Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Increased DNA microarray hybridization specificity using sscDNA targets.

BACKGROUND: The most widely used amplification method for microarray analysis of gene expression uses T7 RNA polymerase-driven in vitro transcription (IVT) to produce complementary RNA (cRNA) that can be hybridized to arrays. However, multiple rounds of amplification are required when assaying very small amounts of starting RNA. Moreover, certain cRNA-DNA mismatches are more stable than the analogous cDNA-DNA mismatches and this might increase non-specific hybridization. We sought to determine whether a recently developed linear isothermal amplification method (ribo-SPIA) that produces single stranded cDNA would offer advantages over traditional IVT-based methods for microarray-based analyses of transcript expression. RESULTS: A single round of ribo-SPIA amplification produced sufficient sscDNA for hybridizations when as little as 5 ng of starting total RNA was used. Comparisons of probe set signal intensities obtained from replicate amplifications showed consistently high correlations (r = 0.99). We compared gene expression in two different human RNA samples using ribo-SPIA. Compared with one round IVT, ribo-SPIA had a larger dynamic range and correlated better with quantitative PCR results even though we used 1000-fold less starting RNA. The improved dynamic range was associated with decreases in hybridization to mismatch control probes. CONCLUSION: The use of amplified sscDNA may offer substantial advantages over IVT-based amplification methods, especially when very limited amounts of starting RNA are available. The use of sscDNA targets instead of cRNA targets appears to improve hybridization specificity.

Animals↗

Logarithmic amplifiers.

Logarithmic amplifiers (log amps), which produce an output signal proportional to the logarithm of the input signal, are widely used in cytometry for measurements of parameters that vary over a wide dynamic range, e.g., cell surface immunofluorescence. Existing log amp circuits all deviate to some extent from ideal performance with respect to dynamic range and fidelity to the logarithmic curve; accuracy in quantitative analysis using log amps therefore requires that log amps be individually calibrated. However, accuracy and precision may be limited by photon statistics and system noise when very low level input signals are encountered.

Amplifiers, Electronic↗

Effects of stimulation rate, mode and level on modulation detection by cochlear implant users.

In cochlear implant (CI) patients, temporal processing is often poorest at low listening levels, making perception difficult for low-amplitude temporal cues that are important for consonant recognition and/or speech perception in noise. It remains unclear how speech processor parameters such as stimulation rate and stimulation mode may affect temporal processing, especially at low listening levels. The present study investigated the effects of these parameters on modulation detection by six CI users. Modulation detection thresholds (MDTs) were measured as functions of stimulation rate, mode, and level. Results show that for all stimulation rate and mode conditions, modulation sensitivity was poorest at quiet listening levels, consistent with results from previous studies. MDTs were better with the lower stimulation rate, especially for quiet-to-medium listening levels. Stimulation mode had no significant effect on MDTs. These results suggest that, although high stimulation rates may better encode temporal information and widen the electrode dynamic range, CI patients may not be able to access these enhanced temporal cues, especially at the lower portions of the dynamic range. Lower stimulation rates may provide better recognition of weak acoustic envelope information.

Acoustic Stimulation↗

Physical origin of peak tailing on C18-bonded silica in reversed-phase liquid chromatography.

