Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Vitamins B1 and B6 tubular electrodes as FIA detectors; their use in the analysis of pharmaceutical products.

Ion-selective electrodes without an inner reference solution and tubular potentiometric detectors for the determination of vitamins B1 and B6 in pharmaceutical preparations by flow injection analysis (FIA) are reported. The membranes were prepared with the vitamin tetra(2-chlorophenyl)borate (TCPB) dissolved in o-nitrophenyloctyl ether (o-NPOE) and immobilized on PVC. Intrinsic behaviour of the tubular detectors was assessed using a low-dispersion single-channel FIA manifold and was compared with conventionally-shaped electrodes using the same membrane. Data obtained in the determination of vitamins B1 and B6 in pharmaceutical preparations with a double channel flow injection manifold incorporating the tubular detectors are presented and compared with those obtained by the U.S. Pharmacopeia method and by direct potentiometry with conventionally-shaped electrodes.

Electrodes↗

Peroxidase- and tetracyanoquinodimethane-modified graphite paste electrode for the measurement of glucose/lactate/glutamate using enzyme-packed bed reactor.

A flow injection analysis sensor for the measurement of glucose/lactate/glutamate is reported. The glucose oxidase/glutamate oxidase/lactate oxidase was immobilized on silanized controlled pore glass particles and packed into a Teflon column (i.d., 1.2 mm; length, 40 mm) to give a bed for glucose/lactate/glutamate. The hydrogen peroxide formed by the enzymatic reaction in the packed bed was monitored by a horseradish peroxidase- and tetracyanoquinodimethane (TCNQ)- modified graphite paste electrode at 50 mV vs Ag/AgCl. The glucose oxidase/lactate oxidase/glutamate oxidase were regenerated in the packed bed, whereas peroxidase was regenerated in the TCNQ-mediated graphite paste electrode by the oxidation of TCNQ. The oxidized TCNQ was electrochemically reduced at 50 mV vs Ag/AgCl. The cathodic current obtained by the reduction of TCNQ determined the concentration of the injected analytes in the packed bed. The system showed very rapid response. Response curves for the analysis of peroxide, glucose, lactate, and glutamate are reported.

Biosensing Techniques↗

Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide.

A novel method for immobilization of acetylcholinesterase (AChE) by binding covalently to a cross-linked chitosan-multiwall carbon nanotube (MWNT) composite is described. In addition a sensitive, fast, cheap and automatizable flow injection detection of an organophosphorous insecticide was developed. The MWNTs were homogeneously distributed in the chitosan membrane which showed a homogeneous porous structure. The immobilized AChE could catalyze the hydrolysis of acetylthiocholine with a K(M)app value of 177 microM to form thiocholine, which was then oxidized to produce detectable signal in a linear range of 1.0-500 microM and fast response. MWNTs could catalyze the electrooxidation of thiocholine, thus increasing detection sensitivity. Based on the inhibition of an organophosphorous insecticide on the enzymatic activity of AChE, using Sulfotep as a model compound, the conditions for the flow-injection detection of the insecticide were optimized. Both biocompatibility of chitosan and inherent conductive properties of MWNTs favored the detection of the insecticide from 1.5 to 80 microM along with good stability and reproducibility. 95 % reactivation from inhibited AChE could be regenerated by using 2-pyridinealdoxime methiodide within 15 min for 15 times. The detection of Sulfotep samples exhibited satisfactory results. The proposed flow-injection analysis device can be applied to automated determination and characterization of enzyme inhibitors.

Acetylcholinesterase↗

Chemiluminescence study of active oxygen species produced by TiO2 photocatalytic reaction.

Two chemiluminescence approaches have been used for study of active oxygen species produced by the TiO2 photocatalytic reaction. One is based on flow injection analysis (FIA)-luminol chemiluminescence (CL); another is a time-resolved CL method. In the FIA-CL experiment, an UV-illuminated TiO2 suspension and water were passed into a mixing cell by two separate flow lines. Luminol solution was injected into the water flow line at different times. The injected luminol reacted with active oxygen species generated by the TiO2 photocatalytic reaction in a mixing coil and produced CL. It was found that the maximum CL was detected at the first injection of luminol. CL intensity decreased with time of injection. When the luminol was injected after 5 min, the CL intensity was almost unchanged. Addition of scavengers of active oxygen species indicated that the CL produced early in the 5 min was caused by O2- and H2O2, while CL after 5 min was only from H2O2. In the time-resolved CL, the third harmonic wavelength of Nd:YAG laser (355 nm) was used as a UV light source, and CL was detected by a PMT and recorded in a millisecond time scale using a digital oscilloscope. It was found that CL induced by the photocatalytic reaction increased with concentration of the TiO2 suspension. Scavengers of active oxygen species of *OH, O2- and H2O2 were added to study the involvement of the active oxygen species.

