Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Microwave enhanced Akabori reaction for peptide analysis.

The Akabori reaction, devised in 1952 for the identification of C-terminus amino acids, involves the heating of a linear peptide in the presence of anhydrous hydrazine in a sealed tube for several hours. We report here a modified Akabori reaction that rapidly identifies the C-terminus amino acid in a polypeptide including its amino acid sequence information at both the C-terminus and the N-terminus. This modified methodology demonstrates the fundamentals of microwave chemistry applied to bioanalytical problems. In this modified process, hydrazinolysis has been accelerated by the application of microwave irradiation. In our reaction, the linear peptide and hydrazine solution, contained in a loosely covered conical flask, was exposed to a few minutes of irradiation using an unmodified domestic microwave oven. While the classical Akabori reaction required several hours, the microwave assisted reaction takes just minutes. If dimethyl sulfoxide is added to dilute the reaction mixture, the process is retarded enough to allow aliquots of the reaction mixture to be drawn every few minutes over a period of about an hour in order to study the progress of hydrazinolysis. Reaction products were monitored by mass spectrometry-primarily FAB-MS. In addition to providing sequence information, the microwave enhanced Akabori reaction quickly detects the presence of arginine (Arg) by converting each Arg to ornithine (Orn). Furthermore, certain amino acids, containing beta-SH, CO2H, and CONH2 groups in their side chain, are susceptible to modification by hydrazine, thereby, providing rapid confirmation of the presence of these amino acid residues. In these preliminary studies, the following oligopeptides were analyzed to demonstrate the effectiveness of our approach; the dipeptide (Trp-Phe), the tripeptide (Tyr-Gly-Gly), the tetrapeptide (Pro-Phe-Gly-Lys), the heptapeptide (Ala-Pro-Arg-Leu-Arg-Phe-Tyr), and a N-terminal blocked tripeptide (N-acetyl-Met-Leu-Phe).

Amino Acids↗

Microwave-assisted steam distillation for simple determination of polychlorinated biphenyls and organochlorine pesticides in sediments.

A novel sample extraction technique for polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) analysis using microwave-heating device is developed. In this study, microwave-assisted extraction (MAE) and steam distillation techniques were combined. Desorption of the anatytes from solid matrixes was accelerated with water vapor which was generated by microwave irradiation. A sample holder in a commercial microwave extraction cell kept the sample from direct contact with the organic solvent for analytes trapping during the treatment process. Therefore, relatively clean extracts were obtained with small amount of solvents. Without any cleanup steps, the obtained extract could be analyzed with gas chromatograph/mass spectrometers (GC/MS). Six PCB congeners (PCB15, 28, 70, 101, 180, 194, 209) and three OCPs (gamma-HCH, 4,4'-DDE, 4,4'-DDD) in two marine sediment samples (a sediment collected from a bay of Kyusyu Island, Japan, and a certified reference material NIST SRM1944) were analyzed by using this microwave-assisted steam distillation (MASD) technique and another extraction method (exhaustive steam distillation, MAE, and Soxhlet extraction); and comparisons of the results are shown in this report. Although recovery yields of highly chlorinated biphenyls (PCB180, 194, 209) and relatively polar OCPs (gamma-HCH, 4,4'-DDD) were low (30-60%) compared with other analytes (PCB15, 28, 70, 101, 4,4'-DDE; recovery, 80-100%), use of isotope labeled internal standards for the MASD technique gave comparable results with the values obtained by other extraction methods and the certified values in the samples.

Gas Chromatography-Mass Spectrometry↗

Application of microwave energy in the manufacture of enhanced-quality green tea.

Green tea manufacture was standardized with respect to the inactivation of polyphenol oxidase (PPO), rolling, and drying for quality manufacture. Inactivation of PPO by parching, steaming, microwave heating, and oven heating was monitored in tea shoots. The inactivated shoots were rolled under regimens of high and low pressures and dried by microwave heating, oven heating, or sun-drying; total phenols and catechins were estimated. Parched and sun-dried teas contained the lowest levels of total phenols and catechins, and their infusions were dull in color with a slightly burnt odor. Microwave-inactivated and-dried teas showed the highest levels of total phenols and catechins, and their infusions were bright in color and sweet in taste with a subtle pleasant odor. In steam-inactivated and oven/microwave-dried teas, total phenol and catechin contents were intermediate between parched and sun-dried teas and microwave-inactivated and microwave-dried teas, and their infusions were bright with a umami taste.

Catechin↗

Different effects of microwave and ultrasound on the stability of (all-E)-astaxanthin.