Single component isotherm data of caffeine and phenol were acquired on two different stationary phases for RPLC, using a methanol/water solution (25%, v/v, methanol) as the mobile phase. The columns were the non-endcapped Waters Resolve-C18, and the Waters XTerra MS C18. Both columns exhibit similar C18 -chain densities (2.45 and 2.50 micromol/m2) and differ essentially by the nature of the underivatized solid support (a conventional, highly polar silica made from water glass, hence containing metal impurities, versus a silica-methylsilane hybrid surface with a lower density of less acidic free silanols). Thirty-two adsorption data points were acquired by FA, for caffeine, between 10(-3) and 24 g/l, a dynamic range of 24,000. Twenty-eigth adsorption data points were acquired for phenol, from 0.025 to 75 g/l, a dynamic range of 3000. The expectation-maximization procedure was used to derive the affinity energy distribution (AED) from the raw FA data points, assuming a local Langmuir isotherm. For caffeine, the AEDs converge to a bimodal and a quadrimodal distribution on XTerra MS-C18 and Resolve-C18, respectively. The values of the saturation capacity (q(s,1) approximately equal to 0.80 mol/l and q(s,2) approximately equal to 0.10 mol/l) and the adsorption constant (b1 approximately equal to 3.11/mol and b2 approximately equal to 29.1 l/mol) measured on the two columns for the lowest two energy modes 1 and 2, are comparable. These data are consistent with those previously measured on an endcapped Kromasil-C18 in a 30/70 (v/v), methanol/water solution (q(s,1) = 0.9 mol/l and q(s,2) = 0.10 mol/l, b1 = 2.4 l/mol and b2 = 16.1 l/mol). The presence of two higher energy modes on the Waters Resolve-C18 column (q(s,3) approximately equal to 0.013 mol/l and q(s,4) approximately equal to 2.6 10(-4) mol/l, b3 approximately equal to 252 l/mol and b4 = 13,200 l/mol) and the strong peak tailing of caffeine are explained by the existence of adsorption sites buried inside the C18-bonded layer. It is demonstrated that strong interactions between caffeine and the water protected bare silica surface cannot explain these high-energy sites because the retention of caffeine on an underivatized Resolve silica column is almost zero. Possible hydrogen-bond interactions between caffeine and the non-protected isolated silanol groups remaining after synthesis amidst the C18-chain network cannot explain these high energy interactions because, then, the smaller phenol molecule should exhibit similarly strong interactions with these isolated silanols on the same Resolve-C18 column and, yet, the consequences of such interactions are not observed. These sites are more consistent with the heterogeneity of the local structure of the C18-bonded layer. Regarding the adsorption of phenol, no matter whether the column is endcapped or not, its molecular interactions with the bare silica were negligible. For both columns, the best adsorption isotherm was the Bilangmuir model (with q(s,1) approximately equal to 2 and q(s,2) approximately equal to 0.67 mol/l, b1 0.61 and b2 approximately equal to 10.3 l/mol). These parameters are consistent with those measured previously on an endcapped Kromasil-C18 column under the same conditions (q(s,1) = 1.5 and q(s,2) = 0.71 mol/l, b1 = 1.4 l/mol and b2 = 11.3 l/mol). As for caffeine, the high-energy sites are definitely located within the C18-bonded layer, not on the bare surface of the adsorbent.

Chromatography, Liquid↗

Development of a monoclonal antibody-based enzyme-linked immunosorbent assay for the herbicide chlorimuron-ethyl.

Hybridomas secreting a monoclonal antibody (mAb) against the herbicide chlorimuron-ethyl (CE) were produced by fusing the mouse myeloma cell line (SP2/0) with splenocytes from a mouse immunized against the conjugate of the sulfonamide moiety of CE and bovine serum albumin (BSA). The mAb, designated 1F5C5A10, had very weak affinity with metsulfuron, ethametsulfuron, pyrazosulfuron, bensulfuron, and chlorsulfuron. Two mAb-based indirect competitive enzyme-linked immunosorbent assays (icELISA) were developed. A conventional icELISA (icELISA-I) showed a concentration of half-maximum inhibition (IC(50)) of 11.6 ng/mL with a dynamic range of 1.6-84 ng/mL. A simplified icELISA (icELISA-II) had an IC(50) of 28.7 ng/mL and a dynamic range of 2.2-372 ng/mL. The two assays were tested on spiked water and soil samples. CE (1-500 ng/mL) fortified in water samples could be analyzed directly without any sample preparation by both immunoassays with an average recovery between 74 and 114%. icELISA-II, but not icELISA-I, was able to accurately analyze the herbicide residues in the crude soil extracts with recoveries between 99 and 129% without obvious matrix effects due to its lesser amount of sample used. In contrast to icELISA-I, icELISA-II is more convenient, whereas it consumes more reagents of coating antigen and goat anti-mouse IgG-peroxidase.

Animals↗

[Prognostic indications within the scope of the selection of cochlear implant patients].

The common selection criteria for cochlear implant patients do not allow any prognostic indication on the final result. On the other hand, some postoperative data (threshold, TDL, dynamic range, duration of deafness) corresponds clearly with the results, some of them also correspond with the preoperative data. Preoperative TDL, dynamic range as well as duration of deafness can therefore be used as suitable prognostic indicators.

Auditory Threshold↗

Preliminary study of a metal/a-Se-based portal detector.

