Clinical and radiological results following cervical arthroplasty.

BACKGROUND: This was a retrospective study of clinical and radiological results of cervical arthroplasty using the Bryan cervical disc prosthesis to evaluate the efficacy of arthroplasty in clinical applications. METHODS: A total of 46 patients underwent arthroplasty of a single level using the Bryan disc prosthesis. Clinical outcome was assessed using the visual analogue scale (VAS) and the neck disability index (NDI). All patients were evaluated using preoperative and postoperative static cervical spine radiographs to compare cervical sagittal balance. Dynamic cervical spine radiographs were used to compare movement at the level of the procedure, movement at the adjacent level and movement of the whole cervical spine. FINDINGS: With the exception of four patients with aggravated neck pain, the NDI and VAS scores decreased significantly in late follow-up evaluations. The range of movement of the whole cervical spine, the functional segmental unit, and the adjacent segments were preserved after arthroplasty. The sagittal alignment of the cervical spine showed kyphosis after surgery but restored lordosis at a later time. The postulated cause of kyphotic changes include "over-milling" at the dorsal endplate, inappropriate angle of disc insertion, structural absence of lordosis in the Bryan disc, removal of posterior longitudinal ligament, and pre-existing kyphosis. CONCLUSIONS: Arthroplasty using the Bryan disc appears to be safe and provided a favorable preliminary clinical and radiological outcome. Postoperative kyphosis can be prevented by understanding the biomechanical properties of the Bryan disc. Future studies will need to address the association between postoperative kyphosis, clinical outcome and adjacent segment disease.

Adult↗

Perioperative morbidity and 30-day mortality after intertrochanteric hip fractures treated by internal fixation or arthroplasty.

The conventional treatment for intertrochanteric hip fracture is open reduction and internal fixation. However, hip arthroplasty is occasionally performed. The objective of this study was to determine the 30-day mortality for patients with intertrochanteric hip fracture treated with open reduction, internal fixation, or hip arthroplasty. The mortality rate for patients treated with arthroplasty at 4.8% (23/478) was slightly, but not significantly, higher than that for patients treated with open reduction and internal fixation at 4.5% (62/1395). However, more of the patients in the arthroplasty group exhibited serious intraoperative cardiorespiratory disturbances (62% vs 22%) and died in the hospital (77% vs 35%) when compared with the patients in the open reduction and internal fixation group. Although the incidence of 30-day mortality in these groups was not significantly different, the patients in the arthroplasty group were more likely to have a complicated intraoperative course and die in the hospital.

Adult↗

Pyrolytic carbon arthroplasty for posttraumatic arthritis of the proximal interphalangeal joint.

PURPOSE: To prospectively evaluate the subjective and objective functional outcome of patients treated with a pyrolytic carbon proximal interphalangeal (PIP) joint arthroplasty for posttraumatic arthritis. METHODS: Five patients (7 joints) with traumatic injuries to the PIP joint were followed up for more than 1 year after pyrolytic carbon arthroplasty. All patients were treated with surgical reduction and stabilization at the time of the initial injury, but at a minimum of 6 months after the initial injury they had persistent pain, loss of motion, and functional limitations. All patients had a stable PIP joint with a satisfactory extensor mechanism but had radiographic evidence of posttraumatic arthritis. Patients were evaluated before and after arthroplasty with the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and visual analog scale and by radiographic and physical examination. RESULTS: At an average of 17 months, the mean DASH questionnaire score was unchanged. The pain rating on the visual analog scale was 6 out of 10 before surgery and 4 out of 10 after surgery; this change was not statistically significant. The average range of motion of the PIP joint decreased by 10 degrees at the last evaluation. Grip strength improved from an average of 47 lb to 63 lb after surgery. CONCLUSIONS: The subjective and objective functional outcomes in 5 patients more than 1 year after pyrolytic carbon PIP joint arthroplasty for PIP joint trauma were disappointing. For posttraumatic patients, we no longer use pyrolytic carbon PIP joint arthroplasty.

Adult↗

Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome.

