Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MIRRORS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Optical tests of nanoengineered liquid mirrors.

We describe a new technology for the fabrication of inexpensive high-quality mirrors. We begin by chemically producing a large number of metallic nanoparticles coated with organic ligands. The partides are then spread on a liquid substrate where they self-assemble to give optical quality reflective surfaces. Since liquid surface can be modified by a variety of means (e.g., rotation, electromagnetic fields), this opens the possibility of making a new class of versatile and inexpensive optical elements that can have complex shapes and that can be modified within short time scales. Interferommetric measurements show optical quality surfaces. We have obtained reflectivity curves that show 80% peak reflectivities. We are confident that we can improve the reflectivity curves because theoretical models predict higher values. We expect nanoengineered liquid mirrors to be useful for scientific and engineering applications. The technology is interesting for large optics, such as large rotating parabolic mirrors, because of its low cost. Furthermore, because the surfaces of of ferrofluids can be shaped with magnetic fields, one can generate complex, time-varying surfaces that are difficult to make with conventional techniques.

Journal Article↗

Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers.

Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37 degrees, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm x 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm x 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

Animals↗

Production and performance of multilayer-coated conical x-ray mirrors.

A method of fabricating replica figured x-ray optics with integral multilayer coatings is presented. With the intact electroforming multilayer process (IEMP) technique, we sputter multilayers onto a reusable superpolished mandrel, electroform nickel over the multilayers, and remove the multilayer-coated nickel shell intact from the mandrel. This approach offers advantages over more traditional, original, and segmented-replica fabrication techniques, including low cost; compatibility with a wide range of mirror designs, diameters, and focal lengths; simple integration with multilayer sputtering processes; and the ability to produce complete shells of revolution. The fabrication of W/Si multilayer-coated 10-cm-diameter conical x-ray mirrors is described, as are reflectivity measurements at 10 and 30 keV. The measured reflectivity of the IEMP multilayers at the 10-keV primary Bragg peak was 17%. Measurements of multiple points on the cone showed multilayer uniformity to within a few percent around the mirror.

Journal Article↗

Control and alignment of segmented-mirror telescopes: matrices, modes, and error propagation.

Starting from the successful Keck telescope design, we construct and analyze the control matrix for the active control system of the primary mirror of a generalized segmented-mirror telescope, with up to 1000 segments and including an alternative sensor geometry to the one used at Keck. In particular we examine the noise propagation of the matrix and its consequences for both seeing-limited and diffraction-limited observations. The associated problem of optical alignment of such a primary mirror is also analyzed in terms of the distinct but related matrices that govern this latter problem.

Journal Article↗

Cryogenic far-infrared laser absorptivity measurements of the Herschel Space Observatory telescope mirror coatings.

Far-infrared laser calorimetry was used to measure the absorptivity, and thus the emissivity, of aluminum-coated silicon carbide mirror samples produced during the coating qualification run of the Herschel Space Observatory telescope to be launched by the European Space Agency in 2007. The samples were measured at 77 K to simulate the operating temperature of the telescope in its planned orbit about the second Lagrangian point, L2, of the Earth-Sun system. Together, the telescope's equilibrium temperature in space and the emissivity of the mirror surfaces will determine the far-infrared-submillimeter background and thus the sensitivity of two of the three astronomical instruments aboard the observatory if stray-light levels can be kept low relative to the mirror emission. Absorptivities of both clean and dust-contaminated samples were measured at 70, 118, 184, and 496 microm. Theoretical fits to the data predict absorptivities of 0.2-0.4% for the clean sample and 0.2-0.8% for the dusty sample, over the spectral range of the Herschel Space Observatory instruments.

Journal Article↗

Active optics and modified-Rumsey wide-field telescopes: MINITRUST demonstrators with vase- and tulip-form mirrors.

Wide-field astronomy requires the development of larger aperture telescopes. The optical properties of a three-mirror modified-Rumsey design provide significant advantages when compared to other telescope designs: (i) at any wavelength, the design has a flat field and is anastigmatic; (ii) the system is extremely compact, i.e., it is almost four times shorter than a Schmidt. Compared to the equally compact flat-field Ritchey-Chrétien with a doublet-lens corrector, as developed for the Sloan digital sky survey-and which requires the polishing of six optical surfaces-the proposed modified-Rumsey design requires only a two-surface polishing and provides a better imaging quality. All the mirrors are spheroids of the hyperboloid type. Starting from the classical Rumsey design, it is shown that the use of all eight available free parameters allows the simultaneous aspherization of the primary and tertiary mirrors by active optics methods from a single deformable substrate. The continuity conditions between the primary and the tertiary hyperbolizations are achieved by an intermediate narrow ring of constant thickness that is not optically used. After the polishing of a double vase form in a spherical shape, the primary-tertiary hyperbolizations are achieved by in situ stressing. The tulip-form secondary is hyperbolized by stress polishing. Other active optics alternatives are possible for a space telescope. The modified-Rumsey design is of interest for developing large space- and ground-based survey telescopes in UV, visible, or IR ranges, such as currently demonstrated with the construction of identical telescopes MINITRUST-1 and -2, f/5-2 degrees field of view. Double-pass optical tests show diffraction-limited images.

