Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FILTRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Glomerular filtration rate and segmental tubular function in the early phase after transplantation/uninephrectomy in recipients and their living-related kidney donors.

1. Glomerular filtration rate and sequential tubular function were investigated in 18 adult renal transplant recipients and in their matched, adult living-related kidney donors before and 5 days after transplantation/uninephrectomy. At day 54, 13 donors and 11 recipients were re-investigated. Sixteen of these constituted eight matched pairs. This reduction in the study population was caused by the application of two withdrawal criteria. 2. In the recipients glomerular filtration rate was unchanged at day 5 and had increased to 61 ml/min at day 54 (P < 0.05). In the donors glomerular filtration rate had increased to 59 ml/min by day 5 (P < 0.01) and was unchanged at day 54. 3. In the recipients lithium clearance was unchanged at day 5 and had increased to 23 ml/min at day 54 (P < 0.01). In the donors the lithium clearance had increased by day 5 (P < 0.01). 4. In the recipients the absolute proximal fluid reabsorption rate was about 36 ml/min throughout the study period. In the donors the absolute proximal fluid reabsorption rate had increased to 42 ml/min by day 5 (P < 0.05) and increased further to 44 ml/min by day 54 (P < 0.01). 5. In the recipients sodium clearance increased from 0.54 ml/min to 2.10 ml/min at day 54 (P < 0.01). In the donors it increased from 0.64 ml/min to 0.99 ml/min at day 54 (P < 0.05). 6. Donor-recipient comparison showed that at day 54 there was no significant difference with regard to glomerular filtration rate, lithium clearance, absolute and fractional proximal fluid reabsorption rate and absolute distal sodium reabsorption rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Leukocyte filtration of single-donor platelet units through an integrated filter system for the Fresenius AS 104 blood cell separator.

BACKGROUND AND OBJECTIVES: White cell depletion of platelet concentrates is widely applied to reduce the incidence of transfusion complications. We investigated a new plateletpheresis kit with an integrated filter for leukocyte depletion of platelets. MATERIALS AND METHODS: Parameters of product quality were investigated before and after in-line filtration of 70 single-donor platelet (SDP) units obtained by apheresis. We studied three different filter batches manufactured for the Fresenius AS 104 blood cell separator, and evaluated different softwares and interface positions with respect to platelet (PLT) yield and white blood cell (WBC) contamination. RESULTS: PLT yields before and after filtration was not statistically different in the protocols studied. WBC contamination after WBC depletion was in the range of 10(4)/SDP unit. Glucose, lactate dehydrogenase, and the morphology score were not statistically different before and after filtration. CONCLUSIONS: In-line WBC filtration of SDP units sufficiently reduced WBC below 5 x 10(6)/unit. The study allowed definition of the filter composition and apheresis parameters to optimize PLT yield and minimize WBC contamination.

Filtration↗

Angiotensin-converting enzyme inhibition in adult hypertensive rats: a stereological study of renal filtration surface area.

1. Angiotensin-converting enzyme (ACE) inhibitor treatment leads to beneficial effects on kidney function. The aim of the present study was to determine whether ACE inhibition at high or low doses affects glomerular capillary surface area and length, glomerular number or total renal filtration surface area in rats with established hypertension and, if so, to determine whether these effects are mediated through bradykinin potentiation. 2. Spontaneously hypertensive rats (SHR) were treated with the ACE inhibitor perindopril at either 3 or 0.1 mg/kg per day (high and low doses, respectively) from 16 to 24 weeks of age. Some rats were concomitantly treated with the bradykinin B2 receptor antagonist S16118 (10 nmol/kg per day). Blood pressure was measured twice weekly during the treatment period. At 24 weeks of age, rats were perfusion fixed at 140 mmHg, the kidneys removed, embedded in resin and examined stereologically to estimate glomerular number and volume, length and surface area of glomerular capillaries and total renal filtration surface area. 3. High- and low-perindopril treatment significantly reduced systolic blood pressure compared with control SHR. However, the rats treated with low-dose perindopril were still considered hypertensive. Neither low-dose nor high-dose perindopril treatment had any observable effect on glomerular number (23 876 +/- 1201 vs 26 240 +/- 1465 glomeruli/kidney, respectively) or volume (2.25 +/- 0.21 and 1.96 +/- 0.06 x 10-3 mm3, respectively) compared with controls (glomerular number 25866 +/- 1210 glomeruli/kidney; glomerular volume 2.24 +/- 0.21 x 10-3 mm3). As a result, there was no significant difference in total renal filtration surface area between any of the experimental groups (8161.6 +/- 550.9, 8699.7 +/- 427.6, 9081.9 +/- 453.6, 8830.2 +/- 521.2 and 8559.4 +/- 341.4 mm2 for SHR, SHR low-dose perindopril, SHR low-dose perindopril + B2 antagonist, SHR high-dose perindopril and SHR high-dose perindopril + B2 antagonist, respectively). Coadministration of the bradykinin antagonist had no observable effect on any of the parameters studied. 4. In conclusion, because neither high-dose nor low-dose perindopril had any effect on total renal filtration surface area, the observed beneficial effects of ACE inhibition on kidney function are not the result of enhancement in glomerular capillary surface area.

