Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Food Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Multiplex polymerase chain reaction and ligation detection reaction/universal array technology for the traceability of genetically modified organisms in foods.

A multiplex polymerase chain reaction (PCR) system was developed for the simultaneous detection of target sequences in genetically modified soybean (Roundup Ready) and maize (MON810, Bt176, Bt11, and GA21). Primer pairs were designed to amplify the junction regions of the transgenic constructs analyzed and the endogenous genes of soybean (lectin) and maize (zein) were included as internal control targets to assess the efficiency of all reactions. This multiplex PCR has constituted the basis for an efficient platform for genetically modified organism traceability based on microarray technology. In particular, the ligation detection reaction combined to a universal array approach, using the multiplex PCR as target, was applied. High specificity and sensitivity were obtained.

DNA, Plant↗

Heavy and toxic metals in staple foodstuffs and agriproduct from contaminated soils.

This article presents basic data on the content of Cr, Fe, Ni, Cu, Zn, As, Cd, Sb, Hg, and Pb in staple foodstuffs and agriproduct grown in Russia (Astrakhan region and the town of Belovo) and Egypt (Helwan region). The dependence of the concentration of metals in agriproducts on the content and chemical form of existence in irrigation water and soils is indicated.

Consumer Product Safety↗

Enumeration of Escherichia coli in cooked and raw meats by ion mobility spectrometry.

A novel method for enumerating Escherichia coli in foods is described. It is based on the production of o-nitrophenol (ONP) from o-nitrophenyl-beta-D-glucuronide as detected by an ion mobility spectrometer. The time taken for the detection of ONP in a food sample was inversely proportional to the logarithm of the initial E. coli population. Escherichia coli could be detected at a level of 10 g-1 within 9 h.

Animals↗

DNA methods: critical review of innovative approaches.

The presence of ingredients derived from genetically modified organisms (GMOs) in food products in the market place is subject to a number of European regulations that stipulate which product consisting of or containing GMO-derived ingredients should be labeled as such. In order to maintain these labeling requirements, a variety of different GMO detection methods have been developed to screen for either the presence of DNA or protein derived from (approved) GM varieties. Recent incidents where unapproved GM varieties entered the European market show that more powerful GMO detection and identification methods will be needed to maintain European labeling requirements in an adequate, efficient, and cost-effective way. This report discusses the current state-of-the-art as well as future developments in GMO detection.

DNA, Plant↗

Capillary electrophoresis of peptides and proteins in isoelectric buffers: an update.

Capillary electrophoresis in acidic, isoelectric buffers is a novel methodology allowing fast protein and peptide analysis in uncoated capillaries. Due to the low pH adopted and to the use of dynamic coating with cellulose derivatives, silanol ionization is essentially suppressed and little interaction of macromolecules with the untreated wall occurs. In addition, due to the low conductivity of quasi-stationary, isoelectric buffers, high-voltage gradients can be applied (up to 800 V/cm) permitting fast peptide analysis with a high resolving power due to minimal diffusional peak spreading. Four such buffers are here described: cysteic acid (Cys-A, pI 1.85), iminodiacetic acid (IDA, pI 2.23), aspartic acid (Asp, pI 2.77) and glutamic acid (Glu, pI 3.22). A number of applications are reported, ranging from food analysis to the study of folding/unfolding transitions of proteins.

Animals↗

Expression of results with uncertainty for the determination of pesticides in melon--experience in a proficiency test.

The expression of results with an uncertainty through the "bottom-up" approach, involving the estimation and combination of all the sources of uncertainty, represents a challenge when the analytical method includes mass transfer steps (MTS). These steps (e.g. extraction, evaporation, digestion, etc.) with inherently different from 100% recoveries lack models capable of describing their precision and efficiency. Recently, a new methodology was published aimed at the estimation of the performance of these critical steps. Comparison of the experimental dispersion from the replicated analysis of spiked samples with the combination of the uncertainty associated with gravimetric, volumetric and instrumental quantification steps (described by well established models) allows the estimation of the MTS uncertainty. Evaluation of the behaviour of the MTS within the analytical range supports the use of developed estimations over a wide concentration range. This methodology was applied, with success, to the determination of pesticide residues in melon in one particular proficiency test organised by the Food Analysis Performance Assessment Scheme (FAPAS) between November 2000 and February 2001.

Chromatography, Gas↗

Modern immunoassays in meat-product analysis.

The increased regulation of foodstuffs in modern society requires analytical methods which are easy to perform, sensitive, specific and relatively inexpensive. The basic antigen-antibody reaction provides means for very specific analytical procedures. Immunoassays are powerful analytical tools that permit the specific and rapid detection or measurement of antigens and haptens to which antibodies can be produced. Sensitive recognition of the interaction is made possible by labelling the analyte or antibody, mainly with radioisotope (RIA) and enzyme (ELISA). Wide applications of these modern immunoassays to food analysis began about 1980. The paper reviews investigations, where various types of RIA and ELISA were developed for the use in meat product analysis. Detection and determination of various meat species, non-meat proteins, microorganisms and bacterial toxins, drugs, anabolic hormones, pesticides, mycotoxins, and other contaminants in meat and meat products by the means of immunoassays is described. Now, the commercial kits are available for most of these compounds. They make possible to perform analysis in different laboratories under standard conditions. The reason of an enthusiasmic acceptance of this technology is related to its inherent specificity, high sensitivity, and the facility of application. In fact, immunoassays compete with other analytical technics. They have the advantage of economy when screening large numbers of samples.

