Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “NOISE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Noise and related events in a neonatal intensive care unit.

The purposes of this study were to explore noise distribution, its timing, and sources of peak noise in the neonatal intensive care unit (NICU) of a University Hospital in Southern Taiwan. Two surveys on noise distribution and peak noise of the warmer bed were conducted. Noise at radiate heated beds located in the central sites of two areas, one near (Area A) and the other away from (Area B) the nursing station, were measured continuously for one week using an electronic sound-meter. Peak noise with a sound level of > 65 on the A-weighted decibel scale (dBA) and associated sources were recorded for 48 hours. Monitoring periods of peak noise consisted of a weekday and a day on the weekend randomly selected for Area A. Results showed that mean noise levels at the warmer bed in Areas A and B were 62 and 61.4 dBA on average. In over 70% of the total observation time for both areas the sound levels were > 59 dBA. The noise intensity was particularly high between 8 a.m. and 4 p.m. The noise level on the weekend was lower than that on weekdays. During the 48-hour observation period, 4994 peak noises were recorded. Eighty-six percent of these peak noises were within ranges of 65-74 dBA and 90% were human-related factors. The primary non-human related source was monitor alarms. Additionally, peak noises occurred primarily during the 8-11 a.m. and 2-4 p.m. hours on the weekdays and weekends. These results indicate that modifications of staff behavior, care procedures, and apparatus may reduce the noise levels in the NICU.

Data Collection↗

Cardiovascular and autonomic response to environmental noise during sleep in night shift workers.

Polysomnograph, beat-by-beat heart rate and blood pressure were monitored in night shift workers exposed to environmental and laboratory noise events during day sleep. The study was carried out in a sleep laboratory. Subjects were nine young, healthy female night shift workers. Recorded noises from trucks, civilian aircraft, low altitude military aircraft and tones were presented at 55, 65, and 75 L(Amax). Sleep stage, heart rate, and systolic and diastolic blood pressures before and immediately after onset of noise events were compared. Spectral analyses of heart rate and blood pressure variabilities were used to compare sympathetic and parasympathetic nervous tone in 10-min. intervals containing noise and quiet. Heart rate was responsive to noise level but not noise type. Blood pressure increased primarily to sounds of sudden onset. Noise-induced awakening and alpha EEG responses were related to BP increase. Increase in HR was greatest when subjects were awakened by noise or already awake. Spectral analysis of BP variabilities indicated increased sympathetic vascular tone due to noise. Similar analyses of HR data indicated no noise effect. No habituation to noise was apparent over three consecutive sleep sessions. It was concluded that over the range of noise levels used, heart rate responds to noise level during sleep; blood pressure to sounds of sudden onset. Spectral analysis of blood pressure variabilities is a sensitive measure of autonomic nervous response to environmental noise and should also be studied in subjects sleeping at home.

Adult↗

Subjective annoyance caused by indoor low-level and low frequency noise and control method.

The influence of low-level noise has not been widely noticed. This paper discovered that low-level and low frequency noise (A-weighted equivalent level Leq < 45 dB) causes higher probability of subjective annoyance. The fuzzy mathematic principle was applied to deal with the threshold level of subjective annoyance from noise in this study; there is preferable relationship between the indoor noise and noise annoyance at low frequency noise level. Study indicated at the same centered noise level, the change of annoyance probability is mainly caused by the change of the frequency spectrum characteristic of the indoor noise. Under low noise level environment, without change of the medium-low frequency noise, the slight increase of medium-high frequency noise level with the help of noise sheltering effect can significantly reduce the noise annoyance. This discovery brings a new resolution on how to improve the environmental quality of working or living places. A noise control model is given in this study according to the acoustic analysis.

Attitude↗

Effects of noise on pure-tone thresholds in blackbirds (Agelaius phoeniceus and Molothrus ater) and pigeons (Columba livia).

