Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “high throughput”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

High-throughput fluorescence polarization method for identifying ligands of LOX-1.

AIM: To develop and optimize a competitive fluorescence polarization (FP) method, and use it as a high-throughput screening (HTS) assay for drug discovery. METHODS: Human lectin-like oxidized low-density lipoprotein receptor-1 (hLOX-1) and oxidized low-density lipoprotein (oxLDL) were used to establish a high-throughput fluorescence polarization assay to screen ligands of human LOX-1. A 96-well plate assay was performed with a fast plate reader. Three fluorescein isothiocyanate-labeled hLOX-1 concentrations (100, 200, and 400 nmol/L) were selected to be titrated by oxLDL (from 0.05 nmol/L to 100 micromol/L) in order to obtain optimal reactive concentrations. The concentration of Me2SO used (0%, 1%, 3%, 5%) and incubation time (15 min, 30 min, 1 h, 2 h) were optimized. The Z' factor was calculated to estimate the quality of FP-based HTS. RESULTS: Concentrations of 200 nmol/L for human LOX-1 and 50 micromol/L for oxLDL were used in the actual assay. Concentrations of 0% to 5% Me2SO and different reaction times did not affect the FP-based HTS. The Z' value was 0.66. By using this detection and screening system, 12 700 compounds were screened and 3 ligands with an IC50 of less than 4.5 micromol/L were found. CONCLUSION: The established competitive FP-based assay is sensitive, stable, highly reproducible and robust, and suitable for HTS for ligands of the hLOX-1 receptor.

Binding, Competitive↗

Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification.

A continuous segmented-flow method for sequential DNA amplification is described in order to provide a basis for high-throughput genetic analysis. The approach allows an immediate distinction between amplified and nonamplified products. A mixture of sample and reagents are loaded in the form of small segments one after another in a 15-m-long narrow-bore Teflon tube, coiled such as to be repeatedly exposed to three different temperature zones. After having passed the heated zones, the samples are mixed with an intercalating dye by flow injection and sequentially detected on-line by laser-induced fluorescence. The aqueous samples travel as separate segments in a continuous flow of an immiscible, organic liquid. Perfluorodecalin was shown to be particularly suitable due to its hydrophobicity and inert properties. To reduce carryover between samples, an intermediate water plug between two consecutive samples was required. Selected regions from human genomic DNA were successfully amplified in 300-nL volumes after 30 passes through the heated zones. The total reaction time was approximately 45 min, and the detection interval between individual samples was 1 min. Automation and the possibility to further reduce sample volumes, as well as to employ many reaction columns simultaneously, should provide a platform for an extremely high throughput.

Automation↗

Automated extraction of viral-pathogen RNA and DNA for high-throughput quantitative real-time PCR.

The performance of the m1000 system (Abbott Laboratories, Illinois) as a front-end extraction system for high-throughput "in-house" quantitative real-time PCR assays was analyzed and compared to that of manual extraction of plasma and serum samples (hepatitis C virus [HCV] and hepatitis B virus [HBV]) and EDTA-blood samples (cytomegalovirus [CMV] and Epstein-Barr virus [EBV]). Linearity of extraction was tested on dilution series of HCV and HBV reference materials. The correlation coefficient for standard curves based on repeated extraction runs was 0.97 +/- 0.06 for HCV and 0.97 +/- 0.03 for HBV, indicating a linear extraction from 100 to 1.0 x 10(5) HCV IU/ml and from 100 to 1.0 x 10(6) HBV IU/ml. Intra- and interrun variability was below 0.23 log(10) IU/ml for 2.98 to 5.28 log(10) HCV IU/ml and 2.70 to 5.20 log(10) HBV IU/ml. Correlation between automated and manual extraction was very good. For HCV, the correlation coefficient was 0.91 and the mean difference in viral load was 0.13 log(10) HCV IU/ml. For HBV, the correlation coefficient was 0.98 and the mean difference in viral load 0.61 log(10) HBV IU/ml. For CMV and EBV, the correlation coefficient was 0.98 and the mean difference in viral load 0.33 log(10) copies/ml. Accuracy was confirmed with a reference panel (QCMD, Glasgow, Scotland) for all four assays. No cross-contamination was observed when extracting strongly positive polyomavirus samples (8.10 log(10) copies/ml) interspersed with polyomavirus-negative samples. Automated extraction via the m1000 system offers a high reliability of extraction and resulted in a strong reduction of the required extraction hands-on time for high-throughput PCR compared to manual extraction protocols.

Automation↗

High-throughput analysis of nucleic acid modification reactions using ion-pair reverse-phase high-performance liquid chromatography.