A feasibility study has been performed on metal/amorphous selenium detectors for megavoltage portal imaging. The metal plates of the detectors were positioned facing the incident 6 MV and Co-60 photon spectra. The detectors consist of various thicknesses (0.15 mm, 0.30 mm, and 0.50 mm) of amorphous selenium (a-Se) deposited on metal plates of varying thicknesses: aluminum (2.0 mm), copper (1.0 mm and 1.5 mm), stainless steel (0.9 mm), or glass (1.1 mm). The detectors were charged prior to irradiation by corona methods, and the portal images were subsequently digitized after irradiation with a noncontact electrostatic probe. The sensitivity of the detectors to dose, electric field across the a-Se layer, metal plate type and a-Se thickness, was studied. The electrostatic voltage remaining on the a-Se layer was found, both theoretically and experimentally, to exhibit a cubic relationship with respect to dose. An increase in electric field increases the sensitivity (gradient of the a-Se surface voltage vs dose curve) and dynamic range of the resultant image. An increase in a-Se thickness, however, although also increasing the sensitivity, decreases the dynamic range. The metal plate types and thicknesses within the range studied do not have a significant effect on detector sensitivity. Image quality and contrast resolution of the detector were evaluated with a contrast-detail phantom and compared to commercially available film based and electronic portal imaging devices. Image quality of the metal/a-Se detector as a function of dose was studied by discharging the a-Se to various fractions of its initial charge, and as expected, increases with dose due to a decrease in quantum noise. Contrast-detail images obtained by metal/a-Se detectors are superior to those obtained at higher dose levels by other commercial systems.

Biophysical Phenomena↗

On the development and testing of a guided ultrasonic wave array for structural integrity monitoring.

The prototype of a guided ultrasonic wave array for the structural integrity monitoring of large, plate-like structures has been designed, built, and tested. The development of suitably small transducers for the excitation and measurement of the first antisymmetric Lamb wave mode Ao is described. The array design consists of a ring of 32 transducers, permanently bonded to the structure with a protective membrane, in a compact housing with the necessary multiplexing electronics. Using a phased addition algorithm with dispersion compensation and deconvolution in the wavenumber domain, a good dynamic range can be achieved with a limited number of transducers. Limitations in the transducer design and manufacture restricted the overall dynamic range achieved to 27 dB. Laboratory measurements for a steel plate containing various defects have been performed. The results for standard defects are compared to theoretical predictions and the sensitivity of the array device for defect detection has been established. Simulated corrosion pitting and a defect cut with an angle grinder simulating general corrosion were detected.

Journal Article↗

Reduction of the nonspecific binding of a target antibody and of its enzyme-labeled detection probe enabling electrochemical immunoassay of an antibody through the 7 pg/ml-100 ng/mL (40 fM-400 pM) range.

We describe a simple, potentially low-cost, amperometric, enzyme-amplified, sandwich-type immunoassay, monitoring IgG at a concentration as low as approximately 7 pg/mL with a dynamic range of 10(4). The assay utilizes a screen-printed carbon electrode on which a redox hydrogel and avidin are co-electrodeposited. To neutralize nonspecifically binding positively charged microdomains of the avidin, two polyanions, poly(acrylic acid-co-maleic acid) and poly(acrylic acid), are applied. These polyanions bind to the film not only electrostatically but also by Michael addition reaction to cysteine, lysine, or arginine functions of the avidin. The electrode is then made specific for the analyte, for which rabbit IgG was chosen, by conjugating the film-bound avidin to biotin-labeled anti-rabbit IgG. After exposure to the tested solution and capture of rabbit IgG, the sandwich is completed by conjugation of horseradish-peroxidase (HRP)-labeled anti-rabbit IgG. Electrical contact between the HRP and the electrode-bound hydrogel results in the formation of an electrocatalyst for the electroreduction of H2O2 to water. The application of the poly(acrylic acid-co-maleic acid) and the poly(acrylic acid) reduces the nonspecific adsorption-associated noise, lowers the detection limit from 3 ng/mL (approximately 20 pM analyte antibody concentration) to approximately 7 pg/mL (approximately 40 fM analyte antibody concentration), and also expands the dynamic range to 10(4).

Adsorption↗

Simultaneous determination of BNP7787 and its metabolite mesna in plasma and tissue by micro-HPLC with a dual electrochemical detector.