Blackbirds and pigeons were trained to detect tones in quiet and in broadband noise by using positive-reinforcement techniques. In Experiment 1, thresholds in noise were obtained in blackbirds as a function of both tone frequency and noise intensity for a pulsed noise masker (noise gated on and off with tone). For blackbirds, critical ratios (the ratio of the power of the just-detectable tone in noise to the power of the noise masker) obtained in pulsed noise showed no consistent relation to tone frequency. For pigeons, on the other hand, critical ratios obtained in continuous noise increased by about 3 dB/octave across their range of hearing, being similar to known critical ratio functions for cats and humans. In Experiment 2, critical ratios in blackbirds obtained with both continuous noise and pulsed noise were compared. Blackbird critical ratios were more stable in continuous noise and averaged 4 dB lower than critical ratios in pulsed noise. The blackbird critical ratio function obtained with continuous noise was similar to the known critical ratio function of another avian species, the parakeet. Thus, small birds appear to have atypical critical ratio functions, compared with pigeons and other vertebrates.

Animals↗

Sociopsychological factors affecting the human response to noise exposure.

Community noise is reported to be the most often mentioned undesirable neighborhood condition in a recent U.S. Census survey. Understanding community response to noise involves the measurement of a number of complex acoustic and nonacoustic variables and establishing the chain of relationships between physical exposure, perception, annoyance, and acceptability responses and finally complaint behavior. The perceived loudness of a noise is the most important acoustic parameter influencing annoyance and complaints, and the simple dBA unit can be used to integrate spectral characteristics of complex sounds in community studies. Although energy averaging such as Leq or Ldn can be used to describe multiple noise exposures over time, the variable trade-off relationships between number and level of exposures are somewhat obscured by such summary measures. However, they are still the best available descriptors and, until more accurate ones are developed, can be used to measure community noise environments. Perception of an identical noise exposure can vary according to the physiological noise sensitivity of a person and the activity context in which the noise is heard. Although the acoustic quality of the noise itself usually explains about 10 to 25 per cent of the variability in annoyance responses, sociopsychological variables measured in field studies account for 35 to 50 per cent of the variations in human annoyance responses. Three of the most important nonacoustic factors are the connotative fear effects of the noise signal, the feeling that those responsible for the noise are misfeasant in not reducing the noise, and the feeling that harmful health effects are produced by the noise. When residents report great fear, a high misfeasance, and marked health effects, about 90 per cent report a high annoyance level whether their noise exposure level is above 90 Ldn or 65 to 70 Ldn. In contrast, if the feelings are a low fear level, a low degree of misfeasance, and minimal health effects, only 3 to 10 per cent give high annoyance responses. Complaint behavior, although based on intensity of annoyance, is modified by a number of other sociopsychological factors and often is an unreliable indicator of an environmental problem.

Attitude↗

[Chronic noise exposure and the cardiovascular system in aircraft pilots].

The aim of this study was to assess whether pilots are exposed to any risk of effects on the cardiovascular apparatus, whether chronic exposure to noise can be a risk factor for this occupation, the importance of intensity, length and type of exposure to noise, and if any relationship exists between audiometric deficits and cardiovascular effects. The study comprised 416 pilots subdivided into two groups according to the different levels of chronic exposure to noise, and a group of 150 control subjects not exposed to noise. The results showed: a) a higher prevalence of hypertension, nearly always diastolic, and of ECG abnormalities in the group of pilots of turboprop aircraft compared to jet plane pilots and to controls (p < 0.005 and p < 0.01 respectively); b) a higher prevalence of orthostatic hypotension in the two groups of pilots than in the controls (p < 0.05); c) a higher prevalence of hypertension with audiometric deficit compared to hypertension without audiometric deficit both in the more heavily and in the less heavily exposed to noise (p < 0.05), and a higher prevalence of hypertension with audiometric deficit in subjects exposed to higher levels of noise compared to hypertension with deficit but in subjects with lower levels of exposure (p < 0.05); d) a higher prevalence of abnormalities of basal, maximum effort and recovery ECG in pilots exposed to higher noise intensity (p < 0.05); e) improved hypertensive response to ergometric test in pilots with basal hypertension; f) subjects with a maximal load up to 120 W belonged prevalently to the group exposed to more intense noise (p < 0.001), while those with maximal load up to 210 W (p < 0.001) belonged to the group exposed to less intense noise. Considering that pilots are comparable for traditional cardiovascular risk factors, including age, both within the group and with the controls, the results confirm 1) that pilots could be exposed to the risk of effects on the cardiovascular apparatus, 2) that noise could be one of the risk factors and that cardiovascular effects could be related to intensity, type and length of exposure, age being the same, 3) that vascular damage is often accompanied by hearing loss even if the response of the auditory apparatus is different from the response of the cardiovascular apparatus, 4) that the postural diminution of arterial blood pressure might be a sign of a cardiovascular effect of noise. Lastly, a higher hypertensive response in hypertensive pilots suggests that basal hypertension is not reversible. Also a longer exposure to noise seems to influence the cardiovascular apparatus, causing a decrease in the response to work loads due to a lower sympathetic adaptability. The altered response of sympathetic activity to the postural modifications in the more exposed subjects and the response to lower work loads in pilots exposed to more intense noise, suggests a hypothesis of catecholamine depletion and alteration of baroceptor sensitivity as a consequence of chronic sympathetic activation due to chronic exposure to noise.

