Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELECTRONICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Determination of coplanar and non-coplanar polychlorinated biphenyls in human serum by gas chromatography with mass spectrometric detection: electron impact or electron-capture negative ionization?

A time- and cost-saving method for the congener-specific analysis of polychlorinated biphenyls (PCBs) in human serum has been developed and validated. After two fast extraction and clean-up steps, analyses were performed using gas chromatography coupled with mass spectrometry with single ion monitoring (GC/SIM-MS), either in electron impact (EI) or electron-capture negative ionization (ECNI) mode. For the determination of dioxin-like congeners, an improvement in EI-MS sensitivity is desirable and use of NI is thus preferred. The procedure was validated for 12 dioxin-like congeners by analyzing spiked samples on three different days and using (13)C(12)-labelled analogues as internal standards. When using an NCI source, the limit of quantification was assessed at 0.01 microg/L, except for PCBs #77 and #81, which cannot be reliably detected below 0.05 microg/L. For the lower chlorinated non-dioxin-like congeners, NI offers less selectivity because of limited fragmentation. Electron impact ionization and electron-capture negative ionization mode can therefore be considered to be complementary for the determination of PCB congeners in the general population.

Dioxins↗

Microanalysis using secondary electrons in scanning electron microscopy.

A recent study of secondary electron (SE) spectra in an Auger spectrometer demonstrated unique features indicative of the chemical nature of the tested material. The scanning electron microscope (SEM) naturally generates SEs; therefore, in this paper, we combine the concept of using differential voltage contrast (DVC) with SE spectroscopy to identify the chemical nature of a material. It is demonstrated that this method reveals the uniqueness of electron energy distribution in the conduction band of a solid or, what is the same, the uniqueness of a build-up of the outer electron shell system, and avoids errors due to the changes in the angular distribution or yield of the SE in the SEM. A theory of this new microanalytical method is developed. The experimental limitations of the SEM for this type of study are examined as well.

Journal Article↗

Local recurrence rates in breast cancer patients treated with intraoperative electron-boost radiotherapy versus postoperative external-beam electron-boost irradiation. A sequential intervention study.

BACKGROUND AND PURPOSE: The purpose of this sequential intervention study was to determine the rate of local recurrences and the rate of distant metastases in patients with invasive breast cancer who had been treated with breast-conserving surgery and postoperative radiation therapy to the whole breast either with postoperative electron boost in group 1 or with intraoperative electron boost (IORT) in group 2. PATIENTS AND METHODS: After breast-conserving surgery, 378 women with invasive breast cancer of tumor sizes T1 and T2 received 51-56.1 Gy of postoperative radiation therapy to the whole breast in 1.7-Gy fractions. 188 of those patients additionally received a postoperative electron boost of 12 Gy in group 1 from January 1996 to October 1998. Consecutively, from October 1998 to March 2001, 190 patients received intraoperative electron-boost radiotherapy of 9 Gy to the tumor bed in group 2. The groups were comparable with regard to age, menopausal status, tumor size, grading, and nodal status. All statistical tests were two-sided. RESULTS: During a median follow-up period of 55.3 months in group 1 and 25.8 months in group 2, local recurrences were observed in eight of 188 patients (4.3%) in group 1, and no local recurrence was seen in group 2 (p=0.082). Distant metastases occurred in 15 of the 188 patients (7.9%) in group 1 and in two of the 190 patients (1.1%) in group 2 (p=0.09). The 4-year actuarial rates of local recurrence were 4.3% (95% confidence interval, 1.8-8.2%) and 0.0% (95% confidence interval, 0.0-1.9%) and the 4-year actuarial rates of distant metastases were 7.9% (95% confidence interval, 4.5-12.8%) and 1.1% (95% confidence interval, 0.1-3.8%). CONCLUSION: Immediate IORT boost yielded excellent local control figures in this prospective investigation and appears to be superior to conventional postoperative boost in a short-term follow-up.

Adult↗

Rubber particles from four different species, examined by transmission electron microscopy and electron-paramagnetic-resonance spin labeling, are found to consist of a homogeneous rubber core enclosed by a contiguous, monolayer biomembrane

