Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Slit Lamp”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Ultrasound biomicroscopy for detection of breaks and detachment of the ciliary epithelium.

PURPOSE: To elucidate details of the pathologic changes in the ciliary epithelium associated with atopic dermatitis and blunt ocular trauma. METHODS: We examined prospectively 52 eyes of 42 patients with detachment of the nonpigmented epithelium of the ciliary body associated with atopic dermatitis and blunt ocular trauma. All the eyes underwent ultrasound biomicroscopic examination as an adjunct to binocular indirect ophthalmoscopy with scleral depression and slit-lamp biomicroscopy. RESULTS: Of the 52 eyes examined, high-resolution ultrasound biomicroscopy and conventional diagnostic methods (that is, binocular indirect ophthalmoscopy with scleral depression and slit-lamp biomicroscopy) disclosed breaks at the anterior vitreous base border in 40 eyes, at the pars plicata of the ciliary body in 27 eyes, and at the white midline (that is, the line located in the mid pars plana anterior to the anterior vitreous base border) in four eyes. In 40 eyes the breaks at the anterior vitreous base border could be detected with conventional methods but in only 28 eyes could they be diagnosed with ultrasound biomicroscopy. Conversely, in 27 eyes the breaks of the pars plicata could be observed with ultrasound biomicroscopy but in 25 eyes they were detected with conventional methods. In 21 eyes with breaks only at the anterior vitreous base border, the detachment of the nonpigmented ciliary epithelium was limited posterior to the white midline. In all 27 eyes with the nonpigmented ciliary epithelial detachment anterior to the white midline, the breaks of the pars plicata were identified by ultrasound biomicroscopy. CONCLUSION: Because of the minimum deformation of the globe during examination, ultrasound biomicroscopy contributed to the diagnosis of detailed structural change in the ciliary body associated with atopic dermatitis and blunt ocular trauma in relation to the white midline. In our sample of patients, the white midline may act as a barrier against ciliary nonpigmented epithelial detachment, and detachment of the nonpigmented epithelium anterior to the white midline indicated the presence of the pars plicata break in most cases.

Ciliary Body↗

Corneal subepithelial opacities associated with inappropriate contact lens care.

PURPOSE: To report two cases of corneal subepithelial opacities, which may be related to improper lens care by the patients. METHODS: Slit-lamp examination and monitoring of contact lens care procedures. RESULTS: Two female patients experienced similar symptoms of soreness, blurring, and red eyes after wearing soft contact lenses. Slit-lamp examinations demonstrated numerous subepithelial opacities in the central cornea. Both patients used the same kind of cleaner (MiraFlow) inappropriately, which resulted in the possibility of residual cleaner remaining in the lenses. The symptoms and signs gradually subsided after discontinued use of soft contact lens and application of topical steroid. CONCLUSIONS: Residual MiraFlow in soft contact lenses may result in corneal subepithelial opacities.

Adult↗

Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses: two-year results of a randomized trial.

PURPOSE: To compare intensity of posterior capsule opacification (PCO) between the 1-piece and 3-piece haptic designs of an open-loop hydrophobic acrylic intraocular lens (IOL). DESIGN: A randomized, patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS: Fifty-two patients with bilateral age-related cataract (104 eyes). METHODS: Each patient had cataract surgery in both eyes and received a 1-piece Acrysof IOL in one eye and a 3-piece Acrysof IOL in the fellow eye. Follow-up examinations were at 1 week, 1 month, 6 months, 1 year, and 2 years. Patients were examined at the slit lamp, visual acuity (VA) was determined, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The intensity of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. MAIN OUTCOME MEASURE: Posterior capsule opacification score (scale, 0-10). RESULTS: There was no significant difference between IOL styles in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. One year postoperatively, the amount of regeneratory PCO was higher for the 1-piece Acrysof eyes (image analysis software score: 1.3) than for the 3-piece Acrysof eyes (score: 0.9; P = 0.002). However, 2 years postoperatively, there was no significant difference between the 2 IOL styles (1-piece: 1.5; 3-piece: 1.3; P = 0.3). Neodymium:yttrium-aluminum-garnet capsulotomy was not performed in the study. CONCLUSION: One year postoperatively, the 1-piece Acrysof showed slightly more regeneratory PCO than the 3-piece Acrysof. However, 2 years postoperatively, the barrier effect of the 1-piece design was comparable to that of the 3-piece haptic design, with low PCO intensity.

Acrylic Resins↗

Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.