Adult↗

Effect of a music intervention on noise annoyance, heart rate, and blood pressure in cardiac surgery patients.

BACKGROUND: Exposure to noise in a critical care unit may trigger a response by the sympathetic nervous system, thereby increasing cardiovascular work in patients recovering from cardiac surgery. OBJECTIVE: To investigate the effects of a music intervention given twice on the first postoperative day on noise annoyance, heart rate, and arterial blood pressure in subjects with high (n = 22) and low (n = 18) sensitivity to noise. METHODS: A prospective, quasi-experimental, repeated-measures design was used. Based on results of power analysis, the sample size was 40. Subjects were recruited preoperatively, and their sensitivity to noise was assessed. On the first postoperative day, repeated-measures data were collected on levels of noise annoyance and physiological variables during 15 minutes of baseline and 15 minutes of music intervention on two occasions. Subjects completed a follow-up questionnaire regarding their perceptions of the noise in the critical care unit and the music intervention. RESULTS: Repeated-measures analysis of variance showed that subjects had lower levels of noise annoyance during music intervention than at baseline. Heart rate and systolic blood pressure decreased during the music intervention compared with baseline. Diastolic blood pressure decreased during the music intervention from baseline during time 2, but not time 1. Subjects with high baseline scores of noise sensitivity preoperatively had higher baseline levels of noise annoyance in the critical care unit the first postoperative day. Subjects rated the music intervention as highly enjoyable regardless of their baseline noise sensitivity or noise annoyance. CONCLUSION: Results of this study support the idea that noise annoyance is a highly individual phenomenon, influenced by a transaction of personal and environmental factors. Use of a music intervention with cardiac surgery patients during the first postoperative day decreased noise annoyance, heart rate, and systolic blood pressure, regardless of the subject's noise sensitivity.

Analysis of Variance↗

Female voice communications in high levels of aircraft cockpit noises--Part I: spectra, levels, and microphones.

HYPOTHESIS: Female produced speech, although more intelligible than male speech in some noise spectra, may be more vulnerable to degradation by high levels of some military aircraft cockpit noises. The acoustic features of female speech are higher in frequency, lower in power, and appear more susceptible than male speech to masking by some of these military noises. Current military aircraft voice communication systems were optimized for the male voice and may not adequately accommodate the female voice in these high level noises. METHODS: This applied study investigated the intelligibility of female and male speech produced in the noise spectra of four military aircraft cockpits at levels ranging from 95 dB to 115 dB. The experimental subjects used standard flight helmets and headsets, noise-canceling microphones, and military aircraft voice communications systems during the measurements. RESULTS: The intelligibility of female speech was lower than that of male speech for all experimental conditions; however, differences were small and insignificant except at the highest levels of the cockpit noises. Intelligibility for both genders varied with aircraft noise spectrum and level. Speech intelligibility of both genders was acceptable during normal cruise noises of all four aircraft, but improvements are required in the higher levels of noise created during aircraft maximum operating conditions. CONCLUSIONS: The intelligibility of female speech was unacceptable at the highest measured noise level of 115 dB and may constitute a problem for other military aviators. The intelligibility degradation due to the noise can be neutralized by use of an available, improved noise-canceling microphone, by the application of current active noise reduction technology to the personal communication equipment, and by the development of a voice communications system to accommodate the speech produced by both female and male aviators.

