Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compressive Strength”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

[Experimental research on the quantitative computed tomographic prediction of the compressive strength of the thoracolumbar vertebrae].

Testing 98 motion segments we investigated the possibility of a prediction of the compressive strength of thoracolumbar vertebrae by QCT. The ultimate compressive strength can be predicted from the density of the trabecular bone and from the size of the endplates--both determined by QCT--with an error of 1 kN. The increase of compressive strength in craniocaudal direction is calculated at approximately 0.3 kN per anatomical level. This variation is due to the increase of the endplate areas.

Adult↗

Preparation of calcium aluminate cement for hard tissue repair: effects of lithium fluoride and maleic acid on setting behavior, compressive strength, and biocompatibility.

We investigated lithium fluoride (LiF) and maleic acid (MA) containing calcium aluminate cement (CAC) for hard tissue repair. The objective of this study is to estimate the addition effects of LiF and MA on setting behavior, compressive strength, and biocompatibility of CAC and to find the most compatible composition of LiF and MA for using CAC as a new bone cement. The CAC was composed mainly of CaO. Al(2)O(3). Samples of LiF and MA containing CAC were formed along with recording of setting time and peak temperature and then set cement was analyzed by X-ray diffraction (XRD). Agar diffusion test, tetrazolium bromide (MTT) assay, and hemolysis test were used to detect initial in vitro biocompatibility of LiF and MA containing CAC. It was revealed from the results that LiF shortened setting time and decreased compressive strength, whereas MA delayed setting time and increased compressive strength. However, LiF and MA showed no or little influence on maximum temperature of CAC. CAC containing 0.5 g of LiF and 8.75 g of MA showed the highest compressive strength (111.64 +/- 7.74 MPa) across all the experimental compositions. The CACs containing 0.5 g of LiF/8.75 g of MA and 1.01 g LiF/8.75 g of MA had no cytotoxicity and hemolysis. In this study, CAC with 0.5 g of LiF and 8.75g of MA showed the most compatible properties for using bone cement, and thus it was assessed a candidate for a new bone cement along with CAC.

Aluminum Compounds↗

Surface detail, compressive strength, and dimensional accuracy of gypsum casts after repeated immersion in hypochlorite solution.

STATEMENT OF PROBLEM: One method used to disinfect a dental cast is immersion in a disinfecting solution. Repeated immersion of a cast in disinfectant may affect surface detail as well as other physical properties. PURPOSE: The purpose of this study was to evaluate the changes in surface detail quality, dimensional accuracy, and wet compressive strength of dental casts as a result of repeated disinfection in slurry containing 0.525% sodium hypochlorite solution. MATERIAL AND METHODS: Two different test specimen configurations were used, one for evaluating surface detail quality and dimensional accuracy and the other for compressive strength. Sixty specimens each were made of type III and type IV dental stone (Excalibur). Thirty specimens were immersed in slurry, a supernatant solution of calcium sulfate in distilled water (control casts), and 30 in slurry with sodium hypochlorite (test casts) solutions for 30 minutes and air dried for 24 hours. This process was repeated 7 times before testing. Linear dimensional change, surface detail quality, and wet compressive strength were determined according to American National Standards Institute/American Dental Association (ANSI/ADA) standards. The data were analyzed using 2-way analysis of variance and 2-sample independent t tests (alpha=.05). RESULTS: For specimens prepared with type III and type IV stone, treatment by immersion in slurry (control casts) and in slurry with sodium hypochlorite (test casts) resulted in an increase (P<.0001) in linear dimensional change. The type IV casts treated with slurry with sodium hypochlorite showed significantly less (P<.0001) mean linear dimensional change (0.025%) compared with type III stone casts (0.063%), and the values remained within the ANSI/ADA specified standards. Both test solutions caused some degree of erosion or damage to the surface quality of casts made from type III and type IV stones. However, the difference between the control and test casts was not significant. Slurry with 0.525% sodium hypochlorite solution decreased the compressive strength of both types of stones significantly (P<.001) compared with distilled water slurry. However, the values remained close to ANSI/ADA standards. CONCLUSION: The results demonstrated that repeated immersion of type III and type IV stone specimens in slurry with distilled water and slurry with 0.525% sodium hypochlorite, along with drying in air, caused a significant increase in linear dimension and a significant decrease in wet compressive strength. Although both the solutions caused some degree of damage to surface details for type III and type IV stones, the difference was not significant.

