Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiac Catheterization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28Linked to original sources

Cholesterol embolism after cardiac catheterization mimicking infective endocarditis.

We present a 65-year-old man with rheumatic combined valvular heart disease showing persistent fever 3 weeks after diagnostic cardiac catheterization. Infective endocarditis was strongly suspected from the clinical course, however, serial blood cultures were negative. Transesophageal echocardiography, done to investigate vegetation, revealed multiple mobile plaques in the descending aorta. Administration of both steroid and simvastatin improved both symptoms and renal function. Cholesterol embolism should be considered to be one of the possible causes of low-grade fever after cardiac catheterization especially in patients with anticoagulation.

Aged↗

Contrast-induced nephrotoxicity in patients undergoing cardiac catheterization.

Contrast-induced nephrotoxicity (CIN) is a common concern among angiographers. The causes of CIN are not well understood and the identification and preparation of patients at risk are important. This report reviews the literature concerning the causes and identification of patients at risk and documents the studies that are available to improve the safety of cardiac catheterization and cardiac interventions by reducing the risk of CIN.

Acute Kidney Injury↗

Vascular injury following cardiac catheterization, coronary angiography, and coronary angioplasty.

All vascular injuries occurring at this hospital department over a 5-year period (1987-91) as a result of cardiac catheterization, coronary angiography, or coronary angioplasty (PTCA) and requiring transfusion, surgical consultation, or repair, are reviewed. Such complications may occur late and, to detect cases not apparent from the protocol accompanying every examination, a questionnaire was sent to all surgical clinics in the region asking for details of vascular surgical intervention after angiography. The present review of 4879 examinations disclosed 18 patients with 19 vascular injuries (0.39%); four of them were detected by the questionnaire. The types of injury were: pseudoaneurysm (12), thrombembolic episode (4), and excessive bleeding (3). Of the patients with a vascular complication 11 (61%) were receiving anticoagulation treatment, compared to 10% in the whole series; two others suffered from a coagulopathic state. Catheterization was difficult or severe atherosclerosis was present in three, inadvertent mobilization occurred in one, and unintentional puncture distal to the common femoral artery occurred in two patients. With the increasing use of invasive diagnostic and interventional procedures in cardiovascular diseases, knowledge of the type and frequency of possible complications is important, especially of those that may occur late. In the present study anticoagulation, coagulation disorders, and cardiac catheterization combined with brachial puncture and angiography all predisposed to a vascular complication.

Adult↗

Dexmedetomidine-ketamine and propofol-ketamine combinations for anesthesia in spontaneously breathing pediatric patients undergoing cardiac catheterization.

OBJECTIVE: The purpose of this study was to compare the effects of dexmedetomidine-ketamine and propofol-ketamine combinations on hemodynamics, sedation level, and the recovery period in pediatric patients undergoing cardiac catheterization. DESIGN: Prospective, randomized trial. SETTING: University hospital. PARTICIPANTS: Children (n = 44) undergoing cardiac catheterization. INTERVENTIONS: The dexmedetomidine plus ketamine group (group 1, n = 22) received an infusion over 10 minutes of 1 microg/kg of dexmedetomidine and ketamine, 1 mg/kg, as a bolus, for induction. The patients then received an infusion of 0.7 microg/kg/h of dexmedetomidine and 1 mg/kg/h of ketamine for maintenance. The propofol plus ketamine group (group 2, n = 22) received 1 mg/kg of propofol and 1 mg/kg of ketamine for induction. The patients received 100 microg/kg/min of propofol and 1 mg/kg/h of ketamine by infusion for maintenance. Additional doses of ketamine, 1 mg/kg, were administered when a patient showed discomfort in both groups. MEASUREMENTS AND MAIN RESULTS: Hemodynamic data, respiratory rate, bispectral index, and sedation scores were recorded after induction and every 15 minutes thereafter. The time to reach a Steward recovery score of 6 was recorded. The heart rate in group 1 was significantly lower (average 10-20 beats/min) than group 2 after induction and throughout the procedure. Ketamine consumption in group 1 was significantly more than in group 2 (2.03 mg/kg/h v 1.25 mg/kg/h) for maintenance (p < 0.01). The recovery time was also longer in group 1 than in group 2 (49.54 v 23.16 minutes, respectively; p < 0.01). CONCLUSIONS: The dexmedetomidine-ketamine combination was not superior to a propofol-ketamine combination because of insufficient sedation and analgesia and a longer recovery time.

