An outbreak of bronchoscopy-related Mycobacterium tuberculosis infections due to lack of bronchoscope leak testing.

BACKGROUND: Bronchoscopy-related transmission of Mycobacterium tuberculosis is rarely reported. In August 1999, five M tuberculosis-positive bronchial washing culture findings were noted in patients who underwent bronchoscopy in July in a hospital that reported only eight M tuberculosis-positive culture findings from 1995 to 1998, prompting further investigation. METHODS: A case was defined as a M tuberculosis-positive culture finding from specimens obtained from patients who underwent bronchoscopy during January to August of 1999. Bronchoscopy and laboratory records, procedures, and practices were reviewed. M tuberculosis isolates were compared using restriction fragment length polymorphism (RFLP) analysis. RESULTS: During July 1999, 19 bronchoscopic procedures were performed in 19 patients. Bronchial washing specimens for mycobacterial culture were obtained from 18 patients. Ten cases were identified. Two case patients, including the index patient, had signs and symptoms of active tuberculosis prior to bronchoscopy. M tuberculosis infections developed in two more case patients despite starting a standard four-drug antituberculous regimen within 3 weeks after bronchoscopy. Six case patients had positive culture findings but no evidence of infection. All M tuberculosis isolates were antituberculosis-drug susceptible, and all but one were indistinguishable by RFLP analysis. Three bronchoscopes were used during the outbreak period; one bronchoscope was used in 9 of the 10 case patients (relative risk, 8.1; 95% confidence interval, 1.3 to 52). A hole was discovered in the sheath of this bronchoscope. Leak testing, a critical step in bronchoscope reprocessing, was not routinely performed at this institution. CONCLUSIONS: M tuberculosis contamination of the bronchoscope occurred during the index patient's procedure. The hole in the sheath provided access to a space that was difficult to mechanically clean and chemically disinfect. The reprocessing recommendations of bronchoscope manufacturers, including leak testing after each use, should be closely followed.

Adult↗

[CT-guided transbronchial diagnosis using ultrathin bronchoscope for small peripheral pulmonary lesions].

We performed computed tomography (CT)-guided transbronchial diagnosis on 23 patients, using an ultrathin bronchoscope (external diameter, 2.8 mm) for small peripheral pulmonary lesions (< or = 2 cm). The mean size of the lesions was 1.4 x 1.1 cm. After examination using a conventional bronchoscope (external diameter, 6.3 mm), an ultrathin bronchoscope and a biopsy apparatus were advanced to the lesion under CT and X-ray fluoroscopic guidance. The location of the biopsy apparatus at each lesion was confirmed by thin-section CT, and a biopsy was performed. The ultrathin bronchoscope reached the 5th-11th bronchus (mean, 7.1 +/- 1.5th), at a point 3.6 +/- 0.9 bronchi peripheral to the site reached using a conventional bronchoscope. In 20 of the 23 patients, the biopsy apparatus could be guided to the lesion. The diagnosis rate, by disease, was 81.8% (9/11) for lung cancer, 66.7% (2/3) for metastatic lung cancer, and 77.8% (7/9) for inflammation; the overall rate being 78.3% (18/23). CT-guided transbronchial diagnosis using an ultrathin bronchoscope is useful for diagnosing small peripheral pulmonary lesions because the bronchoscope can be readily inserted into peripheral areas and guided to lesions, and the site of sample collection can be accurately determined.

Adult↗

[The history of evolvement of bronchoscope].

Since 1897, the year when the bronchoscope was invented, the instrument have experienced three stages of evolvement, namely, the period of conventional rigid bronchoscope, the period of flexible fibreoptic bronchoscope as well as the period of the combined use of electronic bronchoscope, broncho fibrescope and video-assisted rigid bronchoscope simultaneously. Bronchoscope plays a significant role in the fields of thoracic surgery and respiratory internal medicine. In China, the technique started rather late, but after years of hard work, it has approached or reached the international advanced level. The blossoming new techniques and their upgrading make bronchoscope play an even more important role in the interventional pulmonology.

Bronchoscopes↗

Hybrid bronchoscope tracking using a magnetic tracking sensor and image registration.

In this paper, we propose a hybrid method for tracking a bronchoscope that uses a combination of magnetic sensor tracking and image registration. The position of a magnetic sensor placed in the working channel of the bronchoscope is provided by a magnetic tracking system. Because of respiratory motion, the magnetic sensor provides only the approximate position and orientation of the bronchoscope in the coordinate system of a CT image acquired before the examination. The sensor position and orientation is used as the starting point for an intensity-based registration between real bronchoscopic video images and virtual bronchoscopic images generated from the CT image. The output transformation of the image registration process is the position and orientation of the bronchoscope in the CT image. We tested the proposed method using a bronchial phantom model. Virtual breathing motion was generated to simulate respiratory motion. The proposed hybrid method successfully tracked the bronchoscope at a rate of approximately 1 Hz.

Algorithms↗

[Value of fiberoptic bronchoscope in children with epiglottitis].

Acute epiglottitis is an infectious disease causing a severe respiratory distress. Any attempt to move the child in the horizontal position or to examine his throat can result in cardiac arrest. Diagnosis, endotracheal intubation as well as decision making of the optimal time for extubation are greatly facilitated by the use of a fiberoptic bronchoscope. The device is a paediatric model (external diameter 3.6 mm with an operating channel). It is inserted through the nare in the child in the sitting position. Oxygen is delivered through a nasal tube. The examination is performed under local anaesthesia (lidocaine 0.5%). Midazolam is sometimes added via the rectal or i.v. route. The clinical signs are monitored as well as the heart rate and SpO2. The diagnosis of epiglottitis as it is visual, is very easy and rapid once the epiglottis is observed through the fibreoptic bronchoscope. The advantage of the examination under fibreoptic bronchoscope is to allow visualization without aggression or stimulation of the pharyngolaryngeal structures and without modification of the child's position. Endotracheal intubation, which is always required, is facilitated as the child is breathing spontaneously. The expiratory flow blows bubbles of saliva, which guide the bronchoscope to the glottis. When the internal diameter of the endotracheal tube is larger than 4 mm, the bronchoscope is used as a guide. When it is less than 4 mm. the bronchoscope is inserted in the trachea with a guide wire slipped in the operating channel; the bronchoscope, but not the wire is withdrawn and the endotracheal tube is inserted over the guide wire.(ABSTRACT TRUNCATED AT 250 WORDS)

Bronchoscopy↗

Non-bronchoscopic sampling and culture of bronchial epithelial cells in children.

BACKGROUND: The bronchial epithelium is likely to play a vital role in airway diseases in children, such as asthma and viral-associated wheeze. In adults, studies with primary bronchial epithelial cells cultured from samples obtained by fibre-optic bronchoscopy have provided key insights into the role of the epithelial cell. However, it is difficult to justify bronchoscopy in children to obtain epithelial cells for research purposes. OBJECTIVE: To examine the possibility of retrieving and culturing viable epithelial cells using a blind non-bronchoscopic method from children undergoing elective surgery. METHODS: Subjects were children undergoing elective surgery under general anaesthesia. Following intubation, non-bronchoscopic bronchoalveolar lavage and non-bronchoscopic bronchial brushing were performed. A sheathed bronchial cytology brush was advanced through the endotracheal tube, wedged and then withdrawn 2-3 cm before gentle sampling was used to collect bronchial epithelial cells. Initial samples were used to characterize the number, type and viability of epithelial cells recovered compared to a control group of adults undergoing standard bronchoscopic sampling. Subsequent samples were used to establish primary bronchial epithelial cell cultures in children both with and without wheezing illness. RESULTS: A total of 63 children underwent bronchial brushing [38 male; median age 7.1 years (1.0-14.2 years]. Initial samples (n=30) showed recovery of viable epithelial cells comparable to that from a single brush obtained via a bronchoscope in an adult control group (n=11). In 27 (82%) of the subsequent 33 samples obtained non-bronchoscopically from children, primary bronchial epithelial cell cultures were successfully established. There were no adverse effects attributable to sampling. CONCLUSION: We have shown that non-bronchoscopic bronchial brushing is a safe and effective technique for recovering viable bronchial epithelial cells that consistently yield primary cultures. This method will facilitate examination of the role of the epithelium in paediatric disease.

Adolescent↗

Radiographically occult lung cancer treated with fibreoptic bronchoscopic electrocautery: a pilot study of a simple and inexpensive technique.

The curative potential of bronchoscopic intervention, e.g. photodynamic therapy (PDT) and brachytherapy, for resectable radiographically occult lung cancer has been reported previously. Bronchoscopic electrocautery is currently feasible using an insulated flexible bronchoscope to coagulate and vaporize tumour tissue. Since the lesions are usually small, noninvasive bronchoscopic electrocautery may be able to eradicate radiographically occult lung cancer completely. In a prospective study, 13 patients with 15 radiographically occult lung cancer lesions were treated with bronchoscopic electrocautery. The duration of follow-up was > or = 16 months. The median age of the patients was 69 yrs (range 48-79 yrs). Fibreoptic bronchoscopy under local anaesthesia was used to coagulate the occult lung cancer. Approximately 30 W of energy was applied until visible necrosis of the tumour area became apparent. There were no immediate complications. In 10 patients with 12 lesions, a complete response (CR) was obtained (CR rate 80%; 95% confidence interval (95% CI) 52-96%). Median duration of follow-up was 21 months (range 16-43 months). Bronchoscopic electrocautery did not obtain a CR in the remaining three patients, but PDT also failed to achieve CR. Two patients underwent radical resection, and the tumours were histologically confirmed to be more invasive. One patient received external radiotherapy. Three patients with a CR died during follow-up, two as a result of myocardial infarction and apoplexy, and one because of metastasis from his previously resected T3N1 primary large cell cancer. Current data show bronchoscopic electrocautery to be equally effective and potentially as curative as photodynamic therapy for treating patients with radiographically occult lung cancer. Obvious advantages are that it is an inexpensive and simple procedure, which does not cause photosensitivity.

Aged↗

Bronchoscopic therapy in patients with intraluminal typical bronchial carcinoid.

OBJECTIVE: To study the efficacy of bronchoscopic therapy in patients with intraluminal typical bronchial carcinoid. DESIGN: Retrospective analysis of the data of patients with bronchial carcinoid, treated primarily with bronchoscopic techniques such as Nd-YAG laser in various hospitals in the Netherlands. SUBJECTS: Eleven patients with pulmonary complaints, ages 22 to 60 years, who were found to have intraluminal typical bronchial carcinoid. BRONCHOSCOPIC INTERVENTIONS: Six of the 11 patients received Nd-YAG laser treatments, one received Nd-YAG laser plus photodynamic therapy, and the other four had mechanical tumor removal. RESULTS: Six patients were surgically treated after bronchoscopic therapy. The resected specimens showed no residual carcinoid. Median follow-up has been 70 months (range, 9 to 170 months). Five patients were not surgically treated after bronchoscopic therapy. Follow-up has been 27 to 246 months (median, 47 months) without signs of recurrence. CONCLUSIONS: In 11 patients with typical, intraluminal, bronchial carcinoids, bronchoscopic treatment seemed to result in excellent local control, with surgical proof of cure in 6 of 11 patients. Bronchoscopic approach may provide a tissue-sparing alternative for bronchoplastic surgery in a subset of patients with typical intraluminal bronchial carcinoids.

Adult↗

Adequately washed bronchoscope does not induce false-positive amplification tests on bronchial aspirates in the diagnosis of pulmonary tuberculosis.

STUDY OBJECTIVES: To investigate the clinical usefulness of amplification (COBAS AMPLICOR; Roche Diagnostics Systems; Branchburg, NJ) on bronchoscopic aspirate specimens in the diagnosis of pulmonary tuberculosis, with particular regard to the possibility of false-positive results in subsequent specimens due to residual Mycobacterium tuberculosis DNA. DESIGN AND SETTING: A prospective clinical study at a tertiary referral medical center. PARTICIPANTS AND METHODS: Four hundred fiberoptic bronchoscopic procedures were performed, using seven bronchoscopes on 335 consecutive patients, for therapeutic or diagnostic purposes. Serial bronchial aspirates were collected and tested for M tuberculosis, using COBAS AMPLICOR (CA). Bronchoscopes were cleaned and disinfected automatically, between patient use, by the same endoscope washer. The name of each bronchoscope and the sequence of its use were recorded, together with the sequence of washing. The CA results were compared with the bacteriologic and histologic results for M tuberculosis infection. When there was a suspicion of contamination, outward polymerase chain reaction analysis was performed. RESULTS: Of 392 specimens (332 subjects), excluding the 8 specimens (4 subjects) in which bacteriologic and histologic analyses were omitted, a smear-positive result for acid-fast bacilli (AFB), culture-positive or biopsy-positive results, and CA-positive results were obtained in 16, 49, and 32 specimens, respectively. In AFB smear-positive subjects, the sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs) were 92%, 67%, 92%, and 67%, respectively. In AFB smear-negative subjects, the sensitivity, specificity, PPV, and NPV values were 38%, 99%, 74%, and 94%, respectively. The CA test was more sensitive than the AFB smears for the diagnosis of pulmonary tuberculosis (53% vs 27%, respectively; p < 0.05). False-positive CA results were seen in only six specimens. Three of these six subjects received a diagnosis of pulmonary tuberculosis on clinical and radiologic grounds, and none of the six results seemed to be associated with bronchoscopic cross-contamination. CONCLUSIONS: Adequately cleaned and disinfected bronchoscopes did not cause false-positive amplification test results for M tuberculosis on bronchial aspirates by cross-contamination. Furthermore, sensitivity was greater with the CA tests. Therefore, CA tests on bronchial aspirates seem to be useful in the diagnosis of pulmonary tuberculosis.

Adult↗

The curative potential of intraluminal bronchoscopic treatment for early-stage non-small-cell lung cancer.

Bronchoscopic treatment modalities such as lasers, electrocautery, cryotherapy, photodynamic therapy, and brachytherapy are potentially curative for patients with very-early-stage non-small-cell lung cancer (NSCLC) in the central airways. Previously, studies had primarily focused on the effectiveness of surgery, surgical bronchoplasty, and photodynamic therapy. The cure rate of intraluminal bronchoscopic treatment is strongly related to the patient's functional status and tumor stage. Intraluminal tumors are curable bronchoscopically when they are accessible to the fiberoptic bronchoscope, strictly intraluminal, and superficial with visible proximal and distal tumor margins. Early-stage cancer infiltrating deeper into the bronchial wall may already harbor metastases to the regional lymph nodes; hence, curative intraluminal treatment is not feasible. The use of new diagnostic tools (eg, high-resolution computed tomography, autofluorescence bronchoscopy, and endobronchial ultrasound) may improve staging to select the category of patients in whom intraluminal bronchoscopic therapy with curative intent is appropriate. An accurate intraluminal tumor staging will improve our ability to exploit the curative potential of many bronchoscopic techniques for complete tumor eradication in patients with very-early-stage intraluminal NSCLC in their central airways. The use of bronchoscopic treatment as a less morbid alternative than surgical resection will benefit patients most when tumor is detected at the earliest stage possible.

Journal Article↗

Bronchoscopic ultrasonography in the diagnosis of tracheobronchial invasion of esophageal cancer.

OBJECTIVE: To study the usefulness of bronchoscopic ultrasonography in diagnosing tracheobronchial invasion of esophageal cancer and to compare it with endoscopic ultrasonography, bronchoscopy, and computed tomography. METHODS: We prospectively investigated 59 patients with newly diagnosed esophageal cancer located at or above the level of the tracheal bifurcation. A 20-MHz ultrasonic probe covered by a sheath with a balloon inflated with water was used for bronchoscopic ultrasonography. The presence of tracheobronchial invasion was diagnosed on the basis of an interruption in the most external hyperechoic layer of the tracheal bronchus. RESULTS: Bronchoscopic ultrasonography was completed without complications in all patients, but endoscopic ultrasonography was performed completely in only 44% of them. The overall accuracy rates for diagnosis of tracheobronchial invasion on the basis of bronchoscopy, bronchoscopic ultrasonography, endoscopic ultrasonography, and computed tomography were 78%, 91%, 85%, and 58%, respectively. Statistical examination showed that the accuracy of bronchoscopic ultrasonography and bronchoscopy was significantly greater than that of computed tomography, and the accuracy of bronchoscopic ultrasonography was greater than that of bronchoscopy. CONCLUSIONS: Bronchoscopic ultrasonography is useful for evaluating cancer invasion into the tracheal bronchus. It is more accurate than the other methods and could be used to visualize the layered structure of the tracheal bronchus in all patients.

Aged↗

Diameter of paediatric sized flexible bronchoscopes: when size matters.

BACKGROUND: A flexible bronchoscope typically gets its designated size from the diameter of the distal tip but this is not the maximum diameter of the insertion tube. AIM: The aim of this study was to determine the size and site of the maximum diameter of flexible bronchoscope insertion tubes and to compare standard bronchofiberscopes with newer bronchovideoscopes. METHODS: We assessed 10 bronchoscopes ranging from 2.2 to 4.9 mm external diameter (Olympus, Tokyo, Japan) using an electronic digital caliper. Investigators were blinded to the type and model of each scope. The median, minimum and maximum diameters of the bronchoscopes were calculated and the measured diameters were compared with the stated diameters of the distal tip and insertion tube. RESULTS: The maximum and median measured diameters were wider than the stated diameter of the distal tip in all the scopes. The maximum discrepancy between the measured and stated diameters ranged from 0.19 mm (6.7%) to 0.66 mm (22.2%) with a mean of 0.41 mm (14.0%). There was no difference between bronchofiberscopes and bronchovideoscopes. CONCLUSION: The maximum diameter of the distal tip and insertion tube of pediatric sized flexible bronchoscopes is significantly greater than the manufacturer's specifications. This may impact on the choice of bronchoscope selected for procedures in children.

Bronchoscopes↗

Mycobacterial contamination of fibreoptic bronchoscopes.

Because of the increasing numbers of immunosuppressed patients and the general resurgence of mycobacterial infection, diagnostic bronchoalveolar lavage (BAL) using a fibreoptic bronchoscope is an important and frequent procedure. A contaminated bronchoscope may introduce spurious mycobacteria into specimens causing diagnostic confusion, infect the patient with mycobacteria, or be a vehicle for cross-infection. Bronchoscopes are difficult to disinfect adequately if they are not properly cleaned (which may include stripping down channel valves) or are damaged. Bronchoscope washers have also contributed to the problem when glutaraldehyde becomes too dilute or they become heavily contaminated with environmental mycobacteria. Future solutions to prevent contamination include the regular maintenance of bronchoscopes and washers, having adequate cleaning and disinfection protocols and ensuring that they are adhered to, improving bronchoscope and washer design, and developing alternative disinfectants or new ways of using current ones. All these will probably have considerable cost implications for hospitals.

Bronchoalveolar Lavage Fluid↗

Respiratory acidosis with the small Storz-Hopkins bronchoscopes: occurrence and management.

Carbon dioxide retention in the Storz rigid ventilating bronchoscope with the Hopkins lens system was investigated in the laboratory. The 3.5, 4.0, and 5.0 30-cm Storz bronchoscopes with a 3.95-mm (outside diameter) telescope lens were used in 10 mongrel dogs weighing between 8 and 15 kg. Significant (p less than 0.01) accumulation of arterial carbon dioxide tension (PaCO2) (respiratory acidosis) was observed after 5 and 10 minutes of ventilation through the 3.5 and 4.0 bronchoscopes, but no significant increase in PaCO2 was noted with the 5.0 bronchoscope. There was no significant change in arterial oxygen tension under the same conditions. Manual compression of the upper anterior abdominal wall during expiration was applied during bronchoscopy in 6 children. Arterial blood samples were taken before insertion of the bronchoscope and 5 minutes later with and without abdominal compression during expiration. A significant increase (p less than 0.05) in PaCO2 and a decrease in pH were observed after 5 minutes of the bronchoscopic procedure without manual compression of the abdominal wall, while no significant changes in PaCO2 were observed with abdominal compression.

Abdominal Muscles↗

[A new rigid bronchoscope with a measuring tube for pressure and capnometry].

BACKGROUND: Pulmonary gas exchange under jet ventilation is usually controlled by pulse-oxymetry and blood gas analysis. Capnometry is not common in clinical use. Rigid bronchoscopes with pressure measurements are not known. Our aim was the development of a rigid bronchoscope with a built-in tube for the online measurement of airway pressure and gas composition. METHODS: We measured the distribution of inspiratory pressure under jet ventilation over the length inside a 8 x 400 mm rigid bronchoscope in a lung model and in patients. A measuring tube was constructed for obtaining representative values of airway pressure and capnometry. Using a prototype of a new rigid bronchoscope with the built-in measuring tube (R. Wolf Company, Knittlingen, Germany) inspiratory pressure and expiratory CO2 were measured during interventional bronchoscopy. The measuring tube was connected to the pressure control port of the jet ventilator. We applied jet ventilation with frequencies of 10 to 12 pulses per minute. RESULTS: The inspiratory pressure reaches after 10 cm distally the instrumental port a significant constant plateau. Via the built-in measuring tube representative measurement of pressure and gas can be made there. The correlation between arterial CO2 (paCO2) and expiratory CO2 (petCO2) was excellent (r = 0.96). To maintain normocapnia in 25 patients undergoing interventional bronchoscopy, the jet pressure had to be adjusted to values between 0.5 and 3.5 bar (median 2.5 bar). The responding inspiratory pressure varied from 3 to 25 mbar (median 15 mbar). A flexible bronchoscope in the working channel raises the airway pressure from 18 to 23 mbar. The automatic interruption of the jet-pulses by connecting the measuring tube to the pressure control port of the ventilator in order to prevent a barotrauma was found feasible. CONCLUSIONS: Simultaneous online control of airway pressure and gas is possible with the new rigid bronchoscope. Pressure depending jet ventilators can be controlled via the measuring tube to minimise the risk of barotrauma.

Airway Resistance↗

Contamination of bronchoscopes with Mycobacterium tuberculosis and successful sterilization by low-temperature hydrogen peroxide plasma sterilization.

BACKGROUND: The transmission of mycobacteria by bronchoscopes has been reported several times in the last years. To explore methods to prevent transmission of tuberculosis in this way, we sterilized contaminated bronchoscopes with low-temperature hydrogen peroxide gas plasma sterilization. METHODS: Bronchoscopes were contaminated with Mycobacterium tuberculosis and decontaminated with a washer/disinfector ("normal washing"). Some were additionally disinfected with glutaraldehyde ("intensive washing"). Afterward the bronchoscopes were sterilized by low-temperature hydrogen peroxide plasma sterilization. RESULTS: After normal washing, 8/17 samples had positive results by culture, and 7/17 had positive results by nucleic acid amplification technique. After intensive washing, all samples had negative results by culture, and 10/25 had positive results by nucleic acid amplification technique; after sterilization with low-temperature hydrogen peroxide plasma sterilization, all samples had negative results by culture and nucleic acid amplification technique. CONCLUSION: Washing of bronchoscopes, as performed normally, is not sufficient for decontamination of bronchoscopes. Additional disinfection is recommended. If the nucleic acid amplification technique is used for diagnostic procedures, sterilization by low-temperature hydrogen peroxide plasma sterilization is recommended to avoid false-positive results.

Anti-Infective Agents, Local↗

A virtual bronchoscopic navigation system for pulmonary peripheral lesions.

STUDY OBJECTIVES: We performed ultrathin bronchoscopy for pulmonary peripheral lesions using a system that displays virtual bronchoscopy (VB) images to the lesion simultaneously with actual images and navigates the bronchoscope to the target bronchus. We then evaluated the system with regard to its usefulness and problems. DESIGN: A pilot study. SETTING: A tertiary teaching hospital. PATIENTS: The subjects were consecutive patients with small pulmonary peripheral lesions (< or = 30 mm). INTERVENTIONS: Using this system, the rotation, advancement, and retreat of VB images were possible, and the bronchus into which the bronchoscope was to be advanced was displayed. VB images were displayed along with actual images, and the ultrathin bronchoscope was advanced to the target bronchus under direct vision. Under CT and radiographic fluoroscopy, a pair of forceps was inserted into the lesion via the bronchoscope. Thin-section CT images were obtained; after confirming the advancement of the bronchoscope into the target bronchus and the arrival of the forceps at the lesion, a biopsy was performed. RESULTS: Study subjects included 37 patients with 38 lesions. VB images to a median of the sixth- (third- to ninth-) order bronchi could be produced. Using this system, the ultrathin bronchoscope could be advanced into the planned route for 36 of the 38 lesions (94.7%). The system was used for a median of 2.6 min, and the median examination time was 24.9 min. The biopsy forceps could be advanced to the lesion in 33 of the 38 lesions (86.8%), and diagnosis was possible for 31 lesions (81.6%). CONCLUSIONS: This navigation system is useful for ultrathin bronchoscopy for pulmonary peripheral lesions.

Adult↗

A comparison of biopsy results using rigid and fibreoptic bronchoscopes.

A comparison of the results of bronchial biopsy in the histological diagnosis of lung cancer obtained via the fibreoptic bronchoscope and the rigid bronchoscope has been made. Positive biopsy rates of 72% with the fibreoptic bronchoscope and 51% with the rigid bronchoscope were obtained (P less than 0.001). Evidence is presented to show that this difference was not due to selection of patients. The negative biopsy rates in the presence of proven visible tumour were 9% with the fibreoptic bronchoscope and 16% with the rigid bronchoscope.

Bronchi↗