Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “high throughput”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Pharmacology of recombinant human GABA(A) receptor subtypes measured using a novel pH-based high-throughput functional efficacy assay.

To facilitate the discovery of novel compounds that modulate human GABA(A) receptor function, we have developed a high throughput functional assay using a fluorescence imaging system. L(tk-) cells expressing combinations of human GABA(A) receptor subunits were incubated with the pH-sensitive dye 2',7'bis-(2-carboxyethyl)-5-(and 6)-carboxyfluorescein, then washed and placed in a 96-well real-time fluorescence plate reader. In buffer adjusted to pH 6.9 there was a robust and persisting acidification response to addition of GABA, which was antagonised by the GABA(A) receptor antagonist bicuculline. The concentration-response relationship for GABA was modulated by allosteric ligands, including benzodiazepine (BZ) site agonists and inverse agonists. The effects of BZ site ligands on the pH response to GABA for receptors containing alpha1beta3gamma2, alpha3beta3gamma2 or alpha5beta3gamma2 subunits were well correlated with results from electrophysiological studies on the same receptor subunit combinations expressed in Xenopus oocytes. Most modulatory compounds tested were found to be relatively unselective across the three subunit combinations tested; however, some showed subtype-dependent efficacy, such as diazepam, which had highest agonist effects on the alpha3beta3gamma2 subtype, substantial but lesser agonism on alpha1beta3gamma2 and still substantial but the least agonism on alpha5beta3gamma2. This indicates that the alpha subunit within the recombinant receptor expressed in L(tk-) cells can affect the efficacy of the response to some BZ compounds. Inhibitors of Na(+)/Cl(-) cotransport, anion/anion exchange and the gastric type of H(+)/K(+) ATPase potently inhibited GABA-evoked acidification, indicating that multiple transporters are involved in the GABA-evoked pH change. This novel fluorescence-based high throughput functional assay allows the rapid characterization of allosteric ligands acting on human GABA(A) receptors.

Animals↗

High-throughput three-dimensional gel electrophoresis for versatile utilities: a stacked slice-gel system for separation and reactions (4SR).

A novel high-throughput system, called the stacked slice-gel system for separation and reactions (4SR), was developed for the analysis of DNA/RNA and protein/peptide. The system provides a novel three-dimensional gel electrophoresis approach that exploits the property of stacked slice gels. It allows multiple samples simultaneously to react as well as to be separated, offering a two-dimensional (mxn) sample loading system. For this purpose, high-throughput multi-micro vessels (MMVs) containing variable numbers of wells (100 wells in this paper) have been used, which are made of 25 mm square-size polyacrylamide gels. Furthermore, after electrophoretic separation, a slice gel containing a desired sample can be easily removed and proceeded to the next step. Different biological reactions as well as successive separation of products were effectively carried out dealing with DNA/RNA and protein/peptide. It shows that this system has a diversity of potentials to be developed.

DNA↗

Phospho-specific recognition by 14-3-3 proteins and antibodies monitored by a high throughput label-free optical biosensor.

Label-free detection of molecular interactions has considerable potential in facilitating assay development. When combined with high throughput capability, it may be applied to small molecule screens for drug candidates. Phosphorylation is a key posttranslational process that confers diverse regulation in biological systems involving specific protein-protein interactions recognizing the phosphorylated motifs. Using a resonant waveguide grating biosensor, the Epic mark System, we have developed a generic assay to quantitatively measure phospho-specific interactions between a trafficking signal-phosphorylated SWTY peptide and 14-3-3 proteins or anti-phosphopeptide antibodies. Compared with a solution-based fluorescence anisotropy assay, our results support that the high throughput resonant waveguide grating biosensor system has favorable technical profiles in detecting protein-protein interactions that recognize phosphorylated motifs. Hence it provides a new generic HTS platform for phospho-detection.

14-3-3 Proteins↗

High-throughput capillary electrophoretic method for determination of total aminothiols in plasma and urine.