Ion-pair reverse-phase high-performance liquid chromatography is presented as a versatile platform for the rapid analysis of nucleic acid modification reactions in a high-throughput manner. This system allows both sensitive and nonradioactive assays to be developed for a variety of nucleic acid modification reactions. Examples presented here include assays for telomerase, uracil DNA glycosylase, polynucleotide kinase, T4 DNA ligase, C5-DNA methyltransferases, and the mismatch endonuclease CEL I. However, this approach is not confined to these reactions. Indeed the ability to perform a variety of nonradioactive assays with throughput times of 10 min per sample in conjunction with automated data analysis software represents a significant improvement in analytical and preparative nucleic acid enzymology.

Chromatography, High Pressure Liquid↗

Glass bead purification of plasmid template DNA for high throughput sequencing of mammalian genomes.

To meet the new challenge of generating the draft sequences of mammalian genomes, we describe the development of a novel high throughput 96-well method for the purification of plasmid DNA template using size-fractionated, acid-washed glass beads. Unlike most previously described approaches, the current method has been designed and optimized to facilitate the direct binding of alcohol-precipitated plasmid DNA to glass beads from alkaline lysed bacterial cells containing the insoluble cellular aggregate material. Eliminating the tedious step of separating the cleared lysate significantly simplifies the method and improves throughput and reliability. During a 4 month period of 96-capillary DNA sequencing of the Rattus norvegicus genome at the Baylor College of Medicine Human Genome Sequencing Center, the average success rate and read length derived from >1 800 000 plasmid DNA templates prepared by the direct lysis/glass bead method were 82.2% and 516 bases, respectively. The cost of this direct lysis/glass bead method in September 2001 was approximately 10 cents per clone, which is a significant cost saving in high throughput genomic sequencing efforts.

Animals↗

High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Amines↗

Sugar-coated microarrays: a novel slide surface for the high-throughput analysis of glycans.

The development of DNA and protein microarrays represents a significant advance in transcriptomics and proteomics research. Such arrays allow the high-throughput, parallel analysis of protein occurrence and interactions and gene expression. However, this advance has not been matched by equivalent technology for analysis of glycomes. One reason for this is that compared to proteins, it is difficult to reliably immobilise populations of chemically and structurally diverse glycans. We describe the development of a new microarray slide surface to which diverse glycan structures can be directly immobilised without prior derivatisation of the slide surface or any modification of the arrayed samples. The slides can be used to produce comprehensive microarrays of carbohydrates, glycoproteins and proteoglycans using isolated samples or cell extracts. Using standard microarray equipment, a series of carbohydrate microarrays were generated and probed with a panel of monoclonal antibodies with specificities for glycan epitopes. The arrays were highly reproducible, stable, and could be stored dry for several months. Glycans play central roles in development, carcinogenesis, cell adhesion, and immunity and are increasingly the subject of therapeutic approaches. We anticipate that the development of carbohydrate microarrays will be important for the high-throughput analysis of glycans and their molecular interactions.

Animals↗

High-throughput photometric titrimetry based on a feedback-based and subsequent fixed triangular wave-controlled flow ratiometry.

The principle of flow ratiometry for high-throughput titration, which we recently proposed for potentiometric titration, was extended to photometric titration. The flow rate (FB) of a base solution containing an acid-base indicator was linearly varied in response to a control voltage (Vc) generated from a computer. With the total (acid + base) flow rate (FT) being kept constant, the base solution was merged with an acid solution, which was aspirated to the confluence point at a flow rate of FT - FB. Downstream, the relative transmittance of the mixed solution was measured at the maximum absorption wavelength of the base form of the indicator. Initially, a feedback-based control was applied, where the scan direction of Vc was reversed from upward to downward, and vice versa, whenever the transition of the indicator at the equivalence point (EP) was sensed. Next, the scan range of V. was further limited to the range just around EP by using fixed triangular waves. These processes avoided scanning in a range of no interest. Thus, an unprecedentedly high throughput rate (maximally 34 titrations per minute, corresponding to 1.76 s per titration) was realized with reasonable precision (RSD < 0.5%).

Algorithms↗

An oligonucleotide microarray for high-throughput sequencing of the mitochondrial genome.

