Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compact Disks”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Principles of the highly ordered arrangement of metaphase I bivalents in spermatocytes of Agrodiaetus (Insecta, Lepidoptera).

We have investigated the nature of highly ordered bivalent arrangement in lepidopteran spermatocytes by analysing and comparing the patterns of bivalent distribution in intact metaphase I plates of 24 closely related species of the genus Agrodiaetus (Lycaenidae). The studied species greatly differed in haploid chromosome numbers (from n = 13 to n = 90) and in the structure of their karyotypes. We found that the larger the bivalent, the closer to the centre of the metaphase plate it was situated. In species with a high chromosome number and asymmetrical karyotype structure, the largest bivalent was located in the centre of the circular metaphase plate. Bivalents of equal size were approximately equidistant from the centre of the metaphase plate and formed concentric circles around the largest bivalent. These principles are diametrically different from those known in the majority of other animals and plants, in which the smallest elements of the chromosome set are situated in the centre of metaphase plate. The only exception from the above principles was observed in spermatocytes of A. surakovi which were heterozygous for reciprocal translocation involving two or three chromosome pairs. In addition to one large bivalent, the heterozygous cells had a multivalent, the size of which was comparable to or even exceeded that of the largest bivalentin the karyotype. In spite of thelarge size, the multivalent was always situated at the periphery of metaphase plate. This indicated that the chromosome size itself is not the only factor determining the bivalent position. We also found that the structure of the metaphase plate is fundamentally different in mitotic and meiotic cells of Agrodiaetus. In spermatogonial metaphase, chromosomes were tightly brought together, forming a dense compact disk, whereas during metaphase I of spermatocytes, all bivalents were clearly separated from each other, and the distance between adjacent bivalents varied from 0.4 to 1.5 microm. Based on the above findings, we proposed a model of bivalent distribution in the Lepidoptera. According to the model, during congregation in the prometaphase stage there is a centripetal movement of bivalents made by a force directed to the centre of the metaphase plate transverse to the spindle. This force is proportional to the kinetochore size of a particular bivalent. The Lepidoptera have a special near-holokinetic type of chromosome organisation. Therefore, large bivalents having large kinetochores are situated in the central part of metaphase plate. Another possible factor affecting the bivalent position is the interaction of bivalents with the cisternae of the membrane system compartmentalising the intraspindle space.

Animals↗

A comparison of the currency of secondary information sources in the biochemical literature. II. MEDLINE online and on CD-ROM.

The currency of selected versions of the MEDLINE database on CD-ROM and in online format was studied. The arrival of issues from 72 monthly journals and nine weekly titles during a 3-month period was monitored and their appearance in the various MEDLINE formats were recorded. Availability data for MEDLINE published by the National Library of Medicine were used as a baseline and subsequent distribution delays for the different MEDLINE formats were calculated. The study suggests a delay of approximately 2 weeks for indexing and mounting the MEDLINE file on to host computers for online access. A delay of 6-8 weeks was calculated for the MEDLINE data to be encoded on to compact disk, shipped and posted to the library customer. The currency of the MEDLINE database formats was compared with a weekly current-awareness service, CURRENT CONTENTS ON DISKETTE LIFE SCIENCES (CCOD). The majority of papers were indexed and distributed in CCOD within 10 weeks of publication date. Most papers appeared within 15 weeks in the online MEDLINE format and within 20 weeks in CD-ROM MEDLINE. The primary journal arrived at the library site within 5 weeks in most cases.

CD-ROM↗

[Speech audiometry with logatomes].

BACKGROUND: Logatomes are nonsense syllables used for analyzing the confusion of phonemes by hearing impaired listeners. They can provide a precise differentiation of phonemic confusions which may be useful in the exact adjustment of programmable hearing aids. METHODS: In this study, two lists of logatomes with 108 three-sound combinations with a structure of consonant-vowel-consonant (c-v-c) and vowel-consonant-vowel (v-c-v) were recorded on a compact disk. Twenty normally hearing adults and 28 patients with a sensorineural hearing loss were tested at a comfortable listening level of about 25 +/- 5 dB above the mean audiometric thresholds at 0,5. 1,0 and 2,0 kHz. An index of reduction of speech perception was calculated. RESULTS: A significant relationship between reduction of logatome perception and pure-tone audiometric thresholds at 1,2,3, and 4 kHz was demonstrated. Moreover, it was possible to distinguish between different groups of hearing impairment. CONCLUSIONS: The logatome test helps to analyze specific effects that hearing loss can have on the recognition of acoustic speech signals. The logatome test may become a valuable addition to speech audiometric tests with further standardization.