Flow Injection Analysis↗

Determination of depolymerization kinetics of amylose, amylopectin, and soluble starch by Aspergillus oryzae alpha-amylase using a fluorimetric 2-p-toluidinylnaphthalene-6-sulfonate/flow-injection analysis system.

This study reports on the determination of the depolymerization kinetics of amylose, amylopectin, and soluble starch by Aspergillus oryzae alpha-amylase using flow-injection analysis with fluorescence detection and 2-p-toluidinylnaphthalene-6-sulfonate as the fluorescent probe. The experimental data points, corresponding to the evolution of the concentration of "detectable" substrate with depolymerization time, were fit to a single exponential decay curve in the case of amylose and to a double exponential decay curve in the cases of amylopectin and soluble starch. For all the assayed substrates, the determined depolymerization rates at time zero correlated well with the initial enzyme and substrate concentrations through the usual Michaelis-Menten hyperbola. Therefore, this methodology allows the determination of alpha-amylase activity using any of these substrates. For amylopectin and soluble starch, the value of the total depolymerization rate at any depolymerization time was the result of the additive contribution of two partial depolymerization rates. In contrast, the total depolymerization rate for amylose was always a single value. These results, in conjunction with the relative time evolution of the two partial depolymerization rates (for amylopectin and soluble starch), are in good agreement with a linear molecular structure for amylose, a "grape-like" cluster molecular structure for amylopectin, and an extensively degraded grape-like cluster structure for soluble starch.

Amylopectin↗

Theoretical consideration on polarized photometric detection.

Previously, we developed a novel detector, a polarized photometric detector for optically active compounds, where two polarizers are set on either side of the UV-visible absorbance detector flow cell. In this paper, we present theoretical considerations on this method with several equations. If the inclined angle of the second polarizer is defined as alpha (left when alpha > 0 degree), the following equation is obtained: delta Abs = 2 log e.tan alpha.beta, where delta Abs is the change in absorbance and beta (magnitude of beta << alpha) is the angle of rotation of light passing through the cell containing the optically active compound. This equation suggests that delta Abs is proportional to the analyte concentration and that the dextro- and laevorotatory compounds are detected as positive and negative absorbance changes, respectively. The theoretical maximum signal to noise (S/N) ratio is obtained when alpha = 45 degrees (= 0.8 rad) and the smallest detection limit is 5 x 10(-5) degrees (S/N = 3) when the path length of the flow cell is 10 mm. This detector was successfully used in flow injection analysis (FIA) as well as HPLC for optically active compounds.

Chromatography, High Pressure Liquid↗

Flow injection determination of xanthine oxidase inhibitory activity and its application to food samples.

The enzyme xanthine oxidase (XOD) has been recognized as a key enzyme causing oxidative injury to tissues by ischemia-reperfusion. For this reason, XOD inhibitor, which effectively suppresses this enzyme, plays an important role in the inhibition of many diseases related to reactive oxygen species (ROS). In order to screen XOD inhibitors rapidly and conveniently, a novel assay using flow injection analysis (FIA) was proposed in the present investigation. To optimize the practical FIA system, we studied the effect of the reagent concentrations and the flow condition on the enzymatic reaction, and then selected the optimum condition as follows: 200-mU/ml XOD concentration, 0.5-mM xanthine concentration, 0.5-ml/min flow rate, and 2-m mixing coil length. Under this condition, a typical XOD inhibitor quercetin was determined in the concentration range 0.1 - 1.5 mM at a sampling frequency of 10 samples/h. Using the optimized FIA method, we determined the XOD inhibitory activity of some food samples: onions, apples and teas, which are the high sources of flavonoids known as the potential XOD inhibitors. Among these samples, tea leaves showed the highest activity, the second was onions and the lowest was apples. Based on the result of the assay, not only quercetin, but also other components in investigated samples, contributed to the XOD inhibitory activity.

Allopurinol↗

Chiral analysis by mass spectrometry using the kinetic method in flow systems.

Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation. The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A significant improvement in accuracy using this procedure was achieved. Applicability of the method was demonstrated in the analysis of amino acids using FIA as well as HPLC/MS. After an achiral separation of leucine and isoleucine, chiral mass spectrometric detection was successfully used for enantiomeric recognition.

Algorithms↗

Determination of vitamin B6 in pharmaceutical formulations by flow injection-solid phase spectrophotometry.

In this work, a new solid phase spectrophotometric method in association with flow injection analysis for Vitamin B6 (pyridoxine) determination has been developed with direct measurement of light-absorption in C18 material. In the developed method, successive passage of the complex, previously formed in the flowing stream, and eluent through the flow cell and continuous monitoring of the process provided the analytical information needed to determine pyridoxine. Pharmaceutical samples containing Vitamin B6 were previously dissolved in 0.1 mol l(-1) phosphate buffer solution (pH 7.5) and a sample volume of 235 microl was injected directly into carrier stream consisting of a mixture of methanol and 0.1 mol l(-1) phosphate buffer solution adjusted to pH 7.0 (1+1, v/v). The blue indophenol dye produced from the reaction between pyridoxine and N,N-diethyl-p-phenylenediamine after oxidation by potassium hexacyanoferrate(III) was quantitatively retained on C18 support and the spectrophotometric detection was performed simultaneously at 633 nm. The retained complex was quickly eluted from C18 material with the eluent stream consisting of a mixture of methanol and 0.01 mol l(-1) HCl (6+4, v/v). The results showed that the proposed method is simple, rapid and the analytical response is linear in the concentration range of 0.5-10 and 0.2-4 mg l(-1) using 235 and 860 microl of sample, respectively. The limits of detection are 0.15 and 0.060 mg l(-1) and the R.S.D. are 3.6% (at 2 mg l(-1) level) and 4.0% (at 1 mg l(-1) level) using sample volume of 235 and 860 microl, respectively. The system presented an analytical throughput of 15 determinations per hour when a sample volume of 235 microl was utilized. The procedure was successfully applied to the determination of Vitamin B6 in pharmaceutical formulations containing vitamins of B group and others active principles such as Vitamin C and minerals.

Chemistry, Pharmaceutical↗

Voltammetric and flow amperometric methods for the determination of melatonin in pharmaceuticals.

Melatonin can be sensitively detected in pharmaceuticals by two different and simple electrochemical methods: cyclic voltammetry (CV) and amperometric detection in a flow injection analysis system (FIA-ED). An adequate pre-treatment of the carbon paste electrode in the first case and the employ of a high flow rate in the second one were the key for obtaining a very good reproducibility (R.S.D. values of 1.5 (n=10) and 1.3% (n=20), respectively). Low limits of detection were achieved and with the coupling of a flow system a linear dynamic range of three orders of magnitude (from 10(-8) to 10(-5) M) was obtained. Both methods were applied to the determination of melatonin in pharmaceuticals. In order to best validate these methodologies a fluorescent procedure was developed to contrast the results. As no interferences from the matrix were found the employ of a separation technique is not necessary. In this way the procedure is fastened and simplified. Moreover, the low price, ease of handling, possibility of automation and high sample throughput are important advantages that convert the flow methodology in an attractive alternative for quality control of pharmaceuticals.

Antioxidants↗

Electrospray ionisation-mass spectrometry of hydroxamate siderophores.

Electrospray ionisation-mass spectrometry (ESI-MS) was applied to the detection of the iron complexes of the hydroxamate type siderophores ferrioxamine (FO), ferrichrome (FC) and iron(III) rhodotoluate (FR). Mass spectra of the three siderophores produced by ESI-MS were dominated by the protonated (M + 1)+ parent ions, except for FR at pH 4.3, which was present as the positively charged 1:1 complex. On collision with He ions, fragmentation proceeded largely via cleavage of C-N bonds. Flow injection analysis of the siderophores with detection by ESI-MS produced detection limits of 1.9 fmol for FO, 31.1 fmol for FC and 524 fmol for FR.

Deferoxamine↗

Reduction of signal suppression effects in ESI-MS using a nanosplitting device.