The purpose of this study was to document the diagnosis, surgical treatment, and functional outcome in patients with subscapularis ruptures after shoulder arthroplasty. Prospective objective and subjective data were collected on 7 patients with symptomatic rupture of the subscapularis tendon after shoulder arthroplasty. Presenting signs and symptoms included pain, weakness in internal rotation, increased external rotation, and anterior instability. All patients were treated with surgical repair of the ruptured tendon. Four required repair augmentation with a transfer of the pectoralis major tendon. After subscapularis repair and pectoralis transfer, 2 patients continued to have anterior instability and required an additional operation to address the instability. At a mean follow-up of 2.3 years (range, 18-55 months), the mean American Shoulder and Elbow Surgeons shoulder score in this study group was 63.2. The mean patient satisfaction rating, on a 10-point scale, was 6.2. Factors associated with post-arthroplasty subscapularis ruptures included subscapularis lengthening techniques used to address internal rotation contracture and previous surgery that violated the subscapularis tendon. Symptomatic subscapularis rupture after shoulder arthroplasty introduces the need for additional surgery and a period of protected or delayed rehabilitation after arthroplasty. Although symptoms were adequately addressed with appropriate surgical treatment, decreased functional outcomes were observed.

Adult↗

Biomechanical effects of glenoid retroversion in total shoulder arthroplasty.

The purpose of this study was to evaluate the effects of glenoid retroversion after total shoulder arthroplasty on glenohumeral joint contact pressures, contact areas, and forces. We studied 8 cadaveric shoulders with a custom shoulder testing system that permits anatomic loading of the rotator cuff and the humerothoracic muscles. Each shoulder was tested intact and after total shoulder arthroplasty with the glenoid component in a neutral position and with the glenoid component retroverted 15 degrees . Glenohumeral contact pressures and areas were measured with Fuji pressure-sensitive film, and the glenohumeral forces were measured with a 6-df load cell. Glenohumeral contact areas decreased significantly, and contact pressures increased after total shoulder arthroplasty with both neutral glenoid components and retroverted glenoid components (P < .0002 to .04). Inferior forces decreased significantly after total shoulder arthroplasty with the retroverted glenoid components when compared with the intact, native shoulder (P < .02). Posterior forces also decreased significantly with the retroverted glenoid when compared with the neutral glenoid (P < .03). Placement of the glenoid in 15 degrees of retroversion significantly decreased glenohumeral contact area, increased contact pressure, and decreased inferior and posterior glenohumeral forces. Glenoid component retroversion may result in eccentric loading of the glenoid component and possibly lead to wear and loosening, signifying the importance of correct anatomic placement during total shoulder arthroplasty.

Arthroplasty, Replacement↗

Basic scientific considerations in total disc arthroplasty.

BACKGROUND CONTEXT: Total disc arthroplasty serves as the next frontier in the surgical management of intervertebral discogenic pathology. PURPOSE: As we move from an era of interbody spinal arthrodesis to one in which segmental motion is preserved, this promising new technology offers increasing clinical and research challenges in the areas of spinal kinematics, histologic osseointegration at the prosthetic-bone interface and the effects of particulate wear debris. STUDY DESIGN: The primary focus of this paper is to provide a methodologic basis to investigate the spinal kinematics, histologic osseointegration and particulate wear debris after total disc arthroplasty by using in vitro and in vivo models. METHODS: Part I: Using an in vitro cadaveric model, multidirectional flexibility testing evaluated the functional unit kinematics under the following L4-L5 reconstruction conditions: 1) intact spine, 2) Charite disc prosthesis, 3) BAK cages, 4) BAK cages+ISOLA pedicle screw or rod fixation (anteroposterior). Part II: A total of 27 mature baboons (n=27, Papio cynocephalus) underwent L5-L6 total disk replacement procedures to investigate the biomechanical, histochemical and biologic ingrowth characteristics of two different lumbar disc prostheses (AcroFlex and Charite) for total disc arthroplasty. Functional spinal unit fusion status was assessed by using radiographic analysis, biomechanical testing, undecalcified histopathologic and histomorphometric analyses. Part III: Using a total of 50 New Zealand white rabbits, this investigation served to quantify the neural and systemic tissue histopathologic response, after epidural application of four different types of spinal instrumentation particulate wear debris: 1) sham (control) (n=10), 2) stainless steel 316LVM (n=10), 3) titanium alloy Ti-6AL-4V (n=10), 4) cobalt chrome alloy (n=10) and 5) ultrahigh molecular weight polyethylene (UHMWPE) (n=10). RESULTS: In vitro multidirectional flexibility testing demonstrates the operative and adjacent level motion-preserving properties of total disc arthroplasty versus interbody arthrodesis cages and pedicle screw spinal instrumentation. To this end, disc replacement preserves the normal centrode or locus of intervertebral rotation at the operative and adjacent intervertebral spinal levels compared with conventional stabilization implants. On the basis of nonhuman primate modeling in the current studies, porous titanium interface surfaces afforded the greatest percentage of trabecular ingrowth at the prosthesis-end plate interface. In vivo segmental motion under multidirectional testing was preserved with the Charite device and slightly diminished with the AcroFlex implants. The porous ingrowth coverage at the bone-metal interface was more favorable for total disk replacement (range, 40% to 50%) compared with that reported for cementless total joint components in the appendicular skeleton (range, 10% to 30%). Direct epidural application of spinal instrumentation particulate wear debris elicits a chronic histiocytic reaction localized primarily within the epidural fibrous layers. Moreover, particles have the capacity to diffuse intrathecally, eliciting a macrophage and cytokine response within the epidural tissues, cerebrospinal fluid and spinal cord itself. Overall, on the basis of the postoperative time periods evaluated, no evidence was observed of an acute neural or systemic histopathologic response to the materials included in the current project. CONCLUSION: The implementation of dynamic spinal stabilization systems for fusionless correction of spinal deformity, dynamic posterior stabilization and total disc arthroplasty necessitates improved understanding with regard to spinal kinematics, patterns and mechanisms of histologic osseointegration and the neurohistopathologic response to particulate wear debris. Collectively, the current studies provide a methodologic basis to comprehensively evaluate these three areas.

