Effects of low-density lipoproteins on blood coagulation and fibrinolytic activity.

In vitro experiments showed that copper-oxidized low-density lipoproteins activate factors of the prothrombin complex in the whole blood and inhibit fibrin generation in both blood and plasma. Moreover, oxidized low-density lipoproteins inhibit fibrinolysis and impair the structure of fibrin clot, which results in hypercoagulation.

Blood Coagulation↗

Hemostatic studies of ex situ hepatic surgery.

Ex situ hepatic surgery, in which a diseased liver is resected from outside the body, was first reported in 1988. This study investigates the hemostatic changes occurring during such surgery in two cases. During the anhepatic period of more than 5 hours, veno-venous bypass without heparin was performed. The tests included platelet count, prothrombin activity (PT), partial thromboplastin time (PTT), fibrinogen (Fbg), factor II (F.II), factor V (F.V), and thromboelastography (TEG). Three to 4 hours after entering the anhepatic phase, marked fibrinolysis and a fall in the values of PT, Fbg and F.V. were observed. Every parameter temporarily deteriorated immediately after revascularization of the graft, however, all returned to almost normal values within 1-2 hours after hepatic reperfusion except for F.V and platelets. In conclusion, the coagulopathy during ex situ hepatic surgery is caused by the marked fibrinolysis and depletion of hemostatic factors which develop 3-4 hours after the onset of the anhepatic phase.

Adult↗

The effect of enflurane and fentanyl anaesthesia on human platelet aggregation in vivo.

In 30 patients undergoing major operations, and anaesthetized with either nitrous oxide, oxygen and enflurane, or nitrous oxide, oxygen and fentanyl, there was no significant alteration in platelet aggregation induced by either adenosine diphosphate or collagen. The absence of any significant effect on platelet function was confirmed by an unchanging thromboelastogram pattern during the study.

Adenosine Diphosphate↗

Perioperative thromboelastography and sonoclot analysis in morbidly obese patients.

PURPOSE: To investigate perioperative coagulation in morbidly obese (MO) patients with the thromboelastograph (TEG) and Sonoclot analyzer. METHODS: Twenty-six consecutive morbidly obese and 26 consecutive lean patients presenting for elective surgery were enrolled in this prospective, observational study. Blood was sampled for TEG and Sonoclot analysis immediately after anaesthetic induction and at the end of surgery in the MO group, and immediately after anaesthetic induction in the lean group. The R and K times, alpha angle, maximum amplitude and percentage fibrinolysis at 30 and 60 min were recorded from the TEG. The Sonoclot ACT, initial clot rate, peak amplitude and time to peak amplitude were recorded from the Sonoclot. RESULTS: The TEG in the MO group demonstrated decreased R and K times (8.6 +/- 4.8 vs 11.7 +/- 3.9 mm, and 2.8 +/- 1.2 vs 3.5 +/- 0.9 mm respectively (P < 0.05)), and increased alpha angle (73.7 +/- 6.0 vs 66.7 +/- 6.0 degrees, P < 0.05) and maximum amplitude (72.0 +/- 5.4 vs 67.9 +/- 4.4 mm, P < 0.05), without change in fibrinolysis. Sonoclot variables in the MO group included increased clot rate (37.5 +/- 11.5 vs 23.9 +/- 7.7%, P < 0.05) and decreased time to peak impedance (11.7 +/- 5.0 vs 17.5 +/- 7.2 min, P < 0.05), without change in Sonoclot ACT or peak signature impedance. CONCLUSION: The MO group demonstrated accelerated fibrin formation, fibrinogen-platelet interaction, and platelet function compared with lean controls but no difference in fibrinolysis. Viscoelastic measures of coagulation may be useful in MO patients, who are at increased risk of thromboembolic events.

Adult↗

The usefulness of celite-activated thromboelastography for evaluation of fibrinolysis.