Anesthesia Recovery Period↗

Carcinoid heart disease. Correlation of high serotonin levels with valvular abnormalities detected by cardiac catheterization and echocardiography.

BACKGROUND: Although serotonin has been postulated as an etiologic agent in the development of carcinoid heart disease, no direct evidence for different ambient serotonin levels in cardiac and noncardiac patients has been reported to date. METHODS AND RESULTS: The present study reviews our experience with 604 patients in the Duke Carcinoid Database. Nineteen patients with proven carcinoid heart disease (by cardiac catheterization and/or echocardiogram) were compared with the remaining 585 noncardiac patients in the database with regard to circulating serotonin and its principal metabolite, 5-hydroxyindole acetic acid (5-HIAA). No significant demographic differences existed between the cardiac and noncardiac groups; however, typical carcinoid syndrome symptoms (ie, flushing and diarrhea) were almost threefold more common in the cardiac group (P < .001). Compared with the noncardiac group, heart disease patients demonstrated strikingly higher (P < .0001) mean serum serotonin (9750 versus 4350 pmol/mL), plasma serotonin (1130 versus 426 pmol/mL), platelet serotonin (6240 versus 2700 pmol/mg protein), and urine 5-HIAA (219 versus 55.3 mg/24 h) levels. The spectrum of heart disease among the 19 patients showed a strong right-sided valvular predominance, with tricuspid regurgitation being the most common valvular dysfunction (92% by cardiac catheterization; 100% by echocardiogram). CONCLUSIONS: These data suggest that serotonin plays a major role in the pathogenesis of the cardiac plaque formation observed in carcinoid patients.

Carcinoid Heart Disease↗

Evaluation of calibration methods for size estimation in the pediatric cardiac catheterization laboratory.

Limited data are available on the accuracy of various calibration methods used to estimate the size of cardiovascular structures during interventional pediatric cardiac catheterizations. The aim of this study was to evaluate, in an experimental model, several of these commonly used calibration methods. Thoracic box models were constructed in 4 sizes to simulate average chest sizes of infants, children, adolescents, and adults. Four anatomic positions were studied: aortic valve in posteroanterior projection, pulmonary valve in lateral projection, and isthmus in posteroanterior and lateral projections. The following calibration methods were examined: (1) a 5Fr pigtail catheter or a 1-cm radio-opaque marker catheter, placed at the level of the anatomic structure, (2) a body surface marker in multiple positions, and (3) a 1 x 1-cm radio-opaque rectilinear grid placed either at the center of the thorax or in an anatomic position. Three independent observers made size estimations. The most accurate method for size estimation, in all anatomic positions and for all box sizes, was the 1-cm radio-opaque marker catheter (mean error </=4%). The surface marker was moderately accurate in the smallest box (mean error 3% to 6%), but had a mean error as high as 33% in the adult-sized box. The 5Fr pigtail angiographic catheter overestimated the size of the structure by 3% to 13% (mean 7%). Intra- and interobserver differences in size estimations were not statistically significant. Among the size calibration methods used during pediatric cardiac catheterizations, catheters with radio-opaque markers within the structure of interest were the most accurate. The use of surface markers in larger patients may introduce significant error, risking a potentially inadequate or adverse outcome from the intervention.

Adolescent↗

Practical value of echo Doppler evaluation of aortic and mitral stenosis: a comparative study with cardiac catheterization.