PURPOSE: Comparison of the intensity of posterior capsule opacification (PCO) between a silicone intraocular lens (IOL) and a hydrophobic acrylic IOL, both of them 3-piece and open-loop and having truncated optics with sharp edges. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred six eyes of 53 patients with age-related bilateral cataract. METHODS: Each patient had cataract surgery in both eyes and received a silicone IOL in one eye and a hydrophobic acrylic IOL in the fellow eye. Follow-up examinations were at 1 and 3 years after surgery. The patients were examined at the slit lamp, visual acuity (VA) was assessed, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The amount of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. Data of 56 eyes of 28 patients, who were examined at each follow-up, were analyzed. MAIN OUTCOME MEASURE: Posterior capsule opacification intensity at 3 years as measured with automated image analysis. RESULTS: At 1 and 3 years after surgery, PCO did not differ between the silicone (1.6 and 1.9 [image analysis scores, 0-10 scale], respectively) and acrylic IOLs (1.7 and 2.2) (P > 0.24). Furthermore, there was no significant difference in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. In each group, one neodymium:yttrium-aluminum-garnet (YAG) laser capsulotomy was performed during the entire study duration. CONCLUSION: Silicone and hydrophobic acrylic are similarly effective in inducing the PCO-inhibiting effect of a rectangular, sharp optic edge. Three years after surgery, the PCO intensity and the YAG rate were low with both IOL models.

Acrylic Resins↗

LASIK in patients with rheumatic diseases: a pilot study.

PURPOSE: To investigate the safety of LASIK in patients with a known history of controlled rheumatic diseases. DESIGN: Retrospective consecutive observational clinical study. PARTICIPANTS: Forty-two eyes (22 patients) known to have had a history of rheumatic diseases underwent LASIK. All patients had a history of controlled rheumatic diseases, including rheumatoid arthritis, systemic lupus erythematosus, dermatomyositis, scleroderma, ankylosing spondylitis, psoriatic arthritis, inflammatory bowel disease, arthritis, or Behçet's disease. METHODS: Assessments were made preoperatively and at 1, 3, and 6 months postoperatively and included visual acuity (VA), refraction, keratometric readings, slit-lamp biomicroscopy, and corneal topography. All the patients underwent LASIK. Postoperative treatment included a topical steroid-antibiotic combination. MAIN OUTCOME MEASURES: Visual acuity, refraction, keratometric readings, and slit-lamp biomicroscopy findings at 1, 3, and 6 months postoperatively. RESULTS: LASIK was performed uneventfully on all patients. The mean pre-LASIK spherical equivalent (SE) was -5.39+/-2.25, and the sixth month postoperative SE was -0.15+/-0.38 diopters (D) (P<0.001). Uncorrected VA 6 months after the LASIK procedure was 20/25. Enhancement procedures were performed in 6 of 42 eyes (14.3%) at variable times after the primary procedure. Postoperative follow-up showed development of a moderate degree of dry eye syndrome in 4 eyes (9.5%). Corneal haze, melting, flap, or interface complications were not observed in any of the study eyes. CONCLUSIONS: In this small series, we found good outcomes when correcting refractive errors using LASIK in selected patients with controlled rheumatic diseases. In this series, a favorable postoperative visual outcome was obtained with no operative or postoperative vision-threatening complications.

Adult↗

In vitro and in vivo effects of polyhexamethylene biguanide against herpes simplex virus infection.

PURPOSE: The differential diagnosis of Acanthamoeba keratitis frequently includes herpes simplex viral keratitis. Previous in vitro studies with chlorhexidine, a drug with antiacanthamoebic action, have suggested concomitant antiviral activity against herpes simplex virus. We tested another related antiacanthamoebic compound, polyhexamethylene biguanide (PHMB), to determine its activity against herpes simplex virus (HSV) in vitro and herpes simplex viral keratitis in vivo. METHODS: Equal aliquots of HSV-1 (McKrae) strain were incubated in a medium with no PHMB or with PHMB at 0.01, 0.02, or 0.05 for 5 min at 35 degrees C and the inoculum was then titered on a monolayer of E-2 cells (human corneal fibroblasts). Monolayers were examined on consecutive days and the percentage of plaque reduction was calculated. Eighteen rabbits (36 eyes) were inoculated with HSV-1 McKrae strain (10(5) pfu [plaque-forming units]/per eye). Rabbits were divided into three groups and treatment was initiated on day 3 postinfection. Group I received trifluorothymidine, group II received PHMB, and group III received artificial tears, each given five times daily in both eyes until day 10. Daily corneal swabbing to detect viral shedding and slit-lamp examination every 3 days were performed during this period. RESULTS: In vitro studies showed 62.5, 100, and 100% plaque reduction with 0.01, 0.02, and 0.05% PHMB, respectively. Slit-lamp examination of the rabbit corneas revealed faster resolution of dendrites in animals in group I treated with trifluorothymidine. Virus was not recoverable from corneal swabs in nine of 10 rabbits in group I by day 5, but all animals in groups II and III were still shedding HSV through day 8. CONCLUSION: Although PHMB has potent in vitro activity against HSV, it was not an effective treatment in the in vivo rabbit model of primary HSV keratitis at the concentration commonly used for treatment of Acanthamoeba infection. This suggests that 0.02% PHMB will not provide adequate antiherpetic coverage with treatment of keratitis of undetermined etiology in which the clinical differential diagnosis includes both herpes simplex and Acanthamoeba.

