Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Analysis of trace levels of sulfonamide and tetracycline antimicrobials in groundwater and surface water using solid-phase extraction and liquid chromatography/mass spectrometry.

A method has been developed for the trace analysis of two classes of antimicrobials consisting of six sulfonamides (SAs) and five tetracyclines (TCs), which commonly are used for veterinary purposes and agricultural feed additives and are suspected to leach into ground and surface water. The method used solid-phase extraction and liquid chromatography/mass spectrometry (LC/MS) with positive ion electrospray. The unique combination of a metal chelation agent (Na2EDTA) with a macroporous copolymer resulted in quantitative recoveries by solid-phase extraction (mean recovery, 98 +/- 12%) at submicrogramper-liter concentrations. An ammonium formate/formic acid buffer with a methanol/water gradient was used to separate the antimicrobials and to optimize the signal intensity. Mass spectral fragmentation and ionization characteristics were determined for each class of compounds for unequivocal identification. For all SAs, a characteristic m/z 156 ion representing the sulfanilyl fragment was identified. TCs exhibited neutral losses of 17 amu resulting from the loss of ammonia and 35 amu from the subsequent loss of water. Unusual matrix effects were seen only for TCs in this first survey of groundwater and surface water samples from sites around the United States, requiring that TCs be quantitated using the method of standard additions.

Chemistry Techniques, Analytical↗

Simultaneous determination of losartan, EXP-3174 and hydrochlorothiazide in plasma via fully automated 96-well-format-based solid-phase extraction and liquid chromatography-negative electrospray tandem mass spectrometry.

An automated, sensitive and high-throughput liquid chromatographic/electrospray tandem mass spectrometric (LC-MS/MS) assay was developed for the simultaneous determination of losartan (LOS), its major circulating metabolite EXP-3174 and hydrochlorothiazide (HCTZ) in human plasma. LOS and HCTZ coexist in the same drug formulation, and this is the first method that enables the simultaneous determination of both drugs along with the active metabolite of LOS. Since these drugs have different physicochemical properties, the employment of a liquid-liquid extraction (LLE) protocol was precluded. A fully automated solid-phase extraction (SPE) protocol, based on 96-well format plates, was used to isolate these compounds and furosemide (internal standard, IS) from plasma. Washing and elution steps were amended accordingly in order to minimize any matrix effect from components of the plasma without reducing the elution of the molecules of interest. The compounds were eluted from a C18 column and detected with an API 3000 triple-quadrupole mass spectrometer using negative electrospray ionization and multiple reaction monitoring (MRM). The assay was linear over the range 1.00-400 ng/mL for LOS and EXP-3174 and 0.500-200 ng/mL for HCTZ, respectively, when 200 microl of plasma was used in the extraction. The overall intra- and interassay variations were within acceptance limits. The analysis time for each sample was 4 min, and more than 300 samples could be analyzed in one day by running the system overnight. The assay was simple, highly sensitive, selective, precise, fast, and it enables the reliable determination of LOS, EXP-3174 and HCTZ in pharmacokinetic or bioequivalence studies after per os administration of a single tablet containing both drugs.

Antihypertensive Agents↗

Uniform solid-phase extraction procedure for toxicological drug screening in serum and urine by HPLC with photodiode-array detection.

In this HPLC-diode-array detection method for toxicological drug screening, a mixed-mode solid-phase extraction procedure is optimized for isolation of a broad range of drugs from serum and urine. Basic, neutral, and weakly acidic drugs are uniformly recovered. The extract from the solid-phase cartridge is readily injected to a reversed-phase HPLC column for separation by gradient elution. Unknown drugs and metabolites in urine and serum samples from acute drug poisoning cases are rapidly identified by matching their retention times and ultraviolet spectra with hundreds of reference compounds in the library. Urine metabolites of common toxicants from various medications and drugs of abuse are recorded, with their changes of retention times and ultraviolet spectra as related to their metabolic transformations. Glucuronide conjugates of common benzodiazepines, tricyclic antidepressants, and beta-blockers are examined directly without chemical or enzymatic hydrolysis. The system is reliable for diverse clinical investigations of drug overdoses, drug-induced psychoses, and substance abuse.

Blood Chemical Analysis↗

Coupling on-chip solid-phase extraction to electrospray mass spectrometry through an integrated electrospray tip.