Calcium Sulfate↗

[Effects of the mode of ceramization on the compressive strength of Dicor crowns. A laboratory study].

The critical compressive strength of cast glass-ceramic samples with a standardised shape was evaluated as a function of the ceramization temperature. The maximum critical compressive stress was obtained under conditions prescribed by the manufacturer. After under- and overceramization by only 6 degrees C, as well as after repeated ceramization, the critical compressive strength was decreased significantly (p less than or equal to 0.05) by about 13-24%.

Ceramics↗

Compressive strengths of a new foil and porcelain-fused-to-metal crowns.

This study evaluated the compressive strengths of Renaissance foil and porcelain-fused-to-metal crowns on polycarbonate test dies. Both crown types were veneered with feldspathic porcelain. The compressive strength of the PFM crowns, 1895 +/- 317 N, was statistically higher than that of the Renaissance foil crowns, 1060 +/- 89 N. Comparison of the Renaissance foil crown's compressive strength to published biting forces indicated that the Renaissance crown should function without difficulty.

Crowns↗

The effects of mixing capsule geometry on the early compressive strength of dental amalgam.

Three dental amalgams were mixed in a number of different mixing capsules. Compressive strength specimens were prepared using a clinically relevant technique and tested at 1 h and 7 days. The results showed that the early compressive strength of an alloy was influenced by the mixing capsule, and suggested that internal capsule geometry may be an important contributory factor in capsule performance. With one exception, there was a marked difference between the compressive strengths produced under the present method and those reported by manufacturers under test conditions laid down in standards specifications.

Capsules↗

Prediction of thoracic and lumbar vertebral body compressive strength: correlations with bone mineral density and vertebral region.

The bone density of thoracolumbar vertebral columns (T1 to L5) from 18 individuals was measured using quantitative computed tomography and dual energy x-ray absorptiometry. Three hundred six isolated vertebral bodies were tested in a materials test device to determine their compressive strength. Between T1 and L5 the mean segmental increase in bone mineral content was 0.3 g, while the corresponding mean decrease in trabecular density was 4.7 HU. Midvertebral body cross-sectional area increased by an average of 46 mm2 per segment and the mean segmental increase in compressive strength was 0.17 kN. Compressive strength was significantly correlated with bone mineral density measured with dual energy x-ray absorptiometry (r = 0.86). Vertebral trabecular density samples measured with quantitative computed tomography were poorly correlated with compressive strength (r = 0.28); however, this was improved when the trabecular density was multiplied by the midvertebral body cross-sectional area (r = 0.83). This study provides information concerning the relationships between density and mechanical properties of all thoracic and lumbar vertebral bodies across a wide age range. While the load-bearing capacity of the vertebral bodies is largely dependent on their geometry and bone density, this relationship has been only extensively tested for the lumbar spine. This study extends these observations over the lumbar and thoracic regions to provide a comprehensive analysis of the strength characteristics of each vertebral body. This is particularly important given the paucity of data on the thoracic spine where age-related vertebral fractures predominate. These data provide a basis for the development of models to predict the potential for thoracolumbar fractures in the elderly vertebral column.

Absorptiometry, Photon↗

Compressive strength, fluoride release and recharge of fluoride-releasing materials.

The compressive strength, fluoride releases and recharge profiles of 15 commercial fluoride-releasing restorative materials have been studied. The materials include glass ionomers (Fuji IX, Ketac Molar, Ketac Silver, and Miracle Mix), resin-modified glass ionomers (Fuji II LC Improved, Photac-Fil, and Vitremer), compomers (Compoglass, Dyract AP, F2000, and Hytac) and composite resins (Ariston pHc, Solitaire, Surefil and Tetric Ceram). A negative linear correlation was found between the compressive strength and fluoride release (r(2)=0.7741), i.e., restorative materials with high fluoride release have lower mechanical properties. The fluoride-releasing ability can be partially regenerated or recharged by using a topical fluoride agent. In general, materials with higher initial fluoride release have higher recharge capability (r(2)=0.7088). Five equations have been used in curve fitting to describe the cumulative fluoride release from different materials. The equation [F](c)=[F](I)(1-e(-bt))+betat best describes the cumulative fluoride release for most glass ionomers, resin-modified glass ionomers, and some high fluoride-releasing compomers and composites, whereas [F](c)=[F](I)/(t(1/2)+t)+alphat best describes the cumulative fluoride release for most compomers and composite resins. The clinic applications of different fluoride-releasing materials have also been discussed.