Angiotensin-Converting Enzyme Inhibitors↗

Cerebrospinal fluid filtration in amyotrophic lateral sclerosis.

By means of a randomized, controlled and open study the authors wanted to find out if cerebrospinal (CSF)-filtration was of substantial benefit to patients with sporadic amyotrophic lateral sclerosis (SALS). Five SALS patients, aged 51-75 years, being treated with riluzole underwent CSF-filtration daily over five days (group A). Five other SALS patients, aged 52-70 years, were treated only with riluzole (group B). Although all five patients in the first group reported a subjective benefit following CSF- filtration, the Norris score, the Frenchay score, the vital capacity, the ulnar nerve F-wave persistence and the peak-ratio of the brachial biceps and anterior tibial muscles did not change significantly after five days of therapy, either in group A or in group B. In conclusion, filtration of 200-250 ml CSF daily, over five days, does not seem to have a substantial therapeutic effect in patients with SALS.

Aged↗

Effect of angiotensin-converting enzyme inhibition on renal filtration surface area in hypertensive rats.

BACKGROUND: Angiotensin-converting enzyme (ACE) inhibitor treatment leads to protective effects on the cellular structure of the glomerulus and the kidney. The aim of this study was to determine whether ACE inhibition increases renal filtration surface area in the spontaneously hypertensive rat (SHR). METHODS: SHR were treated with the ACE inhibitor perindopril at a high dose (3 mg/kg/day) or a low dose (0.1 mg/kg/day) during the period of hypertension development, from 7 to 14 weeks of age. Some animals were treated concomitantly with the bradykinin B2 receptor antagonist, S16118. Tail-cuff systolic blood pressure and body weights were measured twice weekly. At termination of treatment, glomerular number and volume, length, and surface area of glomerular capillaries and renal filtration surface area were estimated using unbiased stereological techniques. RESULTS: There were significant dose-related reductions in blood pressure with high- and low-dose perindopril treatment. Neither low- nor high-dose perindopril treatment had any effect on glomerular number or size or glomerular capillary length and surface area. Hence, there was no significant difference in total renal filtration surface area between any of the experimental groups (8721 +/- 610 mm2 in untreated SHR and 7879 +/- 338 mm2 and 8767 +/- 437 mm2 in the low and high dose perindopril-treated groups, respectively). Coadministration of the bradykinin antagonist did not affect any of the glomerular parameters. CONCLUSIONS: ACE inhibition during the period of hypertension development does not lead to an enhanced glomerular capillary growth or increases in total renal filtration surface area in this model.

Angiotensin-Converting Enzyme Inhibitors↗

A multicenter study on the efficiency of white cell reduction by filtration of red cells.

To evaluate accurately the current performance of filtration, the French Produits Sanguins Labiles study group, composed of 21 transfusion teams, conducted a large-scale 6-month study involving over 1400 filtrations and 3000 controls. Some 745 standard red cell concentrates (RBC concentrates) and 690 concentrates previously white cell (WBC)-reduced by removal of buffy coat (BC-poor RBC concentrates) were filtered using six commercially available filters: at least 170 results were collected per filter, spread among a minimum of three teams. Prefiltration controls show that the removal (manual and automated) of the buffy coat results in an initial WBC reduction of approximately 63 percent, along with a hemoglobin loss of 4 g (7%). After filtration, residual WBCs were counted in the Nageotte manual counting chamber. The reliability of this counting method, which is simple and adapted to low WBC concentrations, was characterized in this study by a 25-percent coefficient of variation (CV) for a concentration of 2.5 WBCs per microL (i.e, 0.6 x 10(6) WBCs/filtered unit). The analysis of the results shows that, for five of six filters (1 filter was excluded), the postfiltration median value of residual WBCs was 1.1 x 10(6) in filtered RBC concentrates (n = 590), whereas it was 0.34 x 10(6) in filtered BC-poor RBC concentrates (n = 581). The difference is significant (p less than 10(-8), Wilcoxon test). Hemoglobin loss due to filtration varies according to the filter, from 5.7 +/- 2.2 to 17.3 +/- 2.5 g.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Component Removal↗