Previously we developed an oligonucleotide sequencing microarray (MitoChip) as an array-based sequencing platform for rapid and high-throughput analysis of mitochondrial DNA. The first generation MitoChip, however, was not tiled with probes for the noncoding D-loop region, a site frequently mutated in human cancers. Here we report the development of a second-generation MitoChip (v2.0) with oligonucleotide probes to sequence the entire mitochondrial genome. In addition, the MitoChip v2.0 contains redundant tiling of sequences for 500 of the most common haplotypes including single-nucleotide changes, insertions, and deletions. Sequencing results from 14 primary head and neck tumor tissues demonstrated that the v2.0 MitoChips detected a larger number of variants than the original version. Multiple coding region variants detected only in the second generation MitoChips, but not the earlier chip version, were further confirmed with conventional sequencing. Moreover, 31 variations in noncoding region were identified using MitoChips v2.0. Replicate experiments demonstrated >99.99% reproducibility in the second generation MitoChip. In seven head and neck cancer samples with matched lymphocyte DNA, the MitoChip v2.0 detected at least one cancer-associated mitochondrial mutation in four (57%) samples. These results indicate that the second generation MitoChip is a high-throughput platform for identification of mitochondrial DNA mutations in primary tumors.

Base Sequence↗

High-throughput differential screening of mRNAs by serial analysis of gene expression: decreased expression of trefoil factor 3 mRNA in thyroid follicular carcinomas.

To find mRNAs whose expression differs between thyroid follicular adenomas and carcinomas, a high-throughput analysis of mRNAs in these two tumours was performed. This method, named high-throughput differential screening by serial analysis of gene expression (HDSS), combines a modified method of serial analysis of gene expression (SAGE) and real-time quantitative reverse transcription polymerase chain reaction (RT-PCR). A total of 40 candidate tag sequences that showed extremely different expression levels between a follicular carcinoma and a follicular adenoma in the SAGE analysis were analysed by real-time quantitative RT-PCR, using RNAs from an additional four typical follicular carcinomas and adenomas. One sequence tag that represents trefoil factor 3 (TFF3) mRNA showed a clear difference in its expression level between adenomas and carcinomas. The expression levels of TFF3 mRNA in 48 follicular adenomas and 29 follicular carcinomas were measured by real-time quantitative RT-PCR using a specific probe for TFF3. They were significantly decreased in follicular carcinomas, especially in widely invasive types and those with evident metastases. These results indicate that the decreased expression of TFF3 mRNA is a marker of follicular carcinomas, especially those with a high risk of invasion or metastasis.

Adenocarcinoma, Follicular↗

A multi-modality assay platform for ultra-high throughput screening.

The demand for increased throughput during primary screening using less reagents is changing the way of drug discovery. Searching for hits using high throughput screening in 96-well format plates is being replaced by the use of higher density plates, such as 384 and 1536-well formats. The analysis of radiometric assays by scintillation counters is becoming limiting since only 12 wells can be counted at a time. Charged coupled device (CCD) camera based instruments, that image the whole plate in one exposure, speed up detection and are compatible with any microplate footprint. Researchers are also demanding a choice of detection methods, including fluorescence, luminescence and radioactivity, and require imagers suitable for all applications. LEADseeker Homogenous Imaging System is a multi-modality platform offering imaging technology and assay toolboxes for radiometric, fluorescent and luminescent based assays. LEADseeker allows the very rapid analysis of high density formats enabling ultra-high throughput screening of a range of biological assays. Research areas that can be studied using this system include enzyme assays, receptor binding and molecular interactions.

Drug Design↗

Continuous-flow high pressure hydrogenation reactor for optimization and high-throughput synthesis.

This paper reports on a novel continuous-flow hydrogenation reactor and its integration with a liquid handler to generate a fully automated high-throughput hydrogenation system for library synthesis. The reactor, named the H-Cube, combines endogenous hydrogen generation from the electrolysis of water with a continuous flow-through system. The system makes significant advances over current batch hydrogenation reactors in terms of safety, reaction validation efficiency, and rates of reaction. The hydrogenation process is described along with a detailed description of the device's main parts. The reduction of a series of functional groups, varying in difficulty up to 70 degrees C and 70 bar are also described. The paper concludes with the integration of the device into an automated liquid handler followed by the reduction of a nitro compound in a high throughput manner. The system is fully automated and can conduct 5 reactions in the time it takes to perform and workup one reaction manually on a standard batch reactor.

Catalysis↗

High-throughput siRNA-based functional target validation.

The drug discovery process pursued by major pharmaceutical companies for many years starts with target identification followed by high-throughput screening (HTS) with the goal of identifying lead compounds. To accomplish this goal, significant resources are invested into automation of the screening process or HTS. Robotic systems capable of handling thousands of data points per day are implemented across the pharmaceutical sector. Many of these systems are amenable to handling cell-based screening protocols as well. On the other hand, as companies strive to develop innovative products based on novel mechanisms of action(s), one of the current bottlenecks of the industry is the target validation process. Traditionally, bioinformatics and HTS groups operate separately at different stages of the drug discovery process. The authors describe the convergence and integration of HTS and bioinformatics to perform high-throughput target functional identification and validation. As an example of this approach, they initiated a project with a functional cell-based screen for a biological process of interest using libraries of small interfering RNA (siRNA) molecules. In this protocol, siRNAs function as potent gene-specific inhibitors. siRNA-mediated knockdown of the target genes is confirmed by TaqMan analysis, and genes with impacts on biological functions of interest are selected for further analysis. Once the genes are confirmed and further validated, they may be used for HTS to yield lead compounds.