Cariostatic Agents↗

Preparation and compressive strength of alpha-tricalcium phosphate/gelatin gel composite cement.

A novel alpha-tricalcium phosphate (TCP) and gelatin gel composite cement was prepared, and the effects of gelatin content, liquid/powder ratio, setting time, and additives (rod-like hydroxyapatite and CaTiO3 particles) on the microstructure and compressive strength of the setting product were investigated. Addition of gelatin gel to alpha-TCP cement resulted in the formation of a porous solid possessing pores of 20-100 microm in diameter whose pore diameter increased with increasing gelatin gel content. The compressive strength of alpha-TCP cement after 1 week increased from 9.0 to 14.1 MPa with increasing gelatin gel content up to 5 wt % and thereafter decreased. The compressive strength of the cement containing 5 wt % gelatin gel increased with time up to 35 MPa after 1 month whereas without gelatin gel it was approximately 20 MPa. Dispersion of 5 wt % of rod-like hydroxyapatite and CaTiO3 powders with alpha-TCP cement containing 5 wt % gelatin gel increased the compressive strength after 1 week from 14.1 to 31.3 and 34.8 MPa, respectively.

Bone Cements↗

Improvement of the mechanical properties of new calcium phosphate bone cements in the CaHPO4-alpha-Ca3(PO4)2 system: compressive strength and microstructural development.

The hardening properties of calcium phosphate cements in the CaHPO4-alpha-Ca3(PO4)2 (DCP-alpha-TCP) system have been investigated with interest focused on the compressive strength and microstructure development. Previous studies have shown that the addition of CaCO3(CC) leads to a modification of the calcium-deficient apatite structure of the reaction product, which results in a material more similar to the apatite in bone mineral. The addition of 10% w/w of CC to the initial DCP-alpha-TCP powder mixture resulted, with time, in a retardation of the development of compressive strength. However, the optimum compressive strength reached values up to 40% higher than CC-free samples. This retarding effect also has been monitored as a function of the calcium to phosphorus (Ca/P) ratio of the DCP and alpha-TCP mixture, showing the importance of the final cement properties of the relative quantities of the reactants in the mixture.

Bone Cements↗

Bone strength measurements at the proximal tibia. Penetration tests and epiphyseal compressive strength.

Three penetration tests were obtained from corresponding locations at each condyle of 19 proximal tibiae. The patterns of condylar cancellous bone strength varied little between knees. The medial condyle was the strongest with an average medial to lateral strength ratio of 1.9, and in most knees the medial condyle was strongest centrally while the lateral condyle was strongest posteriorly. The penetration strength at 5 successive 2 mm levels beneath the resected subchondral surface also showed a constant pattern of variation. Bone strength decreased significantly at first except at the posterolateral site, then tended to level off. The reduction of strength was most pronounced in the centre of the condyles. The penetration tests were good predictors of the static compressive strength of the proximal tibia. Correlation coefficients of approximately 0.90 were obtained indicating statistically highly significant correlations (p less than or equal to 0.00001). The tests were carried out with equipment developed for in vivo measurements of cancellous bone strength during total knee replacement. The findings confirm the close relationship of these investigations to conventional compression tests.

Aged↗

Compressive strength and heavy metal leaching behaviour of mortars containing spent catalyst.