Administration, Topical↗

A new method for retroillumination photography of cataractous lens opacities.

We studied a new method for photographing cataractous lens opacaities by retroillumination. The slit-lamp microscope was modified with an adaptor to eliminate the specular reflection from the corneal surface. We construcated two kinds of adaptors for the Zeiss and Goldmann-type slit-lamp microscopes. The cataractous lens opacities were recorded both on Ektachrome color films and Tri-X monochromatic films. In using a monochromatic film, an orange filter was inserted in the illumination beam in order to increase the image contrast. The results were satisfactory with high resolution and good contrast. We found the new device to be useful clinically for evaluating the progressive changes of cataractous lens opacities.

Cataract↗

Human fibrin tissue glue for corneal lamellar adhesion in rabbits: a preliminary study.

PURPOSE: To evaluate the use of a human fibrin tissue adhesive in the adherence of corneal lamellar flaps in rabbit eyes. METHODS: Corneal flaps were made using a microkeratome in both eyes of six New Zealand white rabbits. In the right eyes, the flaps were glued with fibrin tissue adhesive; in the left eyes, flaps were allowed to heal without adhesive (controls). All eyes were treated with antibiotics and steroids once daily for 10 days. Slit-lamp biomicroscopy was performed 1 and 10 days after surgery. The rabbits with surviving flaps were euthanized and the corneas obtained for histopathologic examination 10 days after surgery. RESULTS: Slit-lamp examinations showed no interface deposits and no other signs of corneal toxicity. Histologically, a few inflammatory cells were seen in both the experimental and control eyes, and microscopic gapping and tissue debris were observed in three of the six control eyes. CONCLUSIONS: Human fibrin tissue glue was well tolerated in these eyes, with no or minimal corneal toxicity. Further studies are needed to determine the tensile strength of the adhesive bond in the cornea.

Animals↗

Corneal epithelial keratitis in herpes zoster ophthalmicus: "delayed" and "sine herpete". A non-contact photomicrographic in vivo study in the human cornea.

PURPOSE: To investigate the origin of corneal epithelial keratitis occurring without accompanying herpes zoster ophthalmicus (HZO) cutaneous rash. METHODS: Corneal epithelial lesions in seven patients (four with a history of classical HZO with cutaneous rash, one of herpes zoster oticus, and two with no history of herpes zoster, were examined with the slit lamp and photographed by non-contact in vivo photomicrography. The findings were compared with lesions in classical acute HZO. Polymerase chain reaction (PCR) was done in three patients. RESULTS: Slit lamp appearance, morphology at higher magnification, and kinetics of the lesions were indistinguishable from classical acute HZO. PCR was positive for varicella-zoster virus DNA in all three samples. CONCLUSIONS: The findings strongly suggest that HZO typical corneal epithelial lesions occurring in the absence of cutaneous rash are in fact recurrent episodes of virus shedding.

Aged↗

The prevalence of primary open-angle glaucoma in Japanese: the Tajimi Study.

