Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dose Reconstruction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29Linked to original sources

Comparison of three methods of numerical procedures for ESR dosimetry of human tooth enamel.

Three numerical methods were employed to examine how gamma ray doses ranging from 100 mGy to 1Gy could be reconstructed using five human molar teeth. For samples above 28 0mGy, the obtained doses are consistent with each other within the errors but slightly larger than actually given doses. Background doses range from 20 to 170 mGy depending on the methods and samples. Further precise studies would be needed to characterize each method, but it would be recommended to apply several methods to check the reliability of the obtained doses.

Algorithms↗

Studies on epidermis reconstructed with and without melanocytes: melanocytes prevent sunburn cell formation but not appearance of DNA damaged cells in fair-skinned caucasians.

To assess the photoprotective role of melanocytes in the epidermis, we studied the effects of ultraviolet B on an epidermis reconstructed with and without melanocytes. To address more specifically the role of melanin in fair-skinned individuals, experiments were done with cells obtained from human skin of low phototypes (II-III). To study the effect of constitutive melanin and possibly that of newly synthesized melanin precursors, a single dose of ultraviolet B (0.10 or 0.15 J per cm2, corresponding to a 4-5 minimal erythema dose in vivo) was administered to reconstructs and the effects were monitored over the first 24 h. When reconstructs with and without melanocytes were compared, no difference was found for DNA damage/repair assessed with antibodies to cyclobutane pyrimidine dimers and 6-4 photoproducts. More necrotic/apoptotic cells, however, were noted 24 h following ultraviolet B irradiation in reconstructs lacking melanocytes. Twenty-four hours following ultraviolet B irradiation the number of necrotic/apoptotic cells and the number of cyclobutane pyrimidine dimer positive cells was coarsely concentration-dependent. The number of cyclobutane pyrimidine dimer positive cells, however, was independent of the type of reconstruct used (with/without melanocytes). In conclusion, low phototype melanocytes seem to protect epidermal basal cells against ultraviolet B-induced apoptosis/necrosis and may preserve the overall integrity of the epidermis after ultraviolet B irradiation. On the contrary, such melanocytes do not seem to have a protective role against DNA damage and may not prevent cancer.

Adult↗

Evaluation of image quality and dose in renal colic: comparison of different spiral-CT protocols.

The aim of this study was to test different technical spiral-CT parameters to obtain optimal image quality with reduced X-ray dose. Images were acquired with a spiral-CT system Philips Tomoscan AVE1, using 250 mA, 120 kV, and 1-s rotational time. Three protocols were tested: protocol A with 5-mm thickness, pitch 1.6, slice reconstruction every 2.5 mm; protocol B with 3-mm thickness, pitch 1.6, slice reconstruction every 1.5 mm; and protocol C with 3-mm thickness, pitch 2, slice reconstruction every 1.5 mm. Two phantoms were employed to evaluate the image quality. Axial images were acquired, then sagittal and coronal images were reconstructed. Finally, the absorbed X-ray dose for each protocol was measured. Regarding image quality, 5-mm-thick images (protocol A) showed greater spatial resolution and lower noise compared with 3-mm-thick images (protocols B and C) on the axial plane; 3-mm reconstructed sagittal and coronal images (protocols B and C) showed an improved image quality compared with 5-mm reformatted images (protocol A). Concerning X-ray dose, the mean dose was: protocol A 19.6 +/- 0.8 mGy; protocol B 14.4 +/- 0.6 mGy; protocol C 12.5 +/- 1.0 mGy. Our study supports the use of thin slices (3 mm) combined with pitch of 1.6 or 2 in renal colic for X-ray dose reduction to the patient and good image quality.

Clinical Protocols↗

Estimate of absorbed dose based on two-dimensional autoradiographic information in internal radionuclide therapy.

In radiation therapies using radionuclides emitting short-range particles, such as radioimmunotherapy or boron neutron capture therapy, the biological effects are strongly affected by the heterogeneity of the absorbed dose distribution delivered to tumor cells. The three-dimensional (3D) information of the source distribution at the cellular level is required to accurately determine the absorbed dose distribution to the individual tumor cells. Two-dimensional distribution of cell and nuclide with a resolution of 1 microm can be obtained from individual tissue sections by microautoradiography. To obtain such information in 3D, an ideal approach would be to align the serial tissue sections from a block and analyze all of them. This is straightforward in theory, but extremely difficult in practice. Furthermore, every section in the block has to be processed and analyzed, and the usage of the data from this laborious work is very inefficient. An approach presented here is to estimate the absorbed dose based on individual sections without 3D reconstruction. It is realistically workable since it avoids the most difficult task of alignment for the serial tissue sections. In addition, the absorbed dose can be estimated based on a limited number of noncontiguous sections. The validity of this approach has been tested by a Monte Carlo simulation for two representative radionuclide configurations: (a) a uniform distribution of sources and (b) a cell membrane bound source distribution. With only a limited number of sampling sections, the uncertainties in the dose estimation were estimated to approximately 15% for short-range particles.