Animals↗

[Total hip arthroplasty after failure of per- and subtrochanteric fracture fixation in elderly subjects].

PURPOSE OF THE STUDY: Most pertrochanteric fractures can be successfully fixed with osteosynthesis. Osteosynthesis fails however is a small number of patients who require re-operation for implantation of a total hip prosthesis. This situation occurs in particular when the material has penetrated the acetabulum and in elderly subjects. Although this type of arthroplasty is routine practice, few series have been reported. We present here outcome and complications of total hip arthroplasty after failure of per- and sub-trochanteric fracture fixation. MATERIAL AND METHODS: Between 1990 and 2000, twenty patients aged 79 years on average (range 62-78 years) underwent revision for total hip arthroplasty after failure of osteosynthesis for fracture of the upper femur. A gliding THS had been used for fixation in 18 patients, a plate in one and a Gamma nail in one. Osteosynthesis failure was related to early disassembly in ten patients, pseudarthrosis in eight and malunion in two. Revision was performed via a posterolateral approach in all cases. A standard total hip prosthesis was used in 16 patients, a longer femoral stem was required in four. Femoral components were cemented in 18 patients and non-cemented in two. The cup was a standard cemented cup in 12, retaining and cemented in eight. RESULTS: Mean operative time and blood loss were greater than in first-intention arthroplasties. All patients had lost their independence prior to the revision procedure. Despite their age, all recovered independence after a stay in rehabilitation. Most still required crutches. Use of a retaining cup enabled avoiding dislocation in all cases. For those who did not have a retaining cup, dislocation was the most frequent complication (3/12). The difficulties observed were: 1) elimination of associated infection before surgery; many of these elderly subjects had altered ESR and CRP values for various reasons; 2) abnormal position of the trochanteric mass because of a rotation defect; 3) malunion of the upper femur in the frontal or sagittal planes; 4) more or less easily achieved positioning of the femoral piece on the calcar; 5) difficult intraoperative identification of limb length due to loss of usual landmarks on the lesser and greater trochanter; 6) removal of fracture screws which sometimes required use of a trephine and bridging the last screw hole with a longer centromedullary stem. The most frequent postoperative orthopedic problems were leg length discrepancy (1-2 cm for eight patients), gluteus medius insufficiency, limping and pain at palpation of the trochanteric area. DISCUSSION: Despite the difficult technique and the potential complications which are more important than for first-intention arthroplasties, this series demonstrates that total hip prosthesis is a reliable solution for treating fixation failures of the upper femur.

Age Factors↗

Three-dimensional gait analysis in women with a total hip arthroplasty.

