Factors influencing long-term in vivo reproducibility of QCT overtebral densitometry).

OBJECTIVE: We investigated the long-term in vivo reproducibility of quantitative CT (QCT) examinations that were conducted in conformity with a standard and well established methodology. MATERIALS AND METHODS: The long-term reproducibility in vivo of QCT vertebral densitometry was studied in 12 normal postmenopausal women (mean age 51 years), who underwent four to five examinations over the same 2 year period. RESULTS: One group of six patients demonstrated good reproducibility with a coefficient of variation (CV) of bone mineral density (BMD) of < 2.4% and were considered "good cases." The other group of six patients showed poor reproducibility with a CV of BMD of > 3.2% and were considered "problem cases." A statistical study of the technical parameters of the QCT examination was performed to determine and correct for the factors that are correlated with reproducibility errors. Analyzing uncalibrated variations in Hounsfield numbers, we found that the surrounding soft tissues such as muscle, aorta, liver, and fat were correlated in both the good and the problem cases. However, only in the good cases did we find that the Hounsfield numbers of the vertebral bodies correlated strongly with the soft tissues and with parameters characteristic of the calibration regression line. CONCLUSION: Essentially, the calibration procedure appeared to fail in some examinations of the problem cases, causing poor long-term reproducibility. This calibration failure may be related to positioning of the subject in the gantry and to variations in electrical parameters of the X-ray tube. A CV > 1% between the four slopes of calibration for the individual vertebrae measured at the same visit may indicate calibration problems and may suggest the need for repeat scanning.

Aortography↗

Comparison of instruments for dual-energy X-ray bone mineral densitometry.

While bone mineral densitometry has become a common laboratory test, it is important to pay attention to the compatibility of the results from different instruments. In this study results from three commercially available bone densitometers are compared using both patient and phantom studies. Overall correlation between instruments was good but there were systematic discrepancies in the results. The three instruments provided bone mineral density (BMD) values that differed by as much as 13.5% due to differences as large as 6% in bone mineral content and as large as 7% in bone area. Thus, the BMD values obtained from different manufacturers' instruments are not directly comparable.

Absorptiometry, Photon↗

Histochemical technique: densitometry of nanogram quantities of proteins separated in one-dimensional microslab gels.

We describe methods for densitometry of electrophoretically separated proteins in 25-millimeter microslab gels. The methods are sufficiently sensitive to use with several individually excised plant cells, for which we describe an extraction procedure. In brief, submicrogram samples are excised from freeze-dried plant tissue. Extraction takes place under oil in microliter droplets of detergent. Proteins are separated by one-dimensional microelectrophoresis (HM Poehling, V Neuhoff 1980 Electrophoresis 1: 90-102) and then stained by a sensitive Coomassie procedure (V Neuhoff, R Stamm, E Hansjorg 1985 Electrophoresis 6: 427-448). The resulting profile is scanned by a computerized densitometer based on the Leitz Diavert MPV Microphotometer. Evaluations and typical data demonstrate the high performance of this system.

Journal Article↗

Compton scatter densitometry with polychromatic sources.

The use of x-ray tubes as radiation sources for Compton scatter densitometry (CSD) is evaluated theoretically. Bias correction factors (bcf's) which correct for differential attenuation due to Compton shift and polychromaticity, and differential scattering cross section due to polychromaticity, are defined to facilitate comparison of monochromatic and x-ray tube CSD devices. Computer modeling indicates that a 100-kVp x-ray tube spectrum hardened with 0.64 mm of Pb filtration yields bcf's 0.008 to 0.34% higher than a 70-keV monochromatic source for various samples of nylon, and human muscle and bone. This difference is insignificant because multiple scatter errors are typically 1000% higher than errors corrected by bcf's. The high equivalent activities of x-ray tubes (10 to 80 TBq) and their small focal spots (1.0 to 2.0 mm) allow the long-standing CSD problems of marginal statistical precision, long counting times, and low spatial resolution to be overcome.

Absorptiometry, Photon↗

A Monte Carlo study of multiple scatter effects in Compton scatter densitometry.

The contribution of multiple scatter to the measured signal in x- and gamma-ray Compton scatter densitometry has been investigated theoretically by the use of Monte Carlo techniques to follow individual photon life histories. A three component phantom was employed in the computer model to simulate the patient at three examination sites; the radius/ulna, the femoral neck, and the lumbar spine. Monoenergetic radiation beams of 60- and 100-keV photons and polyenergetic x-ray spectra of 100 and 140 kVp were used. Scattered events were detected over 360 degrees and classified according to their origin and frequency of scatter. The single scatter in bone to multiple scatter ratio was studied as an indication of the signal-to-noise ratio and this was found to vary with phantom size but was independent of photon energy. Correction factors to be used in a clinical densitometer to account for the inclusion of multiple scatter events were computed. These were found to be 0.65-0.58 at the optimum scattering angles for the phantoms considered.