We report the integration of solid-phase extraction (SPE) with mass spectrometry (MS) through an on-chip electrospray tip for sample precleaning and preconcentration. An in situ polymerized alkylacrylate-based monolithic column was used as the stationary phase for the on-chip SPE. Each microchip consists of two sets of microchannels and their respective integrated electrospray tips, with a common gold electrode. After the microchip was fabricated from cycloolefin polymer by hot embossing, thermal bonding, and annealing steps, a mixture of monomers and porogenic solvents was pumped into the microchannels and certain areas of the main microchannels were exposed to UV irradiation through a mask. The resulting porous monolithic beds that were polymerized from different compositions of the mixture were characterized by scanning electron microscopy. The microchip containing the monolithic column was then interfaced to an ion trap (IT) mass spectrometer by modifying a commercially available interfacing system. Makeup solution from the side channel was infused concurrently with the solution flowing into the main channel, and the mixture of these two solutions was sprayed into the MS orifice. Both the adsorption and elution of a pharmaceutical test compound, imipramine, to and from the on-chip SPE columns were monitored by MS. The potential application of this device for sample cleanup was demonstrated by pretreatment of urine samples spiked with imipramine.

Humans↗

Development of a solid phase extraction method for simultaneous determination of corticoids and tranquilizers in serum samples.

A simple and fast solid phase extraction (SPE) method allowing the preconcentration, clean-up, and subsequent separate elution of phenothiazines (chlorpromazine hydrochloride, acetopromazine, and propionylpromazine hydrochloride) and glucocorticoids (dexamethasone, betamethasone acetate, and phenylbutazone) from serum samples has been developed. Both fractions were separately collected and analyzed without any additional treatment by high performance liquid chromatography with UV-Vis. The performance of the complete procedure was satisfactory irrespective of the spiking level with recoveries in the range 64-85% for all analytes investigated but for phenylbutazone (20%). Repeatability, evaluated as the relative standard deviation, was globally better than 12%. LC-MS was used for final confirmation of the results.

Adrenal Cortex Hormones↗

Use of solid-phase extraction to eliminate interferences in the determination of mercury by flow-injection CV AAS.

Solid-phase extraction with two-step elution has been developed for effective elimination of copper and iron interference with mercury determination by flow-injection cold vapour atomic absorption spectrometry (CV AAS). Sodium tetrahydroborate(III) was used as reducing agent. Cation-exchanger Dowex 50Wx4 was applied for the sorption of mercury and both interfering ions. In the first step elution of Cu(II) and Fe(III) was performed using 0.5 mol L(-1) KF solution. Then mercury was eluted with 0.1% thiourea in 8% HCl. The detection limit (3 delta) for Hg(II) was 27 ng L(-1). The expanded uncertainty estimated for the whole procedure was about 6%. The accuracy of the proposed method was evaluated by determination of the recovery of known amount of mercury added to mineral, spring, and tap waters, and by analysis of a certified reference material BCR-144R (sewage sludge).

Journal Article↗

Determination of Zy 17617B in plasma by solid-phase extraction and liquid chromatography with automated pre-column exchange.

An automated chromatographic system, combining solid-phase extraction and automated pre-column exchange, is described for the routine determination of Zy 17617B at the pmol/ml level in human plasma. The sample extraction and elution onto the analytical column were performed automatically and concomitantly using a conventional liquid chromatographic apparatus equipped with a Merck OSP-2 on-line sample preparator. Validation data demonstrate the reliability of the method.

Antidiarrheals↗

Simple purification of recovered [18O]H2O by UV, ozone, and solid-phase extraction methods.

We have developed three methods for removing organic impurities as well as a solid-phase extraction (SPE) method for removing metallic and ionic impurities from recovered [18O]H2O. Preliminary experiments with [16O]H2O were used to determine the optimal purification conditions. These showed that UV irradiation rapidly (<4 h) eliminated low boiling point impurities such as acetonitrile and acetone with only a slight loss of mass. A combination of UV irradiation and purging with ozone removed high boiling point impurities such as ethanol and methanol more quickly than UV irradiation alone. UV irradiation followed by a SPE with [18O]H2O removed all organic and inorganic impurities. The purified [18O]H2O gave a saturation yield of 128.62+/-15.6 mCi/microA for [18F]fluoride and a 49.8+/-12.7% radiochemical yield for [18F]fluorodeoxyglucose.

Journal Article↗

Solid phase extraction procedure for urinary organic acid analysis by gas chromatography mass spectrometry.

We have developed a solid phase extraction procedure for the detection of organic acids by GC-MS using a strong anion exchange column (Sep-Pak Vac RC, Accell Plus QMA cartridge). Extraction efficiencies of 25 organic acids were established by analyzing standards in water based solutions. High extraction efficiencies (90 to 100%) were found for many of the compounds studied. We estimated the limit of detection for 48 organic acids and glycine conjugates. They were below 5 nmole with the exception of malonic and oxalic acids and mevalonic acid lactone. This method provides the advantage of higher recoveries for a wide range of compounds of interest and therefore can be a potential alternative to liquid-liquid extraction for organic acid screening. It is especially sensitive for the detection of some polar compounds, such as 3-OH-glutaric and N-acetylaspartic acids.