Autoradiography↗

Interface radiation dosimetry in mandibular reconstruction.

When a beam of radiation crosses the interface between two substances, secondary electrons are generated. This results in enhancement of the absorbed dose of radiation roughly proportional to the difference in atomic numbers. Interfaces are created in reconstruction of the mandible with implantable trays containing hematopoietic bone marrow and cancellous bone chips. Radiation was measured in tissue-equivalent material surrounding mandibular tray implants of titanium, vitallium, stainless steel, and Dacron/polyetherurethane. The absorbed dose was enhanced by 29% to 36% adjacent to the metallic trays; 1% dose enhancement was noted adjacent to the Dacron/polyetherurethane tray. We conclude that, when radiation therapy is necessary following mandibular reconstruction, homogeneity of dose is maintained and local soft-tissue reactions to excessive irradiation may be avoided by using a nonmetallic tray.

Biocompatible Materials↗

The structure of the helically perturbed flagellar filament of Pseudomonas rhodos: implications for the absence of the outer domain in other complex flagellins and for the flexibility of the radial spokes.

Bacterial flagella, the organelles of motility, are commonly divided into two classes: 'plain' and 'complex'. The complex filaments are pairwise, helically perturbed forms of the plain filaments and have been reported to occur only in Rhizobium and Pseudomonas. Previously, we reconstructed and analysed the structure of the complex filaments of Rhizobium lupini H13-3 and determined their unique symmetry and origin of the perturbations (Trachtenberg et al., 1986, J Mol Biol 190: 569-576; 1987, 195: 603-620; 1998, 276: 759-773; Cohen-Krausz and Trachtenberg, 1998, J Struct Biol 122: 267-282). Here, we analyse the structure of the flagellar filament of the other known complex filament, that of Pseudomonas rhodos, as reconstructed from electron microscope images. Compared with the filament of R. lupini, the filament of P. rhodos is more flexible, as implied from high-intensity darkfield light microscopy and, although constructed from flagellins of higher molecular weights (59 versus 41 kDa), has similar symmetry. Using cryonegative stained specimens and low-dose, field emission electron microscopy, we reconstructed and averaged 158 filaments each containing 170 statistically significant layer lines. The three-dimensional density maps of P. rhodos clearly suggest, when compared with those of R. lupini and the right-handed Salmonella typhimurium SJW1655, that R. lupini is missing the outer flagellin domain (D3), that the interior of the complex filament is rather similar to that of the plain filament and that the radial spokes (connecting domains D0 and D1), present in individual density maps, average out because of their variability and implied flexibility. Extending the three-start grooves and ridges on the propeller's surface, in the form of an Archimedean screw, may further improve the motility of the cell in viscous environments.

Flagella↗

CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose-volume parameters.