OBJECTIVES: The purposes of this study were: (1) to identify the primary (hip) and secondary (neighboring joints) impairments during gait in subjects with a total hip arthroplasty total hip arthroplasty, (2) to determine which impairments persist when controlling for gait speed and (3) to study the relationships between primary and secondary impairments in order to describe the locomotor strategies used by these patients.DESIGN. This cross-sectional study compared the gait patterns of women with a total hip arthroplasty to those of healthy women.BACKGROUND. Several studies have reported residual hip impairments in the sagittal plane during gait after a total hip arthroplasty. There is, however, a substantial lack of knowledge in regard to the changes at the neighboring joints and in the other planes of movement.METHODS. Subjects have been examined during a gait laboratory testing session including the simultaneous recording of three-dimensional kinematics and ground reaction forces on one side, and bilateral activation of six lower limb muscles.RESULTS. A significant decrease of 20% in the hip extensor moment of force during the early stance phase was correlated (R(2)=43%) with a significant decrease of 14% in gait speed. Moreover, a significant decrease of 59% in the range of hip extension at the end of the stance phase was observed together with secondary impairments such as a significant increase in the anterior pelvic rotation, in knee flexion and in ankle dorsiflexion. Lastly, a significant increase in ipsilateral bending of the trunk during the single limb support on the operated limb was concomitant with a significant decrease in the hip abductor moment of force.CONCLUSIONS. The decrease in gait speed and the persistence of abnormal gait patterns one year after the total hip arthroplasty were associated respectively with a decrease in the hip extensor moment of force and with a decrease in the range of hip extension (sagittal plane) or in the hip abductor moment of force (frontal plane). RelevanceThe data provided in this paper may serve as guidelines to establish rehabilitation programs designed to restore optimal locomotor function.

Adaptation, Physiological↗

The long-term outcome of volar plate arthroplasty of the proximal interphalangeal joint.

The ultimate effectiveness of an arthroplasty is most accurately determined by a long-term review of the joints' function and freedom from pain. We examined 17 patients an average of 11.5 years (range, 4-26 years) following volar plate arthroplasty for a fracture-dislocation of the proximal interphalangeal joint. All surgeries were performed by the same surgeon. The average age was 36 years (range, 17-61 years). No patient complained of pain at rest or with activity. Patients having arthroplasty within 4 weeks of injury attained a total active range of motion of 85 degrees (50 degrees to 110 degrees ). Patients having arthroplasty more than 4 weeks after injury (average, 20 weeks) included several elderly women and averaged 61 degrees (30 degrees to 90 degrees ) total active range of motion. Four patients showed some degree of joint narrowing at the follow-up examination. This review suggests that volar plate arthroplasty continues to be of benefit on a long-term basis and provides satisfactory function and pain-free motion.

Adolescent↗

Comparison of arthroplasty and arthrodesis for the rheumatoid wrist.

PURPOSE: To compare the outcomes of wrist arthrodesis and arthroplasty in the treatment of rheumatoid arthritis using validated outcome patient surveys and a review of surgical complications in 2 matched cohorts. METHODS: Forty-six patients with 51 operated wrists (24 arthrodeses and 27 arthroplasties) were reviewed retrospectively at a follow-up range of 1 to 5 years. Patients completed the Disabilities of the Arm, Shoulder and Hand (DASH) inventory, the Patient-Rated Wrist Evaluation (PRWE), and a questionnaire designed specifically for this study. Surgical complications were obtained by chart review. RESULTS: Treatment groups were well matched by patient characteristics and radiographic staging. There were no statistical differences in the survey scores between the 2 groups. Patients in the arthroplasty group, however, reported a trend toward greater ease with personal hygiene and fastening buttons. Complication rates were similar with a 56% complication rate in the arthrodesis group (22% major, 35% minor) and a 52% complication rate in the arthroplasty group (11% major, 41% minor). CONCLUSIONS: The DASH and PRWE may not be designed properly to measure impairment caused by wrist disease in patients with generalized arthritis. The results show that patients with rheumatoid arthritis can and do accommodate to a wrist arthrodesis. It should not be construed, however, that patients with rheumatoid arthritis would not prefer or obtain greater benefit from a wrist arthroplasty [corrected].

Arthritis, Rheumatoid↗

First metacarpal subsidence during pinch after ligament reconstruction and tendon interposition basal joint arthroplasty of the thumb.