Electrospray ionization mass spectrometry is a valuable tool in the identification and quantification of drug metabolites in biological fluids. However, there are many instances where matrix components present in these fluids interfere with analyte detection and prevent the acquisition of accurate or complete results. In some instances, the matrix can suppress ionization to such an extent that analytes are completely undetectable by MS. In this work, we investigate how ionization and ion-transfer efficiencies are affected by drastically reducing the flow into the MS. A postcolumn concentric flow-splitting device was constructed to allow the measurement of analyte signal and ionization suppression across a range of flow rates (0.1-200 microL/min). Using this device, the effects of flow rate on signal intensity and ionization suppression were measured in analytical experiments that included flow injection analysis MS, postcolumn addition LC-MS, and on-line LC-MS analysis of metabolites generated from rat liver microsomes. The device used to deliver 0.1 microL/min flows is referred to as a nanosplitter because it achieved high split ratios (2000:1), producing flow rates comparable to those observed in nanoelectrospray. The nanosplitter maintained chromatographic integrity with high fidelity and allowed the direct comparison of analyte signal across a range of flow rates (0.1-200 microL/min). A significant improvement in concentration and mass sensitivity as well as a reduction in signal suppression is observed when the performance at 200 versus 0.1 microL/min flow rate is compared. Using this specially designed concentric splitting device, the advantages of ultralow flow ESI were easily exploited for applications employing large bore chromatography.

Animals↗

Toward single-calibrant quantification in HPLC. A comparison of three detection strategies: evaporative light scattering, chemiluminescent nitrogen, and proton NMR.

There is an urgent need for detection technologies that enable accurate and precise quantification of solutions containing small organic molecules in a manner that is rapid, cheap, non-labor-intensive, readily automated, and without a requirement for specific analyte standards. We provide a theoretical analysis that predicts that the logarithmic nature of the working domain of the evaporative light-scattering detector (ELSD) will normally bias toward underestimation of chromatographically resolved impurities, resulting in an overestimation of analyte purity. This analysis is confirmed by experiments with flow injection analysis (FIA) and gradient reversed-phase high performance liquid chromatography (RP-HPLC). Quantification is further compromised by the dependence of response parameters on the matrix composition and hence on the retention time of the analyte. Attempts were made to ameliorate these problems by using the response surface of a single compound to calibrate throughout the HPLC gradient. A chemiluminescent nitrogen detector (CLND) was also used in a similar manner, and the performance of the two techniques were compared against those of each other and that of a reference standard technique. A protocol for this purpose was developed using proton nuclear magnetic resonance (1H NMR) and the ERETIC method to enable quantification by integrating proton signals. The double-blind comparison exercise confirmed molar nitrogen CLND response to be sufficiently stable and robust across a methanol gradient to be used with a single external nitrogenous calibrant to quantify nitrogen-containing compounds of known molecular formula. The performance of HPLC-CLND was very similar to that of NMR, while that of HPLC-ELSD was seen to be significantly worse, showing it to be unsuitable for the purpose of single-calibrant quantification. We report details and experience of our use of RP-HPLC-CLND-MS to characterize and quantify small amounts of solutions of novel compounds at nominal levels of 10mM in microtiter plate (MTP) format.

Journal Article↗

On-line monitoring of the methanol concentration in Pichia pastoris cultures producing an heterologous lipase by sequential injection analysis.

An automated sequential injection analysis (SIA) system using stop-flow technique was developed to determine methanol concentration by means of the enzymatic reactions of alcohol oxidase and peroxidase. Its application as an on-line device for monitoring Pichia pastoris fermentations producing an heterologous protein was demonstrated. Linear response, observed up to 2 g l(-1), was reached by including a dilution chamber in the SIA manifold. The sampling frequency was 7 analyses per hour with a relative standard deviation lower than 4%.

Bioreactors↗

Analysis of thiols with tyrosinase-modified carbon paste electrodes based on blocking of substrate recycling.

The enzyme, tyrosinase, was immobilized inside carbon paste electrodes (CPE) for the analysis of thiol-containing compounds such as the reduced form of glutathione (GSH) and L-cysteine. The measuring principle of this sensor is based on the blocking of the substrate recycling process between the enzyme and the electrode. The current response is monitored at -0.050 V versus Ag/AgCl. At this low potential, interferences from easily oxidizable species such as ascorbic acid and uric acid are minimized. The tyrosinase CPE is characterized both in steady state experiments and by flow injection analysis (FIA). GSH is used as the model thiol-containing compound for the study. The highest response for GSH was obtained around pH 6.5. A detection limit of 100 nM and 1 microM is achieved for GSH in steady state and in flow measurements, respectively. The analytical range for GSH is dependent on the concentration of the tyrosinase substrate (catechol). In steady state experiments, and at a lower substrate concentration (10 microM catechol), a linear range of 1-8 microM is found for GSH as compared with 5-30 microM at a higher substrate concentration of 20 microM catechol. Current response of the tyrosinase CPE is not affected by the oxidized form of GSH and L-cysteine (glutathione disulfide, GSSG, and L-cystine, respectively) and sulfur-containing compound such as methionine. The tyrosinase CPE can also detect coenzyme A, which makes it possible to construct biosensors based on enzymes producing or utilizing coenzyme A.

