Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Resolution of biparametric mixtures using bead injection spectroscopic flow-through renewable surface sensors.

A new, sensitive and simple bead injection spectroscopy-flow injection analysis (BIS-FIA) sensor with spectrophotometric detection, using a commercially available flow-cell, is described to the determination of biparametric mixtures. As an analytical model, the metallic mixture Cu(II) and Zn(II) has been chosen. The flow-cell (Hellma 138-OS) is filled by injecting in the flow system 300 microl of a homogeneous bead suspension of an anion exchanger gel (Sephadex QAE A-25) previously loaded with the chromogenic reagent 2-carboxyl-2-hydroxy-5-sulfoformazylbenzene (Zincon). A sequential reaction of Cu(II) and Zn(II) with Zincon to form two complexes is performed on the bead sensing support and the absorbance is monitored at 627 nm, after two successive injections from the mixture solution. The sample containing these metal ions is injected into the first carrier (deionized water, pH 5.9), and Cu(II) selectively reacts with Zincon on the beads, developing the analytical signal. Then, 600 microl of 2 M HCl is injected to decompose the complex, and the carrier solution is changed. At pH 11 (second carrier) both Cu(II) and Zn(II) react with the chromogenic reagent, the absorbance now corresponding to both analytes. The eluent is again injected to descompose both complexes. After three analyses the sensing bead surface is not regenerated. Then, beads are automatically discarded from the flow cell by reversal of the flow, and instantaneously transported out of the system. So the procedure exploits the combination of the concepts of flow-through renewable sensors with bead injection spectroscopy. Using a sample volume of 1000 microl, the calibration graph for Cu(II) is linear over the range 0.05 to 1 microg ml(-1) and for Zn(II) from 0.1 to 1.8 microg ml(-1) in the presence of each other. RSDs (%) lower than 5% are obtained for both analytes. The sensor is satisfactorily applied to individual determination or mixture resolution in waters, pharmaceuticals, soils and human hair samples.

Azo Compounds↗

Stopped-in-loop flow analysis of trace vanadium in water.

The new concept of stopped-in-loop flow analysis (SIL-FA) is proposed, and an SIL-FA method for the catalytic determination of vanadium is demonstrated. In an SIL format, a sample solution merges with reagent(s), and the well-mixed solution is loaded into a loop. The solution in the loop is separated by a six-way switching valve from the main stream. While the reaction proceeds in the stationary loop, the SIL-FA system does not need to establish a baseline continuously. This leads to a reduction in reagent consumption and waste generation compared with traditional flow injection analysis.

Calibration↗

Ethanol biosensors based on alcohol oxidase.

The detection and quantification of ethanol with high sensitivity, selectivity and accuracy is required in many different areas. A variety of methods and strategies have been reported for the determination of this analyte including gas chromatography, liquid chromatography, refractometry and spectrophotometry, among other. The use of the enzyme alcohol oxidase (AOX) on the analysis of ethanol in complex samples allows a considerable enhancement in specificity. This paper reviews the state of the art on ethanol determination based on AOX sensors, using either electrochemical electrodes or immobilised enzyme reactors. Almost all AOX-based ethanol sensors developed so far are based on the monitoring of O2 consumption or H2O2 formation. This has been mostly achieved using amperometric electrodes set at appropriate potentials namely, -600 mV for O2 monitoring or +600 mV for H2O2 monitoring. Mediated and non-mediated bienzymatic systems have also been assembled using AOX coupled to horseradish peroxidase (HRP). Different types of electrodes have been proposed for the detection of ethanol, namely, membrane electrode, carbon paste electrodes, screen-printed electrodes and self-assembled monolayers. Another approach to work with this sensitive enzyme is to use high amounts of AOX in order to create an enzyme reservoir, a strategy which can be implemented using immobilised enzyme reactors. These reactors can be combined with a colorimetric detection in a flow-injection analysis system or with electrochemical transducers.

Alcohol Oxidoreductases↗

Kinetic control of reagent dissolution for the flow injection determination of iron at trace levels.

