Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “WELDING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Comparison of fibrin glue, laser weld, and mechanical suturing device for the laparoscopic closure of ureterotomy in a porcine model.

PURPOSE: We evaluated fibrin glue, laser welding, and a mechanical suturing device (Endo-Stitch) as alternatives to standard laparoscopic suturing with a free needle. METHODS: In 14 pigs, 22 linear proximal ureterotomies were closed laparoscopically with one of 4 different methods: fibrin glue, laser welding, Endo-Stitch suture placement (4-0 polyglactin), and free-needle suture placement (4-0 polyglactin). The ureterotomy was left open in 6 ureters. Acute leakage was tested by instillation of methylene blue. After 12 weeks, the ureters were assessed with radiography, ex-vivo pressure-flow studies, bursting pressures, and histology. RESULTS: All alternative closure techniques were more rapid than free-needle suturing, and less frequently allowed acute leakage. Closure with fibrin glue yielded significantly higher flow rates than control, whereas the other closure techniques yielded flow rates similar to that of unclosed ureters. All alternative closure methods demonstrated histological evidence of healing that were superior to free-needle suturing. In multifactorial analysis, leakage at the ureterotomy site was the factor most significantly associated with subsequent poor ex-vivo flow characteristics. CONCLUSIONS: All of the alternative laparoscopic ureteral closure methods compared favorably with standard free-needle suturing. Fibrin glue produced better radiographic findings, flow characteristics, and histology, suggesting that it currently has the most promise as an alternative or adjunct to laparoscopic suturing. Development of alternative laparoscopic techniques is ongoing, however, and thus the current state-of-the-art techniques used in this study may well be supplanted by other technologies in the future.

Animals↗

Osseointegration for welded and cast prostheses: presentation of two cases.

The author describes two cases of full dental arches with only a few natural teeth in place that were treated with multi-dimensional, osseointegrated implants. The former case utilized the technique of titanium casting of the caps on natural teeth and on implants, with intra-oral welding of the caps to the implants. In the latter case, the techniques of welding and casting differ.

Crowns↗

Magnetic field from spot welding equipment--is the basic restriction exceeded?

A point measurement of the magnetic field (MF) near a typical spot welding machine showed that the magnetic flux density was above the ICNIRP reference level. To investigate if the basic restrictions were exceeded, the induced body currents in a full 3D human model were calculated. It was found that at an operator position of 34 cm away from the machine the maximum induced current density was below the ICNIRP basic restriction. But if the operator was closer to the machine, the basic restriction was exceeded. An important finding of the present article is that the basic restriction can be exceeded although the MF spatially averaged over the whole body is well below the reference level.

Humans↗

Health problems among operators of plastic welding machines and exposure to radiofrequency electromagnetic fields.

To study possible medical effects of high radiofrequency radiation (RF), 113 Swedish men and women were studied by means of a structured interview and rating of subjective symptoms. A test session was included in order to examine coordination and muscular function of the hands. A neurological test concerning two-point discrimination (2-PD) was also done. As referents, 23 women, sewing machine operators and assembly workers, were chosen, interviewed and likewise tested. Exposure measurements were taken of the RF fields around the welding machines. The present Swedish ceiling value of 250 W/m2 for the equivalent power density was exceeded in more than 50% of the machines. The highest leakage fields, both for electric and magnetic fields, were found near machines used in factories for ready-made clothing, which gave a high exposure to the hands. Irritative eye symptoms were reported by 23% of the men and 40% of the women. A group of 27 persons was selected for a clinical eye examination and checked by photographs, and nine persons had modest conjunctivitis. A high prevalence of numbness in hands, especially among women, was found. A significantly impaired 2-PD was found in the exposed women as compared to the referent group. The pregnancy outcome for 305 female plastic welders during 1974-1984 did not show any significant differences with the Swedish average concerning malformation or prenatal mortality.

Adult↗

Development and utilization of a new simple assay for DNA-protein crosslinks as a biomarker of exposure to welding fumes.

