Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Frictional adhesion: A new angle on gecko attachment.

Directional arrays of branched microscopic setae constitute a dry adhesive on the toes of pad-bearing geckos, nature's supreme climbers. Geckos are easily and rapidly able to detach their toes as they climb. There are two known mechanisms of detachment: (1) on the microscale, the seta detaches when the shaft reaches a critical angle with the substrate, and (2) on the macroscale, geckos hyperextend their toes, apparently peeling like tape. This raises the question of how geckos prevent detachment while inverted on the ceiling, where body weight should cause toes to peel and setal angles to increase. Geckos use opposing feet and toes while inverted, possibly to maintain shear forces that prevent detachment of setae or peeling of toes. If detachment occurs by macroscale peeling of toes, the peel angle should monotonically decrease with applied force. In contrast, if adhesive force is limited by microscale detachment of setae at a critical angle, the toe detachment angle should be independent of applied force. We tested the hypothesis that adhesion is increased by shear force in isolated setal arrays and live gecko toes. We also tested the corollary hypotheses that (1) adhesion in toes and arrays is limited as on the microscale by a critical angle, or (2) on the macroscale by adhesive strength as predicted for adhesive tapes. We found that adhesion depended directly on shear force, and was independent of detachment angle. Therefore we reject the hypothesis that gecko toes peel like tape. The linear relation between adhesion and shear force is consistent with a critical angle of release in live gecko toes and isolated setal arrays, and also with our prior observations of single setae. We introduced a new model, frictional adhesion, for gecko pad attachment and compared it to existing models of adhesive contacts. In an analysis of clinging stability of a gecko on an inclined plane each adhesive model predicted a different force control strategy. The frictional adhesion model provides an explanation for the very low detachment forces observed in climbing geckos that does not depend on toe peeling.

Adhesiveness↗

Cushion form bearings for total knee joint replacement. Part 1: Design,friction and lubrication.

Cushion knee prostheses have been designed and constructed that produce approximately equal initial contact areas and theoretical film thicknesses compared with a conventional UHMWPE (ultra-high molecular weight polyethylene) joint. These compliant bearings had a flat tibial component which imposed fewer biomechanical constraints and allowed a greater range of movement. Friction experiments have been carried out on a pendulum simulator apparatus. The results showed that the cushion knee joints operated just within the mixed lubrication regime, but that they benefited from a substantial measure of fluid film lubrication. Microelastohydrodynamic lubrication was effective in preserving low friction and thin but effective lubricating films.

Biomechanical Phenomena↗

Pushability and frictional characteristics of medical instruments.

A tensile testing equipment is combined with a torque module and a 3D force tranducer to characterize the pushability of catheter systems inside modular vessel phantoms. The modular construction of the phantom allows using two dimensional vessel shapes with different contours. Inside the phantom we put a tube or a guide catheter in which the instruments are pushed or redrawn in the presence of a liquid (water, blood, etc.) at body temperature. During pushing or redrawing we measure axial and rotational values. Additionally, friction forces and coefficients are separately determined by using a special designed friction module. First results are presented and discussed.

Biomechanical Phenomena↗

Pipe friction head loss in transportation of high-concentration sludge for centralized solids treatment.

The objective of this study was to develop a method of predicting pipe friction head loss, which is a key factor in pipeline transportation of high-concentration sludge, thereby optimizing design for pipeline systems. The study involved both experimentation and analysis of pipeline transportation. Moreover, the study led to the representation of pipe friction head loss as functions of average velocity, transportation distance, pipe diameter, pipe interior roughness, and solids viscosity and temperature.

Algorithms↗

Low wear and friction in alumina/alumina total hip joints: a hip simulator study.

We studied the wear of state-of-the-art alumina/alumina total hip joints with the uniaxial five-station, and the three-axis single-station hip joint simulators of Helsinki University of Technology. The diameters of the joints were 26, 28 and 32 mm. Visual examination and weighing of the components showed no wear. Scanning electron microscopy showed that (a) the wear marks were slight, consisting of removal of grains, multidirectional grooving and mild abrasion, (b) the wear mechanisms were similar to those seen in components removed from patients, and (c) there was no marked difference in the specimens worn in the uniaxial vs. three-axis simulator. The coefficient of friction was measured throughout the 5 million cycle wear test with the three-axis simulator. The average value was 0.007. We conclude that alumina/alumina joints had low wear and friction under the present test conditions. The results are promising, since minimal wear is one of the prerequisites for long-term success in prosthetic joints.

Aluminum Oxide↗

Effects of isoproterenol and butylscopolamine on the friction between an artificial stone and the intraureteral wall in anesthetized rabbits.