This retrospective analysis compares data derived by echocardiography and cardiac catheterization in the evaluation of aortic and mitral valve stenosis. Sixty-seven patients, aged 69 +/- 12 years, underwent 76 catheterization procedures. In all studies the Doppler recording was technically adequate. In 64 studies of patients with aortic stenosis, correlation was good between the gradient obtained at catheterization (peak 51 +/- 28 mm Hg, mean 48 +/- 24 mm Hg) and the Doppler gradient (peak 73 +/- 29 mm Hg, mean 41 +/- 17 mm Hg) (R = 0.78 peak, 0.77 mean). In 15 studies the aortic valve area, 0.8 +/- 0.2 cm2, calculated by the simplified continuity equation, correlated well with the catheterization valve area, 0.7 +/- 0.3 cm2, calculated by the Gorlin equation (R = 0.80). In 14 studies in mitral stenosis patients, the mean gradient at catheterization was 11 +/- 5 mm Hg compared to the Doppler gradient of 8 +/- 4 mm Hg (R = 0.58). The mitral valve area was 1.1 +/- 0.3 cm2 by the Gorlin equation and 1.2 +/- 0.3 cm2 by echo Doppler, using pressure half-time. When cardiac rhythm, the presence and severity of regurgitation, and the cardiac index were analyzed, none was shown to have demonstrable influence on the accuracy of the Doppler study. Doppler echocardiography can be used reliably to assess valvular stenosis in a clinical, noninvasive laboratory where routine tests are performed and interpreted by more than one individual.

Aged↗

Subacute bilateral coronary ostial stenoses following cardiac catheterization and PTCA.

Accelerated coronary ostial stenosis is an infrequent late complication of coronary artery catheter instrumentation during aortic valve surgery, PTCA, or coronary angiography. We report the first case of bilateral coronary artery ostial stenoses developing after cardiac catheterization and right coronary artery PTCA. In patients with worsening angina following cardiac catheterization or PTCA, accelerated ostial stenoses should not be over-looked in the differential diagnosis.

Angioplasty, Balloon, Coronary↗

Infective endocarditis following cardiac catheterization in infancy. A case report and review.

A 4.5-month-old infant with transposition of great vessels and large ventricular septal defect developed acute infective endocarditis following cardiac catheterization. Beta-hemolytic streptococcus was recovered from three blood cultures. The infant survived after 6 weeks intravenous antibiotic therapy. The occurrence of infective endocarditis following cardiac catheterization during infancy is briefly reviewed and discussed. The importance of distinguishing febrile episodes of infancy from infective endocarditis and the use of two-dimensional echocardiography for diagnosis is re-emphasized.

Cardiac Catheterization↗

Percutaneous translumbar cardiac catheterization and central venous line insertion: an alternative approach in children with congenital heart disease.

Children with congenital heart disease present major problems with venous access, eliminating conventional routes for cardiac catheterization. Although the transhepatic approach has recently gained popularity, we describe here an alternative approach using percutaneous translumbar approach for cardiac catheterization and/or in-dwelling central line insertion in three children with congenital heart disease. Diagnostic hemodynamic studies, transcatheter delivery of an intravascular stent for left pulmonary artery (LPA) stenosis, and chronic central venous line insertion were performed using this technique. Disadvantages include interventionalist's unfamiliarity with technique, awkward patient positioning, technically more difficult than transhepatic, and potential injury to kidney and bowel. Advantages include avoidance of vascular-rich hepatic parenchyma, thus reducing risk of hemorrhage; providing an alternative where transhepatic entry may be contraindicated; avoidance of bile duct, portal vein, and hepatic artery injury; and providing another alternative for not only transvenous, but also transarterial access that may be required for intravascular aortic stent delivery. The interventional radiologist should be utilized as a valuable resource to the cardiologist to help teach and supervise this technique in selected infants and children with limited vascular access.

Cardiac Catheterization↗

Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization.

BACKGROUND: Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. METHODS AND RESULTS: For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found (r=0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%. CONCLUSIONS: Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.

Cardiac Catheterization↗

Changes in carbon dioxide tension and oxygen saturation during deep sedation for paediatric cardiac catheterization.