PURPOSE: To perform an intracavitary radiotherapy (ICR) plan comparison between the conventional point A plan (conventional plan) and computed tomography (CT)-guided clinical target volume-based plan (CTV plan) by analysis of the quantitative dose-volume parameters and irradiated volumes of organs at risk in patients with cervical cancer. METHODS AND MATERIALS: Thirty plans for 192Ir high-dose-rate ICR after 30-40-Gy external beam radiotherapy were investigated. CT images were acquired at the first ICR session with artifact-free applicators in place. The gross tumor volume, clinical target volume (CTV), point A, and International Commission on Radiation Units and Measurements Report 38 rectal and bladder points were defined on reconstructed CT images. A fractional 100% dose was prescribed to point A in the conventional plan and to the outermost point to cover all CTVs in the CTV plan. The reference volume receiving 100% of the prescribed dose (V(ref)), and the dose-volume parameters of the coverage index, conformal index, and external volume index were calculated from the dose-volume histogram. The bladder, rectal point doses, and percentage of volumes receiving 50%, 80%, and 100% of the prescribed dose were also analyzed. RESULTS: Conventional plans were performed, and patients were categorized on the basis of whether the 100% isodose line of point A prescription dose fully encompassed the CTV (Group 1, n = 20) or not (Group 2, n = 10). The mean gross tumor volume (11.6 cm3) and CTV (24.9 cm3) of Group 1 were smaller than the corresponding values (23.7 and 44.7 cm3, respectively) for Group 2 (p = 0.003). The mean V(ref) for all patients was 129.6 cm(3) for the conventional plan and 97.0 cm3 for the CTV plan (p = 0.003). The mean V(ref) in Group 1 decreased markedly with the CTV plan (p < 0.001). For the conventional and CTV plans in all patients, the mean coverage index, conformal index, and external volume index were 0.98 and 1.0, 0.23 and 0.34, and 3.86 and 2.15, respectively. Statistical analysis showed that the conformal index and external volume index improved significantly with the CTV plan, and this improvement was more marked in Group 1. The mean values of the bladder and rectal point doses and volume fractions receiving 50%, 80%, and 100% of the reference dose did not differ between plans for all patients. The reduction in the mean rectal and bladder point doses and irradiated volumes for the CTV plan was statistically significant in Group 1. CONCLUSION: Computed tomography-guided CTV planning of ICR is superior to conventional point A planning in terms of conformity of target coverage and avoidance of overdosed normal tissue volume. To ascertain the potential benefit of treatment outcome, ICR with image-guided three-dimensional plans will be pursued and correlated with the dose-volume parameters.

Antineoplastic Agents↗

An error-reduction-based algorithm for cone-beam computed tomography.

Image reconstruction from cone-beam projections collected along a single circular source trajectory is commonly done using the Feldkamp algorithm, which performs well only with a small cone angle. In this report, we propose an error-reduction-based algorithm to increase the cone angle by several folds to achieve satisfactory image quality at the same radiation dose. In our scheme, we first reconstruct the object using the Feldkamp algorithm. Then, we synthesize cone-beam projection data from the reconstructed volume in the same geometry, and reconstruct the volume again from the synthesized projections. Finally, these two reconstruction results are combined to reduce the reconstruction error and produce a superior image volume. The merit of this algorithm is demonstrated in numerical simulation.

Algorithms↗

Methods of image reconstruction from projections applied to conformation radiotherapy.

The problem of optimizing the dose distribution for conformation radiotherapy with intensity modulated external beams is similar to the problem of reconstructing a 3D image from its 2D projections. In this paper we analyse the relationship between these problems. We show that the main image reconstruction methods, namely filtered backprojection and iterative reconstruction, can be directly applied to conformation therapy. We examine the features of each of these methods with regard to this new application and we present first theoretical results.

Humans↗

Patient dose from 3D rotational neurovascular studies.

The use of image-guided interventional radiological techniques is increasing in prevalence and complexity. Imaging system developments have helped improve the information available to interventionalists to plan and guide procedures. Information on doses to patients resulting from alternative imaging techniques or protocols is useful for both the process of justifying particular procedures and in optimizing the resultant exposures. Such information is not always available, especially for new or developing imaging techniques. We have undertaken a study of doses to patients associated with two alternative imaging methods for pre-intervention assessment of intracranial aneurysms. In the first technique the aneurysm is assessed from a series of digital subtraction angiography (DSA) runs taken at different imaging projections. The second technique involved acquiring images from one single image run while the imaging system rotated 180 degrees around the patient's head. In this technique, the aneurysm was then evaluated from a 3D reconstruction of the projection images. Effective doses were calculated using a computer model to simulate the exposure geometry and parameters. The mean dose from the DSA protocol used at our centre was 3.4 mSv and from the 3D rotational angiography (RA) technique was 0.20 mSv.

Angiography, Digital Subtraction↗

The role of the greater omentum in intrathoracic transposition.

This review shows that the application of pedicled omental flaps or gastro-omental grafts with microvascular connection to the recipient is a reliable and safe means of reconstructing and protecting esophageal, pharyngeal and soft tissue defects and in problems related to sepsis. It has shown its usefulness in those patients who had high-dose radiation with tissue damage, in whom reconstruction otherwise would have required multiple stages or multiple flaps, or in whom other reconstructive options have failed. With the increasing use of radio- and chemotherapy as the treatment for various types of cancer, surgeons and radiotherapists are required to cope with the complications of this therapy. They should become familiar with the usefulness of the omentum in difficult problems. Despite the fact that omental transposition is usually undertaken in risky situations and in patients with poor health conditions, this technique is associated with a remarkably low morbidity and mortality.