In vitro evaluation of platelet concentrates, prepared from pooled buffy coats, stored for 8 days after filtration.

BACKGROUND: Posttransfusion complications can be prevented by pretransfusion removal of donor white cells from platelet concentrate. The filtration used for this removal seems to have little effect on platelet function and activation, but more information is needed on its effect on function during subsequent long-term storage of concentrate. STUDY DESIGN AND METHODS: The effect of prestorage filtration of buffy coat-prepared platelet concentrates (PCs) on platelet function, metabolism, and activation was investigated. A pool of three PCs, each made of four buffy coats, was split into three equal volumes; two were filtered over two different filters and the third served as a control. Variables monitored immediately after filtration and during the subsequent 8-day storage period at 22 degrees C included aggregation upon stimulation with collagen and/or ADP, platelet adhesion capacity to collagen and fibrinogen in flowing blood, nucleotide content of and nucleobase release by the platelets, expression of activation-dependent antigens, and beta-thromboglobulin release by the platelets. RESULTS: No differences were observed between the PCs filtered over two different filters and the nonfiltered control PCs immediately after filtration and during storage, except for a selective removal (20%) of beta-thromboglobulin by one filter. CONCLUSION: PCs prepared from a pool of four buffy coats can be filtered and subsequently stored for 8 days (starting +/- 24 hours after whole blood collection) without detriment to platelet function, metabolism, or activation.

Antibodies, Monoclonal↗

White cell-reduced platelet concentrates prepared by in-line filtration of platelet-rich plasma.

BACKGROUND: The importance of white cell (WBC) reduction in platelet concentrates (PCs) for component quality is undetermined. STUDY DESIGN AND METHODS: Eleven paired components, each derived from one of two whole-blood units given by a single donor on the same day, were studied. One PC was WBC reduced by filtration with an in-line, integral, prototype filter, and the other was produced from unfiltered platelet-rich plasma (PRP) by a standard method. In vitro tests performed on Day 1 and Day 5 were blood gases, plasma lactate, glucose, platelet ATP, mean platelet volume, morphology score, hypotonic stress ratio, extent of shape change in response to ADP, and beta-thromboglobulin. After 5 days of storage, each component pair was labeled with 51Cr or 111In and transfused for the estimation of percent recovery and survival. RESULTS: PCs using the in-line, prototypic filter had a platelet loss of approximately 15 percent and a variable 1 to 3 log10 reduction (average, 95%) in WBC content. The variation in filter WBC removal was related to PRP WBC content and indicated that the filter did not have the capacity for a 3 to 4 log10 removal when PRP WBC content exceeded 1 x 10(8). The in vitro and in vivo measures of platelet quality showed no meaningful differences between filtered and unfiltered PCs by paired t test. The mean differences in posttransfusion percent recoveries and survivals were 0.9 +/- 2.9 percent and 4 +/- 13 hours, respectively. Additional studies were performed using a larger filter with improved capacity. Those studies (n = 18) showed a significant improvement in filtration time and platelet yield and a consistent 3 to 4 log10 reduction in WBCs. Filtration time was 6.6 +/- 2.7 minutes, total PC WBCs were 9.6 +/- 4.6 x 10(4), and total PC platelets were 7.8 +/- 1.8 x 10(10) (mean +/- SD). CONCLUSION: Prestorage filtration of PRP and the preparation of filtered platelets do not result in any significant beneficial or adverse effect on subsequent platelet quality. With the large-capacity filter, consistent WBC reduction and good platelet yields are achieved.

Blood Donors↗

Activation of the contact system by filtration of platelet concentrates with a negatively charged white cell-removal filter and measurement of venous blood bradykinin level in patients who received filtered platelets.