A new method for DNA-protein crosslinks involving selective precipitation of DNA containing crosslinked proteins by K+ sodium dodecyl sulfate was utilized in the peripheral white blood cells of 21 male metal arc welders and in 26 male controls of similar age and racial characteristics who were not exposed to welding fumes. DNA was quantitated by Hoescht fluorescence. Although the concentration of nickel and chromium in the peripheral blood was low and did not differ between subjects in the two groups, one-fourth of the welders had levels of DNA-protein crosslinks that were above the upper limit of the controls. Mean crosslink values were 1.85% (+/- 1.14) among the welders and 1.17% (+/- 0.46) among the controls, a 58%, statistically significant difference (P = 0.01). Thus, many welders appeared to be burdened with an excess of DNA-protein crosslinks suggesting exposure to crosslinking agents and, possibly, a detectable biologic effect of potential genotoxic consequences.

Biomarkers↗

Exposure to welding fumes and chronic renal diseases, a negative case-referent study.

It was observed that some patients with glomerulonephritis or interstitial nephritis were welders. A hypothesis that welding fumes were an occupational hazard was put forward and initiated the following case-referent study. 143 cases were defined as living males, age 25 to 65 years, with renal disease which caused renal biopsy from 1976-1982. Three population-based referents for each case were selected from the national register of the total population matched by sex, age and community. Exposure was assessed by means of a questionnaire. Only 7% of the cases and 12% of the referents did not answer the questionnaire. There were no differences in exposure rates between cases and referents, even if exposure restrictions were applied. The power of the case-referent study was high.

Adult↗

Spot-welded wire hooks as seating guides for resin-bonded castings.

A technique is described to assist in accurate positioning of cast metal, resin-bonded prostheses. The method is particularly useful for the recementation of castings but can also be used with new restorations. A piece of rectangular chrome alloy arch wire is annealed and spot-welded to the retainer. The wire is then adapted to lie over the incisal edge of the abutment tooth and forms a locating device during trying in and cementing of the restoration. The wire hook assists in the handling of the casting at chairside and is easily snapped off after cementation, leaving little finishing to be completed. The technique permits access to all of the marginal surfaces at cementation and offers certain advantages over existing alternative techniques.

Cementation↗

CO2 laser welding versus conventional microsuture repair in patch-graft urethroplasty.

This study evaluates the repair of urethral tissue using microsurgery and a combination of laser welding techniques. Using the rat as a model, a patch-graft urethroplasty was performed with either conventional microsuture repair, laser-assisted microsuture repair, or laser-assisted microsuture with protein solder. Repairs were assessed at various time periods (days 0, 1, 7, and 21). Analysis of success rate, bursting strength, histology, and operative time were completed. The laser with protein solder had the highest success rate at each time period and demonstrated advanced healing with the least amount of inflammation. Operative time was decreased by 30 percent using the laser. In conclusion, the laser solder repair was significantly better than either laser alone or conventional microsutures.

Animals↗

Cytogenetic studies of stainless steel welders using the tungsten inert gas and metal inert gas methods for welding.

Cytogenetic damage was studied in lymphocytes from 23 welders using the Tungsten Inert Gas (TIG), and 21 welders using the Metal Inert Gas (MIG) and/or Metal Active Gas (MAG) methods on stainless steel (SS). A matched reference group I, and a larger reference group II of 94 subjects studied during the same time period, was established for comparison. Whole blood conventional cultures (CC), cultures in which DNA synthesis and repair were inhibited (IC), and the sister chromatid exchange (SCE) assay were applied in the study. For the CC a statistically significant decrease in chromosome breaks and cells with aberrations was found for both TIG/SS and MIG/MAG/SS welders when compared with reference group II. A non-significant decrease was found for the corresponding parameters for the two groups of welders when compared with their matched referents. A statistically significant negative association was found between measurements of total chromium (Cr) in inhaled air and SCE, and a weaker negative correlation with hexavalent Cr (Cr(VI)) in air. In conclusion, no cytogenetic damage was found in welders exposed to the TIG/SS and MIG/MAG/SS welding fumes with low content of Cr and Ni. On the contrary, a decline in the prevalence of chromosomal aberrations was indicated in the TIG/SS and MIG/MAG/SS welders, possibly related to the suggested enhancement of DNA repair capacity at slightly elevated exposures.

Adult↗

Occupational urticaria from welding polyurethane.

An urticarial reaction associated with high fever developed in a welder on four occasions while he was welding steel profiles filled with polyurethane. The fumes emitted during pyrolysis of polyurethane and inhaled by the patient probably caused the urticarial reaction. Provocation tests with two pyrolysis products, 4,4-diphenylmethane diisocyanate and 4,4-diaminophenylmethane, were negative. This case demonstrates the difficulty in detecting the cause of urticaria induced by airborne chemicals.