This investigation was set and aimed to study the possibility of using spent catalyst as a concrete constituent which the spent catalyst was used as sand. Besides the spent catalyst was used as sand, it was also ground to very small particle size as small as that of cement and used as 20% replacement of cement by weight. Compressive strengths and leaching characteristics of lead, chromium, cadmium, and nickel in mortars containing spent catalyst and ground spent catalyst were tested. The results presented revealed that the compressive strength of mortar containing spent catalyst increased with ages. The results also indicated that the compressive strength of mortar containing spent catalyst at the proportion of 1.25 times of cement by weight was strong enough to make a concrete brick. In case of the ground spent catalyst being used to replace cement, it made the compressive strength lower than that of the standard mortar approximately 20%. The leachate results of lead and chromium from spent catalyst were lower than the allowance, but cadmium and nickel exceeded the limits. After the spent catalyst was fixed with cement, the leaching of the heavy metals did not exceed the industrial effluent standard. Therefore, the heavy metals mentioned earlier were not a problem in using spent catalyst as a concrete constituent.

Catalysis↗

Compressive strength, ash weight, and volume of vertebral trabecular bone in experimental fluorosis in pigs.

The aim of the investigation was to measure the effect of fluoride on vertebral trabecular bone compressive strength and to correlate this with fluoride-induced changes in bone density. This correlation would express changes in the quality of bone during fluoride treatment. Pigs were used in the experiment because their trabecular bone structure and remodeling sequences are very similar to the human. Eight animals receiving a supplement of 2 mg F-/kg b.w. per day from age 8-14 months were compared with 8 control animals. Morphologic measurements in the animals receiving fluoride supplement showed a significant increase of 17% in bone density and a smaller, insignificant increase of 3% in ash weight analyses. Meanwhile, the mechanical parameters for the fluorotic animals were unchanged (maximum compressive strength, maximum stiffness, and energy-absorption capacity) or decreased (normalized compressive strength = maximum compressive load corrected for ash density). It is concluded that the increased bone mass during the initial stages of fluoride treatment does not necessarily indicate an improved bone quality. The discrepancy between bone mass and strength could be either a permanent or a temporary phenomenon and requires further investigation.

Animals↗

Facial moulage: the effect of a retarder on compressive strength and working and setting times of irreversible hydrocolloid impression material.

STATEMENT OF PROBLEM: Irreversible hydrocolloid is widely used as an impression material for fabrication of extraoral maxillofacial impressions. A disadvantage of irreversible hydrocolloid, however, is its limited working time. PURPOSE: This study tested the compression strength (elastic recovery) and working and setting times for an irreversible hydrocolloid impression material after a retarder was added. MATERIAL AND METHODS: The irreversible hydrocolloid (Jeltrate) was mixed with water in a standard water/powder mixture of 18 mL (1 unit) of water and 7 g (1 unit) of the impression material. Test specimens (n = 3) were prepared by adding 2, 4, 6, and 8 drops of monobasic sodium phosphate (the retarder) to each. Three other specimens, to which no retarder was added, served as the control. Specimens were prepared according to the American National Standards Institute/American Dental Association's specification no.18 guidelines for irreversible hydrocolloid impression material. Immediately after the specimens were prepared, the flat end of a polished rod of poly(methyl methacrylate) was placed in contact with its exposed surface and quickly withdrawn. The working-time experiment was a pass/fail test conducted 30 seconds before the initial setting time. The initial setting time was established as extending from the start of the mix to the time when the impression material no longer adhered to the end of the rod. To determine how the compressive strength of the modified irreversible hydrocolloid (with retarder added) compared with that of the control, the mean stress at maximum load (Mpa) was analyzed. The compressive strength (MPa) was calculated. Statistical analysis consisted of descriptive statistics and regression analyses. RESULTS: The results of this experiment demonstrated that the elastic recovery of the irreversible hydrocolloid did not change with the addition of sodium phosphate (2 to 8 drops). The percent recovery with was 95.95% +/-.42%, 96.33% +/-.82%, and 96.28% +/-.53% for 0 (control), 2 and 8 drops, respectively. Average setting times for control specimens were 2 minutes 20 seconds +/- 0 seconds for the control specimen (0 drops) to 11 minutes 20 seconds +/- 1 minute 50 seconds for the test specimen with 8 drops. There was a direct relationship (R(2) = 0.85) between the number of drops added and the setting time. All control specimens and test specimens containing 2, 4, 6, and 8 drops of monobasic sodium phosphate produced acceptable levels of elastic recovery (> or =95%). CONCLUSION: Within the limitations of this study, predictable longer working and setting times were demonstrated for the irreversible hydrocolloid specimens with 1 to 8 drops of the sodium phosphate solution tested. The specimens with 8 drops of retarder solution exhibited variable setting times and would not be suitable for clinical use. The compressive strength of the modified irreversible hydrocolloid material tested was compromised because of the addition of sodium phosphate solution; however, recovery from deformation remained satisfactory as retarder solution was added.