Journal Article↗

Picosecond soliton transmission by use of concatenated gain-distributed nonlinear amplifying fiber loop mirrors.

Stable picosecond soliton transmission is demonstrated numerically by use of concatenated gain-distributed nonlinear amplifying fiber loop mirrors (NALMs). We show that, as compared with previous soliton transmission schemes that use conventional NALMs or nonlinear optical loop mirror and amplifier combinations, the present scheme permits a significant increase of loop-mirror (amplifier) spacing. The broad switching window of the present device and the high-quality pulses switched from it provide a reasonable stability range for soliton transmission. We also show that a soliton self-frequency shift can be suppressed by the gain-dispersion effect in the amplifying fiber loop and that soliton-soliton interactions can be partially reduced by using lowly dispersive transmission fibers.

Journal Article↗

Fiber ring laser with a feedback mirror.

We describe the spectral and power features of a ytterbium-doped double-clad photonic crystal fiber laser that is operated in a ring configuration with an external mirror that feeds back only one of its two output beams. We compare the operation of the laser with and without an external feedback mirror. We find that the feedback mirror reduces significantly the spectral and power fluctuations. It is also responsible for an interesting spectral phenomenon: The laser frequency is drifting periodically over 9 nm at a rate of 2 nm/s from a short wavelength to a longer wavelength and vice versa.

Journal Article↗

Design, fabrication, and analysis of chirped multilayer mirrors for reflection of extreme-ultraviolet attosecond pulses.

Chirped Mo/Si multilayer coatings have been designed, fabricated, and characterized for use in extreme-ultraviolet attosecond experiments. By numerically simulating the reflection of the attosecond pulse from a multilayer mirror during the optimization procedure based on a genetic algorithm, we obtain optimized layer designs. We show that normal incidence chirped multilayer mirrors capable of reflecting pulses of approximately 100 attoseconds (as) duration can be designed by enhancing the reflectivity bandwidth and optimizing the phase-shift behavior. The chirped multilayer coatings have been fabricated by electron-beam evaporation in an ultrahigh vacuum in combination with ion-beam polishing of the interfaces and in situ reflectivity measurement for layer thickness control. To analyze the aperiodic layer structure by hard-x-ray reflectometry, we have developed an automatic fitting procedure that allows us to determine the individual layer thicknesses with an error of less than 0.05 nm. The fabricated chirped mirror may be used for production of 150-160 as pulses.

Journal Article↗

Folding mirror schlieren diffraction interferometer.

We demonstrate the use of a mirror as a viewing diaphragm to generate a built-in diffracted reference beam in schlieren diffraction interferometry (SDI). The use of a mirror edge as a diffracting element instead of a conventional knife edge considerably enhances the contrast of the schlieren pattern, and it is shown to be equal to that of a phase knife edge. This increase in contrast is due to the fact that the otherwise unutilized diffracted beam in SDI is recombined in the described folding mirror geometry.

Journal Article↗

Cavity with a deformable mirror for tailoring the shape of the eigenmode.

We demonstrate an optical cavity that supports an eigenmode with a flattop spatial profile--a profile that has been proposed for the cavities in the Advanced Laser Interferometer Gravitational Wave Observatory, the second-generation laser interferometric gravitational wave observatory--because it provides better averaging of the spatially dependent displacement noise on the surface of the mirror than a Gaussian beam. We describe the deformable mirror that we fabricated to tailor the shape of the eigenmode of the cavity and show that this cavity is a factor of 2 more sensitive to misalignments than a comparable cavity with spherical mirrors supporting an eigenmode with a Gaussian profile.

Journal Article↗

Focusing diffractive cylindrical mirrors: rigorous evaluation of various design methods.

The performance characteristics of focusing diffractive mirrors designed with various methods are evaluated by using the rigorous boundary element method. Quantitative results are presented for (1) conventional-zero-thickness mirror designs, (2) alternative-zero-thickness designs that incorporate an off-axis correction factor and (3) finite-thickness designs. For TM polarization, the mirrors designed by using the alternative-zero-thickness method perform considerably worse than those designed by using the conventional-zero-thickness method, which contradicts predictions made in an earlier paper.

Journal Article↗

Application of the parallel generalized projection algorithm to the control of two finite-resolution deformable mirrors for scintillation compensation.

A modification of the parallel generalized projection algorithm is presented that allows for the use of projections in a weighted norm. Convergence properties of the modified algorithm, denoted the weighted parallel generalized projection algorithm, are developed. The weighted parallel generalized projection algorithm is applied to the control of two finite-resolution deformable mirrors to compensate for both the amplitude and the phase fluctuations that result from propagation through a turbulent medium. Numerical results are shown that indicate that a two-deformable-mirror system can provide improved performance over that of a single-deformable-mirror system.

Journal Article↗

Phasing of a two-channel continuous-wave master oscillator-power amplifier by use of a fiber phase-conjugate mirror.

