Search PubMedSearch

SEARCH · Search PubMed

Results for “Coated Materials, Biocompatible”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

206 records · Page 3Linked to original sources

Reversed unidirectional transport in a Janus polyurethane/alginate dressing for directional postbiotic delivery to infected wounds.

Probiotic-derived postbiotics exhibit significant potential for infected wound control; however, their effective and localized delivery at wound sites remains a challenge. This study developed a polyurethane/alginate composite nonwoven via electrospinning to establish a postbiotic delivery platform for Bifidobacterium bifidum BD-1 (PU/Alg/BD-1). The beaded fibrous hydrophobic PU layer and hydrophilic Alg layer form a wettability gradient, enabling reversed unidirectional fluid transport toward the wound interface while inhibiting backflow. In vitro results showed that PU/Alg/BD-1 exhibited significant antibacterial activity against Staphylococcus aureus and Escherichia coli and good cytocompatibility with a hemolysis rate of <5%. Targeted metabolomic analysis revealed multiple organic acids in the BD-1 metabolites, which contributed to its antibacterial activity. In vivo microbial analysis verified that PU/Alg/BD-1 effectively reduced the relative abundance of Staphylococcus at the wound site while increasing the proportions of Corynebacterium and Psychrobacter. This microbial modulation contributed to infection control in a rat full-thickness infected wound model, accompanied by a shift in the macrophage phenotype and the downregulation of inflammatory factors including IL-6, TNF-&#x3b1;, and TGF-&#x3b2; in the PU/Alg/BD-1 group. Compared with the blank control, conventional gauze, PU/Alg, and BD-1 groups, PU/Alg/BD-1 significantly promoted wound contraction and re-epithelialization and enhanced collagen deposition. Hence, this study provides an effective material construction strategy for the application of probiotic-derived postbiotics to promote wound healing, demonstrates the potential of BD-1 to regulate the wound microenvironment and accelerate healing, and thereby offers a novel approach for the treatment of infected wounds.

Journal Article

Degradation of a graphene-reinforced polyamide by fungi: When culture conditions matter.

The large-scale production, marketing and disposal of polymer-based graphene products can lead to the dispersal of graphene-enriched plastic particles into terrestrial ecosystems, where they might accumulate if not degraded by organisms. The objective of this work is to test the degradability and compatibility of one polyamide-6 polymer reinforced with reduced graphene-oxide (PA6-rGO) and its base constituents (polyamide-6, PA6; reduced graphene oxide, rGO) using mono- and co-cultures of two lignin-degrading fungi (Bjerkandera adusta and Morchella esculenta) grown under different nutrient conditions. Fungal (co-)cultures were exposed to pure rGO or abraded powders of PA6 and PA6-rGO in two different liquid media, and monitored over time for biomass growth, H2O2 production, and activity of two lignolytic enzymes (i.e., Laccase, Lac, and Lignin peroxidase, LiP). The changes in polyamide structure were evaluated by proton nuclear magnetic resonance and mass spectrometry, and changes in rGO were evaluated by Raman spectroscopy. The materials had no effect on fungal growth. PA6 increased Lac secretion only in low nutrient medium, while PA6-rGO slightly suppressed LiP activity. Only M. esculenta promoted polyamides oxidation when cultured in a low nutrient medium, as evidenced by a change in mass distribution values (m/z: 400-420) and the appearance of a new resonance peak (at 5.37 ppm). Lignolytic exudates in co-cultures low in nutrients caused a greater change in rGO, as shown by the increase in the ID/IG ratio. The degradation of rGO, PA6 and PA6-rGO depended on culture conditions.

Graphite

Morphology-Encoded Colorimetric Hydrogen Sensing Using Embedded Reactive Pd Absorbers in Fabry-Perot Cavities.