Anastomosis, Surgical↗

Precision in quantitative CT: impact of x-ray dose and matrix size.

A study was performed to determine whether recommended technique factors for postprocessing dual-energy (DE) quantitative computed tomography are optimum in terms of precision and x-ray dose. In particular, possible dose reduction as a result of an upgrade of the CT scanner to more efficient detectors was explored. Series of images of an anthropomorphic phantom containing a human vertebra, a tissue-simulating lumbar simulator with various marrow inserts, and a polyethylene cylinder were generated. Recommended DE x-ray technique factors as well as factors resulting in about two times, one-half, and one-fourth the x-ray dose were employed. The effects of reconstruction with different matrix sizes was studied. Standard deviations of the CT numbers within regions of interest in individual images (noise) and standard deviations of mean CT numbers, single-energy (SE), and DE measurements for series of images (reproducibilities) were computed. It was found that the low-energy component of the DE technique was optimum, but the high-energy component could be reduced by a factor of 2 with negligible loss in precision. This translates into a dose reduction of 36% relative to the recommended DE technique. Vertebral inhomogeneities were responsible for more than 65% of the standard deviations in individual images of the vertebra even at the lowest doses. For all of the techniques, the noise in images of all objects decreased as the x-ray dose increased and as the matrix size decreased. Reproducibility of mean values, however, did not necessarily improve, and aberrant results such as improvement in reproducibility with a reduction in dose were sometimes observed. It is hypothesized that this may be due to variations in the actual kVp for each image in a series.

Absorptiometry, Photon↗

Preliminary uncertainty analysis for the doses estimated using the Techa River dosimetry system--2000.

The Mayak Production Association (MPA) was the first facility in the former Soviet Union for the production of plutonium. As a result of failures in the technological processes in the late 1940's and early 1950's, members of the public were exposed via discharge of about 10(17) Bq of liquid wastes into the Techa River (1949-1956). Residents of many villages downstream on the Techa River were exposed via a variety of pathways; the more significant included drinking of water from the river and external gamma exposure due to proximity to sediments and shoreline. The specific aim of this project is to enhance the reconstruction of external and internal radiation doses for individuals in the Extended Techa River Cohort. The purpose of this paper is to present the approaches being used to evaluate the uncertainty in the calculated individual doses and to provide example and representative results of the uncertainty analyses. The magnitude of the uncertainties varies depending on location and time of individual exposure, but the results from reference-individual calculations indicate that for external doses, the range of uncertainty is about a factor of four to five. For internal doses, the range of uncertainty depends on village of residence, which is actually a surrogate for source of drinking water. For villages with single sources of drinking water (river or well), the ratio of the 97.5th percentile-to 2.5th percentile estimates can be a factor of 20 to 30. For villages with mixed sources of drinking water (river and well), the ratio of the range can be over two orders of magnitude.

Databases, Factual↗

Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch.

A new 3D reconstruction scheme, weighted filtered backprojection (WFBP) for multirow spiral CT based on an extension of the two-dimensional SMPR algorithm is described and results are presented. In contrast to other 3D algorithms available, the algorithm makes use of all available data for all pitch values. The algorithm is a FBP algorithm: linear convolution of the parallel data along the row direction followed by a 3D backprojection. Data usage for arbitrary pitch values is maintained through a weighting scheme which takes into account redundant data. If proper row weighting is applied, the image quality is superior to the image quality of the SMPR algorithm.

Algorithms↗

Matched view weighting in tilted-plane-based reconstruction algorithms to suppress helical artifacts and optimize noise characteristics.

In multi-slice helical CT, the single-tilted-plane-based reconstruction algorithm has been proposed to combat helical and cone beam artifacts by tilting a reconstruction plane to fit a helical source trajectory optimally. Furthermore, to improve the noise characteristics or dose efficiency of the single-tilted-plane-based reconstruction algorithm, the multi-tilted-plane-based reconstruction algorithm has been proposed, in which the reconstruction plane deviates from the pose globally optimized due to an extra rotation along the 3rd axis. As a result, the capability of suppressing helical and cone beam artifacts in the multi-tilted-plane-based reconstruction algorithm is compromised. A matched view weighting approach is proposed here to optimize the capability of suppressing helical and cone beam artifacts and noise characteristics. A helical body phantom is employed to quantitatively evaluate the imaging performance of the matched view weighting approach, showing that the matched view weighting improves both the helical artifact suppression and noise characteristics or dose efficiency significantly in comparison to the case in which nonmatched view weighting is applied. The matched view weighting approach is of practical importance in the development of multi-slice helical CT, because it maintains the computational structure of fan beam filtered back-projection and demands no extra computational resources.