A novel methodology for the determination of iron at the ppb level by spectrophotometric flow injection analysis is described. The method is based on the control of the flow dissolution of the colorimetric reagent 1,10-phenanthroline. This is achieved by means of the minimization of the area of contact between the carrier and the solid reagent, thus allowing the use of the fairly soluble organic compound without affecting the reactor lifetime. The reagent is melted inside an acrylic column (3.0 x 0.5 cm id) in such a way that a hollow space is left in the center after cooling. This new design improves some aspects of the performance of the classical solid-phase reactors as no problems related to the increase in the backpressure of the system are evidenced. Furthermore, the total reagent loading of the column is increased as no inert support is needed. A comparison between the performance of this novel methodology and that of the conventional packed reactor was performed and several advantages were observed: the use of higher flow rates, an increase in the reactor lifetime and a decrease in reagent consumption. A mathematical model to fit the concentration profiles of the dissolved reagent as a function of the residence time of the sample within the column is presented. The application of this strategy to the determination of Fe(II) improves the figures of merit in comparison to those obtained with a single-line homogeneous system: the limit of detection is 2 microg Fe L(-1) (3s) and the sensitivity is similar to that of the batch procedure. Results obtained for the determination of iron in natural waters are also presented.

Flow Injection Analysis↗

Temporal shifting: a hidden key to the skewed peak puzzle.

The recorder-provided peak position for flow-type chemical instruments has been verified mathematically as being comprised of a "spatially-non-existent" shift, which is generated due to the relativity in accounting for the detection at a fixed point. This shift, denoted as Phi, can be approximated by Phi approximately 0.5micro(t)2, where micro(t) is the temporal expanding coefficient of the system given. For flow injection analysis, the shift is correlated to a longitudinal dispersion coefficient D and the flow speed u, i.e., Phi approximately D/u2. For linear chromatography, it is correlated to a dynamic partition ratio k'' and a scaling factor f of the column used, i.e., Phi approximately 0.5k''f. In combination, the temporal shift can be expressed as Phi approximately 0.5k''f+D(k''+1)2/u2. Although the shift may be small in scale, it provides a clue to decipher the basic parameters from a recorded peak. Under a linear isotherm, this parameter can be estimated readily from an experimental peak following a very simple procedure.

Algorithms↗

Dispersion-convolution model for simulating peaks in a flow injection system.

A dispersion-convolution model is proposed for simulating peak shapes in a single-line flow injection system. It is based on the assumption that an injected sample plug is expanded due to a "bulk" dispersion mechanism along the length coordinate, and that after traveling over a distance or a period of time, the sample zone will develop into a Gaussian-like distribution. This spatial pattern is further transformed to a temporal coordinate by a convolution process, and finally a temporal peak image is generated. The feasibility of the proposed model has been examined by experiments with various coil lengths, sample sizes and pumping rates. An empirical dispersion coefficient (D*) can be estimated by using the observed peak position, height and area (tp*, h* and At*) from a recorder. An empirical temporal shift (Phi*) can be further approximated by Phi*=D*/u2, which becomes an important parameter in the restoration of experimental peaks. Also, the dispersion coefficient can be expressed as a second-order polynomial function of the pumping rate Q, for which D*(Q)=delta0+delta1Q+delta2Q2. The optimal dispersion occurs at a pumping rate of Qopt=sqrt[delta0/delta2]. This explains the interesting "Nike-swoosh" relationship between the peak height and pumping rate. The excellent coherence of theoretical and experimental peak shapes confirms that the temporal distortion effect is the dominating reason to explain the peak asymmetry in flow injection analysis.

Algorithms↗

Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters.