Chemical reactions offer a powerful strategy for generating visible optical responses through localized changes in absorption, dielectric environment, and interfacial wetting. A palladium (Pd)-embedded Fabry-Perot cavity is introduced as a reaction-active optical platform in which structural color is governed by intracavity absorption coupled with reaction-induced dielectric perturbation. Positioning Pd within the dielectric spacer creates a spatially controllable reactive absorber whose vertical location relative to the standing-wave field dictates wavelength-selective absorption within the cavity. The morphology of the embedded Pd layer provides an additional design parameter by modulating both optical loss and interfacial wetting. Under hydrogen exposure in the presence of oxygen, catalytic water formation at the Pd/polymer interface generates localized dielectric heterogeneity and interfacial water droplets, thereby perturbing the optical path length and amplifying the visible response. As a result, the cavity exhibits pronounced, morphology-dependent color transitions that are inaccessible through dielectric-layer engineering or Pd/PdH refractive-index changes alone, enabling direct visual hydrogen sensing under ambient light, as well as flexible optical devices capable of large-area patterning. These findings establish a design framework for reaction-active optical cavities that translate localized chemistry into a colorimetric hydrogen sensing mechanism.

Fabry&#x2013;Perot resonator

Are there any common effects in preclinical models of micro- and nanoplastic (MNP) exposure? A systematic review.

Micro- and nanoplastics (MNPs) are emerging contaminants detected in food sources and the marine food chain, raising concerns about human health. Although no causal relationship has been established between MNP exposure and specific diseases, growing evidence suggests adverse developmental, behavioral, cognitive and biochemical effects. This systematic review synthesized evidence from common preclinical neurotoxicology models, including C. elegans, D. rerio, D. melanogaster, in vitro systems and rodents, to identify convergent developmental, behavioral and biochemical outcomes. The protocol was preregistered in OSF, followed PRISMA-P guidelines, applied PICOS criteria, and assessed methodological quality using the European Commission's ToxRTool. Overall, 185 studies were included. Consistent findings showed impaired survival and disrupted development across all models. Behavioral alterations affecting anxiety, memory, learning, sociability and locomotor activity were also consistently reported. In addition, numerous studies identified disruptions in the serotonergic (5-HT) system, including changes in neurotransmitter levels, transporters and metabolic enzymes. Despite methodological heterogeneity, these findings indicate that MNP exposure produces reproducible neurodevelopmental and neurochemical alterations across experimental models. Future studies should improve methodological harmonization, strengthen cross-model comparability and identify robust biomarkers and key mechanisms underlying MNP-induced neurotoxicity, facilitating translation to human health risk assessment frameworks.

Animals

Biomimetic mesoporous silica nanosphere ameliorate experimental autoimmune uveitis by delivering sCD83.

Autoimmune uveitis (AU) is an autoimmune disease that may lead to blindness, but there are currently no precise targeted therapies for its prevention and treatment. Dendritic cell (DC) is key cell involved in the pathogenesis of AU, and specific regulation of their state can help improve AU. In this work, mesoporous silica nanospheres were loaded with the immunomodulator soluble CD83 (sCD83) and subsequently camouflaged with dendritic cell (DC) membranes to fabricate the nanocarrier DCM@MSN/sCD83 for treating experimental autoimmune uveitis (EAU). Research results show that DCM@MSN/sCD83 effectively alleviated the symptoms of uveitis in EAU, reduced the proportion of CD4+CD25-T cell/CD4+CD25+T cell and the percentage of DC in the eyes and cervical lymph nodes. It also decreased the expression of STING in M&#xfc;ller cell. Furthermore, the efficacy of DCM@MSN/sCD83 was found to be primarily targeting DC, and promoted the expression of IL-10 and TGF-&#x3b2;1 in DC by activating the phosphorylated HIF/STAT3 pathway, to induce the production of CD4+CD25+ T. This effect is superior to nanomedicine loaded with dexamethasone. Moreover&#xff0c;DCM enabled the nanocarriers to efficiently cross the blood-eye barrier and reach cervical lymph nodes, thereby regulating peripheral immunity. This research indicate that cell membrane-modified nanoparticles targeting homologous cells can effectively improve treatment efficiency and duration, which is potential therapy strategy for uveitis.

Animals

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Effectiveness of an educational video for caregivers of children with neurogenic bladder: A randomized controlled trial.