Adult↗

Spot weld injuries of the hand.

Spot weld burns of the hand result in damage to structures deep to the skin by dissipation of heat locally causing extensive necrosis. This must be appreciated to optimize treatment.

Accidents, Occupational↗

Stainless steel welding and semen quality.

Questionnaire studies of patients from fertility clinics suggest that welders may have an increased risk of reduced semen quality. In this study, welders and nonwelders from the same plants were asked to provide blood, urine, and semen samples. Urine was analyzed for chromium and nickel, and for mutagenic activity and metal concentration; blood for metal concentrations, immunoglobulin G, total protein, and measures of genotoxicity in lymphocytes; and semen was evaluated by standard semen analysis. Results of the semen evaluation, presented here, showed no difference in semen quality between welders and nonwelders. Because the metal dust exposure of nonwelders in the plant may be higher than that in the general population, welders were also compared to referents not working in the metal industry. Again, no decrease in semen quality associated with welding was demonstrated.

Adult↗

Stratification of welding fumes and grinding particles in a large factory hall equipped with displacement ventilation.

The purpose of the study was to investigate the performance of displacement ventilation in a large factory hall where large components of stainless steel for paper, pulp and chemical industries were manufactured. The performance of displacement ventilation was evaluated in terms of concentration distributions of welding fumes and grinding particles, flow field of the supply air and temperature distributions. Large differences in vertical stratification patterns between hexavalent chromium (Cr(VI)) and other particulate contaminants were observed. The concentration of Cr(VI) was notably lower in the zone of occupancy than in the upper part of the factory hall, whereas the concentrations of total airborne particles and trivalent chromium (Cr(III)) were higher in the occupied zone than in the upper zone. The stratification of Cr(VI) had the same tendency as the air temperature stratification caused by the displacement flow field.

Air Pollution, Indoor↗

Flash welding of conducting polymer nanofibres.

The absorption of light by a material generates heat through non-radiative energy dissipation and exothermic photochemical reactions. In nanostructured materials, the heat generated through photothermal processes will be confined within the individual nanostructures when heat transfer to neighbouring nanostructures and the environment is slow. This leads to unprecedented photothermal effects that cannot be observed in bulk materials, especially when a strong, pulsed light source is used. Here we demonstrate an enhanced photothermal phenomenon with conducting polymer nanofibres in which a camera flash causes instantaneous welding. Under flash irradiation, polyaniline nanofibres 'melt' to form a smooth and continuous film from an originally random network of nanofibres. This photothermal effect can be used to form asymmetric nanofibre films, to melt-blend polymer-polymer nanocomposites rapidly and to photo-pattern polymer nanofibre films.

Microscopy, Electron↗

Evaluation of airborne lead in the welding working environment.

Manual and automatic welding machines (which use leaded alloys) are considered to be important sources of the emission of lead fumes into the general air of the working environment. Three workplaces at a television factory were selected for the present study, to determine the control class of the working unit. The concentrations of conventional measurements ("A" sampling points) were lower than the administrative control level (statutory standard of lead, 150 microg m(-3)), whereas the maximum concentration of 264.1 microg m(-3) ("B" sampling point) was higher at one working unit than the administrative control level. However, the control classes varied between class III (bad) and class I (good).

Air Pollution, Indoor↗

Aluminum welding fume-induced pneumoconiosis.

Chronic exposure to high concentrations of fumes during aluminum arc welding causes a severe pneumoconiosis characterized by diffuse pulmonary accumulation of aluminum metal and a corresponding reduction in lung function. Aluminum fume-induced pneumoconiosis is a rarely reported entity, of which the true incidence is unknown. We report the clinical, radiographic, microscopic, and microanalytic results of 2 coworkers, employed by the same aluminum shipbuilding facility, who died of complications from this disease. Scanning electron microscopy and energy dispersive x-ray analysis of the exogenous particle content in the lung tissue of these cases revealed the highest concentrations of aluminum particles (average of 9.26 billion aluminum particles per cm(3) of lung tissue) among the 812 similar analyses in our pneumoconiosis database. One patient had an original clinical diagnosis of sarcoidosis but no evidence of granulomatous inflammation.

Adult↗