Absorptiometry, Photon↗

The nonlinear partial volume effect and computed tomography densitometry of foam and lung.

A quantitative study was performed to assess the magnitude of the nonlinear partial volume effect (NLPVE) in computed tomography (CT) densitometry of polyethene foam and lung. This effect arises in materials having density variations on the scale of the sampling area of an individual CT-detector element. It causes a systematic underestimation of the density determined with CT. Foam samples and a resected lung of a goat were imaged with high resolution (20 lp/mm) using a mammography system, and the observed optical density variation in the images was converted into a distribution of pathlengths that x rays penetrate within the solid component of the cellular material. The obtained pathlength distribution was used to calculate the transmission, as seen by a single detector in computed tomography. Comparison with the transmission through homogeneous material of the same thickness gave an estimate of the NLPVE. For the foams studied, the CT-determined density was found to be too low by approximately 0.3%-0.5% due to this effect. Although these density errors are small, in calibrations of a CT scanner they may be of significance. For lung the underestimation of the density was less than 0.1%. These experimentally derived, NLPVE related CT-density errors are 32%-84% of those calculated from a simple model of a cellular solid.

Humans↗

Dual-energy bone densitometry using a single 100 ns x-ray pulse.

A pulsed, portable hard x-ray source has been developed for medical imaging and flash x-ray absorptiometry. The source is powered by a Marx generator that drives a field emission x-ray tube which produces a 30-300 keV x-ray pulse of 100 ns duration. The x-ray fluence has dual-energy properties. The x-ray energy is relatively high early in the pulse and lower later in the pulse. The feasibility of using a single x-ray pulse for precision bone densitometry was analyzed. A computer simulation model was developed for the x-ray source, the filtration that enhances the dual-energy distribution, the absorption of the energy distribution by bone mineral and soft tissue, and the dual-energy detection system. It is feasible to determine the bone mineral density (BMD) of axial sites such as the lumbar spine and proximal femur with 2% precision over an area that is 15-20 mm in size, depending on the bone mineral and soft tissue thicknesses. An algorithm for determining the absolute BMD, to an accuracy of 2%, using a Plexiglas/TiO2 calibration phantom is discussed. At a distance of 50 cm from the source, the patient exposure is 3.7 mR. The average absorbed bone and tissue doses are 0.6 and 4.3 mrem, respectively. Factors that facilitate diagnostic measurements in clinical settings are the short patient observation time and the portability of the x-ray source.

Absorptiometry, Photon↗

Bone densitometry in children assessed by dual x ray absorptiometry: uses and pitfalls.

The importance of bone growth and mineralisation during childhood for bone health in adult life is increasingly accepted, with both nutritional factors(1) and exercise(2) being recognised as influential for normal skeletal development. The appreciation that infancy and childhood are important periods of life for bone development has led to a need for suitable methods for monitoring bone health, both for research purposes and for clinical monitoring of individuals, and hence to an increasing use of bone densitometry in children. This review discusses the role and potential pitfalls of this technique.

Absorptiometry, Photon↗

Usefulness of bone densitometry in postmenopausal women with clinically diagnosed vertebral fractures.

OBJECTIVE: To analyse whether bone mineral density (BMD) assessment is required in postmenopausal women presenting with low trauma vertebral fracture. METHODS: Women with vertebral fracture diagnosed over a 10 year period were recruited from our database. The following were excluded: (a) patients with high energy trauma; (b) patients with malignancies; (c) patients with a metabolic bone disease other than osteoporosis. All postmenopausal women were included in whom BMD had been evaluated at both the lumbar spine and femoral neck by dual energy x ray absorptiometry during the six months after the diagnosis. Patients with a potential cause of osteoporosis other than age and menopause were not considered. A total of 215 patients were identified. RESULTS: The mean (SD) age of the patients was 65.9 (6.9) years. BMD at the lumbar spine was 0.725 (0.128) g/cm(2) and the T score was -2.94 (1.22); BMD at the femoral neck was 0.598 (0.095) g/cm(2) and the T score was -2.22 (0.89). The BMD of the patients was significantly lower than that of the general population at both the lumbar spine and femoral neck. When the lowest value of the two analysed zones was considered, six patients (3%) showed a normal BMD, 51 (23.5%) osteopenia, and 158 (73.5%) osteoporosis. The prevalence of osteoporosis at the femoral neck increased with age; it was 25% in patients under 60, 35% in patients aged 60-70, and 60% in patients over 70. CONCLUSION: These results indicate that bone densitometry is not required in postmenopausal women with clinically diagnosed vertebral fractures if it is performed only to confirm the existence of a low BMD.