Increased interest in the analysis of aminothiols in body fluids during the last years results in a request for high-throughput analytical methods for their determination. We report here a novel, high-throughput method for the determination of total concentrations of biogenous aminothiols - homocysteine, cysteine, glutathione, cysteinylglycine, gamma-glutamylcysteine, and of penicilamine, mercaptopropionylglycine, and cysteamine, three compounds used to treat disorders of aminothiol metabolism in plasma and urine. Samples were reduced with tris(carboxyethyl)phosphine and labeled with 5-(bromomethyl)fluorescein. Capillary electrophoretic separations were performed in 60 mmol/L borate - 15 mmol/L sodium dodecyl sulfate - 2-amino-2-methyl-1-propanol, pH 10.0, with laser-induced fluorescence detection. Analysis time was less than 2 min. The assay is linear (r > 0.999) up to 500 micromol/L. Reproducibilities of migration times (coefficient of variation, CV) were < 0.5%. Interassay repeatabilities (CV, n = 10) were 5.08% and 6.09% for 5 micromol/L addition of homocysteine and 0.60% and 3.78% for 100 micromol/L addition of cysteine in plasma and urine, respectively. Recovery values were within 94-106% and sensitivity was better than 0.19 micromol/L for all analyzed compounds. Results agreed well with a standard high-performance liquid chromatography (HPLC) method. The diagnostic usefulness of the method has been proven on 79 samples of cystinuric patients and 12 samples of homocystinuric patients. We report here a novel method for the determination of aminothiols in body fluids by capillary electrophoresis (CE). Determination is fast and sensitive enough for diagnostic purposes.

Adolescent↗

High-throughput clonal selection of recombinant CHO cells using a dominant selectable and amplifiable metallothionein-GFP fusion protein.

Transfected mammalian cells can be used for the production of fully processed recombinant proteins for medical and industrial purposes. However, the isolation of high-producing clones is traditionally time-consuming. Therefore, we developed a high-throughput screening method to reduce the time and effort required to isolate high-producing cells. This involved the construction of an expression vector containing the amplifiable gene metallothionein (MT), fused in-frame to green fluorescent protein (GFP). The fusion gene (MTGFP) confers metal resistance similar to that of the wild-type metallothionein and expression can be monitored using either flow cytometry or a fluorometer to measure green fluorescence. Expression of MTGFP acted as a dominant selectable marker allowing rapid and more efficient selection of clones at defined metal concentrations than with the antibiotic G418. Cells harboring MTGFP responded to increasing metal concentrations with a corresponding increase in fluorescence. There was also a corresponding increase in recombinant protein production, indicating that MTGFP could be used as a selectable and amplifiable gene for the coexpression of foreign genes. Using our expression vector encoding MTGFP, we demonstrate a high-throughput clonal selection protocol for the rapid isolation of high-producing clones from transfected CHO cells. We were able to isolate cell lines reaching specific productivities of >10 microg hGH/10(6) cells/day within 4 weeks of transfection. The advantage of this method is that it can be easily adapted for automated procedures using robotic handling systems.

Animals↗

Reading dynamic kinase activity in living cells for high-throughput screening.

Protein kinases, as crucial signaling molecules, represent an emerging class of drug targets, and the ability to assay their activities in living cells with high-throughput screening should provide exciting opportunities for drug discovery and chemical and functional genomics. Here, we describe a general method for high-throughput reading of dynamic kinase activities using ratiometric fluorescent sensors, and showcase an example of reading intracellular activities of protein kinase A (PKA) and the cyclic adenosine monophosphate (cAMP)/PKA pathway downstream of many G-protein coupled receptors (GPCRs). We further demonstrate the first compound screen based on the ability of compounds to modulate dynamic kinase activities in living cells and show that such screening of a collection of clinical compounds has successfully identified modulators of the GPCR/cAMP/PKA pathway.

Cell Line↗

Recent advances in the discovery of organometallic catalysts using high-throughput screening assays.

Combinatorial techniques were developed initially to accelerate the identification of molecules with biological activity. The successes of these techniques inspired the design of high-throughput methods to assist in the discovery of new catalysts. Over the past year, many groups in academia and industry have utilized high-throughput screening assays to reduce the time required to identify catalysts for asymmetric processes, cross-coupling reactions and other metal-catalyzed transformations. The continued success of combinatorial techniques in organometallic chemistry should propagate the development of new and improved methods to facilitate catalyst discovery.