BACKGROUND: The complexity of neurogenic bladder (NGB) management underscores the importance of caregiver education, yet high-quality education materials remain scarce. This study aims to assess the effectiveness and acceptability of an educational video designed to improve knowledge about NGB among caregivers of children with this condition. METHODS: We identified English-speaking caregivers of patients aged zero to 18 years, diagnosed with NGB, without prior major bladder reconstructive surgery, who received care at our institution from 2018 to 2022. Caregivers were randomly assigned into control or video groups using a block randomization model based on age. The control arm completed a six-item knowledge assessment before viewing the video, while the video group watched the video first. All participants rated the video's acceptability. Qualitative analysis of the open-ended responses to the acceptability questionnaire followed principles of thematic analysis. RESULTS: Of 409 eligible participants, 106 (25.9%) completed the study. Video (n = 48) and control (n = 58) groups were demographically similar. In the video group, 64.6% answered correctly all questions in the knowledge questionnaire, compared to 31% in the control group. After adjusting for patient age, caregivers in the video group were more likely to answer any question in the knowledge assessment correctly (relative probability: 1.13, 95% CI [1.06, 1.21], p < 0.01). Evidence for a difference in correct response rate among individual questions was strongest for question #1, which asked about common urological conditions for which NGB patients are at higher risk (95.8% vs. 79.3%, p = 0.01), and question #6, which asked about indications for bladder surgery (87.5% vs. 67.2%, p = 0.01), with the video group more likely to answer correctly for both questions. Qualitative analysis identified three major themes regarding parents' acceptance of the educational video: 1) attitudes towards video content and presentation, 2) usefulness of video as an educational tool, and 3) future directions. CONCLUSIONS: Our study found that an educational video about NGB effectively enhanced parental understanding of the condition and was deemed acceptable by parents as an introductory educational tool. The literature shows the benefit of using technology and visual aids to enhance health literacy for patients and caregivers, a key first step towards optimizing health outcomes for pediatric urologic patients.

Humans

Diagnostic utility of high-risk HPV polymerase chain reaction-based testing in head and neck FNA specimens with indeterminate cytomorphology.

BACKGROUND: Fine-needle aspiration (FNA) is critical in the initial diagnosis of many high-risk human papillomavirus (HR-HPV)-associated, metastatic oropharyngeal squamous cell carcinomas. Updated guidelines recommend HR-HPV-specific polymerase chain reaction (PCR) analysis over p16 immunohistochemistry on FNA specimens because p16 performs poorly on cytology material. PCR-based assays on liquid cytology material have demonstrated excellent analytic performance; however, the diagnostic utility of a positive HR-HPV PCR result in specimens with indeterminate cytomorphology remains uncharacterized. METHODS: The authors retrospectively identified 279 head and neck FNA specimens that had paired HR-HPV PCR testing on residual liquid cytology material over a 5-year period. The positive predictive value for histopathologically confirmed squamous cell carcinoma on surgical follow-up was calculated within each cytologic interpretive category. RESULTS: The HR-HPV PCR results were positive in 50.2% of specimens, negative in 40.9%, and indeterminate in 9.0%. The HR-HPV positivity rate ranged from 0% in specimens categorized as negative for malignancy to 57.3% in cytologically positive specimens, with 19.0%, 41.2%, and 50.0% positivity in the atypical, suspicious, and nondiagnostic categories, respectively. Among cytologically indeterminate specimens with positive HR-HPV PCR results (n&#xa0;=&#xa0;14), the positive predictive value was 100% (95% confidence interval, 78.5%-100.0%). Blinded slide review additionally identified 15 cytologically positive specimens in which the definitive malignant interpretation depended substantially on HR-HPV positivity; all 15 were confirmed as squamous cell carcinoma. CONCLUSIONS: A positive HR-HPV PCR result on liquid cytology material carries a positive predictive value of 100% for malignancy in cytologically indeterminate head&#xa0;and neck FNA specimens. These findings support integrating HR-HPV PCR analysis into routine cytologic interpretation with the potential to upgrade some indeterminate specimens to malignant when HR-HPV is detected, expediting definitive treatment and sparing patients additional, invasive sampling.

