Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Characterization of biomembranes by spectral ellipsometry, surface plasmon resonance and interferometry with regard to biosensor application.

Phospholipid bilayers with transport proteins and antigen/antibody interfaces are considered to be suitable biosensor systems. The quality of such membranes or interfaces depends on the properties of the layers. Optical methods have proved to be an appropriate tool for characterizing those layers in situ and in a non-destructive manner. Two systems with potential for biosensor applications are characterized by some of these methods: phospholipid bilayer membranes spread from vesicle solution and protein-antigens both adsorbed on planar solid support. The results of spectral ellipsometry, surface plasmon resonance (SPR) and spectral interferometry are compared with respect to quality of characterization, expenditure of sample preparation and measurement, and time resolution. The phospholipid membranes adsorbed show a relatively low refractive index and a relatively high thickness. Bruggeman effective medium approximation is used to calculate the effective layer thickness. This result is compared to SPR measurements. A correlation between thickness and vesicle concentration may be detected. Further, the test protocol of an immunoassay is examined by spectral interferometry and SPR. Thicknesses determined are compared to results obtained by applying spectral ellipsometry. The data measured by ellipsometry are in agreement with the molecular dimensions of the immunoglobulins. Differences between details can be explained by physical considerations.

Biosensing Techniques↗

Determination of the refractive index increment (dn/dc) of molecule and macromolecule solutions by surface plasmon resonance.

An automated method for dn/dc determination using a surface plasmon resonance instrument in tandem with a flow injection gradient system (FIG-SPR) is proposed. dn/dc determinations of small molecule and biomolecule, surfactant, polymer, and biopolymer solutions with precision around 1-2% and good accuracy were performed using the new method. dn/dc measurements were also carried out manually on a conventional SPR equipment with similar accuracy and precision. The FIG-SPR instrument is inexpensive and could be easily coupled to commercially available SPR and liquid chromatography instruments to obtain several properties of the solutions, which are based on measurements of refractive index.

Animals↗

Resonant mirror biosensor detection method based on yessotoxin-phosphodiesterase interactions.

Yessotoxin (YTX) is a generic name for a group of lipophilic compounds recently discovered and chemically characterized. Association measurements were done in a resonant mirror biosensor. The instrument detects changes in the refractive index and/or thickness occurring within a few hundred nanometers form the sensor surface where a molecule is attached. We used aminosilane surfaces where phosphodiesterase 3',5'-cyclic-nucleotide-specific from bovine brain (PDEs) was immobilized. Over this immobilized ligand different amounts of YTX were added and typical association curve profiles were observed. These association curves fit a pseudo-first-order kinetic equation where the apparent association rate constant (k(on)) can be calculated. The value of this constant increases with YTX concentration. From the representation of k(on) versus YTX concentration we obtained the association rate constant (k(ass)) 248+/-40 M(-1)s(-1) and the dissociation rate constant (k(diss)) 9.36 x 10(-4)+/-1.72 x 10(-4)s(-1). From these values the kinetic equilibrium dissociation constant (K(D)) for YTX-PDEs association can be calculated. The value of this last constant is 3.74 x 10(-6)+/-8.25 x 10(-8)M YTX. The PDE-YTX association was used as a method suitable for determination of the toxin concentration in a shellfish sample. The assay had sufficient sensitivity and can be used on simple shellfish extracts.

3',5'-Cyclic-AMP Phosphodiesterases↗

Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

OBJECTIVE: To characterize the ultrasound fields produced by a cohort of transducers from a single manufacturer via hydrophone and Schlieren technology. DESIGN: Descriptive study. SETTING: Measurement laboratory. PARTICIPANTS: Seven same-model ultrasound transducers from a single manufacturer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Effective radiating area (ERA), total power, spatial average intensity (SAI), beam nonuniformity ratio (BNR), and Schlieren beam widths at 1.0 and 3.3 MHz. RESULTS: Values for ERA (1.0 MHz range, 3.62-4.38 cm(2); 3.3 MHz range, 3.74-4.76 cm(2)), total power (1.0 MHz range, 5.0-5.6 W; 3.3 MHz range, 4.7-5.7 W), SAI (1.0 MHz range, 1.2-1.4 W/cm(2); 3.3 MHz range, 1.0-1.5 W/cm(2)), and BNR (1.0 MHz range, 2.79-5.85; 3.3 MHz range, 2.51-4.56) fell within manufacturer's specifications and U.S. Food and Drug Administration (FDA) regulations. Schlieren analysis showed significantly larger beam widths at 3.3 MHz compared with 1.0 MHz and a large degree of variability in the ultrasound fields generated by the different transducers. There were no significant correlations between beam widths and ERA values. CONCLUSIONS: ERA and total power values in a test cohort exist within a range that met FDA regulations. Individual variability in ERA and total power resulted in 50% variability in SAI. This variability may help explain previous reports of heating differences between transducers.