Biosensing Techniques↗

FIA acid-base titrations with a new flow-through pH detector.

A pH-sensitive detector for flow-through potentiometry based on a graphite/quinhydrone composite electrode was applied for flow-injection analysis (FIA) titrations. Hydrochloric acid and acetic acid were titrated by injection of samples into a sodium hydroxide carrier solution. System conditions were optimised by variation of flow rate, injection volume and titrant concentration. The parameters sampling frequency, residence time and dispersion coefficient were determined. The evaluation of peak width (time between the two inflection points on each side of the peak), peak area and slope of the raising edge of the peak lead were studied with respect to their use for calibration. Hydrochloric acid and acetic acid could be titrated down to a concentration of 2 x 10(-4) mol L(-1) using 150-microL injection volumes, which is almost ten times lower than can be achieved using colour indicators and a spectrophotometric detection.

Acetic Acid↗

Flow-injection amperometric determination of dopamine in pharmaceuticals using a polyphenol oxidase biosensor obtained from soursop pulp.

The amperometric determination of dopamine (Do) in pharmaceuticals formulations by flow injection analysis (FIA) is proposed. An enzymatically modified carbon paste electrode constituted by 25% (w/w) of polyphenol oxidase obtained from Annona muricata L. tissue, 30% (w/w) of graphite, 30% (w/w) of silicone and 15% (w/w) of 7,7,8,8 tetracyanoquinodimethane (TCNQ), was used as flow-through detector. The flow amperometric detection was carried out at a potential of 0.10 V (vs. Ag/AgCl) when an injected sample volume of 250 microl was inserted on a 0.3 M phosphate buffer carrier solution (pH 7.8) flowing at 2.5 ml/min. The developed biosensor showed good stability and reproducibility, enabling up to 500 determinations in 60 days, without considerable loss of enzymatic activity. The FIA system presented a linear response to Do concentrations in the interval from 2 x 10(-2) to 2 x 10(-4) M, with relative standard deviations lower than 1.5%. The kinetic parameter K(M) for the soluble and immobilized enzyme was 1.45 x 10(-2) and 1.91 x 10(-2) M, respectively. In the analyses of different commercially pharmaceutical formulations a relative deviation lower than about 3.4% was obtained.

Annona↗

Development of a biparametric bioanalyser for creatinine and urea. Validation of the determination of biochemical parameters associated with hemodialysis.

The construction and evaluation of an automated urea and creatinine biparametric biosystem using flow injection analysis (FIA) are described. The biosystem uses enzyme reactions that hydrolyse urea and creatinine producing ammonium ions. The enzymes used were creatinine deiminase and urease, which are immobilized covalently in flow reactors. The reactor with creatinine deiminase has the enzyme immobilized on controlled-pore glass beads, whereas urease is immobilized on a nylon open tubular reactor. Detection is realised with a flow-through ammonium ion-selective electrode with an inner solid-state contact (graphite-epoxy composite). Ammonium ions are separated from alkali ion interferents through a gas-diffusion cell. The bioanalyser is fully automated using software and electronics developed ex profeso in our laboratories. The analyser was validated off-line by measuring urea and creatinine from discrete effluent samples from hemodialysis equipment. Results agreed with concurrent analyses realised using hospital laboratory methods. There were no significant differences between the two sets of results at the 95% confidence level. Finally, the biparametric bioanalyser was validated on-line by measuring creatinine and urea levels in artificial kidney effluents. These measurements were useful in the determination of key biochemical parameters of clinical interest such as the mass of urea and creatinine extracted from the patient as well as the initial concentration of creatinine and urea in blood plasma. When the results of the bioanalyser were compared with those yielded by the usual methods, they showed no significant differences at the 95% confidence level when determining the mass of the analytes extracted by the hemodialyser or when determining the urea concentration in blood plasma. However, when measuring the creatinine concentration in blood plasma using the developed bioanalyser, significant differences appeared.

Biological Assay↗