Sensitive, accurate, and precise assays are described to determine BNP7787 (disodium 2,2'-dithio-bis-ethane sulfonate) and its metabolite mesna (sodium 2-mercaptoethane sulfonate) simultaneously in plasma and tissue by micro-high-performance liquid chromatography (HPLC) with dual electrochemical detection. After separation of BNP7787 and mesna by micro-HPLC, the disulfide BNP7787 was reduced to mesna by a reactor cell with a glassy carbon working electrode (-1.6 V versus Hy-REF). At the second electrode, which consisted of a gold wall-jet electrode, the mesna generated from BNP7787 and the mesna already present in the samples were detected (+0.85 V versus Ag/AgCl). The lower limit of quantification (LLQ) of both compounds was 3 microM in plasma and 20 nmol/g in tissue. The dynamic range of the assay in plasma was 3-120 microM for mesna and 15-1200 microM for BNP7787. In tissue, the dynamic range was 20-2000 nmol/g for both compounds. The recovery of mesna from plasma and tissue ranged from 61.4 to 90.5% and 82.7 to 90.2%, respectively, and seemed to be concentration dependent. The recovery of BNP7787 from plasma and tissue was complete (i.e., 101.5 and 96.4%, respectively). The within- and between-day accuracy and precision for the plasma and tissue assay were within 14 and 7%, respectively. The utility of the assay was shown by determination of the stability of mesna and BNP7787 in a kidney sample of a rat and by analysis of plasma samples obtained from a patient receiving 18.4 g/m(2) BNP7787 as a 15-min intravenous infusion.

Animals↗

Temporally patterned sound pulse trains affect intensity and frequency sensitivity of inferior collicular neurons of the big brown bat, Eptesicus fuscus.

This study examined the effect of temporally patterned pulse trains on intensity and frequency sensitivity of inferior collicular neurons of the big brown bat, Eptesicus fuscus. Intensity sensitivity of inferior collicular neurons was expressed by the dynamic range and slope of rate-intensity functions. Inferior collicular neurons with non-monotonic rate-intensity functions have smaller dynamic ranges and larger slopes than neurons with monotonic or saturated rate-intensity functions. Intensity sensitivity of all inferior collicular neurons improved by increasing the number of non-monotonic rate-intensity functions when the pulse repetition rate of pulse trains increased from 10 to 30 pulses per second. Intensity sensitivity of 43% inferior collicular neurons further improved when the pulse repetition rate of pulse trains increased still from 30 to 90 pulses per second. Frequency sensitivity of inferior collicular neurons was expressed by the Q10, Q20, and Q30 values of threshold frequency tuning curves and bandwidths of isointensity frequency tuning curves. Threshold frequency tuning curves of all inferior collicular neurons were V-shape and mirror-images of their counterpart isointensity frequency tuning curves. The Q10, Q20, and Q30 values of threshold frequency tuning curves of all inferior collicular neurons progressively increased and bandwidths of isointensity frequency tuning curves decreased with increasing pulse repetition rate in temporally patterned pulse trains. Biological relevance of these findings to bat echolocation is discussed.

Animals↗

LPS-induced cytokine production in the monocytic cell line THP-1 determined by multiple quantitative competitive PCR (QC-PCR).

BACKGROUND: Quantifying cytokines on the protein level can be problematic because of low concentrations or degradation during sample handling. Aiming towards finding a simple method by which to quantify cytokines on the mRNA level, we combined existing and established molecular biology techniques. Based on the principle of quantitative competitive RT-PCR with a DNA-competitor, IL-1beta, IL-6, IL-12alpha and the housekeeping enzyme GAPDH are measured at levels down to 200 copies of mRNA. METHODS: As a source of mRNA, the total RNA from 4 samples of 5 x 10(6) THP-1 cells stimulated with LPS (1 microg/ml for 24 h) was isolated. For competitors, we constructed sequences similar to the target sequences, but with deletion or insertion of 10-15% of the target length. For validating this method, we performed first strand synthesis on different days using different amounts of RNA (1-4 microg) isolated from the same pool of cells. Quantitative competitive PCR was accomplished using different amounts of cDNA (0.125-4 microL). Using IL-1beta as an example, the assay was validated for a dynamic range of 5-300 x 10(3) copies. RESULTS: A linear correlation was found between output and amount of RNA for cDNA synthesis, signifying that the final result of the analysis was linearly related to the amount of RNA or cDNA when operating within the range 1-4 microg (RNA isolation). CONCLUSION: The quantitative, competitive RT-PCR produces highly reproducible results within a 60-fold dynamic range.