Adult↗

Cytochrome P450 database.

This paper describes a specialized database dedicated exclusively to the cytochrome P450 superfamily. The system provides the impression of superfamily's nomenclature and describes structure and function of different P450 enzymes. Information on P450-catalyzed reactions, substrate preferences, peculiarities of induction and inhibition is available through the database management system. Also the source genes and appropriate translated proteins can be retrieved together with corresponding literature references. Developed programming solution provides the flexible interface for browsing, searching, grouping and reporting the information. Local version of database manager and required data files are distributed on a compact disk. Besides, there is a network version of the software available on Internet. The network version implies the original mechanism, which is useful for the permanent online extension of the data scope.

Catalysis↗

A brief history of the Journal of Bone and Joint Surgery.

The Journal of Bone and Joint Surgery had its origins in the Transactions of the American Orthopedic Association, which first were published in 1889. In 1903, the Transactions of the American Orthopedic Association, Volume 16, became the first volume of the American Journal of Orthopedic Surgery, still under the sponsorship of the American Orthopedic Association. In 1919, the word American was dropped from the title and the Journal of Orthopaedic Surgery became the official publication of the newly formed British Orthopaedic Association and the American Orthopedic Association. The name was changed to The Journal of Bone and Joint Surgery in 1921. Shortly after the founding of the American Academy of Orthopaedic Surgeons in 1933, The Journal became the official organ of the academy; however, ownership of The Journal remained with the American Orthopaedic Association. The British volume appeared in 1948. The Journal of Bone and Joint Surgery became an independent, not-for-profit corporation in 1954. The Journal, which continues to be a leader in the area of orthopaedic publication, began publishing the full text on compact disk in January 1992, the full text in electronic form through BRS/Saunders in 1995, and the full text on The Journal's website in December 1999.

History, 19th Century↗

New perspectives in radioimmunoassay.

In addition to providing the basis of 'ultrasensitive' immunoassays, nonisotopic labels permit development of 'user friendly' methodologies, including simple devices designed for extralaboratory use and intended to provide yes/no answers to basic diagnostic questions, for example, the presence of an infectious disease, the commencement of pregnancy etc. Immunosensors are also intended to fulfil these objectives (albeit yielding quantitative information), but despite much research the prospect of adequately sensitive instruments of this type remains remote. Finally, nonisotopic labels enable the development of a new generation of miniaturized multianalyte assays permitting in principle the determination of entire analyte menus in small samples of body fluids. Such technologies will resemble those employed in compact disk recorders and other data-storage devices, differing only in that light emitted from discrete zones on a solid surface is fluorescent (or possibly chemiluminescent) rather than reflected, and yields chemical rather than physical information. The emergence of such technologies, will, inter alia, facilitate the screening of entire populations for infectious disease, endocrine dysfunctions, genetic abnormalities etc. using, for example, finger-tip blood samples, throat and endocervical swabs, and hopefully will contribute to the large-scale diagnosis and ultimate reduction of disease.

Humans↗

Bladder injury during laparoscopic surgery.

The objective of this review is to present the incidence of latrogenic bladder injury associated with diagnostic and/or operative laparoscopic surgery; to determine the type of primary laparoscopic operation, the time at which the reported injuries occurred, the location of injuries, and the method(s) used to repair those injuries; to decide which laparoscopic procedure carries the highest risk for bladder injury; and to establish the most frequent surgical instruments with which injuries happened. World literature published between 1970 and 1996 was reviewed. The appropriate Medical Subject Heading (MeSH) terms were selected and used in a search of the MEDLINE, ACOGNET, OVID Compact Disk Version database. A total of 1372 articles on laparoscopic surgery complications were reviewed. Of that number, a total of 77 articles identified bladder injuries, and these were analyzed for the objectives of this study. There are a wide range of bladder injuries during laparoscopic procedures. In the studied articles, the incidence of bladder injury during laparoscopic procedures ranged from 0.02 to 8.3 percent of cases. Most frequently, these injuries occurred during laparoscopic-assisted vaginal hysterectomy. Sharp electrosurgical dissection was the leading instrument causing injury. An intraoperative diagnosis of bladder injury was made in 53.24 percent of all bladder injury cases. The bladder dome was the most commonly injured structure. Less than half (29.87 percent) of the bladder injuries were corrected laparoscopically.

Female↗

Dynamic three-dimensional spiral computed tomographic cysto-urethrography: a novel technique for evaluating post-traumatic posterior urethral defects.