Humans

Outcomes and Associated Prognostic Factors for Orthograde Canal Obturation Using Ortho MTA III: A Randomised Prospective Clinical Trial.

AIM: To prospectively compare treatment outcomes for orthograde canal obturation using Ortho MTA III (OMTA) with the continuous wave of compaction (CWC) using gutta-percha (GP) and AH Plus sealer, and to identify associated predictive factors. METHODOLOGY: Informed consent was obtained (110 patients), and single- or two-rooted permanent teeth (n&#x2009;=&#x2009;120) diagnosed with pulp necrosis (or previously treated) and asymptomatic apical periodontitis or chronic apical abscess (periapical index, PAI&#x2009;&#x2265;&#x2009;3) were randomly assigned to two groups (n&#x2009;=&#x2009;60/group). The canals were prepared to a minimal apical size #40 (ISO) based on their initial file size, disinfected and obturated by either CWC or OMTA using an enhanced disinfection protocol (GP disinfected, new gloves after each intraoperative radiograph and before starting obturation). Clinical and periapical radiographic examinations were conducted by two calibrated, independent endodontists during follow-up periods of at least 12&#x2009;months. Success rates and associated predictive factors (tooth-, operator- and patient-related) were analysed statistically using binary and multiple logistic regression (p&#x2009;<&#x2009;0.05). RESULTS: The median recall period was 30&#x2009;months (14-48&#x2009;months), and 104 teeth were finally analysed (recall rate: 86.67%). No significant differences in success rate were observed between the groups (p&#x2009;>&#x2009;0.05) under both loose (OMTA: 88.24%, CWC: 83.02%) and strict criteria (OMTA: 64.71%, CWC: 58.49%). Multivariate analysis revealed that age (OR&#x2009;=&#x2009;5.735, 95% CI: 1.286-25.577, p&#x2009;=&#x2009;0.022), periapical lesion size (OR&#x2009;=&#x2009;6.596, 95% CI: 1.397-31.138, p&#x2009;=&#x2009;0.017) and PAI score (OR&#x2009;=&#x2009;2.081, 95% CI: 1.047-4.136, p&#x2009;=&#x2009;0.036) were significant predictors of treatment failure. CONCLUSIONS: Orthograde obturation of infected canals with Ortho MTA III demonstrated comparable success and treatment outcomes to those filled with GP and sealer by CWC, supporting its potential as a clinically viable alternative for the obturation of infected root canals. TRIAL REGISTRATION: cris.nih.go.kr registration number: KCT00099939.

Humans

Surveilled subjectivation: narratives of drug policing among people who use prohibited drugs in Sweden.

In Sweden, possession and personal use of drugs are criminalized since 1988, resulting in police work being directed towards minor drug offenses. Despite this, police and other authorities are encouraged to protect the health and wellbeing of people who use prohibited drugs (PWUPD). Knowledge is scarce on how this drug policy plays out in practice. This study therefore analyzes interviews with 20 PWUPD who visited harm reduction services and interacted with policing agents in Stockholm, Sweden. The analysis is based on the participants' narratives of drug policing, and it concerns how they produced themselves as subjects through relations between materiality and discourse. We utilize the concept of surveilled subjectivation to elucidate what the participants could do, what they knew and who they could be or become under drug policing. Four themes were identified illustrating the link between discourse and materiality in PWUPD's surveilled subjectivation: "Material aspects of surveillance"; "Resisting the 'drug abuser' identity"; "Fighting power with power"; and "Crossing boundaries and becoming-other". The participants described nonstop efforts to prevent their bodies, activities, belongings and environments from being enfolded by drug law enforcement, which otherwise would fuel even more surveillance. They therefore disassociated themselves from the "drug abuser" identity, and managed encounters with policing agents by keeping a low profile or acting compliantly. While the study highlights the skills and knowledges the participants deployed to navigate omnipresent drug policing, we conclude that their production of autonomous and empowered subjectivities would be facilitated if possession and use of drugs were no longer criminalized.