In this work a microflow structure, suitable for micro-FIA (micro flow injection analysis), will be described, evaluated and applied to real samples. Microchannels, the detector flow cell and input/output ports have been micromachined in silicon and sealed with anodically bonded Pyrex glass. The channels are defined by etching approximately 200 microm depth in silicon using a dry reactive ion etching (RIE) process. Optical windows integrated in the chip structure allow simple absorbance/transmission measurements to be made. The optical measurements were made using an LED as emitter (lambda=525 nm) and a photodiode as a detector. A Visual-Basic program has been developed to control an automatic burette, three-way solenoid valves and the data acquisition system. The micro-FIA for nitrite determination using the Griess-Ilosvay reaction has been implemented for the on-line monitoring of wastewater treatment plants (WWTPs). The multicommutation concept has been applied in order to enhance the mixing process inside the microsystem. Tandem streams of reagent and sample were generated and evaluated at different commutation frequencies. Two optimal frequencies, 400/200 ms and 150/450 ms, were found to be the most suitable ones. The first commutation ratio gave rise to wide linear working range (0-250 ppm), in spite of a high detection limit (0.35 ppm) and a low sensitivity (0.0041+/-0.0004 AU ppm-1). With the second ratio, the working linear range was smaller (0-50 ppm) but the detection limit (0.17 ppm) and the sensitivity (0.0091+/-0.0003 AU ppm-1) improved remarkably. Finally, real samples with a high nitrite concentration (0-1500 ppm) coming from a study of kinetic inhibition in the nitrification process at a WWTP has been analysed with the proposed micro-FIA system. The obtained results have allowed the corroboration of the model of inhibition by the nitrite ion with great exactitude.

Autoanalysis↗

Development of solid-phase chemiluminescence immunoassays for digoxin comparing flow injection and sequential injection techniques.

The development of a competitive solid-phase immunoassay for digoxin making use of the acridinium chemiluminescence system is described. Two different instrumental approaches are compared. One is based on a continuous flow system using a peristaltic flow injection analysis pump; the other uses a new sequential injection technique. In both systems a flow cell, consisting of transparent PTFE tubing packed with immobilized antibodies, acts as an immunoreactor. The entire assay, including both the immunoreaction and the chemiluminescence reaction, takes place in this immunoreactor cell. Compared with the flow injection technique, the sequential injection mode showed higher precision, ranging from 2.16 to 5.5% RSD depending on concentration. The total assay time, including regeneration, is less than 8 min with the sequential injection technique. The detection limit for both techniques is in the low femtomole range.

Cardiotonic Agents↗

A compactly integrated flow cell with a chemiluminescent FIA system for determining lactate concentration in serum.

We have fabricated an integrated flow cell as a total microanalysis system (microTAS). This flow cell (size, 15 x 20 mm; total inner volume, 12.2 microL) was designed for a rational analyzing system of lactate determination for serum. This cell was made by micromachining techniques and consisted of two hollows of a lactate oxidase (LOD) reactor and a mixing cell, a spiral groove, and three penetrated holes. To form the reactor and capillary, these patterns, etched on a silicon wafer, were attached to a glass plate by the anodic bonding method. A photodiode was put under part of the spiral capillary. The compactly accumulated devices were integrated into a flow injection analysis (FIA) system. In the flow cell, lactate was catalyzed to pyruvate and hydrogen peroxide at the LOD reactor; subsequently, hydrogen peroxide reacted with the luminol-ferricyanic reagent at the mixing cell. The resulting chemiluminescent light was detected by the photodiode. Using the miniaturized flow cell, the sample volume for one measurement was greatly reduced to 0.2 microL. The response to lactate was obtained within 30 s and was linear between 0.5 and 5.0 mM (4.5 and 45 mg/dL) lactate with excellent correlative variances of 3.2% (average of three measurements at 5.0 mM). For practical application, the lactate concentration in control human serum was determined using this system. The results showed a good correlation coefficient (r = 0.979) with the results obtained by the spectrophotometric reference method. No difference in sera (normal or pathological) was found. Consequently, this integrated flow cell shows potential as a clinical device for lactate determination in serum. In this article, the effect of the design on the chemiluminescent FIA system is also described.

Enzymes, Immobilized↗

Validation of a diffusive sampler for NO2.