Both microwave-assisted extraction (MAE) and ultrasound-assisted extraction (UAE) have been widely applied in the extraction of a variety of biologically active compounds including carotenoids due to their lower pollution to environment, high extraction efficiency, lower cost, and shorter extraction time as compared to conventional extraction techniques. However, there are few reports on their effects on the stability of these compounds. In the present study, the stability of (all-E)-astaxanthin, one of the carotenoids, was examined under the action of both ultrasound and microwave. Results showed that microwave induced the isomerization of (all-E)-astaxanthin to its Z analogues, preferentially to (13Z)-astaxanthin as analyzed by HPLC coupled with diode array detection and LC-MS; and the percentage of the isomerization increased with increasing both treatment time and microwave power. In contrast to the microwave, the ultrasound degraded (all-E)-astaxanthin to unidentified colorless compound(s) as suggested by HPLC analysis and UV/vis measurements, and the degradation likewise increased as both treatment time and ultrasonic power increased. The results presented here emphasized that both MAE and UAE techniques should be carefully used in the extraction of unstable compounds such as (all-E)-astaxanthin.

Chromatography, High Pressure Liquid↗

Enzyme inactivation analysis for industrial blanching applications: comparison of microwave, conventional, and combination heat treatments on mushroom polyphenoloxidase activity.

Browning reactions in fruits and vegetables are a serious problem for the food industry. In mushrooms, the principal enzyme responsible for the browning reaction is polyphenoloxidase (PPO). Microwaves have recently been introduced as an alternative for the industrial blanching of mushrooms. However, the direct application of microwave energy to entire mushrooms is limited by the important temperature gradients generated within the samples during heating, which can produce internal water vaporization and associated damage to the mushrooms texture. A microwave applicator has been developed, whereby irradiation conditions can be regulated and the heating process monitored. Whole edible mushrooms (Agaricus bisporus) were blanched by conventional, microwave, and combined heating methods to optimize the rate of PPO inactivation. A combined microwave and hot-water bath treatment has achieved complete PPO inactivation in a short time. Both the loss of antioxidant content and the increase of browning were minor in the samples treated with this combined method when compared to the control. This reduction in processing time also decreased mushroom weight loss and shrinkage.

Agaricales↗

Flavor volatiles and physical properties of vacuum-microwave- and air-dried sweet basil (Ocimum basilicum L.).

Basil (Ocimum basilicum L.) was dried using conventional hot air or the recently developed vacuum-microwave dryers. The effect of the drying method on the relative abundance of major flavor volatiles, rehydration rate, color, and structural integrity of the plant was evaluated. Dynamic headspace analysis of volatiles present in fresh or dried basil revealed that linalool and methylchavicol (estragole) were the two major headspace volatile compounds of the plant sample. Vacuum-microwave dehydrated basil yielded approximately 2.5 times the linalool and 1.5 times the methylchavicol of the air-dried samples. Furthermore, the vacuum-microwave-treated samples yielded more volatiles than fresh basil, due to chemical reactions during drying. Air-dried samples of basil had darker and fewer green hues than those prepared by vacuum microwave. Vacuum-microwave-dried samples had a higher rehydration rate, whereas the potential of the plant material to rehydrate was hindered in air-dried samples. This is likely attributed to the dramatic and pronounced structural collapse of the air-dried cells as revealed by the scanning electron microscope.

Food Handling↗

Rapid detection of meso-diaminopimelic acid in lactic acid bacteria by microwave cell wall hydrolysis.

Two innovative microwave hydrolysis procedures for rapidly detecting meso-diaminopimelic acid in lactic acid bacteria have been developed. Whole-cell hydrolysis was performed both in liquid phase and vapor phase with 6 N HCl in sealed vessels using a microwave oven equipped with pressure and temperature probes. The presence or absence of meso-diaminopimelic acid determined by TLC, after the application of liquid- and vapor-phase microwave hydrolysis procedures, gave the same qualitative results as those obtained by traditional hydrolysis. These standardized microwave hydrolysis procedures permit a drastic reduction in hydrolysis time, from 16-20 h to less than 10 min and, consequently, in the total time of meso-diaminopimelic acid analysis (less than 90 min). Microwave hydrolysis in vapor phase is particularly convenient because, besides reducing hydrolysis time, it also eliminates the successive troublesome step of HCl removal.

Cell Wall↗

Structural and conformational properties of 2-propenylgermane (allylgermane) studied by microwave and infrared spectroscopy and quantum chemical calculations.