Catalysis↗

Identifying substrates for endothelium-specific Tie-2 receptor tyrosine kinase from phage-displayed peptide libraries for high throughput screening.

The peptide substrate specificity of Tie-2 was probed using the phage display method in order to identify efficient substrate for high throughput screening. Two random peptide libraries, pGWX3YX4 and pGWX4YX4, were constructed, in which all twenty amino acid residues were represented at the X positions flanking the fixed tyrosine residue Y. A fusion protein of GST and the catalytic domain of human Tie-2 was used to perform the phage phosphorylation. The phosphorylated phage particles were enriched by panning over immobilized anti-phosphotyrosine antibody pY20 for a total of 5 rounds. Four phage clones (3T61, 3T68, C1-90 and D1-15) that express a peptide sequence that can be phosphorylated by the recombinant catalytic domain of human Tie-2 were identified. Synthetic peptides made according to the sequences of the 4 selected clones from the two libraries, which had widely different sequences, were active substrates of Tie-2. Kinetic analysis revealed that D1-15 had the best catalytic efficiency with a k(cat)/K(m) of 5.9x10(4) M(-1) s(-1). Three high throughput screening assay formats, dissociation-enhanced lanthanide fluoroimmunoassay (DELFIA), radioactive plate binding (RPB) and time-resolved fluorescent resonance energy transfer (TR-FRET) were developed to assess the suitability of these phage display selected peptides in screening Tie-2 inhibitors. Three out of four peptides were functional in the DELFIA assay and D1-15 was functional in the TR-FRET assay.

Amino Acid Sequence↗

High-throughput DNA typing of HLA-A, -B, -C, and -DRB1 loci by a PCR-SSOP-Luminex method in the Japanese population.

We have developed a new high-throughput, high-resolution genotyping method for the detection of alleles at the human leukocyte antigen (HLA)-A, -B, -C, and -DRB1 loci by combining polymerase chain reaction (PCR) and sequence-specific oligonucleotide probes (SSOPs) protocols with the Luminex 100 xMAP flow cytometry dual-laser system to quantitate fluorescently labeled oligonucleotides attached to color-coded microbeads. In order to detect the HLA alleles with a frequency of more than 0.1% in the Japanese population, we created 48 oligonucleotide probes for the HLA-A locus, 61 for HLA-B, 34 for HLA-C, and 51 for HLA-DRB1. The accuracy of the PCR-SSOP-Luminex method was determined by comparing it to the nucleotide sequencing method after subcloning into the plasmid vector using 150 multinational control samples obtained from the International HLA DNA Exchange University of California Los Angeles. In addition, we performed the PCR-SSOP-Luminex method for HLA allele typing on DNA samples collected from 1,018 Japanese volunteers. Overall, the genotyping method exhibited an accuracy of 85.91% for HLA-A, 85.03% for HLA-B, 97.32% for HLA-C, and 90.67% for HLA-DRB1 using 150 control samples, and 100% for HLA-A and -C, 99.90% for HLA-B, and 99.95% for HLA-DRB1 in 1,018 Japanese samples. The PCR-SSOP-Luminex method provides a simple, accurate, and rapid approach toward multiplex genotyping of HLA alleles to the four-digit or higher level of resolution in the Japanese population. It takes only approximately 5 h from DNA extraction to the definition of HLA four-digit alleles at the HLA-A, HLA-B, HLA-C, and HLA-DRB1 loci for 96 samples when handled by a single typist.

DNA Primers↗

High-throughput positive-dielectrophoretic bioparticle microconcentrator.

We introduce a new dielectrophoretic particle microconcentrator that combines interdigitated electrodes with a chaotic mixer to achieve high-throughput (>100 microL/min) particle concentration. The interdigitated electrodes use positive dielectrophoresis to attract particles to the surface, while the chaotic mixer circulates the particles to increase the number brought in proximity with the surface. We have used this microconcentrator to concentrate both beads and B. subtilis spores and have developed a microvolume concentration measurement method to determine the delivered off-chip concentration enhancement of the output sample. The resulting microconcentrator is sufficiently high throughput to serve as an interface between macroscale sample collectors and micro- or nanoscale detectors.

Bacillus subtilis↗

The application of high-throughput screening to novel lead discovery.