A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.

Air Pollution↗

Determination of aluminum in beverages by automated non-segmented continuous flow analysis with fluorescent detection of the lumogallion complex.

A method for the automated determination of aluminum in a variety of beverages is described. The method utilizes lumogallion as a complexing agent in a buffer solution. The system is very similar to flow-injection analysis (FIA), however, the tubing id is larger than that typically used in FIA. Therefore, the system is best described as non-segmented continuous flow analysis using fluorescence spectroscopy detection. The method is extremely simple, requiring virtually no sample preparation and only one reagent. The instrument detection limit for aluminum is 0.012 microgram ml-1 and calibration is linear to 3 micrograms ml-1. Results from a variety of beverage matrices are discussed and compared with the frequently used 8-hydroxyquinolone method utilizing a chloroform extraction and fluorescence spectroscopy detection.

Aluminum↗

A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors.

A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 microm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few microl of an appropriate enzyme solution, an amperometric enzyme sensor results. As the dialysis tubing is impermeable for large molecular species such as enzymes, this approach does not require any immobilization chemistry, and as a consequence the enzyme is present in its natural free form. Based on this principle, amperometric sensors for lactate, glucose, and glutamate were formed by filling cavities, precision machined in Perspex, with buffered solutions containing respectively, lactate-, glucose-, and glutamate-oxidase. All sensors showed a large linear range (0-35 mM for glucose, 0-3 mM for lactate, and 0-5 mM for glutamate) covering the complete physiological range. The lower detection limit was in the order of 15-50 microM. Applicability in flow injection analysis systems is demonstrated.

Biosensing Techniques↗

Chemically prepared silver electrode for determination of N-acetyl-L-cysteine by flow-injection potentiometry.

This paper describes the use of the silver electrode by means of chemical pretreatment of the electrode surface with mercuric(II) chloride solution and potassium iodide solution in flow injection analysis (FIA). The electrode is used as a potentiometric sensor for the indirect determination of NAC in a carrier stream containing iodine. A one-channel flow system that consists of a peristaltic pump, injection valve, a silver wire electrode and a saturated calomel reference electrode (SCE) was used. Some typical FIA parameters such as flow rate, tube length and composition of the carrier stream were varied. The electrode is further characterised by a constant linear response within the concentration range for NAC between 4.0 x 10(-6) and 1.0 x 10(-3) M at the slope of 60.6 +/- 1.0 mV/p(NAC). Some pharmaceutical products containing NAC were also tested. These results can be compared to the results obtained by the direct potentiometric titrations with silver nitrate and are also in good agreement with values declared by pharmaceutical manufacturers.

Acetylcysteine↗

Flow injection immunoassay for carcinoembryonic antigen combined with time-resolved fluorometric detection.

Time-resolved fluorescence has been developed for immunoassay to obtain higher sensitivity than usual immunoassays. In this paper, a simple, sensitive and specific method was developed for immunoassay of serum carcinoembryonic antigen (CEA) by combining time-resolved fluoroimmunoassay (TRFIA) and flow injection analysis. Based on a sandwich immunoassay format, a monoclonal antibody immobilized immunoaffinity column inserted in a flow system was used for immunoreactions. The cleaved solution was collected after the reaction between the immunocomplex in the immunoaffinity column and the enhancement solution that was used to cleave the Eu-labels from the immunocomplex, and then detected by time-resolved fluorescence. Serum CEA could be detected in the linear range from 2.5 to 100 ng/ml with a correlation coefficient of 0.997 and the detection limit of 1.0 ng/ml. Twenty human serum samples detected by this method were in good agreement with the results obtained by the electrochemiluminescence immunoassay. This method could be further developed for fast practical clinical detection of serum CEA levels.

Carcinoembryonic Antigen↗

A flow-through optosensing device with fluorimetric transduction for rapid and sensitive determination of dipyridamole in pharmaceuticals and human plasma.