Algorithms↗

Operator-free, film-based 3D seed reconstruction in brachytherapy.

In brachytherapy implants, the accuracy of dose calculation depends on the ability to localize radioactive sources correctly. If performed manually using planar images, this is a time-consuming and often error-prone process-primarily because each seed must be identified on (at least) two films. In principle, three films should allow automatic seed identification and position reconstruction; however, practical implementation of the numerous algorithms proposed so far appears to have only limited reliability. The motivation behind this work is to create a fast and reliable system for real-time implant evaluation using digital planar images obtained from radiotherapy simulators, or mobile x-ray/fluoroscopy systems. We have developed algorithms and code for 3D seed coordinate reconstruction. The input consists of projections of seed positions in each of three isocentric images taken at arbitrary angles. The method proposed here consists of a set of heuristic rules (in a sense, a learning algorithm) that attempts to minimize seed misclassifications. In the clinic, this means that the system must be impervious to errors resulting from patient motion as well as from finite tolerances accepted in equipment settings. The software program was tested with simulated data, a pelvic phantom and patient data. One hundred and twenty permanent prostate implants were examined (105 125I and 15 103Pd) with the number of seeds ranging from 35 to 138 (average 79). The mean distance between actual and reconstructed seed positions is in the range 0.03-0.11 cm. On a Pentium III computer at 600 MHz the reconstruction process takes 10-30 s. The total number of seeds is independently validated. The process is robust and able to account for errors introduced in the clinic.

Algorithms↗

Immediate breast reconstruction-impact on radiation management.

Breast reconstruction is an option for women undergoing modified radical mastectomy due to a diagnosis of breast cancer. In certain patients, breast reconstruction is performed by insertion of a temporary tissue expander prior to the placement of permanent breast implants. Some of these patients, following mastectomy, may require chest wall irradiation to prevent loco regional relapse. The compatibility of radiation and tissue expanders placed in the chest wall is of major concern to the radiation oncologist. Clinically undetectable changes can occur in the tissue expander during the course of radiation therapy. This can lead to radiation treatment set-up changes, variation in tissue expansion resulting in unwanted cosmesis, and deviation from the prescribed radiation dose leading to over and/or under dosing of tumor burden. At Howard University hospital, a CT scan was utilized to evaluate the status of the temporary tissue expander during radiation treatment to enable us to prevent radiation treatment related complications resulting from dosimetric discrepancies. CT images of the tissue expander were obtained through the course of treatment. To avoid a 'geographic miss' the amount of fluid injected into the tissue expander was kept constant following patient's satisfaction with the size of the breast mound. The CT scans allowed better visualization of the prosthesis and its relation to the surrounding tumor bed. This technique ensured that anatomical changes occurring during radiation treatment, if any, were minimized. Repeated dosimetry evaluations showed no changes to the prescribed dose distribution. A CT of the reconstructed breast provides an important quality control. Further studies with greater number of patients are required for confirming this impact on radiation treatment.

Breast Implants↗

[Examination of attenuation correction using low-dose computed tomography].

Attenuation correction is necessary for the reconstruction of SPECT images. One report has mentioned that attenuation correction by X-ray computed tomography (CT) is effective for a non-uniform attenuation body. We examined the effect of attenuation correction on SPECT images by changing the scanning conditions of CT, and evaluated the possibility of attenuation correction by low-dose CT. The phantom was scanned under several X-ray tube conditions varying from 80 kV to 135 kV and from 7.5 mAs to 200 mAs. We obtained equations of attenuation correction based on the Hounsfield Unit (HU) units of each pixel and compared the effects of attenuation correction. The results showed that the equation for attenuation correction under each condition did not vary significantly, and the effects of attenuation correction by the equations did not vary significantly between CT of low dose and that of clinical dose. This result suggest that the attenuation correction obtained by low-dose CT was equal to that obtained by the clinical dose. In conclusion, it seemed that the equation and map of attenuation correction matched with each radionuclide yielded more adequate attenuation correction than conventional methods.

Image Processing, Computer-Assisted↗