The physical characteristics of rubber particles from the four rubber (cis-1,4-polyisoprene) producing species Euphorbia lactiflua Phil., Ficus elastica Roxb., Hevea brasiliensis Mull. Arg., and Parthenium argentatum Gray, were investigated using transmission electron microscopy (TEM) and electron-paramagnetic-resonance (EPR) spin labeling spectroscopy. Transmission electron microscopy showed the rubber particles to be composed of a spherical, homogeneous, core of rubber enclosed by a contiguous, electron-dense, single-track surface layer. The biochemical composition of the surface layer and its single-track TEM suggested that a monolayer biomembrane was the surface structure most compatible with the hydrophobic rubber core. The EPR spectra for a series of positional isomers of doxyl stearic acid, used to label the surface layer of the rubber particles, exhibited flexibility gradients and evidence for lipid-protein interactions for all four rubber particle types that is consistent with a biomembrane-like surface. The EPR spectra confirmed that the surface biomembrane is a monolayer. Thus, rubber particles appear similar to oil bodies in their basic architecture. The EPR spectra also provided information on protein location and degree of biomembrane penetration that correlated with the known properties of the rubber-particle-bound proteins. The monolayer biomembrane serves as an interface between the hydrophobic rubber interior and the aqueous cytosol and prevents aggregation of the particles. An unexpected observation for the probes in pure polyisoprene was evidence of an intrinsic flexibility gradient associated with the stearic acid molecule itself.

Journal Article↗

Insights into the Electronic Structure of Ceramics through Quantitative Analysis of Valence Electron Energy-loss Spectroscopy.

Valence electron energy-loss (VEEL) spectroscopy was performed on six ceramic materials in a dedicated scanning transmission electron microscope (STEM). Quantitative analysis of these data is described yielding access to the complex optical properties and the electronic structure of the materials. Comparisons are made on the basis of the interband transition strength describing transitions between occupied states in the valence band and empty states in the conduction band. This proves that the quantitative analysis of VEEL data is a competitive and complementary method to be considered when investigating the electronic structure of materials. Possibilities for improvement and extension of the analysis are discussed extensively.

Journal Article↗

Electronic signatures for long-lasting storage purposes in electronic archives.

Communication and co-operation in healthcare and welfare require a certain set of trusted third party (TTP) services describing both status and relation of communicating principals as well as their corresponding keys and attributes. Additional TTP services are needed to provide trustworthy information about dynamic issues of communication and co-operation such as time and location of processes, workflow relations, and system behaviour. Legal and ethical requirements demand securely stored patient information and well-defined access rights. Among others, electronic signatures based on asymmetric cryptography are important means for securing the integrity of a message or file as well as for accountability purposes including non-repudiation of both origin and receipt. Electronic signatures along with certified time stamps or time signatures are especially important for electronic archives in general, electronic health records (EHR) in particular, and especially for typical purposes of long-lasting storage. Apart from technical storage problems (e.g. lifetime of the storage devices, interoperability of retrieval and presentation software), this paper identifies mechanisms of e.g. re-signing and re-stamping of data items, files, messages, sets of archived items or documents, archive structures, and even whole archives.

Computer Security↗

Image acquisition with immersion objective lenses using electrons emitted with several tenths of an electron volt energies: towards high spatial resolution ESCA analysis.

This study aims to evaluate the spatial resolution achievable with photoelectrons in order to perform localised UPS or XPS analyses on various heterogeneous samples. This investigation is intentionally restricted to direct image acquisition by immersion objective lenses, involving electrons ejected with initial energies of several tenths of an electron-volt. In order to characterise the contribution of all optical elements, analytical investigations were associated to numerical simulations based on SIMION 7 software. The acquisition of high-quality images implies a simultaneous reduction in spherical and chromatic aberrations by a narrow aperture stop placed at the output pupil of the objective. With such limitations in useful emission angles, it is shown that monochromatic electron beams build images with a resolution of about 1 nm, especially for the acceleration bias mode where the focussing electrode is biased at a positive high voltage. Even energy dispersed electron beams, limited by a 4 eV band pass spectrometer, can produce images convenient for highly localised ESCA analyses (resolution 3 nm), where the objective lens is associated with an aperture stop of 30 microm in diameter without using acceleration voltages above 5000 V.

Journal Article↗

Proton to electron stoichiometry in electron transport of spinach thylakoids

According to the concept of the Q-cycle, the H+/e- ratio of the electron transport chain of thylakoids can be raised from 2 to 3 by means of the rereduction of plastoquinone across the cytochrome b6f complex. In order to investigate the H+/e- ratio we compared stationary rates of electron transport and proton translocation in spinach thylakoids both in the presence of the artificial electron acceptor ferricyanide and in the presence of the natural acceptor system ferredoxin+NADP. The results may be summarised as follows: (1) a variability of the H+/e- ratio occurs with either acceptor. H+/e- ratios of 3 (or even higher in the case of the natural acceptor system, see below) are decreased towards 2 if strong light intensity and low membrane permeability are employed. Mechanistically this could be explained by proton channels connecting the plastoquinol binding site alternatively to the lumenal or stromal side of the cytochrome b6f complex, giving rise to a proton slip reaction at high transmembrane DeltapH. In this slip reaction protons are deposited on the stromal instead of the lumenal side. In addition to the pH effect there seems to be a contribution of the redox state of the plastoquinone pool to the control of proton translocation; switching over to stromal proton deposition is favoured when the reduced state of plastoquinone becomes dominant. (2) In the presence of NADP a competition of both NADP and oxygen for the electrons supplied by photosystem I takes place, inducing a general increase of the H+/e- ratios above the values obtained with ferricyanide. The implications with respect to the adjustment of a proper ATP/NADPH ratio for CO2 reduction are discussed.