A flow-through optosensor with fluorimetric transduction has been prepared for the sensitive and selective determination of dipyridamole in aqueous solutions and biological fluids. The method is based on a monochannel flow-injection analysis system using Sephadex QAE A-25 resin, placed into a Hellma 176-QS fluorimetric flow-through cell, as an active sorbing substrate. The native fluorescence of dipyridamole fixed on the solid sorbent is continuously monitored at wavelengths of 305 and 490 nm for excitation and emission, respectively. After obtaining the maximum fluorescence intensity, the eluent solution (KH(2)PO(4)/NaOH buffer solution, c(T)=0.05 mol l(-1), pH 6.0) is allowed to reach the flow cell, the analyte is removed, and the resin support is regenerated. When an NaOH (10(-4) mol l(-1))/NaCl (0.1 mol l(-1)) solution is used as carrier solution, at a flow-rate of 1.56 ml min(-1), the sensor responds linearly in the measuring range of 10-500 microg l(-1) with a detection limit of 0.94 microg l(-1) and a throughput of 22 samples per hour (300 microl of sample volume). The relative standard deviation for ten independent determinations (200 microg l(-1)) is less than 0.82%. The method was satisfactorily applied to the determination of dipyridamole in pharmaceutical preparations and human plasma.

Chemistry, Pharmaceutical↗

Application of fuzzy logic in multicomponent analysis by optodes.

Fuzzy logic can be a useful tool for the determination of substrate concentrations applying optode arrays in combination with flow injection analysis, UV-VIS spectroscopy and kinetics. The transient diffuse reflectance spectra in the visible wavelength region from four optodes were evaluated to carry out the simultaneous determination of artificial mixtures of ampicillin and penicillin. The discrimination of the samples was achieved by changing the composition of the receptor gel and working pH. Different algorithms of pre-processing were applied on the data to reduce the spectral information to a few analytic-specific variables. These variables were used to develop the fuzzy model. After calibration the model was validated by an independent test data set.

Ampicillin↗

On-line cation exchange for suppression of adduct formation in negative-ion electrospray mass spectrometry of nucleic acids.

One major difficulty in the analysis of nucleic acids by electrospray mass spectrometry is represented by the affinity of the polyanionic sugar-phosphate backbone for nonvolatile cations, especially ubiquitous sodium and potassium ions. A simple on-line sample preparation system comprising a microflow pumping system and 45 x 0.8-mm-i.d. microcolumns packed with weak or strong cation-exchange resins is described for the efficient removal of cations from nucleic acid samples. Samples were analyzed by flow injection analysis at a 3-5 microL/min flow of 10 mM triethylamine in 50% water-50% acetonitrile. After on-line desalting, mass spectra of oligonucleotides revealed no significant sodium adduct peaks. Moreover, signal-to-noise ratios were greatly enhanced compared to direct injection of the samples. Electrospray mass spectrometry with on-line sample preparation allowed accurate molecular mass determinations of picomole amounts of crude oligonucleotide preparations ranging in size from 8 to 80 nucleotides within a few minutes. The good linearity of the calibration plot (R2 = 0.9988) over at least 2 orders of magnitude and a relative standard deviation in peak areas of less than 9% permitted the sensitive quantitative measurement of oligonucleotides in a concentration range of 0.2-20 microM with selected-ion monitoring. Finally, the on-line sample preparation system was evaluated for the mass spectrometric analysis of complex oligonucleotide mixtures.

Cations↗

Progress in monitoring, modeling and control of bioprocesses during the last 20 years.

The paper gives a review on the recent development of bioprocess engineering. It includes monitoring of product formation processes by flow injection analysis, various types of chromatographic and spectroscopic methods as well as by biosensors. The evaluation of mycelial morphology and physiology by digital image analysis is discussed also. It deals with advanced control of indirectly evaluated process variables by means of state estimation/observer, with the use of structured and hybrid models, expert systems and pattern recognition for process optimization and gives a short report on the state of the art of metabolic flux analysis and metabolic engineering.

Biosensing Techniques↗