Trapeziectomy, ligament reconstruction and tendon interposition arthroplasty is one of the most commonly performed procedures to address pain and instability due to osteoarthritis at the basal joint of the thumb. To determine the effect of stress on first metacarpal subsidence, 15 ligament reconstruction and tendon interposition basal joint arthroplasties were evaluated after a mean follow-up of 32 months. Radiographs were obtained of the arthroplasty at rest and then with maximal effort key pinch stress, which is known to subject the first carpometacarpal joint to considerable axial compression stress. Compared with the preoperative x-rays, the first metacarpal had subsided 21% of the arthroplasty space at rest. Under stress, the first metacarpal was found to subside another 10.5% in height. No subluxation of the metacarpal base could be detected. Key pinch strength improved 17% from the preoperative strength. Tip-to-tip pinch strength improved 17% from the preoperative measurement. Grip strength improved 17% from the preoperative measurement. Grip strength was 9% greater than the preoperative grip strength. There was no statistical association between the amount of first metacarpal subsidence and follow-up key pinch, tip pinch, or grip strength. With axial compressive loading of the arthroplasty, such as in lateral pinch, there is some further proximal migration of the first metacarpal, but this is minimal and does not correlate with functional outcome.

Adult↗

Impingement syndrome following total shoulder arthroplasty and humeral hemiarthroplasty: treatment with arthroscopic acromioplasty.

Pain following total shoulder arthroplasty or humeral hemiarthroplasty is uncommon. Impingement syndrome can be an infrequent source of pain following shoulder arthroplasty. We retrospectively reviewed six patients with refractory impingement syndrome treated with arthroscopic acromioplasty following either total shoulder arthroplasty (four patients) or humeral hemiarthroplasty (two patients). Chronic impingement syndrome requiring acromioplasty affected 3% of all patients who underwent total shoulder arthroplasty or humeral hemiarthroplasty during the study period. A thorough history, physical examination, and radiographic findings made the clinical diagnosis of impingement syndrome. All six patients had positive impingement signs and a positive impingement test with subacromial lidocaine injection. Preoperative radiographs revealed a type II or III acromion and subacromial outlet narrowing in five of six patients. Other sources of shoulder pain including prosthesis loosening, infection, and rotator cuff tear were ruled out preoperatively by physical examination and radiographic findings, and were confirmed by arthroscopic examination. The results of arthroscopic acromioplasty were a reduction in pain from 7.5 preoperatively to 1.6 postoperatively, on a scale from 0 to 10. Five of six patients were completely satisfied with the results of their arthroscopic surgery. Overall, according to the University of California at Los Angeles end-result score, the results were rated as excellent or good in five patients, and unsatisfactory in one patient. Arthroscopic acromioplasty can be a successful technique for the treatment of chronic impingement syndrome following total shoulder arthroplasty or hemiarthroplasty in appropriate patients.

Acromion↗

Femoral cement grading in total hip arthroplasty.

The current gold standard for primary total hip arthroplasty is a cemented femoral component combined with a porous-coated acetabular component. Barrack and colleagues described a femoral cement mantle grading system which is increasingly being used to evaluate surgical technique and to compare arthroplasty results. The immediate postoperative radiographs of 100 primary total hip arthroplasty cases from five community surgeons were assessed by three observers to evaluate the overall quality of cement technique, the interobserver variability in cement mantle grading, and specific characteristics of the grading system. All three observers agreed on the grading in only 73% of the x-rays (anteroposterior view, 69%; lateral view, 77%). Compared with reports in the literature from specialized hip arthroplasty centers, a very high proportion of the cases had grade C mantles. To gain a balanced perspective of the global effectiveness and longevity of cemented total hip arthroplasty it is important that follow-up studies be reported upon from representative cross sections of the orthopaedic community.

Acetabulum↗

Results of 2-stage reimplantation for infected total knee arthroplasty.

Optimum treatment of the infected total knee arthroplasty has not been clearly established. To clarify the efficacy of two-stage reimplantation, experience with 66 infected total knee arthroplasties in 64 patients who had been treated with 2-stage reimplantation total knee arthroplasty between September 1980 and October 1993 was reviewed. Of these, 55 knees in 54 patients were available for follow-up examinations at an average of 61.9 months (range, 28-146 months). The initial diagnoses were rheumatoid arthritis (14 knees) and osteoarthritis (41 knees). Reimplantation was successful in 80.0% of knees with low-virulence organisms (coagulase-negative Staphylococcus, Streptococcus), 71.4% with polymicrobial organisms, and 66.7% with high-virulence organisms (methicillin-resistant Staphylococcus aureus). Reimplantation was successful in 82% of patients with osteoarthritis and in 54% of patients with rheumatoid arthritis (P = .024). The success rate was 92% if infection occurred after primary arthroplasty but only 41% if after multiple previous knee operations (arthroscopy, osteotomy, or revision total knee arthroplasty) (P < .001).

Adult↗

Vertical ground reaction forces: objective measures of gait following hip arthroplasty.