BACKGROUND: Several recent reports have described hypotensive transfusion reactions in patients receiving platelet concentrates (PCs) filtered through white cell-reduction filters. It is well known that a negatively charged surface activates the contact system, consisting of factor XII, prekallikrein, and high-molecular-weight kininogen. STUDY DESIGN AND METHODS: To clarify the mechanisms of these hypotensive reactions, the possibility that white cell-reduction filtration activates the contact system was examined. Venous blood plasma bradykinin levels were also measured in patients receiving PC transfusions through filters. RESULTS: None of the measured values were changed by filtration through a positively charged filter. However, filtration through a negatively charged filter resulted in a decrease in the amounts of prekallikrein and an increase in the amount of bradykinin generated, which indicated the activation of the contact system. The bradykinin level was inversely related to the activity of angiotensin-converting enzyme (ACE) in the PCs and was elevated by addition of an ACE inhibitor. Although the venous blood plasma bradykinin level did not change in two patients with a normal ACE activity during PC transfusion through the negatively charged filter, two patients who had decreased ACE activity, showed a significant increase in bradykinin during the transfusion. CONCLUSION: These results suggest that the generation of a large amount of bradykinin by filtration of PCs through a negatively charged filter might cause hypotensive reactions in patients with decreased ACE activity. The clinical significance of bradykinin generation requires further study.

Aged↗

Effects of filtration and gamma radiation on the accumulation of RANTES and transforming growth factor-beta1 in apheresis platelet concentrates during storage.

BACKGROUND: Platelet-derived biologic response modifiers (BRMs) including RANTES and transforming growth factor (TGF)-beta1 accumulate in platelet components during storage because of platelet activation, and they may play a causative role in nonhemolytic febrile transfusion reactions. The majority of PCs with high unit values are provided by single donor apheresis in Japan. STUDY DESIGN AND METHODS: RANTES and TGF-beta1 levels in platelet units prepared from single-donor apheresis platelet concentrates (apheresis PCs) and units from whole blood (buffy coat PCs) were investigated. The effects of prestorage and poststorage filtration and gamma radiation on the levels of RANTES and TGF-beta1 in the supernatant of apheresis PCs during storage were also examined. RESULTS: The levels of RANTES and TGF-beta1 increased during storage from Day 0 to Day 5. The levels of RANTES and of TGF-beta1 correlated with the platelet concentration (p<0.01), but not with the residual white cell concentration in apheresis PCs that were not white cell reduced by filtration (p>0.05). In addition, there was a correlation between RANTES and TGF-beta1 levels (p<0.01). In white cell-reduced apheresis PCs using negatively charged filters as well as in gamma-radiated apheresis PCs, the levels of these two BRMs-did not differ at any storage time from those of untreated apheresis PCs. Filtration of apheresis PCs with negatively charged filters after 3 days of storage significantly (p<0.05) reduced the levels of RANTES, but not of TGF-beta1. There was no reduction in the levels of RANTES and TGF-beta1 levels by positively charged filters. The RANTES levels in buffy coat PCs were slightly higher than but not significantly different from those of apheresis PCs during storage, except for the level on Day 1. There were no differences in the TGF-beta1 levels in apheresis and buffy coat PCs during storage. CONCLUSION: Prestorage filtration and gamma radiation had neither preventive effects on the accumulation of RANTES and TGF-beta1 nor adverse effects on platelet activation. Negatively charged filters might be useful for the reducing the levels of RANTES in stored apheresis PCs.

Blood Donors↗

Human promyelocytic cell line: a convenient tool for studying the molecular basis of WBC filtration.

BACKGROUND: Blood filtration is a technique widely used to reduce the levels of WBCs in blood components. Several studies have been conducted to define the factors that are involved in WBC reduction, but the various mechanisms are not clearly delineated. This study explored the role of WBC adhesion molecules in WBC reduction during filtration. STUDY DESIGN AND METHODS: A minifilter has been developed that has properties similar to those of the standard filter (Sepacell, Asahi Medical) but that allows a smaller volume of blood to be used (15 mL). WBC reduction was achieved to a similar extent in the standard filter and the minifilter (4.15 log and 4.18 log, respectively). Samples of human promyelocytic cell line (HL60) were filtered before and after differentiation induced by vitamin D3 (D3-HL60). Flow cytometry was used to characterize the D3-HL60 filtrates and to count the WBCs after filtration. RESULTS: HL60 was retained in the filter to the same extent as all other WBCs. A higher level of integrin receptors (CD11b/CD18; CD11c/CD18) was expressed by D3-HL60 than by HL60. When the blood was incubated with anti-CD11b, anti-CD11c, or anti-CD18, fewer D3-HL60 cells were trapped by the filter, while only anti-CD11b alters HL60 retention in the filter. CONCLUSION: The receptors CD11b/CD18 and CD11c/CD18 appear to bind to the filter fibers and to be one of the mechanisms responsible for WBC retention.