Base Sequence↗

Multidimensional capillary array liquid chromatography and matrix-assisted laser desorption/ionization tandem mass spectrometry for high-throughput proteomic analysis.

A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.

Chromatography, Liquid↗

High-throughput RNAi screening by time-lapse imaging of live human cells.

RNA interference (RNAi) is a powerful tool to study gene function in cultured cells. Transfected cell microarrays in principle allow high-throughput phenotypic analysis after gene knockdown by microscopy. But bottlenecks in imaging and data analysis have limited such high-content screens to endpoint assays in fixed cells and determination of global parameters such as viability. Here we have overcome these limitations and developed an automated platform for high-content RNAi screening by time-lapse fluorescence microscopy of live HeLa cells expressing histone-GFP to report on chromosome segregation and structure. We automated all steps, including printing transfection-ready small interfering RNA (siRNA) microarrays, fluorescence imaging and computational phenotyping of digital images, in a high-throughput workflow. We validated this method in a pilot screen assaying cell division and delivered a sensitive, time-resolved phenoprint for each of the 49 endogenous genes we suppressed. This modular platform is scalable and makes the power of time-lapse microscopy available for genome-wide RNAi screens.

Automation↗

Preselection of shotgun clones by oligonucleotide fingerprinting: an efficient and high throughput strategy to reduce redundancy in large-scale sequencing projects.

Large-scale genomic sequencing projects generally rely on random sequencing of shotgun clones, followed by different gap closing strategies. To reduce the overall effort and cost of those projects and to accelerate the sequencing throughput, we have developed an efficient, high throughput oligonucleotide fingerprinting protocol to select optimal shotgun clone sets prior to sequencing. Both computer simulations and experimental results, obtained from five PAC-derived shotgun libraries spanning 535 kb of the 17p11.2 region of the human genome, demonstrate that at least a 2-fold reduction in the number of sequence reads required to sequence an individual genomic clone (cosmid, PAC, etc.) can be achieved. Treatment of clone contigs with significant clone overlaps will allow an even greater reduction.

Chromosomes, Human, Pair 17↗

High-throughput and multiplexed protein array technology: protein-DNA and protein-protein interactions.

Miniaturized protein arrays address protein interactions with various types of molecules in a high-throughput and multiplexed fashion. This review focuses on achievements in the analysis of protein-DNA and protein-protein interactions. The technological feasibility of protein arrays depends on the different factors that enable the arrayed proteins to recognize molecular partners and on the specificity of the interactions involved. Proteome-scale studies of molecular interactions require high-throughput approaches for both the production and purification of functionally active proteins. Various solutions have been proposed to avoid non-specific protein interactions on array supports and to monitor low-abundance molecules. The data accumulated indicate that this emerging technology is perfectly suited to resolve networks of protein interactions involved in complex physiological and pathological phenomena in different organisms and to develop sensitive tools for biomedical applications.

Cell-Free System↗

Small molecules with antimicrobial activity against E. coli and P. aeruginosa identified by high-throughput screening.

BACKGROUND AND PURPOSE: New antimicrobials are needed because of the emergence of organisms that are resistant to available antimicrobials. The purpose of this study was to evaluate a high-throughput screening approach to identify antibacterials against two common disease-causing bacteria, and to determine the frequency, novelty, and potency of compounds with antibacterial activity. EXPERIMENTAL APPROACH: A high-throughput, turbidometric assay of bacterial growth in a 96-well plate format was used to screen a diverse collection of 150,000 small molecules for antibacterial activity against E. coli and P. aeruginosa. The statistical Z'-factor for the assay was > or = 0.7. KEY RESULTS: Screening for inhibition of E. coli growth gave a 'hit' rate (> 60% inhibition at 12.5 microM) of 0.025%, which was more than 5-fold reduced for P. aeruginosa. The most potent antibacterials (EC50 < 0.5 microM) were of the nitrofuran class followed by naphthalimide, salicylanilide, bipyridinium and quinoazolinediamine chemical classes. Screening of > 250 analogs of the most potent antibacterial classes established structure-activity data sets. CONCLUSIONS AND IMPLICATIONS: Our results validate and demonstrate the utility of a growth-based phenotype screen for rapid identification of small-molecule antibacterials. The favourable efficacy and structure-activity data for several of the antibacterial classes suggests their potential development for clinical use.

Anti-Bacterial Agents↗