The effective dose, E(ICRP), was 0.035 mSv and the E(SAL) was 0.064 mSv. In the shielding technique, the absorbed doses ranged from 0.09 to 1.64 mGy, while 0.18 and 0.95 mGy were the respective values for the thyroid and the cervical spine. The effective dose, E(ICRP), was 0.023 mSv and E(SAL) was 0.052 mSv. CONCLUSIONS: The use of CBCT for maxillofacial imaging results in a reduced absorbed and effective dose. The use of lead shielding leads to a further reduction of the absorbed doses of thyroid and cervical spine, as well as the effective dose.

Body Burden↗