OBJECTIVE: To present a new method of identifying the anatomy of posterior urethral distraction defects (PUDDs) using three-dimensional spiral computed tomography/cysto-urethrography (CTCUG), as conventional two-dimensional CUG can give a false interpretation of the exact anatomy. PATIENTS AND METHODS: Twenty-one patients presenting with a PUDD were assessed between February 2001 and October 2002. All patients initially underwent combined ascending and micturating CUG (ACUG), followed by CTCUG analysed using special software. In this technique all soft-tissue densities were subtracted from the volume of interest leaving only high-density images, i.e. pelvic bony structure and the contrast medium-filled bladder and urethra. The images were taken over a sequence and 36 different images viewed by 'roll and spin' techniques, each of which had a different plane of vision. Images were supplied as static CT films and as a movie on a compact disk using a computer program. RESULTS: The technique allows one CT image to be viewed from 36 different angles both dynamically and statically, allowing the surgeon the unique opportunity to view the PUDD through several planes and precisely identify its anatomy. By comparing the data obtained with this technique to those obtained by conventional ACUG, and each in relation to the operative findings, the following aspects could be more thoroughly evaluated by CTCUG: the location of the distraction injury, the length of the distraction defect, the degree and direction of urethral end-alignment, the relation of the ectopic bony fragments and bone callus to the urethra, and the presence of various pathological defects, e.g. fistulae, false passages and diverticulae. CONCLUSION: With CTCUG, both static and dynamic images can be obtained, allowing the easier staging of a PUDD and thus better surgical planning and consequently better results from reconstruction.

Adult↗

Acoustic detection of manatee vocalizations.

The West Indian manatee (trichechus manatus latirostris) has become endangered partly because of a growing number of collisions with boats. A system to warn boaters of the presence of manatees, that can signal to boaters that manatees are present in the immediate vicinity, could potentially reduce these boat collisions. In order to identify the presence of manatees, acoustic methods are employed. Within this paper, three different detection algorithms are used to detect the calls of the West Indian manatee. The detection systems are tested in the laboratory using simulated manatee vocalizations from an audio compact disk. The detection method that provides the best overall performance is able to correctly identify approximately 96% of the manatee vocalizations. However, the system also results in a false alarm rate of approximately 16%. The results of this work may ultimately lead to the development of a manatee warning system that can warn boaters of the presence of manatees.

Algorithms↗

Computerized scientific exhibit in radiology: a valuable format for delivering scientific information.

The computerized scientific exhibit (CSE) is gaining acceptance as a tool for delivering scientific information at meetings of radiologic societies. CSEs allow presentation of more material in a more space-efficient manner than do conventional exhibits, and the viewer can control the order and detail in which material is reviewed. As a disadvantage, currently, the radiologist must use a support team and learn new tools to create a CSE. The preparation and cost may also be greater. Meeting attendees must overcome a reluctance to use computers to benefit from a CSE. Creation of a CSE has design, production, and presentation phases. A team of content authors, software author, graphics acquisition person, and project manager works together through brainstorming, conceptual ordering, storyboarding, prototyping, and selection of authoring tools to design the exhibit. Production must include use of common word processing and image file formats, as well as standardization of image resolution. Accurate equipment specification is needed to ensure that the exhibit can be run on the equipment provided by the meeting organizers. In addition, some security steps are needed to prevent misuse of the exhibit. In addition to display at assemblies, the CSE can be made available to a larger audience by delivery on media such as compact disks and the Internet and can be continually modified as new material becomes available.

Computers↗

A low-cost CD-ROM--based image archival system.

Many radiologists have large collections of original or copied radiographs, as well as 35-mm slides of radiographs that require conventional carousel-type projectors for display. These images cannot be digitally manipulated or displayed in other formats. The authors used compact disk, read-only memory (CD-ROM) technology as a low-cost method of digitally storing these images. The CD-ROM disks were created from slide images optically scanned and digitally transferred to a disk. The images may be incorporated into any type of computer application, used on multiple computer platforms, and are easily transportable. The process is a low-cost, high-quality method of transferring images to digital media and is currently available to anyone with a conventional 35-mm camera, a CD-ROM reader, and a computer.

CD-ROM↗

Computer-aided design and modeling of workstations and radiology reading rooms for the new millennium.