Adult↗

[The level of the musical loud sound and noise induced hearing impairment].

Recently, there has been an increasing number of reports concerning hearing impairment which musical loud sound is thought to be one of the causes. We are getting more of this musical loud sound as cassette tape recorders with head phones such as Walkman and so forth get popular as well as occasions to attending rock concerts and going to discotheques increase. This hearing impairment is generally called discotheque deafness and the following three types are considered; 1) deafness which have fixed by accumulation of loud sound over a long period of time as seen in people involved in musical performance such as rock musicians and mixing engineers; 2) abrupt noise induced hearing impairment triggered by loud sound and 3) state of deafness which is a progressing stage towards recovery of noise induced temporary threshold shift (NITTS), which occurs temporarily by a loud sound stimulus, and hearing ability recovers afterward. However, it is considered that these musical loud sounds not only changes every moment according to method of performing or type of music, but the volume of the sound actually reaching the auditory sense differs largely by locations and direction of the ear and speakers. So it becomes necessary to measure the accumulation of the noise which each individual is exposed under over a long period of time and at the same time carry out the regular medical checkups including hearing test to check the initiation and advancement of the noise induced hearing impairment. Then we can examine the relationship between loudness of the environmental noise and initiation and advancement of the hearing impairment. However, there has not been a device which is compact and measures noise exposure individually over a long period of time. So we have experimentally produced ultra compact noise dosimeter which we named Noise Badge, and with it we actually measured individual noise exposure over a long time in rock music, noise in discotheque and noisy factory. Then we examined the relationship between these loud sound and noise induced temporary threshold shift (NITTS) in discotheques and noise proof room using simulation of loud sound exposure. Moreover, we measured the most comfortable loudness level of head phones in each examine and different types of music with environmental noise in consideration, thus examining the relationship between musical loud sound and the hearing impairment.

Adaptation, Physiological↗

Spatial integration and effective spectral density of one-dimensional noise masks.

When masking one-dimensional gratings, the strongest masking effect is achieved by using one-dimensional spatial noise, which can be regarded as a special case of two-dimensional noise where the noise check height is equal to the grating height. The extent of spatial integration in the human visual system is limited, however. Hence, our aim was to investigate whether the effective height of noise checks of one-dimensional noise is similarly limited. We measured detection thresholds for vertical sinusoidal gratings with added spatial noise. The width of the noise checks remained constant, but their height increased until equal to the height of the image window which made noise one-dimensional. The contrast energy thresholds increased in direct proportion to increasing noise check height and the spectral density of noise, calculated by taking into account both the height and the width of the noise checks. The increase levelled off, however, after the critical noise check height (nyc). The critical noise check height in grating cycles changed as a function of spatial frequency (f) as nyc = 4.7 [1 + (1.4/f)2]-0.5. According to our results the effective height of noise checks was thus limited in accordance with studies on spatial integration, showing scale invariance above 1.4 c/deg.

Adult↗

The influence of laser field noise on controlled quantum dynamics.