Absorptiometry, Photon↗

A study of bone densitometry in patients with complex regional pain syndrome after stroke.

INTRODUCTION: This study was undertaken to evaluate the bone mineral density (BMD) in patients with complex regional pain syndrome type-I (CRPS-I) after stroke, and to correlate it with various clinical and neurophysiological parameters. PATIENTS AND METHODS: Twenty patients with CRPS-I after stroke were included and a detailed neurological evaluation was carried out. The severity of CRPS-I was graded on the basis of shoulder hand syndrome score. All the patients underwent bone mineral densitometry of paralysed and non-paralysed forearm by dual energy x ray absorptiometry. The BMD of paralysed forearm was also compared with that of age matched healthy controls. Neurophysiological tests included sympathetic skin response in both upper and lower limbs and median somatosensory evoked potentials. RESULTS: The mean age of patients was 57.2 (45-75) years and eight were females. Eight patients had severe weakness and 12 had moderate weakness of grade 2 on the hemiplegic side. There was significant reduction in BMD in the patients compared with controls (p<0.01). The bone density reduction correlated well with duration of illness (r = -0.673, p<0.01), shoulder hand syndrome score (r = -0.804, p<0.01), and Canadian neurological scale score (r = -0.738 p<0.01). Sympathetic skin response was not recordable bilaterally in all patients. Median somatosensory evoked potentials were not recordable in seven out of 20 patients who also had higher grade of CRPS-I. CONCLUSION: Our results show significant reduction of BMD in patients with CRPS-I after stroke. The reduction in BMD correlates with the severity of shoulder hand syndrome score, degree of weakness, duration of hemiplegia, and the severity of stroke.

Absorptiometry, Photon↗

Chronic obstructive pulmonary disease: evaluation with spirometrically controlled CT lung densitometry.

PURPOSE: To compare the computed tomographic (CT) lung densitometry results in patients with chronic obstructive pulmonary disease (COPD) and in control subjects (healthy persons). MATERIALS AND METHODS: Spirometrically gated CT sections at 5 cm above and 5 cm below the carina at 90% and 10% vital capacity (VC) were imaged in patients and controls. Various densitometric parameters were derived from the CT data, and results were compared between the two levels of inspiration. RESULTS: Densitometric results in patients with emphysema were substantially different from those in patients with chronic bronchitis and in controls at 90% and 10% VC. Differences in patients with chronic bronchitis and in controls were not significant at 90% VC but were significant at 10% VC (P < .001). The mean changes in densitometric parameters between 90% and 10% VC were substantially greater in controls than in patients with COPD. CONCLUSION: It may be possible to classify lung disease with only two CT sections obtained at the same anatomic level, one at 90% and one at 10% VC, irrespective of the densitometric parameter used.

Absorptiometry, Photon↗

Cupid's bow contour of the vertebral body: evaluation of pathogenesis with bone densitometry and imaging-histopathologic correlation.

PURPOSE: To investigate the Cupid's bow contour by means of bone densitometry and imaging-histopathologic correlation. MATERIALS AND METHODS: Radiographs and histologic slices were obtained in 64 cadaveric thoracolumbar spines to assess the morphology, distribution, and histopathologic features of the Cupid's bow contour. Dual-energy x-ray absorptiometry and radiography were performed in the lumbar spine in 406 healthy subjects. Bone density and body height and weight were then related to the presence of the Cupid's bow contour. The Cupid's bow contour was compared with the fish vertebra of osteoporosis and Schmorl node. RESULTS: No clinically important relationship was found between lumbar bone density, body height and weight, and prevalence of the Cupid's bow contour. Histologic examination showed thickened bone in the Cupid's bow end plate with annular fibers inserting into this region. In cadavers, the Cupid's bow contour occurred at multiple lumbar and thoracic levels, with the highest frequency in the lower lumbar spine. Lateral radiographs enabled better detection of the contour change. CONCLUSION: The Cupid's bow deformity is a developmental phenomenon that is unrelated to osteopenia or mechanical stress on the spine.