Blood Platelets↗

WBC reduction in RBC concentrates by prestorage filtration: multicenter experience.

BACKGROUND: As universal leukocyte (WBC) reduction (ULR) is being considered as a new standard, few data are available on the performance of WBC-reduction filtration in routine practice. The performance of WBC-reduction in RBCs, using varied filtration practices, in meeting the current FDA requirement (<5 x 10(6)), Council of Europe (EC) recommendation, the proposed FDA requirement (<1 x 10(6)), and a more stringent proposal (<5 x 10(5)) for residual WBCs per RBC unit was assessed and compared. STUDY DESIGN AND METHODS: Participating facilities were the 11 sites of the Viral Activation Transfusion Study (VATS), a prospective study of the impact of transfusion with and without WBC-reduction on survival and HIV viral load in HIV-1-infected patients. Patients randomly assigned to undergo WBC reduction were required to receive RBCs < or =14 days old that had undergone prestorage (within 72 hours of collection) WBC-reduction filtration by a method devised to achieve a postfiltration WBC count of <5 x 10(6). Residual WBC quantitation was performed by PCR in the central VATS laboratory by using frozen WBC-reduced RBC samples obtained at issue for transfusion. RESULTS: A total of 1869 WBC-reduced RBC units were studied. Filtration practices varied within and between sites. There were significant differences in mean residual WBC counts at the 11 sites (p<0.001). Among the WBC-reduced RBC units, 0.8 percent exceeded 5 x 10(6) WBCs per unit, 8.3 percent exceeded 1 x 10(6) WBCs per unit, and 14.3 percent exceeded 5 x 10(5) WBCs per unit. CONCLUSION: Residual WBCs in WBC-reduced RBC units vary within and between sites. WBC reduction was successful, in that over 99 percent and 91 percent of VATS WBC-reduced RBC units met US and EC thresholds, respectively. However, the small but measurable failure rate indicates that not every unit will meet these guidelines.

Blood Component Removal↗

Production and recovery of human leukocyte-derived alpha interferon using a cascade filtration system.

The use of a cascade filtration system for production and recovery of human leukocyte-derived alpha interferon (HuIFN-alpha) has been investigated. Included in the investigation were mass transfer studies of HuIFN-alpha across ultrafiltration membranes, design and evaluation of a laboratory-scale production system and determination of IFN production kinetics in both batch and filtration systems. The cascade filtration system allows separation of interferon from leukocytes and virus during production with simultaneous concentration and complete recovery. Kinetic studies indicate that HuIFN-alpha production can be enhanced by appropriate timing of the filtration procedure. While the current study is concerned with HuIFN-alpha, it is expected that the techniques developed will be applicable to the production and recovery of both natural and recombinant IFNs and lymphokines in general.

Cell Survival↗

Rapid removal of heparin from plasma by affinity filtration.

Coagulation test abnormalities caused by the presence of heparin are not uncommon and frequently result in additional laboratory investigation and unwarranted therapy. Methods to neutralize the effect of heparin include the addition of polyanions, enzymes, or resins to the clinical samples. These techniques are time consuming and cumbersome and produce inconsistent results. As an alternative, use of a positively charged porous filtration medium to remove heparin from the sample is described. The filtration procedure requires less than one minute and provides a consistent and total removal of heparin at plasma concentrations in excess of therapeutic levels. Chromogenic substrate analysis for residual heparin activity confirms total removal of the drug at levels greater than one unit/mL of plasma. In clinical trials, filtration normalized the activated partial thromboplastin time (APTT) of all patient specimens containing heparin (n = 41). Filtration did not shorten the coagulation assay times of patients receiving warfarin (n = 36) or of those with a variety of acquired coagulopathies (n = 14). The level of coagulation factors adsorbed to the filter medium compares favorably to that adsorbed by other commercially available heparin-binding resins. Routine use of the filter in the clinical laboratory allows for the rapid and definitive identification of heparin in specimens with prolonged coagulation times and provides clinically meaningful data.