The influence of laser noise on the dynamics of simple quantum systems is analyzed. An anharmonic ladder is chosen for illustration and several pulses are obtained that optimize the yield of a quantum transition by constraining the laser parameters. The following models of laser noise are introduced: Amplitude white noise, phase white noise, frequency white noise and shot-to-shot static noise in the different pulse parameters. It is shown that the optimal pulses are robust to white amplitude noise, since the system acts as a dynamical filter. White phase noise affects the optimal pulses in a similar way by reducing the pulse area. This effect can be easily compensated for by pulse amplitude rescaling, up to a high level of noise. White frequency noise reduces the pulse area and induces spectral broadening, more strongly affecting the high frequency components. It can be partially compensated for by amplitude rescaling. The effects of static noise in the parameters cannot be easily corrected. It is shown that optimal pulses that drive n-photon transitions become more sensitive to noise in the amplitude and less sensitive to noise in the frequency as n increases. The effects of noise in the relative phase rapidly become constant for a large number of interfering pathways.

Journal Article↗

Robust stochastic resonance: signal detection and adaptation in impulsive noise.

Stochastic resonance (SR) occurs when noise improves a system performance measure such as a spectral signal-to-noise ratio or a cross-correlation measure. All SR studies have assumed that the forcing noise has finite variance. Most have further assumed that the noise is Gaussian. We show that SR still occurs for the more general case of impulsive or infinite-variance noise. The SR effect fades as the noise grows more impulsive. We study this fading effect on the family of symmetric alpha-stable bell curves that includes the Gaussian bell curve as a special case. These bell curves have thicker tails as the parameter alpha falls from 2 (the Gaussian case) to 1 (the Cauchy case) to even lower values. Thicker tails create more frequent and more violent noise impulses. The main feedback and feedforward models in the SR literature show this fading SR effect for periodic forcing signals when we plot either the signal-to-noise ratio or a signal correlation measure against the dispersion of the alpha-stable noise. Linear regression shows that an exponential law gamma(opt)(alpha)=cA(alpha) describes this relation between the impulsive index alpha and the SR-optimal noise dispersion gamma(opt). The results show that SR is robust against noise "outliers." So SR may be more widespread in nature than previously believed. Such robustness also favors the use of SR in engineering systems. We further show that an adaptive system can learn the optimal noise dispersion for two standard SR models (the quartic bistable model and the FitzHugh-Nagumo neuron model) for the signal-to-noise ratio performance measure. This also favors practical applications of SR and suggests that evolution may have tuned the noise-sensitive parameters of biological systems.

Journal Article↗

Autonomic effects on noise recorded during signal-averaged electrocardiography.

The purpose of this study was to assess the effects of autonomic stimulation and blockade on noise levels and to compare the noise measurements in the ST and TP segments of the signal-averaged ECG. Five-minute electrocardiographic data were recorded in 14 normal volunteers (8 males and 6 females; mean age 28.5 +/- 5.0 years) on two separate days (day 1-baseline, epinephrine infusion, isoproterenol infusion, beta-blockade, and combined adrenergic and parasympathetic blockade; day 2-baseline, phenylephrine infusion, parasympathetic blockade, and during phenylephrine infusion following atropine). Signal averaging was done off-line on 100 beats and noise was measured in both the ST and TP segments as the standard deviation of voltage in the segment of interest. For all conditions tested, the mean noise level measured in the ST segment (0.46 +/- 0.16 microV) was significantly less than that measured in the TP segment (0.52 +/- 0.24 microV; P = 0.0003), but there was good correlation between the noise measured in the ST and the TP segment (R2 = 0.62, P < 0.0001). Noise increased with isoproterenol infusion and decreased following adrenergic blockade. In addition, day 2 baseline noise was less than baseline noise on day 1. Finally, neither parasympathetic stimulation or blockade nor alpha-adrenergic stimulation significantly affected signal-averaged electrocardiography (SAECG) noise levels. Thus, the data support the notion that enhanced sympathetic tone increases noise levels and beta-adrenergic blockade may decrease noise levels, likely due to effects from muscle sympathetic nerve activity. These findings are important since the target population for the SAECG are patients with myocardial infarction and congestive heart failure, conditions associated with increased sympathetic tone, which may in turn impact on the reproducibility or technical aspects of the SAECG. In addition, because noise in the ST and TP segments are highly correlated and the noise measured in the ST segment is less than that in the TP segment, uniform adoption of noise measurement in the ST segment seems most appropriate.