The structural and conformational properties of allylgermane have been investigated using Stark and Fourier transform microwave spectroscopies, infrared spectroscopy, and high-level quantum chemical calculations. The parent species H2C=CHCH2GeH3 was investigated by microwave spectroscopy and infrared spectroscopy, while three deuterated species, namely, H2C=CDCH2GeH3, H2C=CHCHDGeH3, and H2C=CHCH2GeD3, were studied only by infrared spectroscopy. The microwave spectra of the ground vibrational state as well as of the first excited state of the torsion vibration around the sp2-sp3 carbon-carbon bond were assigned for the 70Ge, 72Ge, and 74Ge isotopomers of one conformer. This rotamer has an anticlinal arrangement for the C=C-C-Ge chain of atoms. The infrared spectrum of the gas in the 500-4000 cm(-1) range has been assigned. No evidence of additional rotameric forms other than anticlinal was seen in the microwave and infrared spectra. Several different high-level ab initio and density functional theory calculations have been performed. These calculations indicate that a less stable form, having a synperiplanar conformation of the C=C-C-Ge link of atoms, may coexist with the anticlinal form. The energy differences between the synperiplanar and anticlinal forms were calculated to be 5.6-9.2 kJ/mol depending on the computational procedure. The best approximation of the equilibrium structure of the anticlinal rotamer was found in the MP2/aug-cc-pVTZ calculations. The barrier to internal rotation of the germyl group was found to be 6.561(17) kJ/mol, from measurements of the splitting of microwave transitions caused by tunneling of the germyl group through its threefold barrier.

Chemistry, Physical↗

Effects of microwave irradiation on rat hepatic tissue evaluated by enzyme histochemistry for acid phosphatase.

Microwave coagulation therapy (MCT) has been applied to small hepatic carcinomas. To clarify the sequential changes in histology and the viability of the microwave-irradiated tissue, we examined irradiated normal rat liver with enzyme histochemistry for acid phosphatase (AcP). In the samples immediately after irradiation, the margin of the irradiated region was indistinct in H&E stain, while AcP enzyme histochemistry disclosed well-demarcated distinct zones: an inner zone adjacent to the electrode without AcP activity and a surrounding outer zone with attenuated enzyme activity. In the inner zone, the nuclear staining with hematoxylin persisted for at least one month, whereas that in the outer zone disappeared 24 hr after irradiation and was accompanied by neutrophilic infiltration and then replaced by granulation tissue. Our results indicated that microwave irradiation caused tissue fixation in the inner zone and coagulative necrosis in the outer zone. Because microwave-fixed cells retained their morphology well, they appeared very similar to normal cells in H&E-stained section. Enzyme histochemistry may be useful for assessment of cellular viability after microwave irradiation, by enabling us to distinguish fixed cells from viable cells.

Acid Phosphatase↗

Microwave enhanced electroanalysis of formulations: processes in micellar media at glassy carbon and at platinum electrodes.

The direct electroanalysis of complex formulations containing alpha-tocopherol (vitamin E) is possible in micellar solution and employing microwave-enhanced voltammetry. In the presence of microwave radiation substantial heating and current enhancement effects have been observed at 330 microm diameter glassy carbon electrodes placed into a micellar aqueous solution and both hydrophilic and highly hydrophobic redox systems are detected. For the water soluble Fe(CN)(6)(3-/4-) redox system in micellar aqueous solutions of 0.1 M NaCl and 0.1 M sodium dodecylsulfate (SDS) at low to intermediate microwave power, thermal effects and convection effects are observed. At higher microwave power, thermal cavitation is induced and dominates the mass transport at the electrode surface. For the micelle-soluble redox systems tert-butylferrocene and 2,5-di-tert-butyl-1,4-benzoquinone, strong and concentration dependent current responses are observed only in the presence of microwave radiation. For the oxidation of micelle-soluble alpha-tocopherol current responses at glassy carbon electrodes are affected by adsorption and desorption processes whereas at platinum electrodes, analytical limiting currents are obtained over a wide range of alpha-tocopherol concentrations. However, for the determination of alpha-tocopherol in a commercial formulation interference from proteins is observed at platinum electrodes and direct measurements are possible only over a limited concentration range and at glassy carbon electrodes.

Carbon↗

Experimental study of large-volume microwave ablation in the liver.

BACKGROUND: Microwave coagulation therapy is useful in the destruction of small, irresectable liver tumours of primary and secondary origin. Unfortunately, the small lesion size produced by currently available equipment makes it difficult and time consuming completely to ablate lesions larger than 3 cm in diameter. A microwave system capable of producing large-volume ablations in very short periods of time has been developed. Using a large-animal model the ability of the equipment to produce large-volume lesions in a safe, predictable and dose-dependent manner was tested. METHODS: Fourteen large white pigs were anaesthetized and underwent multiple microwave treatments. The animals were killed at different timepoints to investigate lesion size and evolution. RESULTS: The microwave system was able to generate large-volume ablations of up to 6.5 cm in diameter in a controlled and dose-dependent manner. CONCLUSION: This novel microwave system allows the ablation of large volumes of liver tissue in a short period of time. The ability to produce lesions reproducibly and safely highlights the potential of this system in the future treatment of irresectable liver tumours.