PURPOSE: To assess the prevalence of primary open-angle glaucoma (POAG) and its association with intraocular pressure (IOP) in Tajimi City in central Japan. DESIGN: A cross-sectional epidemiologic study in a defined population. PARTICIPANTS: Subjects randomly selected from the population older than 40 years in Tajimi City. INTERVENTION: Each subject underwent a screening examination comprised of an interview and ophthalmic examinations, including measurement of IOP by a Goldmann applanation tonometer, central corneal thickness (CCT), slit-lamp examination, fundus photography, and a screening visual field test using frequency doubling technology. When ocular diseases were suspected, the subjects were referred for definitive examination. During the definitive examination, slit-lamp examination, IOP measurement, a visual field test using Humphrey Field Analyzer 30-2 SITA Standard program (Humphrey Instruments, San Leandro, CA), optic disc and fundus examination, and gonioscopy were performed and stereoscopic disc photographs were obtained. A diagnosis of glaucoma was made based on optic disc appearance, perimetric results, and other ocular findings. MAIN OUTCOME MEASURES: Prevalence of POAG, mean IOP, and mean CCT. RESULTS: Of 3870 eligible people, 3021 (78.1%) participated in the study. The estimated prevalence of POAG in the population older than 40 years was 3.9% (95% confidence interval [CI]), 3.2%-4.6%). The prevalence of cases of POAG with IOP levels of 21 mmHg or less was 3.6% (95% CI, 2.9%-4.3%), whereas the prevalence for those with IOP levels of more than 21 mmHg was 0.3% (95% CI, 0.1%-0.5%). The average IOP for eyes with POAG was 15.4+/-2.8 (standard deviation) in the right eye (n = 115) and 15.2+/-2.8 mmHg in the left eye (n = 115), which was significantly higher than that of nonglaucoma subjects (14.5+/-2.5 in the right eye; n = 2759; P = 0.0004; and 14.4+/-2.6 mmHg in the left eye; n = 2757; P = 0.0026). The mean CCT of POAG eyes with IOP levels of 21 mmHg or less was 518+/-29 (n = 109) in the right eye and 519+/-29 microm (n = 110) in the left eye, levels that were not significantly different from that of nonglaucoma eyes (520+/-32 microm [n = 2690]; and 522+/-32 microm [n = 2692]; P>0.05). CONCLUSIONS: The prevalence of POAG in this population was 3.9%. In 92% patients with POAG, the IOP was 21 mmHg or less.

Adult↗

Two patterns of opacity in corneal dystrophy caused by the homozygous BIG-H3 R124H mutation.

PURPOSE: To investigate the opacity pattern in corneas with an Arg124His (R124H) homozygous mutation of the BIG-H3 gene. METHODS: Slit-lamp examination was performed on eight patients with corneal dystrophy resulting from a genetically confirmed BIG-H3 R124H homozygous mutation. The birthplace of each patient also was determined. RESULTS: Slit-lamp examination disclosed two types of opacity patterns in corneas with the BIG-H3 R124H homozygous mutation. Type I (n = 4) is a spot-like opacity present in the anterior stroma in which the lesions are confluent. Type I is the same pattern that previous reports have shown to be caused by the BIG-H3 R124H homozygous mutation. The type II corneal opacity pattern (n = 4) is a reticular opacity in the anterior stroma with round translucent spaces. Type II opacity has not been reported previously in association with any corneal dystrophy. The patients with the type I opacity do not share a common birthplace; however, interestingly, the patients with the type II opacity traced their origin to Tottori prefecture in western Japan. CONCLUSION: The BIG-H3 homozygous R124H mutation induces the development of two distinct patterns of corneal opacity, the recognition of which can establish an accurate diagnosis of corneal dystrophy caused by the homozygous BIG-H3 R124H mutation independent of genetic analysis. In addition, genetic factors or circumstantial influences other than the gene responsible for the corneal dystrophy may influence the pattern of corneal opacity.

Adult↗

Modulation of selenite cataract by the flavonoid fraction of Emilia sonchifolia in experimental animal models.

The purpose of the study was to investigate the role of flavonoids from Emilia sonchifolia (ES) on the progression of selenite-induced cataract. The antioxidant property of the flavonoids isolated from ES was assessed by measuring its capacity to inhibit superoxide production and serum oxidation in vitro in comparison with quercetin. Based on these experiments, an in vivo study was conducted to evaluate the modulatory effects of the flavonoids against selenite cataract. Cataract was induced by a single subcutaneous injection of sodium selenite (4 mg/kg body weight). The treatment group received flavonoids from ES (1 mg/kg) and this was compared with the quercetin treated group. Lens opacification was monitored by a slit lamp microscope and classified into six stages. Activity of the antioxidant enzymes - superoxide dismutase and catalase - and the level of lipid peroxidation products thiobarbituric acid reacting substances and reduced glutathione were studied. Slit lamp examination showed that the flavonoid fraction from ES could modulate the progression of cataract. Activities of superoxide dismutase, catalase and reduced glutathione were found to be increased in the ES treated groups, while thiobarbituric acid reacting substances were decreased compared with the selenite-induced group. The results suggest that flavonoids from ES can modulate lens opacification and oxidative stress in selenite-induced cataract.

Animals↗

Follow-up ophthalmologic examinations in children with Kawasaki's disease.