Blood Coagulation Factors↗

Glass wool filtration leads to a higher percentage of spermatozoa with intact acrosomes: an ultrastructural analysis.

We investigated the possibility of ultrastructural damage to human spermatozoa induced by different sperm preparation techniques. Ejaculates from 20 normozoospermic men were divided into equal aliquots and processed by glass wool filtration, Percoll density gradient centrifugation, and a simple two-step centrifugation procedure which served as a control. The evaluation of 60 spermatozoa from each of 20 test subjects (in all, n = 1200) ensured that a sufficiently large number of spermatozoa were investigated. Ultrastructural damage was assessed by scanning electron microscopy. We investigated the state of the acrosome after sperm preparation and measured the percentage of intact spermatozoal structures compared with that of the control. Compared with Percoll density gradient centrifugation, glass wool filtration yielded a significantly increased proportion of intact acrosomes. However, both preparations gave significantly better results than the control. In conclusion, both glass wool filtration and Percoll centrifugation are efficient techniques for the accumulation of spermatozoa with intact acrosomes. Because of the significantly higher percentage of intact acrosomes, glass wool filtration appears to be the more appropriate method. The significance of the conspicuous bending of sperm tails after Percoll centrifugation is not yet known.

Acrosome↗

Glass wool column filtration of human semen: relation to swim-up procedure and outcome of IVF.

The number and viability of spermatozoa recovered by glass wool column filtration and a swim-up procedure were compared using different types of ejaculates, such as normal, asthenozoospermic and very viscous oligozoospermic semen. The filtration procedure resulted in significantly (P less than 0.01) higher recovery of viable spermatozoa than the swim-up procedure from all types of ejaculates studied. Further, the spermatozoa from 50 (78.1%) of the 64 ejaculates filtered through glass wool column fertilized at least one intact human egg in an in-vitro fertilization (IVF) procedure. It is concluded that glass wool column filtration is superior to the swim-up procedure since it yields a higher recovery of viable spermatozoa that are potentially fertile. Therefore, the glass wool column filtration procedure used to prepare spermatozoa may be of benefit for IVF, intra-uterine insemination, in-vitro fertilization and GIFT (gamete intra-Fallopian transfer), especially in cases of poor quality semen.

Cell Separation↗

The influence of contrast medium dose on filtration fraction in the rabbit kidney.

We have examined the effect of dose on contrast medium-induced reductions in glomerular filtration in anesthetized rabbits. The fraction of renal plasma flow that is filtered, the filtration fraction, was directly measured by the renal arteriovenous difference method using technetium-99m (99mTc) (Sn) DTPA as the tracer, arterial and renal venous extracorporeal shunts, a gamma camera and a computer. Filtration fraction (FF) was measured each 30 seconds before and after contrast medium (sodium/methylglucamine diatrizoate) was injected in 15 seconds at a dose of 0.5, 1.0 or 2.0 ml/kg, IV. In six animals that had a control FF of 0.19 +/- 0.01 there was a dose-related decrease in FF. The largest dose reduced FF by 53.3%. In three other animals that had a low control FF (0.07 +/- 0.01), the largest dose induced an even greater 71.0% decrease in FF. These data suggest that attempts at increasing contrast excretion by injecting larger doses will be offset, at least in part, by larger reductions in glomerular filtration, and that this effect may be greater when glomerular function is impaired.

Animals↗

Filtration characteristics of the polyester fiber micropore blood transfusion filter.

The filtration characteristics of a new polyester fiber (Fenwal II) micropore blood transfusion filter were investigated. Filtration of stored human whole blood and packed cells resulted in return of screen filtration pressure (SFP) of the blood to normal. Increased filter weights verified removal of large amounts of debris and microaggregates from the blood. Filtration of large quantities of blood accomplished at very high flow rates did not adversely affect the composition of the filtered blood. We conclude that the polyester fiber (Fenwal II) micropore blood transfusion filter is effective in removing microaggregates from stored whole blood and packed cells. It has a high volume capacity, allows rapid flow, and is reliable during pressure transfusion.

Blood Banks↗