Adrenergic Antagonists↗

Analysis of electrical noise in turtle cones.

1. Properties of the light-sensitive voltage noise in cones in the retina of the turtle, Pseudemys scripta elegans, have been studied by intracellular recording.2. Suppression of the noise by light was a function of the hyperpolarizing response of a cone but not of the size or pattern of illumination.3. Power density spectra of the noise were fitted in many cones by the product of two Lorentzians with characteristic time constants tau(1) and tau(2) averaging 40 and 7 msec respectively. The spectra of some cells were peaked and could be fitted by a resonance curve.4. Spectra in dim light exhibited decreased low frequency power. They could often be fitted by a product of two Lorentzians using the same value of tau(2) as used in darkness but decreasing tau(1) and the zero frequency asymptote. An e-fold reduction in tau(1) occurred with lights which hyperpolarized by 4-7 mV.5. Injection of hyperpolarizing currents of about 0.1-0.2 nA into weakly coupled cones reduced the noise, and also reduced the sensitivity to dim flashes.6. The variance-voltage relation during steady illumination of different intensities differed from cone to cone. Dim lights increased the noise in some cells and decreased it in others, but moderately bright lights which gave steady responses of more than about one third maximal reduced the noise in all cells.7. When the cell was transiently depolarized during the differentiated component following steady illumination, the noise was less than it was after prolonged darkness.8. In the after-effect of bright light, the time course of recovery of noise was the same as that of flash sensitivity and voltage. The noise was reduced e-fold for hyperpolarizations averaging 3 mV while for sensitivity this reduction occurred for 1.3 mV. For a given hyperpolarization the noise was lower during the after-effect than during steady dim illumination.9. When a series of dim flashes was delivered to a cone, no significant increase in variance over the dark noise was detected during the photo-response. This implies that each photoisomerization evokes no more than about 1.5 muV at the peak of the response in a coupled cone, corresponding to about 50 muV in an isolated cone.10. The elementary shot events underlying the noise are about 100 muV in amplitude in an isolated cone, have a characteristic time constant of 16-60 msec and reflect unit conductance fluctuations of about 16 pS (S, Siemen identical with Omega(-1)).11. It is concluded that the noise source is internal to the cones. We postulate that the noise arises from opening and closing of the light-sensitive ionic channels in the outer segment, and that in darkness there is a residual concentration of the blocking substance which on average closes up to about one third of the channels. It seems likely that the unit event involves a considerable number of blocking molecules and ionic channels.

Action Potentials↗

Experimental evaluation of leaky least-mean-square algorithms for active noise reduction in communication headsets.

An adaptive leaky normalized least-mean-square (NLMS) algorithm has been developed to optimize stability and performance of active noise cancellation systems. The research addresses LMS filter performance issues related to insufficient excitation, nonstationary noise fields, and time-varying signal-to-noise ratio. The adaptive leaky NLMS algorithm is based on a Lyapunov tuning approach in which three candidate algorithms, each of which is a function of the instantaneous measured reference input, measurement noise variance, and filter length, are shown to provide varying degrees of tradeoff between stability and noise reduction performance. Each algorithm is evaluated experimentally for reduction of low frequency noise in communication headsets, and stability and noise reduction performance are compared with that of traditional NLMS and fixed-leakage NLMS algorithms. Acoustic measurements are made in a specially designed acoustic test cell which is based on the original work of Ryan et al. ["Enclosure for low frequency assessment of active noise reducing circumaural headsets and hearing protection," Can. Acoust. 21, 19-20 (1993)] and which provides a highly controlled and uniform acoustic environment. The stability and performance of the active noise reduction system, including a prototype communication headset, are investigated for a variety of noise sources ranging from stationary tonal noise to highly nonstationary measured F-16 aircraft noise over a 20 dB dynamic range. Results demonstrate significant improvements in stability of Lyapunov-tuned LMS algorithms over traditional leaky or nonleaky normalized algorithms, while providing noise reduction performance equivalent to that of the NLMS algorithm for idealized noise fields.