Three-dimensional (3D) computer modeling, simulation, and rendering techniques were used to redesign the diagnostic workstations and radiology reading rooms for a proposed hospital with particular attention given to lighting conditions, noise reduction, and optimal use of limited workspace. The results were presented to a panel of multidisciplinary experts and iteratively improved and redesigned with the development or addition of new design criteria or requirements. These 3D techniques allowed faster, more efficient design and presentation of multiple options than is possible with traditional two-dimensional drawings, thereby expediting decision making and resulting in significant savings. The current workstation designs can easily be developed and implemented with available technology at a reasonable cost. They can also accommodate anticipated advances in computer and display technology as well as new imaging paradigms (eg, changes in keyboard and control ergonomics such as adjustable virtual keys on touch-sensitive screens, digital drawing tablets for annotations and controls, direct film digitizing, personal identification devices, offline media readers such as compact disks and digital videodisks, and speech recognition and voice activation). Use of 3D techniques in designing other parts of the radiology department (eg, examination rooms, technologists' areas, physicians' offices) could greatly improve and facilitate the design and implementation of complex settings in these work areas.

Computer Simulation↗

Hypermedia techniques for diagnostic imaging instruction: videodisk echocardiography encyclopedia.

Because of the visual complexity of medical images and the intensive tutorial experience required to develop image recognition expertise, professional training programs have concentrated on educating limited numbers of experts. Videodisk and CD-ROM (compact disk read only memory) image storage media now make it possible for a microcomputer workstation to provide a learning environment substantially equivalent to that of conventional time-consuming tutorial methods. A demonstration hypermedia program on echocardiography was constructed that provides a user-controlled learning environment with instant access to 54,000 video frames encompassing 1,200 clinical items. The instructional module is controlled by a microcomputer, which provides electronic linkage to relevant graphics, animations, text, categorized data bases, and digitized sound. The system has been successfully used in a residency program as the primary instructional tool for achieving an intermediate level of clinical expertise. Hypermedia offer substantial advantages over conventional books as a clinical reference source.

Computer-Assisted Instruction↗

Integration of a multimedia teaching and reference database in a PACS environment.

In one radiology department, a computerized authoring and editing environment was developed and integrated with the picture archiving and communication systems (PACS) for creation of image-based electronic teaching files to replace a collection of printed film images. This multimedia database and authoring environment allows physicians to create reference databases for teaching and research directly from clinical cases being reviewed on PACS diagnostic workstations. The database engine allows users to generate stand-alone CD-ROMs (compact disks, read-only memory) and World Wide Web-based teaching files. The system is fully compliant with the Digital Imaging and Communications in Medicine (DICOM) standard and supports a large number of standard multimedia image file formats. The focus of the development was on convenience and ease of use of a generic system adaptable to all users. The software was integrated on the PACS workstations to allow users to add new cases to the database at any time and anywhere in the department. A pilot system was implemented in clinical operation, with a central server and several client units.

CD-ROM↗

Integrating the healthcare enterprise: a primer. Part 6: the fellowship of IHE: year 4 additions and extensions.

Recently, one of my friends, a computer wizard, paid me a visit. As we were talking, I mentioned that I had recently installed a picture archiving and communication system and a radiology information system. I told him how happy I was with the system and showed him a compact disk (CD) from it. To my surprise, he threw it into my microwave oven and turned it on. Instantly I got very upset, because the System had become precious to me, but he said, "Do not worry, it is unharmed." After a few minutes, he took the CD out, gave it to me and said, "Take a close look at it." To my surprise, the CD was quite cold to hold and it seemed to be heavier than before. At first, I could not see anything, but on the inner edge of the central hole, I saw an inscription, an inscription finer than anything I had ever seen before. The inscription shone piercingly bright, and yet remote, as if out of a great depth: 12413AEB2ED4FA5E6F7D78E78BEDE8209450920F923A40Eel0E50CC98D444AA08E324. "I cannot understand the fiery letters," I said in a timid voice. "No, but I can," he said. "The letters are Hex, of an ancient mode, but the language is that of DICOM, which I shall not utter here. But in common English, this is what it says: Two integration profiles to schedule work flow. Five for radiology with room to grow. One for the bacon to bring it home. One for HIPAA all alone. And one for results for those who would know. One technical framework in which to find them. One technical framework to guide them. One technical framework to bring them all. And in the Connect-a-thon bind them. In the Land of Lincoln where no shadows are. We continue the saga of the fellowship of the IHE: clinicians, radiologists, informaticians, administrators, technologists, imaging system vendors, and non-imaging system vendors, as they begin their year 4 transactions.

Computer Communication Networks↗

Comparison and evaluation of nine bibliographic databases concerning adverse drug reactions.