Humans

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans

Clinical outcomes of zirconia dental restorations: A systematic review and meta-analysis.

OBJECTIVES: To evaluate the survival and success rates of zirconia dental restorations (ZDRs) and their complications. DATA & SOURCES: Electronic searches of PubMed, Cochrane, Embase and Web of Science were conducted up to January 1, 2026. Clinical studies with at least 1-year follow-up evaluating zirconia dental restorations in natural teeth were included. Survival rates, success rates, and biological and mechanical complications were analyzed. Risk of bias was assessed using RoB 2, Newcastle-Ottawa Scale (NOS), and Joanna Briggs Institute tools (JBI). Certainty of evidence was evaluated using the GRADE approach. STUDY SELECTION & RESULTS: Sixty-six studies published between 2008 and 2025 were included. Pooled survival rates ranged from 92.9% to 98.7% up to 10 years for single crowns (SCs), 77.6% over 10 to 13 years for fixed dental prostheses (FPDs), 97.4% for resin-bonded FPDs (RBFPDs) over 10 to 15 years, from 50.0% to 52.6% over 9 to 13 years for conventional cantilever FPDs (CFPDs) and 89.0% for inlay-retained FPDs (IRFPDs) over 10 years. Pooled success rates were 46.1% for SCs over 10 years, 40.1% for FDPs over 10 to 13 years, 84.3% for RBDPDs over 10 to 15 years, 12.5% to 22.6% for CFPDs over 9 to 13 years and 70.3% for IRFPDs over 10 years. Biological and mechanical complication rates were 12.1% and 53.9% for SCs at 10 years, 19.4% and 46.7% for FPDs over 10 to 13 years, 50.0% and 37.5% for CFPDs at 9 years, 21.4% and 14.3% for IRFPDs at 3 years, and 3.3% and 8.0% for RBFPDs over 10 to 15 years. Restorations treated with airborne-particle abrasion (APA) combined with 10-methacryloyloxydecyl dihydrogen phosphate (MDP) achieved favorable short-term clinical outcomes, with pooled survival and success rates of 98.6% and 97.7% for SCs, and 98.1% and 70.1% for IRFPDs, respectively. The included studies were assessed as having low to moderate risk of bias using RoB 2, NOS, and JBI tools, but GRADE assessment yielded evidence of very low certainty. CONCLUSIONS: ZDRs generally demonstrated acceptable to excellent short- to long-term survival and success outcomes. Mid- to long-term clinical performance was varied according to restoration types. The RBFPDs had relatively low complication rates, followed by the SCs, the FPDs and the IRFPDs. CFPDs exhibited relatively low success rates and high complication rates. The predominant biological complications were secondary caries and pulpitis or apical periodontitis, while chipping and debonding were the most common mechanical complications. APA treatment followed by application of MDP is capable of producing favorable short-term clinical outcomes. CLINICAL SIGNIFICANCE: ZDRs except for CFPDs could achieve favorable mid- to long-term clinical performance. CFPDs should be conducted with caution.

Zirconium

Pedagogical Efficacy of LLM-Generated Synthetic Data Versus Real-World Clinical Records: A Randomized Controlled Non-Inferiority Trial.