Journal Article↗

Stimulus dependencies of the gerbil brain-stem auditory-evoked response (BAER). III: Additivity of click level and rate with noise level.

Two experiments were performed that evaluated the effects of ipsilateral-direct broadband noise maskers on the gerbil brain-stem auditory-evoked response (BAER) to click stimuli. In experiment 1, clicks were presented at 27 Hz at levels including 70, 80, 90, and 100 dB pSPL. Noise conditions included a no-noise control, and included noise levels varying in 10-dB increments from 20 dB SPL to a maximum noise level of 50, 60, 70, and 80 dB SPL for click levels of 70, 80, 90, and 100 dB pSPL, respectively. Gerbil BAER peaks were labeled with small roman numerals to distinguish them from human BAER peaks. The dependent variables included waves i and v latencies and amplitudes. Peak latencies increased and peak amplitudes decreased with decreasing click level and increasing noise level. To a first approximation, peak latencies and amplitudes showed changes with increasing noise level that were similar across click level. With increasing click level, there was little or no effect on the i-v interval. There was an increase in the i-v interval with increasing noise level. In experiment 2, click level was held constant at 90 dB pSPL, and click rates included 15, 40, 65, and 90 Hz. For each click rate, noise conditions included a no-noise control, and noise levels included 20, 30, 40, 50, 60, and 70 dB SPL. With increasing click rate and noise level, there was an increase in peak latencies, an increase in the i-v interval, and a decrease in peak amplitudes. The magnitude of peak latency and amplitude shifts with increasing click rate was dependent on noise level. Specifically, the magnitude of rate-dependent changes decreased with increasing level of broadband noise. These data are compared to human BAER experiments, and are found to be in fundamental agreement.

Animals↗

Effects of interaural time delays of noise stimuli on low-frequency cells in the cat's inferior colliculus. III. Evidence for cross-correlation.

1. We tested the coincidence, or cross-correlation, model of Jeffress, which proposes a neuronal mechanism for sensitivity to interaural time differences (ITDs) in low-frequency cells in the central nucleus of the inferior colliculus (ICC) of the cat. Different tokens of Gaussian noise stimuli were delivered to the two ears. We studied the neural responses to changes in ITDs of these stimuli and examined the manner in which the binaural cells responded to them. All of our results support the idea that the central binaural neurons perform an operation very similar to cross-correlation on the inputs arriving from each side. These inputs are transformed from the actual acoustic signal by the peripheral auditory system, and these transformations are reflected in the properties of the cross-correlations. 2. The responses to ITDs of identical broadband noise stimuli to the two ears varies cyclically as a function of ITD at a frequency close to the best frequency of the neuron. This cyclic response is a consequence of the narrowband filtering of the wideband acoustic signal by the auditory nerve fibers. To examine the effects of using stimuli to the two ears that were correlated to each other to different degrees, we generated pairs of noises. Each pair consisted of one standard noise, which was delivered to one ear, and a linear sum of two standard uncorrelated noises, which was delivered to the other ear. The responses of 34 neurons in the ICC to ITDs of noises with variable interaural coherence were examined. When partially correlated noises were delivered, there was a positive and approximately linear relationship between the degree of modulation of the response as a function of ITD and interaural coherence. The degree of modulation was measured by the synchronization coefficient, or vector strength, over one period of the ITD curve. 3. We examined the effects of altering the interaural phase relationships of the input noise stimuli. The phase of the noise stimuli was changed by digitally filtering the standard noise so that only a phase delay was imposed. The responses to ITDs with differing interaural phase relationships were then studied by delivering a phase-shifted noise to one ear and the standard noise to the other. The ITD curves in response to phase-shifted noise were shifted by about the same amount as the shift of the stimulus; the shift of the response was measured with respect to the case with identical noises to the two ears.(ABSTRACT TRUNCATED AT 400 WORDS)

Acoustic Stimulation↗

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

BACKGROUND: Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. METHODS: Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. RESULTS: The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. CONCLUSION: The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred.

Journal Article↗