We recalled 15 patients who had had Kawasaki's disease with documented bilateral conjunctival injection but who had not undergone slit-lamp examinations during the acute phase of the illness. Although anterior uveitis has been found in the acute phase of Kawasaki's disease, results of the follow-up studies (including slit-lamp examination, visual acuity testing, and assessment of pupillary reaction, muscle balance, and intraocular pressure) were normal in all 14 children.

Adolescent↗

Detection of corneal epithelial defect through amniotic membrane patch by fluorescein.

PURPOSE: To demonstrate the usefulness of fluorescein dye to detect a corneal epithelial defect through an amniotic membrane patch in 4 cases. PATIENTS AND METHOD: Two patients with painful bullous keratopathy, 1 patient with total limbal deficiency, and 1 patient with acute chemical burn underwent surgeries in conjunction with amniotic membrane as patch. Postoperatively, slit-lamp biomicroscopic examination with and without fluorescein staining was performed. RESULTS: The status of epithelialization, ie, corneal epithelial defect on either denuded corneal stroma or amniotic membrane graft, was indiscernible by slit-lamp biomicroscopy through the amniotic membrane patch. Nevertheless, it could be detected by fluorescein staining, especially after saline rinse, in all 4 cases. CONCLUSIONS: Fluorescein staining permits clinicians to avoid prematurely removing the amniotic membrane patch during the treatment of a persistent corneal epithelial defect.

Administration, Topical↗

Flow cytometric study of anterior chamber aqueous humor after neodymium: yttrium aluminum garnet laser iridotomy.

Laser iridotomy is a safe and effective treatment of pupillary-block glaucoma; however, increased intraocular pressure (IOP) may occur after the procedure. A flow cytometric study of aqueous humor was done 1.5 hours after neodymium: yttrium aluminum garnet laser iridotomy in 20 eyes. This sensitive and precise method did not reveal an apparent correlation between the degree of postoperative IOP spike and the amount of inflammatory cells or cellular debris induced by laser iridotomy. Although slit-lamp examination showed many "cells" in the anterior chamber in most after laser iridotomy, DNA histography found only scanty chromatin coating cells. We believe the so-called cells observed using slit-lamp biomicroscopy might not all be real cellular aggregates but rather aggregates of protein or fibrin in some situations.

Acute Disease↗

The Oxford Clinical Cataract Classification and Grading System.

A composite slit-lamp based system for the clinical classification and grading of cataract is described. Cataract features are classified morphologically, and individual features are graded by comparison with standard diagrams mounted adjacent to the slit-lamp. Attention has been paid to relevant aspects of measurement theory, with equal interval steps between the grades. The image degrading effect of the cataract is assessed using a 'resolution target projection ophthalmoscope'. The method may be used in conjunction with photographic and image analysing techniques.

Cataract↗

The value of conjunctival biopsy in childhood cystinosis.

Cystinosis is frequently presented with cystine storage in the cornea and conjunctiva, and the diagnosis can be established by slit-lamp examination. It can also be confirmed by electron microscopy of a conjunctival biopsy. The present paper reports on a 16-month-old boy with Fanconi's syndrome, in whom the slit-lamp examination did not show crystal deposits of cystine in the conjunctiva. The ultrastructural study of the conjunctival biopsy demonstrated polygonal crystals within double membrane-limited organelles located in fibroblasts. Similar crystals were subsequently found in a kidney biopsy. We therefore think that conjunctival biopsy is a valuable diagnostic tool prior to performing renal biopsy, even in cases with negative findings by ophthalmologic examination.

Conjunctiva↗

In-vivo response to free electron laser incision of the rabbit cornea.

BACKGROUND AND OBJECTIVE: We analyzed the in vivo ocular response to corneal incisions made by Medical Free Electron Laser (MFEL) as a function of scan rate and incision depth. Additionally, we compared biomicroscopy, optical coherence tomography (OCT), and light microscopy as ocular response diagnostic tools. STUDY DESIGN/MATERIALS AND METHODS: Rabbit corneas were incised with pulsed MFEL radiation at 2.94 microm wavelength, scalpel incisions or focal cautery treatment were used as controls. The MFEL beam scan rate ranged from 0.2 to 1.0 mm/second. Ocular effects were monitored for 2 hours postoperatively using OCT and slit lamp examination. Ocular tissue was fixed for light microscopic examination. RESULTS: Anterior chamber fibrin formation correlated with MFEL incision depth. Slower scan rates resulted in deeper incisions and greater fibrin formation. OCT was better than slit lamp biomicroscopy at identifying fibrin attachments. OCT and light microscopy proved to be excellent companion technologies. CONCLUSIONS: Deep corneal incisions in the rabbit produced by the MFEL resulted in fibrin formation in the anterior chamber.

Animals↗