Acoustics↗

Articular cartilage depicted at optimized angular position of Laue angular analyzer by X-ray dark-field imaging.

Using 36.0 keV X-ray from synchrotron radiation, we examined the optimized angular position of Laue analyzer for depicting articular cartilage of an intact human finger by X-ray dark-field imaging. The surface of articular cartilage was depicted clearly by adopting the offset angle of 0.04 arcsec to lower angular side to the analyzer whilst the contour of articular cartilage was delineated clearly at the other angular positions of the analyzer within the width of the rocking curve.

Anisotropy↗

A method for studying insoluble immune complexes.

Two variants of a method for determining the average composition of insoluble immune complex particles (IICP) are described. The first variant is based on measuring the specific turbidity (the turbidity per unit mass concentration of the dispersed substance) and the average size of IICP determined from dynamic light scattering (DLS). In the second variant, the slope of the logarithmic turbidity spectrum (wavelength exponent) is used instead of DLS particle size. Both variants allow the average biopolymer volume fraction to be determined in terms of the average refractive index of IICP. The method is exemplified by two experimental antigen+antibody systems: (i) lipopolysaccharide-protein complex (LPPC) of Azospirillum brasilense Sp245+rabbit anti-LPPC; and (ii) human IgG (hIgG)+sheep anti-hIgG. We have found that IICP can be modeled by incompact porous particles that contain about 30% of biopolymer substance and 70% of buffer.

Antibodies, Anti-Idiotypic↗

A dynamic phase microscopic study of optical characteristics of individual chloroplasts.

Dynamic phase microscopy (DPM) allows the monitoring of optical path difference (or phase height), h(x,y,t) approximately integraln(x,y,z,t)dz, an integral refractive index projection of the medium, n(x,y,z,t), in optically transparent biological specimens at high spatial and temporal resolutions. In this study, DPM was used for the analysis of fluctuations in the optical characteristics of individual bean chloroplasts in various metabolic states. A "phase image" of an individual chloroplast, which represents a three-dimensional plot of the "phase height", was obtained for the first time, and the frequency spectra of the fluctuations of h(x,y,t) were investigated. The fluctuation patterns, i.e., the intensity and the frequency spectra of phase height fluctuations in bean chloroplasts (Class B) were found to depend on their metabolic state. Under conditions of noncyclic (or pseudocyclic) electron transport, the fluctuations displayed characteristic frequencies in the range of 0.25-0.6 Hz and were space-time-correlated in the chloroplast domains with the cross sizes of approximately 2 microm. The fluctuation intensity decreased in the presence of uncouplers (nigericin and valinomycin, 20 microM). A stronger (in comparison with 20 microM valinomycin) effect of 20 microM nigericin suggests that the light-induced generation of the transmembrane pH difference (DeltapH) makes the main contribution to the increment of space-correlated fluctuations of h(x,y,t). Studies of chloroplasts incubated in media of various osmolarity (50-500 mM sucrose) have shown that structural changes in thylakoids are among other factors responsible for phase height fluctuations.

Chloroplasts↗

Approaches to improving the biocompatibility of porous perfluoropolyethers for ophthalmic applications.