PURPOSE: We evaluated the effects of the nonselective beta-adrenoceptor agonist isoproterenol and the nonselective muscarinic antagonist butylscopolamine on ureteral wall tension, namely friction between an artificial stone and the intraureteral wall, in anesthetized rabbits. MATERIALS AND METHODS: The relaxing effect of the drugs on the KCl induced tonic contraction was examined in isolated rabbit ureters. The effect of the drugs on the applied force needed for the artificial stone to pass at a constant speed through the ureter, called sliding force, was evaluated in anesthetized rabbits. RESULTS: In a concentration dependent manner isoproterenol but not butylscopolamine reduced the KCl induced contraction in isolated ureter (mean pD2 7.35 +/- 0.06). Intravenous administration of 1 and 10 microg./kg. isoproterenol significantly decreased the friction between the artificial stone and intraureteral wall in anesthetized rabbits with sliding force at 15 minutes after drug administration decreased by 54.5% and 63.6%, respectively. In contrast, 100 and 1,000 microg./kg. butylscopolamine intravenously had no evident effect on ureteral wall tension. CONCLUSIONS: Our results strongly suggest that ureteral smooth muscle relaxation by beta-adrenergic stimulation reduces ureteral wall tension, thereby, diminishing mechanical effects impeding the movement of a ureteral stone down the ureter.

Adrenergic beta-Agonists↗

Frictional resistance to sliding archwires with repeated displacement.

Fictional resistance between a length of stainless steel archwire and a single bracket was calculated, and the effects of cyclical displacement forces on frictional resistance were tested. With the application of repeated displacement forces to the archwire, the force required to slide the wire through the bracket was substantially reduced. The percentage reduction in the force required to slide the wire was dependent on the size of the displacement force applied to the archwire. Frictional resistance in the mouth may not be satisfactorily reflected by steady mode laboratory models. The clinical implications for different types of orthodontic brackets remain unresolved.

Dental Stress Analysis↗

Pediatric hand friction burn injuries secondary to treadmills.

A characteristic hand friction burn secondary to a treadmill fitness machine has been seen in fourteen pediatric patients. This retrospective review looks at mechanism of injury, digit(s) involved, depth of burn, initial treatment, time to referral and its effect on the final result, and the need and results of definitive treatment. Based on our findings, certain recommendations are made to avoid potential sequela due to this hand friction burn.

Accidents, Home↗

Friction-reducing devices for lateral patient transfers: a biomechanical evaluation.

The purpose of this study was to evaluate the efficacy of friction-reducing devices used for lateral patient transfers. A mannequin used to represent a dependent patient was transferred laterally from bed to stretcher. One male investigator repeated this task using 11 comparable lateral transfer aids or techniques. Applied force was measured using a dynamometer; postural analysis was prepared from still photography. Mean applied force, spinal forces, and population strength capabilities were calculated. The most efficacious mechanism for lateral patient transfers had extendable pull straps, low-friction material, and optimally located handles. Findings of this study will aid occupational health and safety clinicians and hospital-based caregivers in the selection of appropriate technologies to be used during lateral patient transfers. These devices improve patient safety and reduce the risk of back injury to caregivers.

Accidents, Occupational↗

Pyogenic granuloma on the hand subsequent to friction blister in a hand surgeon.

A case of pyogenic granuloma in a 62-year-old hand surgeon secondary to friction blister is reported. He developed a fast growing, hypertrophic inflammatory papule consisting of exceptionally richly vascularized granular tissue. This dusky red lesion was located on the thenar part of the hand. We find no prior report of PG attributed to friction blister.

Friction↗

Frictional contact dermatitis.

Frictional trauma to the palms and fingertips can provoke a dermatitis. Cases of frictional dermatitis have been recognized in workers handling large quantities of pressure-sensitive carbonless paper. Elimination of the trauma led to healing within 2-3 weeks.

Adult↗

Motion of polymorphonuclear leukocytes: theory of receptor redistribution and the frictional force on a moving cell.

As a cell moves over a surface, the distribution of membrane proteins that adhere to the surface will be changed relative to the distribution of these molecules on a static cell. Observations of this redistribution offer, in principle, evidence as to the mechanisms of membrane dynamics during cell locomotion. Toward extracting such information we present and analyze a mathematical model of receptor transport in the membrane by diffusion and convection, as affected by the making and breaking of the bonds between the receptors and the surface as the cell moves. We show that the disruption of receptor-surface bonds at the tail of the cell provides a mechanism by which the frictional force opposing a cell's motion is exerted, and calculate the magnitude of this force as a function of cell velocity. Assuming this to be the major contribution to the frictional force, we show that when the shear force on a cell is above a critical value it is no longer possible for the cell to slide across the surface. For such large forces, it is still possible for the cell to roll; alternatively the cell can be torn free of the surface. Our analysis of existing data on movement of polymorphonuclear leukocytes indicates that cell motion is not accompanied by a bulk flow of membrane from the front to the back of the cell. The data also indicate that cells do not tend to roll as they move over a surface under normal conditions. The data are most consistent with a model where the membrane as a whole is stationary but where receptors that bind to the surface become coupled to submembrane contractile proteins.

Animals↗

Temperature-dependent and friction-controlled electrochemically induced shuttling along molecular strings associated with electrodes.