Animals↗

Solid-phase microextraction in biomedical analysis.

Chromatographic methods are preferred in the analysis of organic molecules with lower molecular mass (<500 g/mol) in body fluids, i.e., the assay of drugs, metabolites, endogenous substances and poisons as well as of environmental exposure by gas chromatography (GC) and liquid chromatography (LC), for example. Sample preparation in biomedical analysis is mainly performed by liquid-liquid extraction and solid-phase extraction. However, new methods are investigated with the aim to increase the sample throughput and to improve the quality of analytical methods. Solid-phase microextraction (SPME) was introduced about a decade ago and it was mainly applied to environmental and food analysis. All steps of sample preparation, i.e., extraction, concentration, derivatization and transfer to the chromatograph, are integrated in one step and in one device. This is accomplished by the intelligent combination of an immobilized extraction solvent (a polymer) with a special geometry (a fiber within a syringe). It was a challenge to test this novel principle in biomedical analysis. Thus, an introduction is provided to the theory of SPME in the present paper. A critical review of the first applications to biomedical analyses is presented in the main paragraph. The optimization of SPME as well as advantages and disadvantages are discussed. It is concluded that, because of some unique characteristics, SPME can be introduced with benefit into several areas of biomedical analysis. In particular, the application of headspace SPME-GC-MS in forensic toxicology and environmental medicine appears to be promising. However, it seems that SPME will not become a universal method. Thus, on-line SPE-LC coupling with column-switching technique may be a good alternative if an analytical problem cannot be sufficiently dealt with by SPME.

Body Fluids↗

Polymerase chain reaction techniques for food allergen detection.

Food allergies represent an important health problem in industrialized countries. Undeclared allergenic foods as contaminants in food products pose a major risk for sensitized persons. Reliable detection and quantification methods for food allergens are necessary to ensure compliance with food labeling and improve consumer protection. The methods currently used for the detection of potential allergens in foods are to target either the allergen itself or a marker that indicates the presence of the offending food. As markers for the presence of potentially allergenic foods or ingredients, specific proteins or DNA fragments are targeted. In routine food analysis, the enzyme-linked immunosorbent assay (ELISA) and the polymerase chain reaction (PCR) in the form of a real-time PCR or in combination with an ELISA have been used. The availability, the characteristics, and some future aspects of DNA-based methods in the rapid and sensitive detection of potentially allergenic food constituents or contaminations are discussed in this review.

Allergens↗

DNA arrays, electronic noses and tongues, biosensors and receptors for rapid detection of toxigenic fungi and mycotoxins: a review.

This paper presents an overview of how microsystem technology tools can be applied to the development of rapid, out-of-laboratory measurement capabilities for the determinations of toxigenic fungi and mycotoxins in foodstuffs. Most of the topics discussed are all under investigation within the European Commission-sponsored project Good-Food (FP6-IST). These are DNA arrays, electronic noses and electronic tongues for the detection of fungal contaminants in feed, and biosensors and chemical sensors based on microfabricated electrode systems, antibodies and novel synthetic receptors for the detection of specific mycotoxins. The approach to resolution of these difficult measurement problems in real matrices requires a multidisciplinary approach. The technology tools discussed can provide a route to the rapid, on-site generation of data that can aid the safe production of high-quality foodstuffs.

Biosensing Techniques↗

Food contamination by ochratoxin A in Germany.

The results of studies reported in the literature on the occurrence of ochratoxin A in central Europe have been evaluated. Only data that were obtained from random samples were included, thus excluding those derived from samples suspected of being contaminated. Of 1100 samples of cereals (other than maize) and cereal products, 113 (10.3%) were contaminated with an average of 3.8 micrograms/kg. Of 325 samples of sausages containing porcine serum, 58 (17.8%) were contaminated, at an average of 0.15 micrograms/kg. The daily intake of ochratoxin A, calculated on the basis of information on consumption of such products, is 80 ng with cereals and 1.6 ng with sausages, corresponding to about 1 ng/kg body weight. People who consume maize products, corresponding to about 40 g maize per day, would take in a further 150 ng/day or 2 ng/kg body weight. These findings and the report that the biological half-life of ochratoxin A in Macaca mulatta is about 510 h, explain the fact that more than 50% of samples of human blood and serum tested contain ochratoxin A. As the levels of ochratoxin A in food are not subject to legal regulation in Germany, systematically collected data are not yet available.

Animal Feed↗

Detection of noroviruses in raspberries associated with a gastroenteritis outbreak.

Following an acute foodborne gastroenteritis outbreak in southern Sweden, stool specimens from five of nine ill patients were found positive for norovirus using reverse transcriptase polymerase chain reaction. Epidemiological data pointed to raspberry cakes as the source of the outbreak. Using a combination of generic and patient-specific primers and novel food analysis methodology (with extraction efficiency control and inhibitor removal), norovirus strains from two different genogroups were directly identified in the contaminated raspberries.

Caliciviridae Infections↗