PURPOSE: Although thromboelastography is useful for measuring both coagulability and fibrinolysis, it takes about two hours to measure all parameters including fibrinolytic rate. The present study aimed to investigate the usefulness of celite-activated thromboelastography (TEGc) to evaluate fibrinolytic status in non-cardiac surgery. METHODS: Whole blood samples were obtained from 30 patients for non-cardiac surgery, and used for measurements of both native TEG (TEGn) and TEGc. The final concentration of 1% (w/v) celite was used for TEGc. RESULTS: Time for measurement of the fibrinolytic rate (FR) of TEGc in patients (56.7 +/- 4.0 min) was less than half that of FR of TEGn (123.3 +/- 15.6 min) (P < 0.05), suggesting a more rapid assessment of fibrinolytic status. A linear relationship was observed between FR values of TEGc and those of TEGn (r = 0.93, P < 0.0001), suggesting the usefulness of the fibrinolytic parameter of TEGc. CONCLUSION: TEGc is a useful technique for a more rapid assessment of fibrinolytic status.

Adult↗

[Reproducibility and interchangeability of the Thromboelastograph, Sonoclot and Hemochron activated coagulation time in cardiac surgery].

PURPOSE: Despite their common use in cardiac surgery, few studies have evaluated the reproducibility of the Thromboelastograph (TEG), of the Sonoclot (SCT), and of the activated coagulation time with celite (ACT-C) or kaolin (ACT-K) measured with the Hemochron, in clinical conditions of on-site monitoring of hemostasis. This study determined the reproducibility of those measurements, and evaluated the ability of various devices to substitute for the ACT-C. METHODS: Blood samples collected from 20 volunteers and 21 patients undergoing myocardial revascularization were analyzed in the two channels of the TEG, in two SCT and four Hemochron analyzers. The overall of TEG and SCT coagulation profiles were analyzed by a computerized TEG and an experienced observer respectively. The variation rate (V%) was calculated for each variable. The ability of ACT-K and SCT to substitute for ACT-C under different clinical conditions was evaluated. RESULTS: ACT-C and ACT-K V% ranged between 5.6% and 10.8% and between 6.7% and 12.4% respectively. TEG and SCT V% ranged between 3.1% and 9.5% and between 5.8% and 33.6% respectively, according to different conditions and parameters. In volunteers and non-heparinized patients, the ACT-C and ACT-K were interchangeable. No other test can substitute for the ACT-C when patients are heparinized during cardiopulmonary bypass (CPB). CONCLUSIONS: In the clinical conditions of use, on-site hemostasis monitoring devices providing the most reproducible measurements are, in decreasing order, the TEG, the Hemochron and the SCT. In heparinized patients and during CPB, results from different tests are not interchangeable, stressing the importance of establishing appropriate instrument-specific values for monitoring anticoagulation during cardiac surgery.

Adult↗

Magnesium therapy improves thromboelastographic findings before liver transplantation: a preliminary study.

PURPOSE: Patients undergoing liver transplantation may be predisposed to hypomagnesemia and present a bleeding tendency. There are evidences suggesting that magnesium is a crucial constituent of the blood coagulation cascade and has a pro-coagulant activity. The aim of this study was to investigate the effect of magnesium therapy on thromboelastography (TEG) in patients undergoing liver transplantation. METHODS: 27 patients scheduled for liver transplantation were enrolled. 1.5 g of magnesium sulfate, diluted in normal saline, were infused to all patients over five minutes in the operating room, before skin incision. The TEG findings immediately before and ten minutes after the magnesium infusion were compared. RESULTS: The TEG findings showed general hypocoagulability before magnesium therapy. The K time and coagulation times (r+k) were shortened significantly from 641.6 +/- 505.9 (mean +/- SD) to 464.6 +/- 387.7 sec and from 1664.7 +/- 772.5 to 1362.2 +/- 487.1 sec respectively (P < 0.05); the maximal amplitude, and TEG index showed significant increases from 38.5 +/- 13.5 to 45.3 +/- 12.2 mm and from -3.4 +/- 2.6 to -1.9 +/- 1.8 respectively after magnesium therapy (P < 0.01). R time, alpha angle and LY60 were not different after magnesium therapy. CONCLUSION: Magnesium therapy significantly improved TEG findings suggestive of a general hypocoagulable state towards normal in patients about to receive liver transplantation.

Anesthesia↗