The temperature and solvent composition dependence of the electrochemically stimulated rate of shuttling of the redox-active cyclophane, cyclobis(paraquat-p-phenylene), on a molecular string has been studied. The molecular string includes a pi-donor diiminebenzene-site that is associated on one side with an electrode, and stoppered on the other side with an adamantane unit. The cyclophane rests on the pi-donor site, owing to stabilizing pi-donor-acceptor interactions. Electrochemical reduction of the cyclophane units, to the bis-radical cation cyclophane, results in the shuttling of the reduced cyclophane towards the electrode, a process that is driven by the removal of the stabilizing donor-acceptor interactions, and the electrostatic attraction of the reduced product by the electrode. The latter process is energetically downhill, and is temperature-independent. Upon oxidation of the reduced cyclophane that is associated with the electrode, the energetically uphill shuttling of the oxidized cyclophane to the pi-donor site proceeds. The rate of this translocation process has been found to be temperature-dependent, and controlled by the solvent composition. The experimental results have been theoretically analyzed in terms of Kramers' molecular friction model. The theoretical fitting of the experimental results, using solutions of variable composition, reveals that the rate-constants for the uphill reaction in a pure aqueous solution follow the temperature-dependence of the viscosity of water. The results demonstrate the significance of friction phenomena in shuttling processes within molecular machines.

Journal Article↗

Role of a stochastic friction coefficient in open channel noise.

The electric current noise through an open channel in a membrane is analyzed with the aid of a stochastic differential equation to describe the process of ionic permeation along the channel. Unlike the Langevin theory, the effective friction constant of the channel is given by a deterministic quantity plus a multiplicative noise. The Brownian or additive noise is taken as white. Two models for the multiplicative noise are considered, a dichotomous Markov process and white noise. In both models, the correlation function decays exponentially and, therefore, the spectral density of the noise is a Lorentzian with a corner frequency proportional to the effective friction coefficient. The relaxation time of the fluctuations is modulated by the strength of the multiplicative noise. We conclude that these models characterize only those dynamical processes that occur on the rapid time scale of diffusion and cannot be used to describe slow conformational changes of a protein channel.

Animals↗

A method for assessing muscle fatigue during sprint exercise in humans using a friction-loaded cycle ergometer.

This study investigated the mechanical changes induced by muscle fatigue caused by repeated sprints and determined whether a friction-loaded cycle ergometer has any advantages for assessing muscle fatigue. Nine subjects performed 15 sprints, each of 5 s with a 25-s rest, on a friction-loaded cycle ergometer. The averaged force, power and velocity of each push-off were calculated. Maximal power decreased by 17.9%, with a concomitant slowing of muscle contraction, but without any change in the maximal force. These results demonstrated that repeated sprints slow down muscle contraction, leading to a fall in maximal power without any loss of force. This would suggest that fast twitch fibres are selectively fatigued by repeated sprints. However, the ergometer used in the present study made it difficult to evaluate the relative influences of contraction velocity and sprinting time. This was certainly the most important limitation. On the other hand, it showed the advantage of measuring instantaneous power and total work dissipated in the environment simultaneously. It also permitted a force-velocity relationship to be obtained from a single sprint and this relationship is known to be closely related to the muscle fibre composition.

Adult↗

Pericardial rub. Prospective, Multiple observer investigation of pericardial friction in 100 patients.

A prospective, multiple observer ausculatory and phonocardiographic study of 100 patients with pericardial friction confirmed the dominant prevalence of triphasic pericardial rubs (56 percent of patients with sinus rhythm). In 9 of 33 patients with various biphasic rub patterns there was summation of the ventricular diastolic rub with the atrial systolic rub, concealing an additional 10 percent of potential triphasic friction. Fourteen of 15 monophasic rubs were audible or recordable only during ventricular systole. Rubs were best heard along the left sternal border in 84 percent of cases and tended to be louder during inspiration than during expiration; in 35 cases there was no respiratory predilection. Twenty-three rubs were palpable. Ten rubs occurred in patients with pericardial effusion, five of whom had tamponade. Extension of the neck did not have a dependable effect on rub intensity.

Cardiac Tamponade↗

Pacemaker-induced endocardial friction rub.

Two patients had a typical sounding cardiac friction rub after placement of a temporary transvenous pacemaker. Absence of myocardial perforation was documented in one patient during thoracotomy for placement of an epicardial electrode and in the other with an electrogram recorded from the pacemaker as it was being withdrawn. The rubs disappeared during pacemaker removal. These cases are believed to represent endocardial friction rubs resulting from contact of the pacing wire with the endocardium.

Adult↗

The influence of air friction in speed skating.

With the use of a wind tunnel the air friction force Fw on six speed skaters of different body builds was measured. The dependence of the drag coefficient CD on air velocity v and the influence of different skating postures on drag were investigated. At an air velocity of v = 12 m/sec, an angle between upper and lower leg of 110 degrees and a horizontal trunk position, the measured air friction constant kn(=Fw/V2) of all subjects was calculated from their height l and weight m according to the formula 0.0205 l3 square root m (standard error 2%). CD and as a consequence k appeared to be strongly dependent on air velocity. Expressions to correct k for other velocities and postures were derived and substituted into a power balance by which the influence of posture, ice condition, wind and altitude on performance was predicted.

Air↗