Alginates↗

Effect of fitting adjustments on compressive strength of a new foil crown system.

The effect of die spacing and precementation internal adjustments on the compressive strength of a new ceramic foil crown system was examined in vitro. Twenty-four ceramic foil crowns were made for identical stylized master dies made of polycarbonate filled with 30 wt% carbon. One half of the stone working dies were coated with die spacer and the remaining were left untreated. A special foil used for these crowns was adapted to the working dies under 2500 psi loading. A sculpturing device was used to standardize the size and shape of the ceramic foil crowns. Only crowns made on dies coated with die spacer received precementation fitting adjustment. All crowns in the two groups were cemented with zinc phosphate cement and were subjected to compressive force until fracture occurred. Compressive strength data were analyzed and compared. Results showed that the use of die spacer and internal adjustments increased the compressive strength of the new ceramic foil crown.

Crowns↗

Examination of the test for compressive strength applied to zinc oxide eugenol cements.

The distribution of compressive strength results for a zinc oxide eugenol cement is negatively skewed. However, removal of a small number of outlying low results converts the distribution to a normal one. Crosshead speed and friction at the anvil have no significant effect on results, but compressive strength is a function of the diameter-length ratio of the cylinder and increases with this ratio.

Dental Stress Analysis↗

The effect of static torsion on the compressive strength of the spine: an in vitro analysis using a porcine spine model.

STUDY DESIGN: Matched porcine cervical spine motion segments were subjected to two main conditions and compared: axial compression and axial compression combined with varying axial torque. OBJECTIVES: To determine the effect of torsion on the acute compressive strength of the spine. SUMMARY OF BACKGROUND DATA: The spine is often subjected to compression together with axial torque as a component of complex loading, yet there is a lack of documentation on its effect on the compressive strength and injury mechanics. METHODS: Matched cohorts of porcine cervical spine (C5-C6) motion segments were compressed to failure at a rate of 3,000 N/s combined with 0 Nm, 5 Nm, 20 Nm, or 30 Nm of axial torque. Three "failure" points were recorded from the stress/strain association: the first "step" (initial microfracture), the initial slope change (yield point or "slow crush" mechanism), and the ultimate failure point (fracture). Furthermore, resultant injuries were documented using planar radiography and visual inspection following dissection of the motion segments. RESULTS: Axial torque affected the failure characteristics during acute compressive loading. The ultimate strength of the motion segments was significantly reduced with increasing static torques. The compressive load at which initial microfracture occurred, indicated by the first "step" in the load-deformation curve, was increased with 5 Nm, 10 Nm, and 20 Nm of applied torsion in comparison to no torque, but this effect was reduced with 30 Nm of torque. The "slow crush" mechanism of failure was not affected by the addition of axial torque. No radiographic gross injuries to the facet joints were observed. Damage appeared to be confined to the endplate and trabecular network of the vertebral body. CONCLUSIONS: Based on this animal model, shown to have similar biomechanical behavior to humans, axial torque appears to significantly reduce the compressive strength of the spine.

Animals↗

Effects of altered crystalline structure and increased initial compressive strength of calcium sulfate bone graft substitute pellets on new bone formation.

A new, modified calcium sulfate has been developed with a different crystalline structure and a compressive strength similar to many calcium phosphate materials, but with a resorption profile only slightly slower than conventional surgical-grade calcium sulfate. A canine bilateral defect model was used to compare restoration of defects treated with the modified calcium sulfate compared to treatment using conventional calcium sulfate pellets after 6, 13, and 26 weeks. The modified calcium sulfate pellets were as effective as conventional calcium sulfate pellets with regard to the area fraction and compressive strength of newly formed bone in the treated bone defects. Mechanical testing demonstrated that the initial compressive strength of the modified material was increased nearly three-fold compared to that of conventional surgical-grade calcium sulfate. This increase potentially allows for its use in a broader range of clinical applications, such as vertebral and subchondral defects.

Animals↗