Journal Article↗

Valence electron energy loss study of Fe-doped SrTiO3 and a sigma13 boundary: electronic structure and dispersion forces.

Valence electron energy loss spectroscopy in a dedicated scanning transmission electron microscope has been used to obtain the interband transition strength of a sigma13 tilt grain boundary in SrTiO3. In a first step the electronic structure of bulk SrTiO3 has been analysed quantitatively by comparing VEELS spectra with vacuum ultraviolet spectra and with ab initio density of states calculations. The electronic structure of a near sigma13 grain boundary and the corresponding dispersion forces were then determined by spatially resolved VEELS. Also the effects of delocalization of the inelastic scattering processes were estimated and compared with results from the literature.

Journal Article↗

Backscattered electron imaging and scanning transmission electron microscopy imaging of multi-layers.

Experimental and theoretical results on image contrast of semiconductor multi-layers in scanning electron microscopy investigation are reported. Two imaging modes have been considered: backscattered electron imaging of bulk specimen and scanning transmission imaging of thinned specimens. The following main results have been reached. The image resolution of the multi-layers is, in both cases, defined by the probe size. The contrast, governed by density and atomic number differences, is affected by the size of the interaction volume in backscattered electron imaging and by the beam broadening in scanning transmission. Operating in the scanning transmission mode, the contrast of bright field images can be easily related to local variation in atomic number and density of the specimen while the dark field image contrast is strongly affected by electron beam energy, detector collection angles and specimen thickness. All these factors are able to produce contrast reversals that are difficult to explain without the support of a suitable simulation code.

Journal Article↗

Electron-electron interactions in cathode objective lenses.

The impact of electron-electron interactions on the electron-optical performance of imaging cathode objective lenses is evaluated. Three types of cathode objectives are considered: decelerating and accelerating electrostatic, and combined magnetic lenses. The beam blur is calculated for field sizes ranging from 50 microm x 50 microm to 500 microm x 500 microm and total beam currents ranging from 200 nA to 20 microA. The functional dependence of the beam blur upon electron beam current and current density is elucidated in detail.

Journal Article↗

A method of scaling the 3D electron pencil-beam dose calculation to obtain accurate monitor units for irregularly-shaped electron beams.

A method for determining monitor units (MU) for electron beams using a 3D pencil beam dose algorithm is described. A set of correction factors (OF(c)) to the pencil beam dose is generated that transforms the output into dose per MU. The OF(c)s depend on cone selection, field size, and source-to-surface distance (SSD) for a given electron energy. The dose per MU is determined by scaling the dose by the OF(c). The OF(c) value is determined using a measured set of relative output factors (OF(rel)) for various field sizes and SSD. The pencil-beam algorithm is used to compute the "raw" value (OF(p)) to each of the OF(rel) measurement points. The OF(c) is the ratio of the measured OF(rel) to the calculated OF(p). The OF(c) value for irregularly-shaped electron fields or for electron fields at extended SSD may be interpolated from the OF(c) table. The interpolation over SSD is performed linearly using the central axis SSD. The interpolation over field size is more complicated and uses the minimum area-circumscribing rectangle around the field shape. Due to the relative flatness of the OF(c), the interpolation is less error prone than the more common direct interpolation of the output factors. Computations were performed in the ADAC Pinnacle3 Planning System. Measurements were obtained using a Varian 2300c for 6 and 15 MeV. The results show that this method can predict the dose per MU within 1% to 2% for clinical fields and within 3% to 4% for extreme field shapes.

Algorithms↗

High-detective-quantum-efficiency fast-electron detector for electron energy loss spectroscopy

In order to increase the sensitivity of the parallel electron detector used in electron energy loss spectroscopy (EELS), we have developed a direct electron exposed detector, based on a photodiode array (PDA). This work investigates the performance of this detector at 100 keV incident electrons in terms of the detective quantum efficiency (DQE), the modulation transfer function (MTF) and radiation damage.

Journal Article↗

In Situ Environmental Cell-Transmission Electron Microscopy Study of Microbial Reduction of Chromium(VI) Using Electron Energy Loss Spectroscopy.