Porous perfluoropolyether (PFPE) membranes for ophthalmic applications were prepared with a zwitterion monomer, 3-[[2-(methacryloxy) ethyl](N,N-dimethyl)ammonio]-propane-1-sulphonate, copolymerized in weight ratios of 0-10%. The polymer samples were assessed for a range of physical properties, including equilibrium water content, bovine serum albumin permeability, transparency, refractive index and the ability to support corneal epithelial cell and tissue attachment, growth and migration. In vitro assessment of the polymers using bovine corneal epithelial cells and tissue showed that a zwitterion incorporation level of between 0% and 6% in the PFPE membranes supported the migration of an intact sheet of epithelial tissue without compromising epithelial cell attachment and growth, with 4-6% being the optimal level for these properties. Binding patterns of the cell adhesion glycoprotein fibronectin were also found to reflect the cell and tissue response. Effective nutrient permeability, refractive index and optical transparency were also maintained by the porous PFPE polymers containing this concentration of zwitterionic monomer. The presence of amounts of zwitterion greater than 6% was inhibitory to both tissue migration and cell growth and was associated with increased optical haze. These results demonstrated that it is possible to achieve the potential for increased biocompatibility in zwitterion-containing PFPE polymers without compromising existing beneficial characteristics.

Animals↗

Photoelectric response of polarization sensitive bacteriorhodopsin films.

Polarization sensitivity is introduced into oriented bacteriorhodopsin (BR) films through a photochemical bleaching process, which chemically modifies the structure of the purple membrane by breaking the intrinsic symmetry of the membrane-bound BR trimers. The resulting photovoltage generated in an indium-tin oxide (ITO)/BR/ITO detector is found to be anisotropic with respect to cross-polarized probe beams. A model, based on the polarization dependent photoselection of the BR molecules qualitatively explains the photochemical bleaching process and the observed anisotropic response. The effect reported here can be used to construct a polarization sensitive BR-based bio-photoreceiver.

Anisotropy↗

Measurement of film thickness up to several hundreds of nanometers using optical waveguide lightmode spectroscopy.

Up to now, most studies based on optical waveguide lightmode spectroscopy (OWLS) were dedicated to thin adlayers, assumed to be isotropic and homogeneous, for which data analysis was based on an approximation of the mode equations valid when the thickness is small with respect to the wavelength of the laser light. The aim of the present paper is to extend the use of OWLS to thicker deposited layers (up to approximately 400 nm). Both the simplified and extended models are compared in terms of optical parameters, i.e. the refractive index nA, the thickness dA, and the optical mass QA, for experimental data obtained with polyelectrolyte multilayer films. The deviation of these parameters can be quite large when derived using the simplified model instead of the extended model. This observation evidences that OWLS is well suited for the study of "thick" films if the appropriate model is applied to the data analysis.

Algorithms↗

A sensitivity comparison of optical biosensors based on four different surface plasmon resonance modes.

Current surface plasmon resonance (SPR) modes based on the attenuated total reflection (ATR) method can broadly be categorized as: conventional SPR, long-range SPR (LRSPR), coupled plasmon-waveguide resonance (CPWR), and waveguide-coupled SPR (WCSPR). Although the features of optical biosensors are dependent upon their particular SPR mode, a common requirement for all biosensors utilized for biomolecular interaction analysis (BIA) is a high degree of sensitivity. The current paper presents a theoretical analysis and comparison of the sensitivity and resolution of these four types of SPR biosensors when employed in three of the most prevalent detection methods, namely angular interrogation, wavelength interrogation, and intensity measurement. This study develops a detailed understanding of the influences of various biosensor design parameters in order to enhance the sensitivity and detection limit capabilities of such devices.

Computer Simulation↗

Detection of insulin-antibody binding on a solid surface using imaging ellipsometry.

Imaging ellipsometry (IE) was used to detect the binding of insulin to its antibody on a solid surface. The modification of a gold surface with 11-mecaptoundecanoic acid (11-MUA), the adsorption of protein G, and antibody immobilization onto the protein G layer were confirmed by surface plasmon resonance. Ellipsometric images and ellipsometric angles of the surface antibody were acquired using the IE system by off-null ellipsometry. Ellipsometric images of antigen binding to the antibody were acquired, and their mean optical intensities estimated. Changes in mean optical intensity indicated that the detection range for insulin was from 10 ng/ml to 100 microg/ml.

Antigen-Antibody Complex↗

Metal clad leaky waveguides for chemical and biosensing applications.