The purpose of this observational study was to determine whether hypercarbia or oxygen desaturation occurred during our current regimens of deep sedation or general anaesthesia of infants and children undergoing cardiac catheterization. Data were gathered prospectively from 50 consecutive infants and children aged 4 months to 12 years undergoing cardiac catheterization. Several anaesthetists used the following regimens, which were not randomized: 1) propofol. 1.5-2.0 mg.kg-1 and fentanyl 1 microgram.kg-1 IV over 2 min for induction, followed by propofol infusion of 100-150 micrograms.kg-1.min-1; 2) fentanyl 2-3 micrograms.kg-1 and midazolam 0.1-0.2 mg.kg-1 IV over 10-15 min; 3) ketamine 8 mg.kg-1 IM, or 4) same as regimens 1 or 2, plus pancuronium, intubation and controlled ventilation. Regimens 1, 2, and 3 were associated with spontaneous ventilation through the natural airway. End-tidal carbon dioxide tension (PetCO2), SpO2, and respiratory rate were monitored for 60 min. The three regimens employing spontaneous ventilation through the natural airway were associated with both statistically and clinically significant increases in PetCO2 and decreases in SpO2. This raises the possibility that acute exacerbation of PAP and PVR may occur in pulmonary hypertensive patients. In contrast, PetCO2 and SpO2 did not change significantly from baseline in the controlled ventilation group.

Anesthesia, Intravenous↗

Combined axillary plexus block and basal sedation for cardiac catheterization in young children.

A technique for the management of cardiac catheterization in children is described which combines axillary plexus block with basal sedation. The technique offers a quiet still arm with pronounced vasodilatation, permitting the use of larger catheters than usual, making sampling easier, and giving undamped pressure records. These factors, together with the absence of venospasm, make catheterization of an arm vein in young chīldren a feasible proposition; in addition arterial sampling via the brachial artery may be performed without further inconvenience to the child.

Anesthesia, Conduction↗

Gadolinium as an alternative contrast agent during cardiac catheterization in patient with iodine-induced hyperthyroidism.

We report the first case of a male patient with iodine-induced hyperthyroidism and unstable angina pectoris in whom a diagnostic cardiac catheterization with gadolinium as contrast agent was chosen. The patient was hospitalized with an iodine-induced hyperthyroidism after angioplasty using an iodinated contrast agent. He presented with a continuous arrhythmia and unstable angina pectoris. A repeated cardiac catheterization using iodinated contrast agent was contraindicated. This case report shows that gadolinium is a useful alternative contrast agent for cardiac intervention in patients with iodine-induced hyperthyroidism.

Cardiac Catheterization↗

Transradial cardiac catheterization in elderly patients.

The safety and efficacy of transradial cardiac catheterization in elderly patients is unknown. This study examines procedure success rates for transradial catheterization in appropriately selected patients < 70 (n = 195) and >/= 70 (n = 83) years old. Elderly patients were less likely to be selected for the transradial approach (46% vs. 61%; P = 0.05). Although patients >/= 70 years old were more often female (39.7% vs. 24.1%; P = 0.008) and had a smaller body surface area (1.89 +/- 0.18 vs. 2.01 +/- 0.24 m2; P = 0. 001), procedure success rates did not differ (95.1% vs. 94.8%; P = NS). Procedure-related variables including procedure time (15.4 +/- 12.6 vs. 16.1 +/- 11.6 min; P = NS), amount of radiographic contrast (90.1 +/- 31.9 vs. 86.4 +/- 29.8 cc; P = NS), and number of catheters used (1.5 +/- 0.9 vs. 1.5 +/- 0.7; P = NS) were similar between groups. We conclude that transradial catheterization can be safely and effectively performed in selected elderly patients. Cathet. Cardiovasc. Intervent. 51:287-290, 2000.

Adult↗

Exposure reduction using yttrium filters in a cardiac catheterization unit.

This study measures the radiation exposure reduction during cardiac catheterization when using yttrium filtration. Measurements of entrance exposure to a phantom were taken during fluoroscopy and cineangiocardiography. Exposure reductions of as much as 54% were found with no apparent loss of image quality in routine procedures and little increase in tube loading.

Aluminum↗

Video networking of cardiac catheterization laboratories.

BACKGROUND: The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. METHODS: A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. RESULTS: A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. CONCLUSIONS: Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.

Angioplasty, Balloon, Coronary↗

Isolated splenic infarction following left cardiac catheterization: case report and a review of the literature.

A cardiac catheterization was performed in a 57-year-old man for post-infarction angina. A severe left flank pain developed following the angiography. Ultrasonography, computed tomography, and radionuclear scanning of the abdomen showed splenic infarction. An isolated cholesterol atheroembolism of spleen from disrupted atheromatous plaques so far has not been reported.

Cardiac Catheterization↗