Acids↗

On-line coupling of size exclusion chromatography and capillary electrophoresis via solid-phase extraction and a Tee-split interface.

An on-line size exclusion chromatography (SEC)-solid-phase extraction (SPE)-capillary electrophoresis (CE) system using a Tee-split interface has been developed for the analysis of peptides in biological fluids. The SEC column fractionates the sample by molecular size and the low-molecular-weight fraction, which contains the peptides, is directed to a C(18) SPE microcolumn, where the peptides are trapped and concentrated. The SPE column is desorbed with 425 nL acetonitrile and the effluent is sent to the Tee-split interface, which hydrodynamically splits (1:40) the flow and, thus, allows appropriate injection of analytes into the CE system. The performance of the system is investigated by the analysis of enkephalins in cerebrospinal fluid (CSF). It is demonstrated that the SEC step efficiently removes potentially interfering proteins, permitting reproducible SPE and CE. The total system provides efficient separations of the enkephalins with plate numbers up to 100,000. Concentration limits of detection (S/N = 3) for the peptides are about 100 ng/mL for injection of 20 microL spiked CSF samples. Plots of enkephalin peak areas versus concentration showed good linearity over the 0.25-10 microg/mL range (R2 > or = 0.985). Repeatability of migration time and peak area was within 2% and 10% R.S.D., respectively.

Chromatography, Gel↗

Solid phase extraction--non-aqueous capillary electrophoresis for determination of metformin, phenformin and glyburide in human plasma.

Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.

Electrophoresis, Capillary↗

Determination of polycyclic aromatic hydrocarbons in waters by use of supercritical fluid chromatography coupled on-line to solid-phase extraction with disks.

The potential of supercritical fluid chromatography (SFC) coupled on-line to solid-phase extraction (SPE) with disks for determining sixteen different polycyclic aromatic hydrocarbons (PAHs) was assessed. A preliminary study of the chromatographic separation was conducted that led to the use of SPE coupled to SFC for improved detection limits. Disks of two different materials, i.e., C18 and polystyrene-divinylbenzene, were assayed in terms of the variables influencing the extraction step. C18 disks provided the best results, with detection limits ranging from 0.1 to 1.5 micrograms l-1. The ensuing method was applied to river and tap water with good repeatability and reproducibility, and no interference from the sample matrix.

Chromatography, Liquid↗

Study of applicability of various solid-phase extraction materials for sample handling in screening analysis of organic micropollutants in water.

At present, solid-phase extraction (SPE) has become an often preferred preconcentration technique in the screening for a wide range of organic micropollutants in water. A wide choice of materials available on the market makes SPE a suitable tool to cope with an increasing variability of organic compounds entering the hydrosphere. However, the interactions of various sorbent materials with compounds having different physico-chemical properties leads inevitably to large differences in preconcentration efficiency. The aim of this paper was to investigate the efficiency of preconcentration of selected organic compounds from aqueous solutions on various SPE materials. Simultaneously, the potential of newly emerging SPE procedures was compared to results of traditional liquid-liquid extraction methods. The group of 19 tested analytes was selected so as to represent different classes of organic compounds which may occur in waters. The results obtained showed that most of the tested materials were suitable for sufficient preconcentration of a substantial part of the tested analytes. However, specific differences in recovery of one or more analytes were found for almost each sorbent even in the case when the materials had similar composition. This behaviour clearly indicates the need for a thorough testing of capabilities of any SPE material intended for the use in a wide range screening method for the identification of unknown organic micropollutants in water.

Organic Chemicals↗

Solid-phase extraction and LC-MS analysis of pyrrolizidine alkaloids in honeys.

Strong-cation-exchange, solid-phase extraction of pyrrolizidine alkaloids and their N-oxides from honey samples was followed by reduction of the N-oxides and subsequent analysis of total pyrrolizidine alkaloids using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. A limited survey of 63 preprocessing samples of honey, purposefully biased toward honeys attributed to floral sources known to produce pyrrolizidine alkaloids, demonstrated levels of pyrrolizidine alkaloids up to approximately 2000 parts per billion (ppb) in a sample attributed to Echium plantagineum. Up to 800 ppb pyrrolizidine alkaloids was detected in some honeys not attributed by the collector to any pyrrolizidine alkaloid-producing floral source. No pyrrolizidine alkaloids were detected in approximately 30% of the samples in this limited study, while some honeys showed the copresence of pyrrolizidine alkaloids from multiple floral sources such as E. plantagineum and Heliotropium europaeum. In addition, retail samples of blended honeys (with no labeling to suggest that pyrrolizidine alkaloid-producing floral sources were used in the blends) have been shown to contain up to approximately 250 ppb pyrrolizidine alkaloids.