Cell Line↗

The representation of pure tones and noise in a model of cochlear nucleus neurons.

The limited dynamic range of the majority of auditory-nerve fibers represents a difficulty in accounting for normal hearing capabilities over the known psychoacoustic intensity range. The presence of noise is an additional complication because it will tend to saturate these fibers, thereby considerably reducing their dynamic range, i.e., the range of mean firing rates. In this study, simulations involving a model of auditory nerve and cochlear nucleus neurons were conducted using pure-tone stimuli in the presence of noise. The main focus is on the role of inhibition in regulating the activity of cells, improving their capability to represent signals in background noise. This concerns in particular those inhibitory neurons that receive input from a wide range of auditory-nerve fibers and respond with an onset chopper pattern. A detailed model of stellate cells is used. It allows several parameters such as the number, location, and strength of inputs to be manipulated. The fist part of this paper presents the model and its responses to pure-tone and noise stimuli presented separately. The model's capacity to generalize to tone/noise combinations is then tested. Responses to these stimuli are found to be qualitatively similar to neurophysiological findings. Model neurons exhibit appropriate shifts in their rate-level functions and their responses are inhibited or suppressed by tones outside their characteristic frequency. The model stellate cell is also found to display many of the temporal patterns reported in electrophysiological studies as a result of appropriate settings of certain parameters. Therefore, the model is sufficient to account for a larger number of findings and should serve as a basis for predicting responses to novel stimuli, or as a building block for modeling larger networks.

Audiometry, Pure-Tone↗

Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: measurement, precision, and RNA stability.

Eleven laboratories evaluated the use of dried blood and plasma spots for quantitation of human immunodeficiency virus (HIV) RNA by two commercially available RNA assays, the Roche Amplicor HIV-1 Monitor and the bioMerieux NucliSens HIV-1 QT assays. The recovery of HIV RNA was linear over a dynamic range extending from 4,000 to 500,000 HIV type 1 RNA copies/ml. The Monitor assay appeared to have a broader dynamic range and seemed more sensitive at lower concentrations. However, the NucliSens assay gave more consistent results and could be performed without modification of the kit. HIV RNA was stable in dried whole blood or plasma stored at room temperature or at -70 degrees C for up to 1 year. Dried blood and dried plasma spots can be used as an easy and inexpensive means for the collection and storage of specimens under field conditions for the diagnosis of HIV infection and the monitoring of antiretroviral therapy.

Antiviral Agents↗

Role of hyperpolarization-activated conductances in the lateral superior olive: a modeling study.

This modeling study examines the possible functional roles of two hyperpolarization-activated conductances in lateral superior olive (LSO) principal neurons. Inputs of these LSO neurons are transformed into an output, which provides a firing-rate code for a certain interaural sound intensity difference (IID) range. Recent experimental studies have found pharmacological evidence for the presence of both the Gh conductance as well as the inwardly rectifying outward GKIR conductance in the LSO. We addressed the question of how these conductances influence the dynamic range (IID versus firing rate). We used computer simulations of both a point-neuron model and a two-compartmental model to investigate this issue, and to determine the role of these conductances in setting the dynamic range of these neurons. The width of the dynamic regime, the frequency-current (f-I) function, first-spike latency, subthreshold oscillations and the interplay between the two hyperpolarization activated conductances are discussed in detail. The in vivo non-monotonic IID-firing rate function in a subpopulation of LSO neurons is in good correspondence with our simulation predictions. Two compartmental model simulation results suggest segregation of Gh and GKIR conductances on different compartments, as this spatial configuration could explain certain experimental results.

Action Potentials↗

Increased proteome coverage for quantitative peptide abundance measurements based upon high performance separations and DREAMS FTICR mass spectrometry.