BACKGROUND: Expert-reviewed clinical cases generated by large language models (LLMs) may supplement case resources in medical education, but their short-term educational performance relative to real-case-derived teaching materials remains uncertain. We compared immediate post-training test performance after teaching with the two types of case materials and assessed non-inferiority against a prespecified margin. METHODS: We conducted a prospective, parallel-group, randomized non-inferiority trial. Through the Wenjuanxing online platform, participants were randomized 1:1 to learn with either real-case-derived teaching cases compiled by clinicians and reviewed by experts or AI-generated clinical cases produced by Gemini 3.0 Pro from fully de-identified matched real cases and reviewed by three senior general surgery specialists with full-professor rank. The primary outcome was the total score on an independent 10-item immediate post-training test (0-10 points), with a prespecified non-inferiority margin of -0.5 points. Secondary outcomes included the training-phase performance score, learning efficiency index, single-item mental effort rating, case realism, and case-source judgment. RESULTS: A total of 403 participants were randomized, of whom 386 were included in the modified intention-to-treat analysis: 192 in the real-case group and 194 in the AI-generated case group. The mean post-training test score was 4.95 (SD, 3.35) in the real-case group and 4.61 (SD, 3.35) in the AI-generated case group. The mean difference (AI-generated minus real-case group) was -0.335 points (95% CI, -1.006 to 0.337). Because the lower bound of the confidence interval was below the prespecified non-inferiority margin of -0.5 points, non-inferiority was not demonstrated (one-sided P = 0.314). No significant between-group differences were observed in the training-phase performance score, learning efficiency index, or single-item mental effort rating. AI-generated cases received lower realism ratings for Level 3 cases. The proportion of participants with at least one high-confidence completely incorrect response was 1.6% in the real-case group and 2.1% in the AI-generated case group. CONCLUSIONS: In this short-term, text-based online case-learning setting, no statistically significant between-group difference was observed in immediate post-training test performance; however, non-inferiority of AI-generated clinical cases relative to real-case-derived teaching materials was not demonstrated.

Humans

Thermal analysis techniques for microplastic mass quantification: Methodological challenges and standardization needs.

Microplastics (MPs, 1 &#x3bc;m-5 mm) and nanoplastics (NPs, <1&#x202f;&#x3bc;m) are ubiquitous contaminants requiring standardized quantification methods. This systematic review evaluates thermal analysis techniques for mass-based MP detection, including pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), thermogravimetry-MS (TGA-MS), thermal extraction desorption-GC-MS (TED-GC-MS), and differential scanning calorimetry (DSC). Database searches (Web of Science, from inception to December 1, 2025) following PRISMA guidelines identified studies across seven environmental matrices (water, soil/sediment, atmosphere, biota, human tissues). We identify critical standardization gaps: inconsistent marker ion selection, unvalidated conversion factors for tire and road wear particles (TRWPs), and the absence of certified reference materials for complex matrices. Py-GC-MS demonstrates versatility but suffers from lipid interference in biological samples; TED-GC-MS offers superior sensitivity (sample capacity &#x223c;200&#xd7; Py-GC-MS) but lacks real-time chromatographic monitoring. To advance data comparability, we propose: (i) harmonized ion selection hierarchies based on specificity-sensitivity balance, (ii) matrix-specific TRWP quantification protocols, and (iii) inter-laboratory validation using environmental reference materials. This review provides a methodological roadmap for standardizing thermal analysis in MP research.

Humans

Health bill beneath the plastic feast: A phthalate contamination alert from takeout food containers.

The rapid growth of takeout food consumption in China has raised concerns regarding exposure to phthalic acid esters (PAEs) from food packaging. This study investigated the presence, source, contribution, and health risk of PAEs in commonly used takeout containers. Widespread contamination was observed, with total PAE concentrations ranging from below the limit of detection to 222,000 ng/g. Diisobutyl phthalate (DIBP), dibutyl phthalate (DBP), and bis(2-ethylhexyl) phthalate (DEHP) were identified as the predominant compounds, accounting for 7.50 %, 14.7 %, and 18.7 % of the total concentration, respectively. These PAEs may originated from additives during manufacturing and potential contamination of raw materials. Human exposure assessment showed that daily exposure doses of DIBP, DBP, and DEHP via container ranged from 0.00 to 2340 ng/(kg&#xb7;day) among frequent takeout consumers, contributing substantially to overall PAE body burdens. To further assess exposure and associated risks, a nationwide online questionnaire survey was conducted across China. Based on this national-scale behavioral dataset, the health risks among Chinese residents were evaluated. Although the modeled non-carcinogenic risks of DIBP, DBP, and DEHP remained within acceptable limits, the simulation suggested that approximately 70 % of participants may experience potential exceedance of the carcinogenic risk threshold for DEHP. The frequency of takeout food consumption was identified as the most important factor affecting PAE exposure. These findings underscore the importance of limiting takeout frequency and reducing reliance on plastic containers to mitigate health risks. This study provides scientific evidence to support the development of safer packaging materials and informs public health strategies.