Analysis of Variance↗

Rapid staining of ultrathin sections with the use of a microwave oven.

The microwave oven has many potential applications, ranging from tissue fixation to staining for light and electron microscopy. This study was planned to speed up the staining of ultrathin sections. The first set of grids was stained conventionally with uranyl acetate and Reynold's lead citrate solutions. The other grids were stained with the same solutions by microwave irradiation. The electron micrographs of grids stained using the microwave technique were as satisfactory as the grids stained conventionally. Microwave-treated grids demonstrated more uniform staining and less precipitate. The use of a microwave oven shortened staining time by approximately 38 min.

Animals↗

Microwave, irrigated, pulsed, or conventional radiofrequency energy source: which energy source for which catheter ablation?

The aim of the study was to compare the diameter of endomyocardial lesions induced with the delivery of microwave, cooled, or pulsed energy versus conventional RF energy. In vitro tests were performed in fresh endomyocardial preparations of pig hearts in a 10-L bath of NaCl 0.9% solution at 37 degrees C and constant 1.5 L/min flow. Ablation 7 Fr catheters with 4-mm tip electrodes were used, except for the delivery of microwave energy. Energy delivery time was set to 60 s/50 W in all experiments. Cooled energy delivery was performed with a closed irrigation catheter. Pulsed energy delivery was performed using a special controller with a duty-cycle of 5 ms. Microwave energy was delivered with a 2.5-GHz generator and 10-mm antenna. Electrode temperature and impedance were measured simultaneously. After ablation, lesion length, width, and depth were measured with microcalipers, and volume calculated by a formula for ellipsoid bodies. Each energy delivery mode was tested in ten experiments. The deepest lesions were created with cooled energy delivery, and the largest volume by microwave energy delivery. Pulsed RF produced significantly deeper lesions than conventional RF energy delivery. Cooled or pulsed RF energy delivery created deeper transmural lesions than conventional RF. To create linear lesions at anatomically complex sites (isthmus), microwave energy seemed superior by rapidly creating deep and long lesions.

Animals↗

Optimizing transurethral microwave thermotherapy: a model for studying power, blood flow, temperature variations and tissue destruction.

OBJECTIVE: To examine the role of microwave power and blood flow on temperature variations and tissue destruction in the prostate, using a theoretical model of transurethral microwave thermotherapy (TUMT), and thus compare fixed-energy TUMT with no intraprostatic temperature monitoring (constant microwave power applied over a fixed period) with 'feedback' TUMT in which the microwave power is adjusted according to the monitored intraprostatic temperature. MATERIALS AND METHODS: The temperature distribution in the prostate was modelled for a typical TUMT catheter at various blood flow rates. The volume of tissue destroyed was simultaneously calculated from cell survival data after thermal exposure. The calculated quantity of tissue destroyed at the different microwave power levels and blood flow rates was used to describe qualitatively the simulated treatments. RESULTS: Treatment monitoring and consistency were better during feedback TUMT than fixed-energy TUMT, in that the former compensated for variations in blood flow rate. The modelled values agreed with observations during real TUMT. CONCLUSIONS: Blood flow rate is a key factor in the outcome of TUMT. Only by measuring intraprostatic temperature is it possible to compensate for the large variations in prostatic blood flow and obtain consistent treatment results. Repeated interruptions prompted by high rectal temperatures should be minimized and preferably avoided, as the quantity of tissue destroyed is then greatly reduced, and in extreme cases the treatment is totally ineffective.

Blood Flow Velocity↗

Rapid controlled thawing of fresh-frozen plasma in a modified microwave oven.

A microwave oven has been specifically modified to permit rapid thawing of fresh-frozen plasma (FFP) by using a rotating disc with a temperature sensor to hold the plasma bag. This modification makes it possible to mix the FFP continuously during thawing, and automatically shuts the oven off when the plasma reaches 21 degrees C. Comparisons were made between FFP thawed in the modified microwave oven and FFP thawed conventionally in a 37 degrees C waterbath. The following tests were done: total protein, albumin, and immunoglobulin concentrations; plasma fibrinogen, factor VIII, and factor IX activities; protein electrophoresis, albumin aggregation, hemolytic complement activity, and plasma particle count and size. In no case was there a significant difference between plasma thawed in the microwave oven compared with that thawed in the waterbath. Further, microwave thawing was reliable and rapid; all units of FFP thawed in less than 6 minutes, and the thawed plasma did not vary by more than 6 degrees C from the preselected final temperature of 21 degrees C. Thus, it appears that controlled thawing of FFP in a microwave oven specifically designed for this purpose is an effective and reliable method and has many advantages over conventional thawing of FFP.