A primary challenge in proteome measurements is to be able to detect, identify, and quantify the extremely complex mixtures of proteins. The relative abundances of interest span at least six orders of magnitude for mammalian proteomes, and this constitutes an intractable challenge for high throughput proteome studies. We have recently described a new approach, Dynamic Range Enhancement Applied to Mass Spectrometry (DREAMS), which is based upon the selective ejection of the most abundant species to expand the dynamic range of Fourier transform ion cyclotron resonanace (FTICR) measurements. The basis of our approach is on-the-fly data-dependent selective ejection of highly abundant species, followed by prolonged accumulation of remaining low-abundance species in a quadrupole external to the FTICR ion trap. Here we report the initial implementation of this approach with high efficiency capillary reverse phase LC separations and high magnetic field electrospray ionization FTICR mass spectrometry for obtaining enhanced coverage in quantitative measurements for mammalian proteomes. We describe the analysis of a sample derived from a tryptic digest of proteins from mouse B16 cells cultured in both natural isotopic abundance and 15N-labeled media. The FTICR mass spectrometric analysis allows the assignment of peptide pairs (corresponding to the two distinctive versions of each peptide), and thus provides the basis for quantiative measurements when one of the two proteomes in the mixture is perturbed or altered in some fashion. We show that implementation of the DREAMS approach allows assignment of approximately 80% more peptide pairs, thus providing quantitative information for approximately 18,000 peptide pairs in a single analysis.

Animals↗

Jejunal afferent nerve sensitivity in wild-type and TRPV1 knockout mice.

The aim of this study was to investigate the contribution of the TRPV1 receptor to jejunal afferent sensitivity in the murine intestine. Multiunit activity was recorded in vitro from mesenteric afferents supplying segments of mouse jejunum taken from wild-type (WT) and TRPV1 knockout (TRPV1(-/-)) animals. In WT preparations, ramp distension of the gut (up to 60 mmHg) produced biphasic changes in afferent activity so the pressure-response curve had an initial rapid increase in afferent discharge followed by a second phase of slower increase in activity. Afferent response to distension was significantly lower in TRPV1(-/-) than in WT mice. Single-unit analysis revealed three functional types of afferent fibres: (1) low-threshold fibres (2) wide dynamic range fibres and (3) high-threshold fibres. There was a marked downward shift of the pressure-response curve for wide dynamic range fibres in the TRPV1(-/-) mice as compared to the WT controls. The afferent response to intraluminal hydrochloric acid (20 mM) was also attenuated in the TRPV1(-/-) mice. In contrast, the response to bath application of bradykinin (1 microm, 3 ml) was not significantly different between the two groups. The TRPV1 antagonist capsazepine (10 microm) significantly attenuated the nerve responses to distension, intraluminal acid and bradykinin, as well as the spontaneous discharge in WT mice. The WT jejunal afferents responded to capsaicin with rapid increases in afferent activity, whereas TRPV1(-/-) afferents were not at all sensitive to capsaicin. Previous evidence indicates that TRPV1 is not mechanosensitive, so the results of the present study suggest that activation of TRPV1 may sensitize small intestinal afferent neurones.

Action Potentials↗

Real-time monitoring and verification of in vivo high dose rate brachytherapy using a pinhole camera.

We investigated a pinhole imaging system for independent in vivo monitoring and verification of high dose rate (HDR) brachytherapy treatment. The system consists of a high-resolution pinhole collimator, an x-ray fluoroscope, and a standard radiographic screen-film combination. Autofluoroscopy provides real-time images of the in vivo Ir-192 HDR source for monitoring the source location and movement, whereas autoradiography generates a permanent record of source positions on film. Dual-pinhole autoradiographs render stereo-shifted source images that can be used to reconstruct the source dwell positions in three dimensions. The dynamic range and spatial resolution of the system were studied with a polystyrene phantom using a range of source strengths and dwell times. For the range of source activity used in HDR brachytherapy, a 0.5 mm diameter pinhole produced sharp fluoroscopic images of the source within the dynamic range of the fluoroscope. With a source-to-film distance of 35 cm and a 400 speed screen-film combination, the same pinhole yielded well recognizable images of a 281.2 GBq (7.60 Ci) Ir-192 source for dwell times in the typical clinical range of 2 to 400 s. This 0.5 mm diameter pinhole could clearly resolve source positions separated by lateral displacements as small as 1 mm. Using a simple reconstruction algorithm, dwell positions in a phantom were derived from stereo-shifted dual-pinhole images and compared to the known positions. The agreement was better than 1 mm. A preliminary study of a patient undergoing HDR treatment for cervical cancer suggests that the imaging method is clinically feasible. Based on these studies we believe that the pinhole imaging method is capable of providing independent and reliable real-time monitoring and verification for HDR brachytherapy.

Biophysical Phenomena↗