The ability to discover new lead compounds for novel therapeutic targets is a pivotal step in drug discovery programmes. High-throughput screening (HTS) utilises a number of platforms for the rapid screening of novel targets to accelerate this process. Key issues in HTS include assay configuration and the ability of a high-throughput screen to predict drug-target interactions accurately. This review highlights a number of issues in the HTS process and describes three key target areas that are likely to be sources of novel, therapeutically important drugs. Particular emphasis is placed on the mechanistic basis of drug-target interactions that are of prime importance in the design of HTS approaches. Critical aspects of information management related to HTS are summarised.

Animals↗

Diagnostic markers of ovarian cancer by high-throughput antigen cloning and detection on arrays.

A noninvasive screening test would significantly facilitate early detection of epithelial ovarian cancer. This study used a combination of high-throughput selection and array-based serologic detection of many antigens indicative of the presence of cancer, thereby using the immune system as a biosensor. This high-throughput selection involved biopanning of an ovarian cancer phage display library using serum immunoglobulins from an ovarian cancer patient as bait. Protein macroarrays containing 480 of these selected antigen clones revealed 65 clones that interacted with immunoglobulins in sera from 32 ovarian cancer patients but not with sera from 25 healthy women or 14 patients having other benign or malignant gynecologic diseases. Sequence analysis data of these 65 clones revealed 62 different antigens. Among the markers, we identified some known antigens, including RCAS1, signal recognition protein-19, AHNAK-related sequence, nuclear autoantogenic sperm protein, Nijmegen breakage syndrome 1 (Nibrin), ribosomal protein L4, Homo sapiens KIAA0419 gene product, eukaryotic initiation factor 5A, and casein kinase II, as well as many previously uncharacterized antigenic gene products. Using these 65 antigens on protein microarrays, we trained neural networks on two-color fluorescent detection of serum IgG binding and found an average sensitivity and specificity of 55% and 98%, respectively. In addition, the top 6 of the most specific clones resulted in an average sensitivity and specificity of 32% and 94%, respectively. This global approach to antigenic profiling, epitomics, has applications to cancer and autoimmune diseases for diagnostic and therapeutic studies. Further work with larger panels of antigens should provide a comprehensive set of markers with sufficient sensitivity and specificity suitable for clinical testing in high-risk populations.

Antigens, Neoplasm↗

Mismatch repair detection (MRD): high-throughput scanning for DNA variations.

Although there are several methods for genotyping previously identified single nucleotide polymorphisms (SNPs), there is a paucity of approaches for high-throughput scanning for unknown variations. Mismatch repair detection (MRD) utilizes a bacterial mismatch repair system in vivo to detect sequence variants in human DNA samples. We describe modifications in MRD that allow a high degree of parallel processing, and use this modified version to accurately scan for variations in 35 different human DNA fragments simultaneously. MRD's potential for high-throughput scanning can be used to identify new SNPs and to comprehensively compare sequences between patients and controls for identifying disease susceptibility alleles.

Base Pair Mismatch↗

High-throughput phenotypic profiling of gene-environment interactions by quantitative growth curve analysis in Saccharomyces cerevisiae.

Cell-based assays are widely used in high-throughput screening to determine the effects of toxicants and drugs on their biological targets. To enable a functional genomics modeling of gene-environment interactions, quantitative assays are required both for gene expression and for the phenotypic responses to environmental challenge. To address this need, we describe an automated high-throughput methodology that provides phenotypic profiling of the cellular responses to environmental stress in Saccharomyces cerevisiae. Standardized assay conditions enable the use of a single metric value to quantify yeast microculture growth curves. This assay format allows precise control of both genetic and environmental determinants of the cellular responses to oxidative stress, a common mechanism of environmental insult. These yeast-cell-based assays are validated with hydrogen peroxide, a simple direct-acting oxidant. Phenotypic profiling of the oxidative stress response of a yap1 mutant strain demonstrates the mechanistic analysis of genetic susceptibility to oxidative stress. As a proof of concept for analysis of more complex gene-environment interactions, we describe a combinatorial assay design for phenotypic profiling of the cellular responses to tert-butyl hydroperoxide, a complex oxidant that is actively metabolized by its target cells. Thus, the yeast microculture assay format supports comprehensive applications in toxicogenomics.