Absorptiometry, Photon↗

Ventilation abnormalities in obstructive airways disorder: detection with pulmonary dynamic densitometry by means of spiral CT versus dynamic Xe-133 SPECT.

PURPOSE: To evaluate pulmonary dynamic densitometry (PDD) by means of spiral computed tomography (CT) for detection of ventilation abnormalities in obstructive airways disorders compared with dynamic xenon-133 single photon emission CT. MATERIALS AND METHODS: Eight-second spiral CT was performed during two to three respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data sets were reconstructed as 36 1-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by means of Xe-133 clearance time. RESULTS: Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9 HU +/- 24.5, whereas lungs with obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6 HU +/- 20.1, P < .0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Lungs with restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In a total of 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance time (r = -.842). CONCLUSION: PDD by means of spiral CT is acceptable for the detection of ventilation abnormalities in obstructive airways disorder.

Adult↗

Quantitation of emphysema with three-dimensional CT densitometry: comparison with two-dimensional analysis, visual emphysema scores, and pulmonary function test results.

PURPOSE: To compare lung densitometric measurements that use a three-dimensional (3D) reconstruction of the lungs with those obtained from analysis of two-dimensional (2D) computed tomographic (CT) images, visual emphysema scores, and data from pulmonary function tests. MATERIALS AND METHODS: Thoracic helical CT scans were obtained in 60 adult patients (35 with no visual evidence of emphysema and 25 with emphysema). The lungs were reconstructed as a 3D model on a commercial workstation, with a threshold of -600 HU. By analysis of histograms, the proportions of lung volumes with attenuation values below -950, -910, and -900 HU were measured, in addition to mean lung attenuation. These values were compared with lung densitometric results obtained from 2D CT images, visual emphysema scores, and data from pulmonary function tests. RESULTS: Quantitation of emphysema with 3D reconstruction was efficient and accurate. Correlation was good among densitometric quantitation with 3D analysis, that obtained with 2D analysis (r = 0.98-0.99), and visual scoring (r = 0.74-0.82). Correlation was reasonable between 3D densitometric quantitation and the diffusing capacity of the lungs for carbon monoxide (DLCO) (r = -0.57 to -0.64), total lung capacity (r = 0.62-0.71), forced expiratory volume in 1 second (FEV1) (r = -0.57 to -0.60), and the ratio of FEV1 to forced vital capacity (FVC) (r = -0.75 to -0.82). The visual CT quantitation of emphysema correlated best with DLCO (r = -0.82) and FEV1/FVC (r = -0.89). CONCLUSION: Lung densitometry with 3D reconstruction of helical CT data is a fast and accurate method for quantifying emphysema.

Absorptiometry, Photon↗

[Indication of bone densitometry in women over 40 years of age].

OBJECTIVE: To evaluate the indication of bone densitometry (BD) and to know the prevalence of risk factors (FR) for osteoporotic fracture in primary care. DESIGN: Cross-sectional, descriptive study. SETTING: Urban centre of health of Terrassa, Barcelona (52.000 h). PARTICIPANTS: Women over 40 years old than went to urgencies of the centre selected by consecutive sampling stratified by age (n=416). MAIN MEASUREMENTS: Registry of FR for osteoporotic fracture according to the criteria of the Agència d'Avaluació de Tecnologies Mèdiques (AATM), hygienic-dietetic recommendations received and made BDs. RESULTS: The average age was of 60+/-13 years. The FR for osteoporotic fracture more prevalence were: low calcium intake (32.1%), increased age (27.5%), no lactation (24.9%), and precocious menopause (16.4%). They had received dietetic recommendations 35.7%, of exercise 65.5% and solar exhibition 18.1%. Of the 177 (42.7%) cases in that the BD was indicated only it made in 45 (25.4%) and of 237 (57.3%) without indication of BD they were made 41 (17.2%). To have made BD is related of statistically significant way to antecedent of osteoporotic fracture (P<.001) and to iatrogenic menopause (P<.001). The 41.2% of the BDs were asked for by the primary care physician, the 34.1% by the rheumatologist and the 16.5% by the gynaecologist. The indication of BD varies between the different scientific societies: AATM 42.7%, semFYC 45.7%, FORE 49.8%, SER 61.1%, and NOF 64.3%. CONCLUSIONS: Although FR of prevalence osteoporosis are most modifiable from primary care, a low degree of advice exists on healthful habits of life. A low accomplishment of BDs is detected and half is not adapted its indications according to the criteria of the AATM. There is great variability in the indication of BD between the different scientific societies.