After hip arthroplasty, many patients continue to exhibit abnormal gait patterns. The purpose of this study was to compare the vertical ground reaction forces of a group of 27 individuals who have undergone hip arthroplasty with a group of 35 normal control subjects. Specific force measures were determined from vertical ground reaction forces collected on a treadmill instrumented with two force plates. Symmetry indices were calculated on both groups of subjects. First and second peak forces, loading rate, impulse, and stance time were significantly less, while time to first peak force was significantly greater on the affected leg of the hip arthroplasty subjects when compared to their unaffected leg, or to the control group. The hip arthroplasty group showed greater asymmetry of ground reaction forces than the control group did. Bilateral asymmetric limb loading persists well after unilateral hip replacement surgery. Ground reaction force measures have been shown to be an effective means of quantifying the antalgic gait of hip arthroplasty patients.

Adult↗

Semiconstrained total elbow arthroplasty in the context of treated previous infection.

Previous infection has been considered a strict contraindication to implantation or reimplantation of an elbow prosthesis. The purpose of this study was to investigate whether these patients can in fact be successfully treated with a prosthetic arthroplasty given previous treatment of the infection. Ten consecutive prosthetic arthroplasties performed in patients with documented infections in the elbow were retrospectively reviewed. Seven of the patients had infectious complications of total elbow arthroplasties that led to resection. Two patients had previous infections from septic joints and 1 from open reduction internal fixation. The median interval of time from infection treatment to final implant was 45 months (3.8 years). All arthroplasties were performed by the same surgeon with a modified Coonrad-Morrey, semiconstrained prosthesis. Patients were monitored for clinical signs of infection including radiographic and serologic studies and clinical evaluation based on the Mayo Elbow Performance Score. Mean surveillance was 4 years (range 2.8 to 5.4 years). Eight of the 10 cases have not shown signs of infection at the latest assessment. Two have had recurrent infections. The time interval from the original infection to latest implantation did not correlate with infection recurrence. Among those 8 without recurrent infection, 7 had excellent and 1 had satisfactory results according to the Mayo Elbow Performance Score. The recurrent infections were rated as failures. The average score was 32 before and 81 after surgery. The average pain score was 15 before surgery, and the average postoperative pain score was 40. Salvage of previously infected elbows with prosthetic arthroplasty can provide excellent results in a significant proportion of patients. Although the procedure offers superior functional outcomes compared with the alternative treatment options, it is technically demanding.

Aged↗

Tendon interposition arthroplasty versus arthrodesis for the treatment of trapeziometacarpal arthritis: a retrospective comparative follow-up study.

Long-term subjective and objective outcomes of 24 tendon interposition arthroplasties in 17 patients and 32 trapeziometacarpal (TMC) arthrodeses in 26 patients were compared retrospectively in a standardized manner. Tendon interposition arthroplasty led to complications less often (27%) than TMC arthrodesis (39%). Patients in the tendon interposition arthroplasty group reported significantly less pain, less temperature intolerance, and better thumb mobility and were more satisfied with pain symptoms than patients in the arthrodesis group. Patients undergoing tendon interposition arthroplasty had better thumb opposition, interphalangeal joint mobility, and radial and palmar TMC joint range of motion. No statistically significant differences were found in tip pinch, key pinch, and grip strength between the 2 groups. Proximal first metacarpal collapse occurred in the tendon interposition patients without affecting subjective or objective outcome. Seven of 25 patients with TMC arthrodesis had pseudarthrosis. Tendon interposition arthroplasty seems to be preferable to TMC joint arthrodesis for the treatment of TMC arthritis.

Aged↗

Use of continuous passive motion after total knee arthroplasty.

Sixty primary total knee arthroplasties in 43 Chinese patients were included into a prospective study. Twenty-six patients who had unilateral knee arthroplasty were randomized to receive continuous passive motion (CPM) or immobilization in the first week. The 2 groups of patients were comparable in demographic data and preoperative knee range of motion (ROM). In 17 patients who had 1-stage sequential bilateral arthroplasties, one side had CPM and the other side was immobilized. The active knee ROM was assessed regularly until 1 year after the operation. For all patients, the early active knee ROM in the CPM group was significantly better than the immobilization group. There was no difference after 7 days, however. For patients who had 1-stage bilateral total knee arthroplasties, the active knee ROM was significantly better on the CPM side until day 28. After 4 weeks, there was no difference between the CPM group and the immobilization group. Immobilization after total knee arthroplasty does not preclude good ROM.