Phasing of two-channel cw master-oscillator-power-amplifier beams by using a phase-conjugate mirror has been demonstrated for the first time to the best of our knowledge. Phasing was achieved with two fiber amplifiers in conjunction with a single-frequency Nd:YAG master oscillator by using a fiber phase-conjugate mirror in a double-pass geometry. The successful demonstration of phasing of two cw amplifier beams with a fiber phase-conjugate mirror greatly enhances the prospects for phasing of multiple laser amplifiers without complex servo-loop control systems.

Journal Article↗

Doppler optical coherence tomography with a micro-electro-mechanical membrane mirror for high-speed dynamic focus tracking.

An elliptical microelectromechanical system (MEMS) membrane mirror is electrostatically actuated to dynamically adjust the optical beam focus and track the axial scanning of the coherence gate in a Doppler optical coherence tomography (DOCT) system at 8 kHz. The MEMS mirror is designed to maintain a constant numerical aperture of approximately 0.13 and a spot size of approximately 6.7 microm over an imaging depth of 1mm in water, which improves imaging performance in resolving microspheres in gel samples and Doppler shift estimation precision in a flow phantom. The mirror's small size (1.4 mm x 1 mm) will allow integration with endoscopic MEMS-DOCT for in vivo applications.

Computer Systems↗

Mirror neurons, procedural learning, and the positive new experience: a developmental systems self psychology approach.

In summary, we are impressed with the existence of a mirror neuron system in the prefrontal cortex that serves as part of a complex neural network, including afferent and efferent connections to the limbic system, in particular the amygdala, in addition to the premotor and motor cortex. We think it is possible to arrive at an integration that postulates the mirror neuron system and its many types of associated multimodal neurons as contributing significantly to implicit procedural learning, a process that underlies a range of complex nonconscious, unconscious, preconscious and conscious cognitive activities, from playing musical instruments to character formation and traumatic configurations. This type of brain circuitry may establish an external coherence with developmental systems self psychology which implies that positive new experience is meliorative and that the intentional revival of old-old traumatic relational configurations might enhance maladaptive procedural patterns that would lead to the opposite of the intended beneficial change. When analysts revive traumatic transference patterns for the purpose of clarification and interpretation, they may fail to appreciate that such traumatic transference patterns make interpretation ineffective because, as we have stated above, the patient lacks self-reflection under such traumatic conditions. The continued plasticity and immediacy of the mirror neuron system can contribute to positive new experiences that promote the formation of new, adaptive, implicit-procedural patterns. Perhaps this broadened repertoire in the patient of ways of understanding interrelational events through the psychoanalytic process allows the less adaptive patterns ultimately to become vestigial and the newer, more adaptive patterns to emerge as dominant. Finally, as we have stated, we believe that the intentional transferential revival of trauma (i.e., the old-old relational configuration) may not contribute to therapeutic benefit. In contrast, the revival of trauma in the old-new configuration (i.e., in the presence of a helpful other who can reduce anxiety and foster eventual positive new experience) can be beneficial, as trauma research has demonstrated. This is the process that promotes new implicit-procedural learning, new-new relational configurations, and a richer understanding of the self narrative.

Brain↗

Positive emotions preferentially engage an auditory-motor "mirror" system.

Social interaction relies on the ability to react to communication signals. Although cortical sensory-motor "mirror" networks are thought to play a key role in visual aspects of primate communication, evidence for a similar generic role for auditory-motor interaction in primate nonverbal communication is lacking. We demonstrate that a network of human premotor cortical regions activated during facial movement is also involved in auditory processing of affective nonverbal vocalizations. Within this auditory-motor mirror network, distinct functional subsystems respond preferentially to emotional valence and arousal properties of heard vocalizations. Positive emotional valence enhanced activation in a left posterior inferior frontal region involved in representation of prototypic actions, whereas increasing arousal enhanced activation in presupplementary motor area cortex involved in higher-order motor control. Our findings demonstrate that listening to nonverbal vocalizations can automatically engage preparation of responsive orofacial gestures, an effect that is greatest for positive-valence and high-arousal emotions. The automatic engagement of responsive orofacial gestures by emotional vocalizations suggests that auditory-motor interactions provide a fundamental mechanism for mirroring the emotional states of others during primate social behavior. Motor facilitation by positive vocal emotions suggests a basic neural mechanism for establishing cohesive bonds within primate social groups.

Acoustic Stimulation↗

Investigations of a mirror-image transfer effect in pigeons.

In two separate experiments, pigeons trained binocularly to peck a key on which an oblique line (e.g., 60 degrees counter-clockwise rotation from horizontal) was projected yielded bi-modal angularity generalization gradients in extinction, with peaks of responding at both the training stimulus and its mirror image (in this case 120 degrees ). This mirror-image transfer effect may be analogous to an "octave effect" in auditory generalization, but Mello's finding of a mirror-image reversal transfer effect following monocular training in pigeons suggests an alternative interpretation.

Animals↗