Absorptiometry, Photon↗

Bone densitometry: assessing the effects of growth hormone treatment in adults.

Dual-energy X-ray absorptiometry (DXA) is the reference method for the measurement of bone mineral mass at different skeletal sites. It has been widely used in recent years to assess the effects of growth hormone (GH) treatment on bone metabolism. In normal individuals, bone mineral content (BMC) and density (BMD), as assessed using DXA, correlate with body size. Therefore, using DXA in patients with congenital GH deficiency (GHD), who have a smaller body frame, would be expected to result in lower bone mass. Thus, comparisons with reference data derived from populations of normal body size are invalid. The evaluation of the effects of GH administration should take into account the possible effects of GH on bone size, not only in children, but also in adults. The enlargement of bone, due to stimulation of the periosteal apposition, may partially mask an increase in BMC, resulting in little or no change in BMD. The ability of GH to affect bone area therefore requires analysis of the possible changes in bone area and BMC, as well as BMD. This issue has been poorly handled in the studies published to date. Lastly, the acceleration of bone turnover induced by GH leads to an increase in bone remodelling space, which in turn is associated with a reduction in BMC and BMD, independent of the net balance between breakdown and formation in each metabolic unit. This bone loss is completely reversible when the remodelling space returns to previous levels. This phenomenon must be taken into account when analysing the effects of GH treatment on bone mass, because a net gain in bone mass may be found in long-term GH treatment or after GH discontinuation, even if bone loss was evident during the first 6 months of treatment. In conclusion, the interpretation of bone density data in patients with GHD, and after GH administration, should take into account some of the methodological aspects of bone densitometry, as well as the specific actions of GH on bone metabolism and body composition.

Adult↗

Bone remodelling after total hip arthroplasty using an uncemented anatomic femoral stem: a three-year prospective study using bone densitometry.

PURPOSE: To evaluate the clinical, radiological, and densitometric changes in the bone-remodelling patterns of femoral stems aligned in neutral, valgus, or varus positions. METHODS: Between February and October 2000, 70 patients underwent unilateral total hip arthroplasty for primary osteoarthritis using an uncemented Anatomique Benoist Girard (ABG) II stem. 69 patients (30 males and 39 females) with a mean age of 59 years (range, 38-76 years) and a mean body weight of 79.3 kg (range, 29-110 kg) completed 3 years' follow-up on bone remodelling. The clinical, radiological, and densitometric changes of the neutral, valgus, and varus groups were evaluated, and the difference in bone-remodelling patterns between the 3 groups was analysed. RESULTS: 54 patients had neutrally placed stems, while varus and valgus malalignment occurred in 6 and 9 patients, respectively. Clinical and radiological evaluations were very similar among the 3 groups. Only densitometry could detect traceable changes resulting from the differing biomechanics of the neutral, varus, and valgus stem alignments. CONCLUSION: The ABG II stem design made moderate errors in alignment biomechanically tolerable. Alignment defects had no clinical consequences and resulted in minimal differences in bone remodelling.

Absorptiometry, Photon↗

Reproducibility of spirometrically controlled CT lung densitometry in a clinical setting.

The aim of this study was to assess the reproducibility of quantitative, spirometrically gated computed tomographic (CT) lung densitometry at defined levels of inspiration in hospitalized patients. On two consecutive days, spirometrically gated CT sections were obtained from 20 hospitalized patients at 5 cm above and 5 cm below the carina, and at 90 and 10% of the vital capacity (VC). The mean, modal and median lung densities were calculated, the cut-off points of the frequency distribution of Hounsfield units (HU) defining the lowest and the highest 10th percentile, as well as the histogram full width at half maximum. The lung density parameters of corresponding CT sections of both studies were compared. Reproducibility was expressed as the standard deviation of the signed difference between the results of Day 1 and Day 2 divided by the square root of 2. Reproducibility data were correlated with results of airflow limitation. At 90% VC, reproducibility was of the order of 3-14 HU in both lung zones. At 10% VC, reproducibility was worse by approximately a factor of three. No relationship was found between reproducibility and results of airflow limitation. In conclusion, objective measurement of lung density at spirometrically controlled levels of inspiration is a reproducible method in assessing pulmonary density. Reproducibility of lung density measurements is not influenced by severe respiratory insufficiency. The most reproducible computed tomographic lung density measurements can be obtained at 90% vital capacity.

Absorptiometry, Photon↗