Chromatography, High Pressure Liquid↗

Determination of linear alkylbenzene sulfonates and their polar carboxylic degradation products in sewage treatment plants by automated solid-phase extraction followed by capillary electrophoresis-mass spectrometry.

Linear alkylbenzene sulfonates (LAS) were determined by solid-phase extraction (SPE), followed by capillary electrophoresis and mass spectrometry detection (CE-MS). The linear range of the proposed method varied from 33 to 316 and from 215 to 2057 micrograms L-1, depending on the compound, with limits of detection ranging from 4.4 to 23 micrograms L-1 when 200 ml of wastewater were preconcentrated. The analysis and confirmation of the polar carboxylic metabolites of LAS, the sulfophenyl carboxylic acids (SPC) was also achieved, and their presence was detected in both, influent and effluents of the sewage treatment plant (STP). [M - H]- ions were used for CE-MS confirmation and quantification. CE-MS diagnostic ions were the same ones used in LC-electrospray (ESI)-MS and corresponded to m/z 297, 311, 325 and 339 for C10LAS, C11LAS, C12LAS and C13LAS, respectively. For SPC identification, diagnostic ions corresponded to m/z 215 to 369 (with 14 mass unit steps) for C2 to C13SPC, respectively. LAS were determined in wastewater samples of the influent and effluent of three sewage treatment plants (STP), two of them using biological treatment with secondary settlement and receiving mainly domestic wastewater whereas one of the plants was operated with physiochemical treatment and received mainly industrial wastewater. The concentration levels of total LAS varied from 1000 to 1900 micrograms L-1 in the influents of STP, whereas in the effluents the concentrations varied from 125 to 360 micrograms L-1.

Journal Article↗

Antimony speciation by inductively coupled plasma mass spectrometry using solid phase extraction cartridges.

A novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations. The detection limit was 1 ng L(-1) antimony. Factors affecting the separation and detection of antimony species were investigated. Acidification of samples led to partial or complete retention of Sb(V) on C8 cartridge. Foreign ions tending to complex with Sb(III) or APDC did not interfere with the retention behavior of the Sb(III)-APDC complex. This method has been successfully applied to antimony speciation of various types of water samples.

Antimony↗

Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline.

A molecularly imprinted polymer solid phase extraction (MISPE) method combined with flow-injection chemiluminescence (FI-CL) for the determination of residual tetracycline (TC) in fish samples is presented. The molecularly imprinted polymer (MIP) of TC was synthesized and particles of this MIP were packed into a polytetrafluoroethylene (PTFE) tube, which was connected into the sampling loop of an eight-way injection valve and served as the MISPE column for on-line selective adsorption of TC. The eluent (CH3CN : HNO3 (0.01 mol L(-1)) = 4 ratio 1, v ratio v) was used for extracting the adsorbed TC, which could be detected by its good enhancing effect on the CL reaction between Ce(iv) and rhodamine B. The CL intensity is linear to TC concentration in the range from 4 x 10(-9) to 4 x 10(-7) g mL(-1). The detection limit is 1 x 10(-9) g mL(-1) (3 sigma) and the relative standard deviation is 2.4% (n = 9). The conditions of preconcentration, extraction and CL reaction were carefully studied. The selectivity experiment shows that the selectivity and sensitivity of the CL method could be improved greatly when MIP was used as a recognition material in SPE. However, the MISPE column interacted indiscriminately with oxytetracycline (OTC) with a 49 +/- 2% binding. An intermediate differential pulsed elution (DPE) step using 3% acetic acid as eluent was employed to remove OTC and other interfering substances. The proposed MISPE-CL method has been applied successfully to the determination of TC in fish samples. At the same time, the binding characteristics of the polymer to tetracycline were evaluated by batch and dynamic methods.

Animals↗

Use of automated solid-phase extraction equipment for the determination of isoniazid in milk.

The possibility of using automated equipment for solid phase extraction of isoniazid from milk has been investigated. This equipment provides two noteworthy advantages: it shortens the time of analysis and avoids SPE column plugging, stabilizing flow rates. After setting the correct programme on software controlling the equipment, some validation parameters have been determined to obtain recovery and repeatability data. The mean recovery for spiked samples resulted in the range 75-95%, the standard error ranged from -5 to -20% while the RSD varied from 2 to 22%. Therefore the method can be considered reliable and fast.

Animals↗