Adenine↗

Microwave coagulation therapy for hepatocellular carcinoma.

BACKGROUND & AIMS: Surgical resection is not always feasible in patients with hepatocellular carcinoma. Microwave coagulation therapy has been used as an alternative to resection, and its efficacy has been evaluated. METHODS: Nineteen patients with unresectable hepatocellular carcinoma underwent microwave coagulation therapy through laparotomy (n = 12), laparoscopy (n = 5), or thoracotomy (n = 2) because of advanced liver cirrhosis and/or intrahepatic metastases. One nodule was treated in 13 patients, tumor size ranged from 5 to 90 mm. Patient outcomes were studied. RESULTS: Microwave coagulation therapy created a reproducible regional necrosis. Fourteen patients underwent potentially curative treatment; the remaining 5 patients underwent palliative treatment (n = 4) or incomplete tumor coagulation (n = 1). Of the 31 nodules treated, 28 underwent complete tumor ablation. Only 2 patients undergoing laparoscopic microwave coagulation therapy developed local recurrence. The coagulated area subsequently shrank. Patients showed rapid recovery without hepatic dysfunction. Thirteen patients, including 2 long-term survivors, are alive either without tumor (n = 10; 14-64 months) or with tumor (n = 3; 17-22 months). Six patients died of hepatocellular carcinoma (n = 4) or liver insufficiency (n = 2). CONCLUSIONS: This preliminary study suggests the efficacy of microwave coagulation therapy, including safety and potential curability, in patients with hepatocellular carcinoma with advanced liver cirrhosis and multifocal or central tumors.

Adult↗

[Microwave stimulated cell marker analysis. Possibilities for more rapid immune diagnosis].

We describe a successful rapid APAAP-complex technique using innovative application of microwave irradiation (MIWI) on Ficoll separated peripheral blood mononuclear cell smears of healthy donors. The typing with several monoclonal antibodies (MoAbs) against different cell surface antigens is compared with the conventional APAAP procedure. The commercial domestic microwave oven was operated at 2.45 GHz. Fifteen second irradiation at 350 W during all incubation steps, e.g. primary antibody, bridging antibody and APAAP-complexes produced excellent color reactions with Fast Red TR, Fast Blue BB, New Fuchsin or NBT similar with the conventional immunoenzyme procedure. The routinely usage of a Silicon-Chamber-System developed by us is applicable without limitation under microwave conditions. The results till now have shown that the application of microwave-technique (MIWI) eliminated the need for much longer incubation periods without lost of sensitivity. All immunological markers could be detected in the same degree as observed with the conventional method. We could demonstrate that an immunological diagnosis is possible within 30 minutes using air dried smears in an microwave oven.

Antigens, CD↗

Tensile strength of type IV dental stones dried in a microwave oven.

STATEMENT OF PROBLEM: It is known that drying dental stones in a microwave oven can save time, but the strength of the material may be affected by different drying methods. PURPOSE: This study evaluated the diametral tensile strength (DTS) of 5 type IV gypsum products at different time intervals using microwave and air-drying methods. MATERIAL AND METHOD: . A total of 300 cylinder specimens were prepared from 5 type IV dental stones (Moldano, Amberok, Herastone, Shera-Sockel, and Fujirock; n = 60 per stone) in accordance with the manufacturers' recommendations. Half of the specimens of each stone (n = 30) were dried in open air within a temperature range of 20 +/- 2 degrees C; the other half (n = 30) underwent initial setting in a silicone rubber mold in open air for 10 minutes and then were dried in a microwave oven for 10 minutes. Within these groups, 10 specimens were tested under diametral compression at each of the following time periods: 30, 60, and 120 minutes after drying. Three-way analysis of variance and Scheffe's post hoc test were performed for statistical comparisons at a significance level of P<.05. RESULTS: At all time intervals, the diametral tensile strength values for dental stones dried in a microwave oven (mean 2.99 MPa) were significantly higher (P<.01) than the values for specimens dried in open air (mean 2.53 MPa). CONCLUSION: Within the limitations of this study, microwave oven drying had a positive effect on the diametral tensile strength of 5 type IV dental stones.

Air↗