Phthalic Acids

A hybrid effectiveness-implementation trial to integrate precision skin cancer risk feedback in federally qualified health centers.

BACKGROUND: Skin cancers are the most common type of cancer in the United States, occur in all segments of the population, and are preventable. Our previous research with primary care patients' demonstrated interest in and efficacy of a precision prevention intervention providing feedback on MC1R risk level (higher versus average) in combination with prevention education materials relative to a standard educational intervention. Our current study is a hybrid type 1 effectiveness-implementation trial deployed at six federally-qualified health centers. This paper presents the study protocol. METHODS: A community advisory panel will guide development of study materials and measures. Staff training at each clinic will be completed in-person. Patients will be approached and screened in-person. Those completing genetic testing and the baseline survey will be randomized to the precision versus standard intervention for each risk level with a target sample size of 286 for each combination. Primary outcomes of effectiveness, assessed at 6 and 12&#xa0;months, include a tanning score (5 items assessing intentional and unintentional tanning), number of sunburns, conduct of a skin self-examination, and electronic health record documentation of clinician-patient communication about skin cancer prevention. Effectiveness comparisons will focus on the precision relative to the standard intervention among higher risk participants. Implementation data will be collected to identify barriers and facilitators. RESULTS: Effectiveness and implementation outcomes will be evaluated following study completion. CONCLUSIONS: Results will guide subsequent scale-up of the precision intervention, including modifications of the intervention as well as methods for implementation. CLINICAL TRIALS IDENTIFIER: NCT07222995.

Humans

Exploring the Diagnostic Utility of Ferumoxytol for Brachial Plexus MR Neurography.

Background Ferumoxytol has been described as an alternative contrast agent for vascular suppression in MR neurography (MRN), but its diagnostic utility in patients has yet to be evaluated. Purpose To evaluate the impact of ferumoxytol on vascular suppression, nerve conspicuity, and evaluation of nerve abnormalities at three-dimensional (3D) brachial plexus MRN, compared with noncontrast and gadolinium-enhanced MRN, in participants with suspected Parsonage-Turner syndrome (PTS) or thoracic outlet syndrome (TOS). Materials and Methods This prospective study included participants who underwent 3D MRN with and/or without gadolinium chelate for clinical suspicion of PTS or TOS and subsequently underwent 3D MRN with ferumoxytol (within 3 months of the clinical examination). Two musculoskeletal radiologists qualitatively evaluated 3D short-tau inversion-recovery fast spin-echo scans for the degree of vascular suppression, nerve conspicuity, and presence of nerve abnormalities. Wilcoxon signed-rank or McNemar tests were used for comparing noncontrast and gadolinium-enhanced scans with ferumoxytol-enhanced scans. Results This study included 18 participants (mean age, 42 years &#xb1; 15.2 [SD]; 10 men). Ferumoxytol-enhanced scans demonstrated improved vascular suppression compared with both noncontrast scans (both raters, P < .001) and gadolinium-enhanced scans (both P = .04). For rater 2, ferumoxytol-enhanced acquisitions demonstrated improved conspicuity of several nerve segments relative to the noncontrast scan, including segments of the suprascapular (P = .01), axillary (P = .02), and long thoracic nerves (P = .004). The distribution of scores for these nerve segments for rater 1 also favored ferumoxytol-enhanced versus noncontrast scans, but the differences were not statistically significant (all P &#x2265; .06). There was no evidence of a difference in nerve conspicuity between ferumoxytol-enhanced and gadolinium-enhanced scans (P &#x2265; .17 for all nerve segments) and also no evidence of discrepancies in abnormal nerve findings between the acquisitions (all P &#x2265; .48). Conclusion Ferumoxytol improved vascular suppression compared with noncontrast and gadolinium-enhanced 3D short-tau inversion-recovery fast spin-echo sequences in brachial plexus MRN, enhancing the conspicuity of several nerve branches versus noncontrast scans, with similar detection of abnormal nerve findings. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans