Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Atrial Appendage”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Left atrial appendage function and thrombus formation in atrial fibrillation-flutter: a transesophageal echocardiographic study.

OBJECTIVES: The purpose of this study was to investigate left atrial appendage size, function and thrombus prevalence in patients with atrial "fibrillation-flutter." BACKGROUND: Thrombus formation and peripheral embolization in atrial fibrillation are related to left atrial appendage dysfunction. Embolization occurs less frequently in atrial flutter. It is not known whether the atrial appendage in fibrillation-flutter, which has an intermediate appearance on the surface electrocardiogram (ECG), has distinct characteristics that could affect thrombus formation. METHODS: Sixty-one patients with atrial tachyarrhythmias underwent transesophageal echocardiographic examination of the left atrial appendage. Appendage area, peak emptying velocity and the presence of thrombus and spontaneous echo contrast were determined. The results for 14 patients with fibrillation-flutter (based on ECG fibrillatory wave characteristics) were compared with those for 30 patients with atrial fibrillation and 17 patients with atrial flutter. RESULTS: Both fibrillation-flutter and atrial fibrillation were associated with chaotic appendage flow patterns with similarly low peak emptying velocities (18 +/- 8 and 17 +/- 10 cm/s, mean +/- 1 SD, respectively). Atrial flutter was associated with a regular pattern of appendage contraction and a significantly higher peak emptying velocity (42 +/- 18 cm/s, p < 0.0001). Mean appendage area was similar for fibrillation-flutter and fibrillation (6.3 +/- 2.2 and 6.7 +/- 2.1 cm2, respectively) but was significantly smaller for atrial flutter (5.3 +/- 1.4 cm2, p < 0.05). The prevalence of left atrial appendage thrombus was similar for fibrillation-flutter and atrial fibrillation (40% and 29%, respectively), whereas no patient with atrial flutter had a thrombus (p < 0.05). Similarly, the presence of spontaneous echo contrast was higher for fibrillation-flutter (50%) and atrial fibrillation (40%) than for atrial flutter (6%, p < 0.05). CONCLUSIONS: Left atrial appendage size and function in atrial fibrillation-flutter are indistinguishable from those of typical atrial fibrillation, and the frequency of thrombus and spontaneous echo contrast is similarly high. This is in contrast to atrial flutter, which is characterized by a smaller, more contractile left atrial appendage and a lower frequency of thrombus and spontaneous echo contrast.

Aged↗

Interference of mitral valve stenosis with left ventricular diastole and left atrial appendage flow.

Atrial fibrillation (AF) has been reported as an independent risk factor of systemic thromboembolism. Almost half of the left atrial thrombi are located in the left atrial appendage (LAA). LAA function, reflected by LAA flow, thus has an influence on the potential of distal embolic complications. To identify factors other than atrial contraction that influence LAA flow during AF, transthoracic and transesophageal echocardiographic studies were performed on 130 patients. Seventy patients with nonrheumatic AF were divided into two groups with higher peak LAA outflow velocity (group 1) and lower peak LAA outflow velocity (group 2) at the ventricular systolic phase. Sixty patients with rheumatic AF were classified as group 3. Group 1 had a higher peak LAA outflow velocity than group 2 at both the ventricular systolic and diastolic phases. Group 2 had a higher peak LAA outflow at the ventricular diastolic phase than group 3 (18.9 +/- 8.0 vs. 11.8 +/- 7.5 cm/s, p < 0.001), whereas there was no significant difference in the peak LAA outflow at the ventricular systolic phase between the two groups (9.6 +/- 4.0 vs. 10.8 +/- 6.8 cm/s, p = NS). Group 3 was subdivided according to mitral valve area. Patients with severe mitral stenosis (mitral valve area < 1 cm2) had a significantly lower diastolic augmentation of LAA outflow velocity (difference of LAA outflow velocity between ventricle systole and diastole) than patients with mild to moderate stenosis (0.5 +/- 3.2 vs. 2.6 +/- 4.9 cm/s, p < 0.05). In conclusion, patients with rheumatic AF, especially those with severe mitral stenosis, have a lower diastolic augmentation of LAA outflow velocity. The lower diastolic augmentation of the LAA outflow velocity at the ventricular diastolic phase might result from interference with the suction effect of the left ventricular diastole by the stenotic mitral valve.

Aged↗

Percutaneous left atrial appendage transcatheter occlusion for patients with atrial fibrillation unable to take warfarin.

Anticoagulation with warfarin for atrial fibrillation is frequently difficult. A transcatheter method to exclude the left atrial appendage from the circulation could be an advantage for selected patients. Percutaneous left atrial appendage transcatheter occlusion is a catheter-based delivery of an occlusive nitinol cage to the neck of the left atrial appendage. The device obliterates the left atrial appendage, eliminating a major source of thromboembolism. Animal studies have confirmed device coverage with an endocardial layer within 6 months and distal atrial appendage fibrosis. A standard transseptal approach from the right femoral vein is used. Patients leave the hospital within 1 day. Six-month follow-up of European and US safety and efficacy trials has shown favorable outcomes in minimizing thromboembolic events and few complications related to placement or healing of the device. Further clinical studies will be needed to establish which patients will be best treated with this device.

Age Factors↗

Left atrial appendage function after internal atrial defibrillation.

To determine the value of echocardiographic parameters for predicting maintenance of sinus rhythm after internal atrial defibrillation (IAD), transthoracic and transesophageal echocardiography were performed in 38 patients with atrial fibrillation (AF) before IAD. In addition, serial echocardiographic examinations were performed at 1, 7, and 28 days after IAD in 20 patients to assess the effect of IAD on echocardiographic markers of thromboembolic risk. AF had recurred in 49% of patients within 6 months following IAD. Left atrial chamber and appendage size and ejection fraction were not predictive of recurrence of atrial fibrillation. However, peak emptying velocities of the left atrial appendage were significantly lower in patients with recurrence of atrial fibrillation as compared with patients who had maintained sinus rhythm (0.26 +/- 0.1 m/sec vs 0.49 +/- 0.17 m/sec; P = 0.001). A peak emptying velocity < 0.36 m/sec had a sensitivity of 82% and specificity of 83% for predicting the recurrence of AF. Peak A wave velocities increased gradually after cardioversion from 0.47 +/- 0.16 m/sec at 24 hours to 0.61 +/- 0.13 m/sec after 7 days (P < 0.05). One patient developed a new thrombus in the left atrial appendage and another patient suffered a thromboembolic event after IAD. Assessment of left atrial appendage function adds information regarding the probability of maintaining sinus rhythm after the procedure and the need for anticoagulation therapy with IAD.

Anticoagulants↗

Thromboembolus from a ligated left atrial appendage.

The left atrial appendage of patients with mitral valve disease is commonly a source of thromboembolus and is often ligated during mitral valve surgery to diminish this risk. However, ligation is often incomplete. We describe a patient with a stroke whose only source of embolus was an incompletely ligated left atrial appendage. Attempts to exclude the left atrial appendage from the arterial circulation by suture ligation may not decrease the risk of thromboemboli and instead may increase such risk.

Aged↗

Differences in pacing from the atrial appendage and the lateral atrial free wall on left ventricular filling and haemodynamics during DDD pacing.

INTRODUCTION: Atrioventricular sequential pacing involves stimulation from electrodes in the right atrium, generally the atrial appendage (RAA) and the right ventricular apex. The appendage, however, may be unsuitable if a stable position cannot be achieved. The aim of this study was to assess the haemodynamic consequences of different atrial stimulation sites during DDD pacing. METHODS: In 12 consecutive patients (mean age 67 +/- 7 years) who underwent DDD pacemaker implantation, an additional temporary bipolar pacing electrode was positioned on the right atrial free wall. Pacing was performed alternating from the two locations at 85, 100 and 120 beats per minute (bpm). Paced atrioventricular delay was set at 180 ms. Cardiac output and mitral inflow measurements were performed using Doppler echocardiography. RESULTS: Pacing at 85 and 100 bpm resulted in a significantly higher A-peak velocity from the RAA compared with the right atrial free wall. Cardiac index was consistently higher from the RAA location (2.4 +/- 1.2 vs 2.1 +/- 0.91. min-1 m-2 at 85 bpm, 2.71 +/- 1.4 vs 2.35 +/- 1.11. min-1 m-2 at 100 bpm and 2.94 +/- 1.5 vs 2.61 +/- 1.41. min-1 m-2 at 120 bpm, P < 0.05). CONCLUSION: Stimulation from the RAA was superior to stimulation from the right atrial free wall with respect to left ventricular filling and cardiac output. Compared with stimulation from the right atrial free wall, RAA pacing resulted in an increase of 10-15% in cardiac output.

Aged↗

Regression of warfarin-resistant left atrial appendage thrombus after ablation of atrial fibrillation and permanent pacing.

Atrial fibrillation is the most common rhythm disturbance and can also occur in absence of true cardiac disease. However, also in these cases, it can generate left atrial appendage thrombi with systemic embolic potential. A regular and well conducted anticoagulant therapy with dicoumarol derivatives, as indicated in these patients, is not always successful. We report the case of a patient with lone atrial fibrillation and a left atrial appendage thrombus resistant to anticoagulant therapy with warfarin, which disappeared after catheter ablation of atrial fibrillation by electrical disconnection of the pulmonary veins, restoration of sinus rhythm and dual-chamber pacemaker implantation.

Anticoagulants↗

Evaluation of left atrial appendage stasis in patients with atrial fibrillation using transesophageal echocardiography with an intravenous albumin-contrast agent.

To assess stasis in the left atrial appendage in patients with atrial fibrillation and to identify patients at increased risk for thromboembolism, we performed transesophageal echocardiography with an intravenous albumin contrast agent (Albunex) in 25 patients with atrial fibrillation and in 22 patients in sinus rhythm. We demonstrated that the absence of opacification in the left atrial appendage after Albunex administration implies a high risk of left atrial thrombus and cardiogenic thromboembolism.

Adult↗

Large gradient across a partially ligated left atrial appendage.

The left atrial appendage is frequently ligated during mitral valve surgery to decrease the future risk of embolic events. The postoperative detection of a partially occluded left atrial appendage has previously been reported with the use of transesophageal echocardiography. We describe an unusual case in which Doppler echocardiography demonstrated a remarkably high-velocity jet emanating from a partially ligated left atrial appendage.

Echocardiography, Transesophageal↗

Left atrial appendage dysfunction in chronic nonvalvular atrial fibrillation is significantly associated with an elevated level of brain natriuretic peptide and a prothrombotic state.

The study tested the hypothesis that left atrial appendage (LAA) dysfunction in nonvalvular atrial fibrillation (NVAF) correlates with a prothrombotic state, and investigated whether the plasma natriuretic peptides are marker of LAA dysfunction in NVAF. Sixty-seven patients underwent transthoracic and transesophageal echocardiography. The left ventricular fractional shortening, left atrial diameter (LAD), LAA flow velocity and the grade of spontaneous echo contrast (SEC) were determined. The plasma concentrations of atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), D-dimer, and thrombin-antithrombin III complex (TAT) were measured. The patients were divided into 2 groups according to LAA flow velocity: group I (LAA velocity <20 cm/s) and group II (LAA velocity > or = 20cm/s). The SEC score, D-dimer, TAT, BNP and LAD were significantly increased in group I. Based on simple linear regression analysis, SEC score (r=-0.638), LAD (r=-0.493), D-dimer (r = -0.485), BNP (r = -0.463), TAT (r = -0.455) and age (r = -0.314) were inversely correlated with LAA flow velocity. Multivariate analysis showed that SEC score (p = 0.0014) and plasma BNP level (p=0.0075) were independent negative predictors for LAA flow velocity. In conclusion, LAA dysfunction is associated with a prothrombotic state, and the plasma BNP concentration may serve as a determinant of LAA function in NVAF.

Aged↗

Percutaneous closure of the left atrial appendage.

Patients with atrial fibrillation (AF) are at high risk of stroke. More than 15% of all strokes are due to atrial fibrillation. So far anticoagulation is the treatment of choice with a risk reduction of almost 70%. On the other hand, anticoagulation has many side effects such as intracranial or gastrointestinal hemorrhage. Closing the left atrial appendage (LAA) might be an alternative in patients who cannot take anticoagulation treatment due to contraindications or conditions in which the hazard of hemorrhage is greater than the potential clinical benefit. The PLAATO system (Percutaneous Left Atrial Appendage Transcatheter Occlusion) is a new device to close the LAA by the catheter technique. The device consists of a self-expandable nitinol cage that is covered with ePTFE. It is delivered via a specially designed 12F transseptal sheath. Small anchors along the struts prevent the occluder from embolizing. After device implantation patients are placed on aspirin only. The results of the dog model and the first clinical experiences in humans have been very promising.

Aged↗

Right Atrial Thrombi and Depressed Right Atrial Appendage Function After Cardioversion of Atrial Fibrillation.

BACKGROUND: It has been shown that cardioversion of atrial fibrillation may result in left atrial chamber and appendage dysfunction and cause new thrombi in the left atrium. The aim of this prospective study was to investigate right atrial appendage function and assess the incidence of new right atrial thrombi after electrical cardioversion. METHODS: Transthoracic echocardiography was performed in 25 patients 4 h before and at 24 h and 7 days after electrical cardioversion to determine right and left atrial mechanical function (internal atrial defibrillation, n = 16; external electrical cardioversion, n = 9), as assessed by peak A wave velocities derived from the transtricuspid and transmitral velocity profiles. In addition, transesophageal echocardiography was performed 4 h before and 24 h after cardioversion to evaluate postcardioversion thrombus formation in the right and left atrial chambers and to assess right and left atrial appendage function. The degree of spontaneous echo contrast was noted, and peak emptying velocities of the appendages were measured before and after cardioversion. RESULTS: Peak emptying velocities of both the right atrial appendage (mean +/- SD, 0.23 +/- 0.1 vs 0.32 +/- 0.11 m/sec; P = 0.02) and the left atrial appendage (0.3 +/- 0.15 vs 0.4 +/- 0.15 m/sec; P = 0.01) were significantly lower 24 h after cardioversion compared with 4 h before cardioversion, respectively. The degree of spontaneous echo contrast increased in the left atrium after cardioversion from 1.0 +/- 1.2 to 1.9 +/- 2.1 (P = 0.02), and in the right atrium, it increased from 0.8 +/- 1.1 to 1.2 +/- 1.1 (P = 0.1) after cardioversion. Peak A wave transtricuspid velocity increased from 0.26 +/- 0.05 m/sec at 24 h to 0.38 +/- 0.06 m/sec (P = 0.001) after 7 days; respective values for transmitral peak A wave velocity were 0.39 +/- 0.15 and 0.54 +/- 0.16 m/sec (P = 0.009). No thrombi were found in either the right or left atrium before cardioversion. In two patients, new thrombi in the right atrium were detected 24 h after internal atrial defibrillation. Thrombi were located at the superior rim of the fossa ovalis in both patients with patent foramen ovale. Another patient had developed a thrombus in the left atrial appendage. CONCLUSIONS: Electrical cardioversion may not only cause left atrial chamber and appendage dysfunction and left atrial thrombi but also lead to depressed right atrial appendage function and the generation of new thrombi in the body of the right atrium.

Journal Article↗

Left atrial appendage flow in nonrheumatic atrial fibrillation : relationship with pulmonary venous flow and ECG fibrillatory wave amplitude.

OBJECTIVE: This study was conducted (1) to examine the relationship between left atrial appendage (LAA) flow velocity and pulmonary venous flow (PVF) variables during nonrheumatic atrial fibrillation (AF), and (2) to determine whether a reduction in LAA flow is reflected by the fibrillatory wave amplitude on the surface ECG. BACKGROUND: Although LAA Doppler echocardiographic signals provide information regarding the velocity and direction of flow only for a localized narrow sample, systolic PVF represents in part the global left atrial function, mainly relaxation. Controversy exists about whether the amplitude of fibrillatory waves recorded on the surface ECG correlates with LAA flow velocity during AF. MEASUREMENTS AND RESULTS: Thirty-three patients (20 men, 13 women; mean [+/- SD] age, 61 +/- 11 years) with nonrheumatic AF undergoing transthoracic and transesophageal echocardiography were studied. A correlation between LAA flow velocity and systolic PVF variables (peak systolic velocity, R: = 0.450, p = 0.009; velocity-time integral of systolic flow, R = 0.491, p = 0.004; systolic fraction of PVF, R: = 0.627, p < 0.0001) was observed. Patients with a low LAA flow profile (< 25 cm/s) had a reduced systolic PVF. Longer AF duration and the occurrence of moderate mitral regurgitation were related to reduced LAA flow. AF was subdivided into coarse (peak-to-peak fibrillatory amplitude > or = 1 mm) or fine (< 1 mm) in standard ECG lead V1. There was no association between the coarseness of AF and the LAA flow profile. CONCLUSION: In patients with nonrheumatic AF, a reduction in LAA flow velocity correlates with a reduction in systolic PVF. These hemodynamic changes are not reflected by the ECG fibrillatory wave amplitude.

Aged↗

Left atrial appendage emptying velocity does not predict postoperative atrial fibrillation in patients undergoing cardiopulmonary bypass.

BACKGROUND: Atrial fibrillation is a common complication of cardio-pulmonary bypass and improved pre-operative risk assessment could help guide prophylactic therapy. This study examined whether reduced left atrial appendage flow velocities measured by transoesophageal echocardiography pre-operatively in patients in sinus rhythm predicted development of postoperative atrial fibrillation. METHODS AND RESULTS: All patients who underwent transoesophageal echocardiography for clinical indications with measurements of left atrial appendage velocities within twelve months prior to cardio-pulmonary bypass were retrospectively identified. Postoperative records were reviewed and the patients divided into two groups based on the presence or absence of clinically significant atrial fibrillation during hospitalization following cardio-pulmonary bypass. Thirty-six patients (mean age 61.1 +/- 14.8 years, 18M/18F) were included in the study. The overall incidence of atrial fibrillation in the cohort was 17/36 patients (47%). Mean left atrial appendage emptying velocity was 50.8 +/- 23.3 cm/s2 (range 26-119) in the patients with sinus rhythm only and 41.5 +/- 16.7 cm/s2 (range 16-76), in the patients with postoperative atrial fibrillation (P=ns). CONCLUSIONS: In our patient population there was no significant difference in left atrial appendage emptying velocity measured by transoesophageal echocardiography in patients with and without postoperative atrial fibrillation. Pre-operative measurement of left atrial appendage emptying velocity cannot be relied upon to risk stratify patients prior to cardio-pulmonary bypass.

Atrial Appendage↗

Decreased left atrial appendage flow velocity with atrial fibrillation caused by negative inotropic agents: report of two cases.

Although pharmacological agents are frequently used to control ventricular rate or restore sinus rhythm of patients with atrial fibrillation (AF), there are no reports of the relationship between those agents and left atrial appendage (LAA) function. Two cases of a decrease in LAA blood flow velocity caused by negative inotropic agents are presented as an indication that negative inotropic agents are a risk factor for systemic thromboembolism with AF.

Atenolol↗

Histologic assessment of right atrial appendage myocardium in patients with atrial fibrillation after coronary artery bypass graft surgery.

Atrial fibrillation (AF) is a common complication after coronary artery bypass graft (CABG) surgery. Despite the prevalence of AF occurring after cardiac surgery, its pathophysiology is incompletely understood. Our previous study demonstrated that age and left atrial enlargement were independent predictors of postoperative AF. Accordingly, the purpose of this study was to determine whether cellular changes such as fibrosis and/or hypertrophy occurred in the atrium in patients who subsequently developed postoperative AF. Right atrial appendage tissue was obtained during atriotomy in patients undergoing elective CABG surgery. Quantitative assessment of atrial fibrosis was performed with Sirius red stain, and atrial cell diameter was measured with the HE stain. Linear regression, t test, chi2 test or Fisher exact test were used for statistical analysis. Sixty-one patients (mean age 71 +/- 8 years) were studied. Increasing age was significantly associated with fibrosis (beta 0.3, 95% CI: 0.06-0.55, p = 0.017). The amount of right atrial fibrosis tended to correlate with the incidence of postoperative AF (p = 0.08). Cell diameter was not significantly different between patients with versus without postoperative AF (p = 0.85). These results suggest that the age-related atrial fibrosis rather than cellular hypertrophy may be important in the pathogenesis of AF after CABG surgery and should be further investigated.

Aged↗

Morphological changes of the left atrial appendage after catheter ablation of atrial fibrillation.

INTRODUCTION: The left atrial appendage (LAA) has been proven to be the most important site of thrombus formation in patients with atrial fibrillation (AF). However, the information regarding the morphometric alteration of the LAA related to the outcome of AF ablation is still lacking. Thus, we evaluated the long-term changes of the LAA morphology in patients undergoing catheter ablation of AF using magnetic resonance angiography (MRA). METHODS AND RESULTS: Group 1 included 15 controls without any AF history. Group 2 included 40 patients with drug-refractory paroxysmal AF. They were divided into two subgroups: group 2a included 30 patients without AF recurrence after pulmonary vein (PV) ablation. Group 2b included 10 patients with late recurrence of AF. The LAA morphology before and after (20 +/- 11 months) ablation was evaluated by three-dimensional MRA. The group 2 patients had a larger baseline LAA size (including the LAA orifice, neck, and length) and less eccentric LAA orifice and neck. After the AF ablation, there was a significant reduction in the LAA size in the group 2a patients, and the morphology of the LAA neck became more eccentric during the follow-up period. In group 2b, the LAA size increased and no significant change in the eccentricity of the orifice and neck could be noted. CONCLUSIONS: The morphometric remodeling of the LAA in the AF patients could be reversed after a successful ablation of the AF. Progressive dilation of the LAA was noted in the patients with AF recurrence. These structural changes in the LAA may play a role in reducing the potential risk of cerebrovascular accidents.

Atrial Appendage↗

Left atrial appendage contractile function in atrial fibrillation. Influence of heart rate and cardioversion to sinus rhythm.

BACKGROUND: A high incidence of embolic phenomena is associated with atrial fibrillation (AF) and the left atrial appendage (LAA) is frequently the source of the emboli. Thrombus formation may be due to stasis within the fibrillating and inadequately emptying LAA. Because LAA emptying in AF may be the result of mechanical compression by the adjacent left ventricle, it is possible that left ventricular diastolic filling duration will importantly influence passive emptying of the LAA. We hypothesized that the magnitude of emptying of the LAA in AF is related to the duration of left ventricular diastolic filling which is determined by the ventricular response rate in AF. OBJECTIVE: The objective of our study was to determine the relationship of ventricular response rate in AF to LAA emptying and to assess the influence of sinus rhythm and heart rate on LAA emptying immediately after direct current cardioversion to sinus rhythm. METHODS: To study this, we used transesophageal echocardiography to measure LAA ejection fraction ([LAAmax-LAAmin]/LAAmax x 100%) and evaluated its relationship to left ventricular response rate (VRR) in 26 patients with AF (mean age, 65 +/- 7 [1 SD] years). RESULTS: There was a strong inverse relationship between LAA ejection fraction and VRR in AF (r = -0.73; p < 0.001). LAA ejection fraction during AF was 26 +/- 10%, and immediately after successful cardioversion, it increased to 46 +/- 12% (p < 0.001). However, during sinus rhythm there was no relationship between LAA ejection fraction and VRR (r = 0.06; p = NS) in the subgroup of patients who were successfully converted to sinus rhythm. There were poor relationships between LAA ejection fraction and peak transmitral flow velocity (r = -0.41; p = NS) or pulmonary venous flow velocity (r = -0.03; p = NS) in AF. CONCLUSION: These results indicate that the magnitude of LAA emptying in AF is strongly and inversely influenced by ventricular rate. Direct current cardioversion to sinus rhythm is associated with an increase in the magnitude of LAA emptying that is not influenced by heart rate. The magnitude of LAA emptying may be an important factor in the formation of thromboemboli in AF. The extent to which controlling the VRR in chronic AF will prevent stasis and LAA thrombus formation remains to be determined.

Aged↗