Novel metal clad leaky waveguide (MCLW) sensor devices have been developed for sensing applications. These chips are designed to confine the light in a low refractive index waveguide that encompasses the chemically-selective layer, maximising the overlap between the optical mode and the chemistry, thus improving the sensitivity. In this work, a thin metal layer was inserted between the substrate and the thick waveguide layer, increasing the reflectivity of the waveguide/metal interface and decreasing the light lost at each of reflection in the leaky mode, which in turn increases the propagation distance. The device has been used for a range of biosensing applications, including the detection of organophosphoros pesticides. The limit of detection for paraoxon, based on absorbance detection, was calculated to be 6 nM. Refractive index detection was demonstrated by monitoring the change in the out-coupled angle resulting from the binding of protein A to anti-protein A immobilized on agarose. The sensor was also used for detecting the quenching of the fluorescence of an acid-base sensitive ruthenium complex immobilized within the sol-gel and with glucose oxidase enzyme. The limit of detection for glucose was 3 microM. The advantage of using the metal layer in the MCLW was that an electrical potential could be applied to accelerate the diffusion of the analyte to the immobilised antibody, which resulted in a shortened analysis time and a reduction in non-specific binding.

Biosensing Techniques↗

Optical microsensors for pesticides identification based on porous silicon technology.

A simple and low cost optical sensor, based on porous silicon nanotechnology, has been used to detect and quantify the presence of atrazine pesticide in water and humic acid solutions. In both cases, a well defined optical signal variation can be registered, even at low concentration as 1 ppm. The phenomenon can be ascribed to the capillary infiltration of liquid into the pores, which changes the average refractive index of the structure. Due to the resonant cavity enhanced operation of the proposed sensors, very low detection limits can be reached.

Atrazine↗

Bacteria detection using disposable optical leaky waveguide sensors.

Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR).

Bacillus↗

Development of infrared optical sensor for selective detection of tyrosine in biological fluids.

In this paper, a new and simple evanescent wave type of infrared biosensor is described for the selective detection of tyrosine in biological fluids. This sensor is based on the formation of copper complexes between the sensing phase and tyrosine. To demonstrate that this principle was applicable to the selective detection of tyrosine, a proline-modified sensing phase was synthesized on the surface of the internal reflection elements. This sensing phase was saturated with copper ions to allow it to interact with tyrosine units in aqueous solution through the formation of stable proline-Cu2+-tyrosine complexes. Tyrosine exhibits a unique spectral feature in its absorption band at 1515 cm-1. This band significantly differs from those of other amino acids and provides a further method for the discrimination of tyrosine. By investigating the signals from 12 amino acids, only three amino acids, each containing a phenyl group, could be sensed selectively by this sensing phase. Based on the unique absorption of tyrosine located at 1515 cm-1, tyrosine can be selectively detected. To perform quantitative analyses of tyrosine using this sensing phase, a theoretical working equation was developed and correlated with the experimental data. The analytical results indicated that the developed equations do explain and predict the detection behaviors of the proposed sensing scheme. Using the optimal conditions, the regression coefficients for standard curves of tyrosine recorded in the region of concentrations below 600 microM were higher than 0.996 under either equilibrium or non-equilibrium conditions. Detection limit of tyrosine when using this method was ca. 3 microM.

Biosensing Techniques↗

Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli.

A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated by common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The sensor is able to detect active growth of Escherichia coli cells within 1 h which is significantly faster than any conventional plating method which requires at least 24 h. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of active bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing by adding antibiotics to the nutritive layer.

Biosensing Techniques↗

Dual polarization interferometry size and density characterisation of DNA immobilisation and hybridisation.

Investigation of nucleic acid interactions was performed using dual polarization interferometry, a novel approach to elucidating molecular interactions. This paper presents a preliminary study of adsorption of single stranded DNA onto functionalised silicon oxynitride, compared with covalent linkage, and avidin-biotin immobilisation. The effect of probe concentration on hybridisation efficiency was also examined. We found that increasing the electrolyte concentration resulted in a decrease of adsorbed DNA and that capture of a biotinylated duplex DNA on an adsorbed avidin layer resulted in four times fewer molecules per cm(2) than for duplex DNA covalently bound via an amine end terminal. The rate of thickness increase of a biotin probe layer on an adsorbed avidin capture layer increased 10-fold when the probe concentration was increased from 0.1 microM to 1 microM. The close grafting density of the higher concentration probe meant that the immobilised probes were unavailable for hybridisation.

Biosensing Techniques↗