Environment↗

High throughput proteome screening for biomarker detection.

Mass spectrometry-based quantitative proteomics has become an important component of biological and clinical research. Current methods, while highly developed and powerful, are falling short of their goal of routinely analyzing whole proteomes mainly because the wealth of proteomic information accumulated from prior studies is not used for the planning or interpretation of present experiments. The consequence of this situation is that in every proteomic experiment the proteome is rediscovered. In this report we describe an approach for quantitative proteomics that builds on the extensive prior knowledge of proteomes and a platform for the implementation of the method. The method is based on the selection and chemical synthesis of isotopically labeled reference peptides that uniquely identify a particular protein and the addition of a panel of such peptides to the sample mixture consisting of tryptic peptides from the proteome in question. The platform consists of a peptide separation module for the generation of ordered peptide arrays from the combined peptide sample on the sample plate of a MALDI mass spectrometer, a high throughput MALDI-TOF/TOF mass spectrometer, and a suite of software tools for the selective analysis of the targeted peptides and the interpretation of the results. Applying the method to the analysis of the human blood serum proteome we demonstrate the feasibility of using mass spectrometry-based proteomics as a high throughput screening technology for the detection and quantification of targeted proteins in a complex system.

Automation↗

High-throughput single strand conformation polymorphism mutation detection by automated capillary array electrophoresis: validation of the method.

Capillary array electrophoresis (CAE) is a novel technique, which allows for high throughput analysis of DNA fragments. When screening for mutations in whole populations or large patient groups it is necessary to have robust and well-characterized setups for high throughput analysis. For large-scale mutation screening, we have developed procedures for single strand conformation polymorphism (SSCP) assays using CAE (CAE-SSCP) whereby we may increase both the sensitivity and the throughput compared to conventional SSCP analysis. In this study we have validated CAE-SSCP by 1) comparing detection by slab-gel based SSCP with CAE-SSCP of mutations in the MYH7, MYL2, and MYL3 genes encoding sarcomere proteins from patients suffering from hypertrophic cardiomyopathy; and 2) by constructing a series of 185 mutants having substitution mutations, as well as insertion/deletion mutations, or some combinations of these, in different sequence contexts in four exons and different positions relative to the end of the amplicon (three from the KCNQ1 gene, encoding a cardiac potassium channel, and one from the TNNI3 gene encoding cardiac troponin I). The method identified 181 out of 185 mutations (98%), and the data suggest that the position of mutation in the fragment had no effect on the sensitivity. Analysis of the specificity of the method showed that only very few mutants could not be distinguished from each other and there were no false positives.

Automation↗

Miniaturized FRET assays and microfluidics: key components for ultra-high-throughput screening.

Assay miniaturization applicable across a wide range of target classes, along with automation and process integration, are well-recognized goals for ultra-high-throughput screening on an industrial scale. This report summarizes the implementation of fluorescence resonance energy transfer (FRET)-based biochemical and cell-based assays in 3456-well NanoWelltrade mark assay plates using key components of Aurora's ultra-high-throughput screening system.

Journal Article↗

The use of GAP-43 mRNA quantification in high throughput screening of putative neuroprotective agents in dorsal root ganglion cultures.

Large scale screening for neuroprotective drugs for peripheral neuropathies requires development of a high throughput system that is reliable and reproducible. Currently most accurate outcome measures of axonal degeneration are based on time-consuming, laborious measurement of morphological changes in neurites. In order to improve on the scalability of the screening procedure we developed a real-time RT-PCR based method of gene expression that correlates very well with morphological measures of neuritic degeneration. We examined the changes in GAP-43 expression in primary dorsal root ganglion (DRG) neurons in vitro with exposure to a zalcitabine (ddC), an antiretroviral drug that causes neuropathy in human immunodeficiency virus (HIV)-infected individuals, with and without FK506, an immunophilin ligand with neuroprotective and neuroregenerative properties. Similar to morphological measures of neuritic degeneration, in ddC-treated cultures there was a reduction in the expression of GAP-43 mRNA. This was prevented, in a dose-dependent manner, by co-administration of FK506. This assay, performed in a 96-well format, can easily be scaled for high throughput screening (HTS) using robotic systems.

Animals↗