Few evaluations and statistical comparisons of bibliographic databases have been published. As a drug information center, we were particularly interested in databases providing references on adverse drug reactions (ADRs). Ten drugs were randomly chosen from the 2000 files at our center. Nine databases were selected according to the high frequency of references concerning ADRs: eight online systems (MEDLINE, BIOSIS, TOXLINE, Iowa Drug Information System, PASCAL, EMBASE, PHARMLINE, and International Pharmaceutical Abstracts [IPA]), and one Compact Disk Read Only Memory (CD-ROM) system (Core MEDLINE). The total number of references, the number of references from 1987 to 1989, and the number of relevant references from 1987 to 1989 were analyzed using the Friedman two-way ANOVA by ranks. The overlap between databases for only one drug, carboplatin, and the quality:cost ratio were also studied. Considering the total number of references, TOXLINE and EMBASE were significantly superior to IPA, PHARMLINE, PASCAL, and Core MEDLINE. For the period 1987-1989, EMBASE was significantly superior to PASCAL, IPA, PHARMLINE, and Core MEDLINE with regard to total number of references, and significantly superior to PASCAL, Core MEDLINE, and IPA with regard to relevance. MEDLINE, TOXLINE, and EMBASE had the best quality:cost ratio. EMBASE had the slightest overlap of references, with 53 percent of the unique references on carboplatin. This comparative evaluation showed that the ability of bibliographic databases to provide information on ADRs is dependent on both the size and the quality of each database.

Databases, Bibliographic↗

Developing an AIDS prevention intervention for incarcerated male adolescents in Brazil.

The objective of this study was to investigate knowledge, attitudes, and practices regarding AIDS among incarcerated male adolescents in Brazil and to develop an AIDS prevention intervention for this population. A questionnaire administered to 275 boys in São Paulo covered demographic and social characteristics, drugs, and HIV risk perception and behavior. Subsequently, we collected qualitative data on the development and implementation of a prevention program. Ninety-eight percent of adolescents were sexually experienced, most initiating by age 13; 22% were fathers. Injection drug use was reported by 5.5%, 12% had exchanged sex for money, 35% had more than 15 partners and 8% had homosexual experience. Although 72% had used condoms, only 9% used them consistently, and only 35% used one in their last intercourse before incarceration. Predictors of condom use included carrying condoms and endorsing the statement "I would use condoms with my girlfriend." Many said their lives include other risks more important than AIDS, such as survival in the crime scene. Initial efforts at prevention based on commonly used approaches of providing information to guide future rational decisions generated limited participation. However, when we worked with them to develop interventions based on their interests and needs, using modalities such as music, hip-hop arts, graffiti, and helping them to create an AIDS prevention compact disk, they responded with enthusiasm. These incarcerated adolescents are at extremely high social risk and report high levels of risk behavior for HIV infection. Interventions for these youth were better received when developed in collaboration with them and based on their beliefs, aspirations, and culture. The intervention that resulted went beyond AIDS to include issues such as violence, drugs, sexuality and human rights.

Adolescent↗

Developing regional workplace health and hazard surveillance in the Americas.

An objective of the Workers' Health Program at the Pan American Health Organization (PAHO) is to strengthen surveillance in workers' health in the Region of the Americas in order to implement prevention and control strategies. To date, four phases of projects have been organized to develop multinational workplace health and hazard surveillance in the Region. Phase 1 was a workshop held in 1999 in Washington, D.C., for the purpose of developing a methodology for identifying and prioritizing the top three occupational sentinel health events to be incorporated into the surveillance systems in the Region. Three surveillance protocols were developed, one each for fatal occupational injuries, pesticide poisoning, and low back pain, which were identified in the workshop as the most important occupational health problems. Phase 2 comprised projects to disseminate the findings and recommendations of the Washington Workshop, including publications, pilot projects, software development, electronic communication, and meetings. Phase 3 was a sub-regional meeting in 2000 in Rosario, Argentina, to follow up on the progress in carrying out the recommendations of the Washington workshop and to create a Virtual Regional Center for Latin America that could coordinate the efforts of member countries. Currently phase 4 includes a number of projects to achieve the objectives of this Center, such as pilot projects, capacity building, editing a compact disk, analyzing legal systems and intervention strategies, software training, and developing an internet course on surveillance. By documenting the joint efforts made to initiate and develop Regional multinational surveillance of occupational injuries and diseases in the Americas, this paper aims to provide experience and guidance for others wishing to initiate and develop regional multinational surveillance for other diseases or in other regions.

Accidents, Occupational↗