Reduction of Cr(VI) by the bacterium, Shewanella oneidensis (previously classified Shewanella putrefaciens strain MR-1), was studied by absorption spectrophotometry and in situ, environmental cell-transmission electron microscopy (EC-TEM) coupled with electron energy loss spectroscopy (EELS). Bacteria from rinsed cultures were placed directly in the environmental cell of the transmission electron microscope and examined under 100 Torr pressure. Bright field EC-TEM images show two distinct populations of S. oneidensis in incubated cultures containing Cr(VI)O2- 4: those that exhibit low image contrast and heavily precipitate-encrusted cells exhibiting high image contrast. Several EELS techniques were applied to determine the oxidation state of Cr associated with encrusted cells. The encrusted cells are shown to contain a reduced form of Cr in oxidation state +3 or lower. These results demonstrate the capability to determine the chemistry and valence state of reduction products associated with unfixed, hydrated bacteria in an environmental cell transmission electron microscope.

Journal Article↗

Applications of Ion Microscopy and In Situ Electron Microscopy to the Study of Electronic Materials and Devices.

: We discuss the application of ion microscopy and in situ electron microscopy to the study of electronic and optical materials and devices. We demonstrate how the combination of in situ transmission electron microscopy and focused ion beam microscopy provides new avenues for the study for such structures, enabling extension of these techniques to the study of dopant distributions, nanoscale stresses, three-dimensional structural and chemical reconstruction, and real-time evolution of defect microstructure. We also discuss in situ applications of thermal, mechanical, electrical, and optical stresses during transmission electron microscopy imaging.

Journal Article↗

Using resonance Raman spectroscopy to examine vibrational barriers to electron transfer and electronic delocalization.

A time-dependent approach to the interpretation of resonance Raman scattering intensities has been used to obtain quantitative vibrational mode displacement information from scattering intensities associated with charge-transfer excitation. The displacements and associated frequencies are the key parameters needed to understand Franck-Condon effects in electron-transfer kinetics, and to delineate in a mode-specific way the composition of vibrational reorganization energies. Application of the approach to a number of types of electron-transfer reactions is described, including symmetrical and unsymmetrical intervalence electron transfers in inorganic and organic redox systems, metal-to-ligand charge-transfer reactions, and interfacial electron-transfer reactions. Also described is how the approach can be used to elucidate mechanisms for valence delocalization in strongly interacting redox systems.

Journal Article↗

Investigation of the electronic and structural properties of potassium hexaboride, KB6, by transport, magnetic susceptibility, EPR, and NMR measurements, temperature-dependent crystal structure determination, and electronic band structure calculations.

The electronic and structural properties of potassium hexaboride, KB(6), were examined by transport, magnetic susceptibility, EPR, and NMR measurements, temperature-dependent crystal structure determination, and electronic band structure calculations. The valence bands of KB(6) are partially empty, but the electrical resistivity of KB(6) reveals that it is not a normal metal. The magnetic susceptibility as well as EPR and NMR measurements show the presence of localized electrons in KB(6). The EPR spectra of KB(6) have two peaks, a broad ( approximately 320 G) and a narrow (less than approximately 27 G) line width, and the temperature-dependence of the magnetic susceptibility of KB(6) exhibits a strong hysteresis below 70 K. The temperature-dependent crystal structure determination of KB(6) shows the occurrence of an unusual variation in the unit cell parameter hence supporting that the hysteresis of the magnetic susceptibility is a bulk phenomenon. The line width DeltaH(pp) of the broad EPR signal is independent of temperature and EPR frequency. This finding indicates that the line broadening results from the dipole-dipole interaction, and the spins responsible for the broad EPR peak has the average distance of approximately 1.0 nm. To explain these apparently puzzling properties, we examined a probable mechanism of electron localization in KB(6) and its implications.

Journal Article↗

The electronic ground state of [V(urea)6]3+ probed by NIR luminescence, electronic Raman, and high-field EPR spectroscopies.

The electronic structure of a trigonally distorted vanadium(III) complex, [V(urea)6](ClO4)3, and its deuterated analogue, [V(urea-d4)6](ClO4)3 has been investigated with Raman, luminescence, and high-frequency high-field electron paramagnetic resonance spectroscopies and with magnetic measurements. A broad electronic Raman transition is observed at around 1400 cm(-1) and attributed to a transition to the (3)E (D3) component of the (3)T1g (O(h)) ground state. The same splitting is seen in the near-infrared luminescence spectrum in the form of a similarly broad peak at 8450 cm(-1), 1400 cm(-1) lower in energy than the (1)E --> (3)A2 spin-flip transition. Powder high-frequency and high-field electron paramagnetic resonance spectra, magnetic susceptibilities, and magnetization studies give a precise measurement of the zero-field splitting and of the g values in this complex (D = 6.00(2) cm(-1), E = 0.573(6) cm(-1), g(x) = 1.848(2), g(y) = 1.832(4), and g(z) = 1.946(7)). A set of angular overlap model parameters is proposed that reproduces all spectroscopic observations, and an analysis of the influence of the bonding of urea on the trigonal distortion of the complex is given.

Journal Article↗