Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Comparison of visual and quantitative analysis for characterization of insonated liver tumors after microbubble contrast injection.

OBJECTIVE: The objective of our study was to compare diagnostic performance of visual and quantitative analysis for the characterization of liver tumors insonated at low transmit power after microbubble contrast agent injection. SUBJECTS AND METHODS: This series comprised 166 liver tumors (1-5 cm in diameter) in 166 patients (99 men, 67 women; mean age +/- SD, 58 +/- 11 years) scanned at low transmit power (mechanical index: 0.1-0.14) after sulfur hexafluoride-filled microbubble injection. Digital cine clips recorded at the arterial phase (10-40 sec after contrast injection) and late phase (100-300 sec) were analyzed to characterize liver tumors as benign or malignant. Visual analysis was performed by three independent blinded reviewers who evaluated enhancement patterns at the arterial phase and subjective tumor conspicuity at the late phase. Quantitative analysis of videotape intensity (VI: gray-scale levels, 0-255) was performed to calculate objective tumor conspicuity at the late phase: (VI(tumor) - VI(liver)) / VI(liver). RESULTS: Characteristic enhancement patterns were observed in malignant tumors (peripheral rimlike) and benign tumors (peripheral nodular or central and spoke-wheel-shaped). Malignant (n = 95) versus benign (n = 71) tumors differed for subjective (median value: -1 vs 1, respectively) and objective conspicuity at the late phase (-0.6 vs 0.15, respectively; p = 0.001, Mann-Whitney U test) due to persistent microbubble uptake in benign tumors. Diagnostic performance of visual (odds ratio: reviewer 1 = 4.28, reviewer 2 = 10.18, reviewer 3 = 9.56) and quantitative (odds ratio: 89.33) analyses differed significantly in the characterization of liver tumors (p = 0.01, chi-square test). CONCLUSION: Quantitative analysis revealed higher diagnostic performance than visual analysis to characterize liver tumors insonated at low transmit power after microbubble contrast agent injection.

Adult↗

Comparison of periapical and detailed narrow-beam radiography for diagnosis of periodontal pathology.

The diagnostic performance of the detailed narrow-beam (DNB) technique of the Scanora multimodal X-ray system was compared with periapical radiography for detecting periodontal pathology. In total, 253 sites in 133 patients were examined. Receiver operating characteristics (ROC) of both imaging modalities were analyzed in relation to the ratings of five observers for the whole dentition, three dental regions and five types of periodontal lesion. ROC analysis demonstrated that the overall diagnostic performance of DNB radiography was better (P < 0.05) than that of periapical radiography. DNB radiography was significantly superior (P < 0.01) for detecting marginal widening of periodontal membrane space, but there was no significant difference between the two techniques for crestal erosion, vertical bone loss, furcation involvement or calculus. The regional differences found in overall diagnostic performance of the two imaging modalities were not significant. The sensitivity for periapical radiography was 71% and for DNB radiography 85%, and the specificities 82% and 81% respectively. It is concluded that DNB radiography is a good radiographic examination for periodontal disease, and an acceptable alternative to periapical radiography.

Adult↗

Simulated bone erosions in a hand phantom: detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector.

PURPOSE: To assess the diagnostic performance of an active-matrix flat-panel x-ray detector for reduced-dose imaging of simulated arthritic lesions. MATERIALS AND METHODS: A digital x-ray detector based on cesium iodide and amorphous silicon technology with a panel size of 43 x 43 cm, matrix of 3,000 x 3,000 pixels, pixel size of 143 micrometer, and digital output of 14 bits was used. State-of-the-art screen-film radiographs were compared with digital images obtained at doses equivalent to those obtained with system speeds of 400, 560, and 800. The phantom was composed of a human hand skeleton on an acrylic plate with drilled holes simulating bone erosions of different diameters and depths. Results of four independent observers were evaluated with receiver operating characteristic curve analysis. RESULTS: The cesium iodide and amorphous silicon detector resulted in better diagnostic performance than did the screen-film combination, with the dose being the same for both modalities (P <.05). For digital images obtained at reduced doses, no significant differences were found. CONCLUSION: The improved diagnostic performance with digital radiographs obtained with the cesium iodide and amorphous silicon detector suggests that this detector technology holds promise in terms of dose reduction for specific diagnostic tasks, without loss of diagnostic accuracy.

Arthritis↗

Update of breast MR imaging architectural interpretation model.

PURPOSE: To (a) validate a breast magnetic resonance (MR) interpretation model, (b) expand the tree-shaped prediction model to increase specificity without decreasing sensitivity, and (c) reevaluate the model's diagnostic performance. MATERIALS AND METHODS: Two hundred sixty-two new patients with palpable or mammographic abnormalities underwent MR imaging, and pathologic evaluation was performed. They were entered prospectively into the model, which yielded 454 patients in the construction (training) and validation (test) phases. Predictive values for previously published terminal nodes or branch points of the model were compared between the training and test data sets. Ductal enhancement morphology, regional enhancement micronodularity, regional enhancement degree, and focal mass T2 signal intensity were evaluated for model expansion. Diagnostic performance characteristics of the model were recalculated. RESULTS: For previously published nodes, absence of a lesion visible at MR imaging, smooth masses, lobulated masses with nonenhancing internal septations, and lobulated masses with minimal or no enhancement had negative predictive values (NPVs) for malignancy similar in both data sets (96% vs 99%, 100% vs 93%, 100% vs 98%, and 100% vs 100%). Irregular masses with internal septations (100% vs 0%) and spiculated masses with no or minimal enhancement (100% vs 50%) did not. Nonseptated enhancing lobulated masses with low T2 signal intensity were added as a benign terminal node (NPV, 100%). Mild regional enhancement (NPV, 92%) was added but not considered a terminal node. Sensitivity, specificity, NPV, positive predictive value, and accuracy of the expanded model were 96%, 80%, 96%, 78%, and 87%, respectively. CONCLUSION: Additional investigation yielded a slightly modified model, but the diagnostic performance characteristics remain high, similar to those originally published.

Adult↗

Detection of articular cartilage lesions: experimental evaluation of low- and high-field-strength MR imaging at 0.18 and 1.0 T.

The objective of this study was to compare the diagnostic performance of a dedicated orthopedic magnetic resonance (MR) imaging system (0.18 T) and a conventional MR imaging system (1.0 T) in the detection of articular cartilage lesions. Fifty knee joint specimens of pigs with artificially created articular cartilage lesions of different diameters, grades (2-3), and localizations, as well as 50 joints with intact articular cartilage, were imaged at 0. 18 and 1.0 T. Diagnostic performance was determined by means of receiver operating characteristics (ROC) analysis with three independent observers. For none of the pulse sequences used at 0.18 T or 1.0 T areas under ROC curves (A(z)) showed significant differences between the three observers. A(z) values from averaged data were as follows: a) 0.18 T: T1-weighted spin echo (SE): 0.70, proton-density-weighted SE: 0.59, T2-weighted SE: 0.61, two-dimensional (2D) gradient-echo (GRE): 0.73, 3D GRE: 0.75; and b) 1.0 T: T1-weighted SE: 0.73, fat-suppressed T2-weighted turbo-SE: 0. 79, 2D fast low-angle shot (FLASH): 0.79, fat-suppressed 3D FLASH: 0. 96, and water-excited 3D double-echo steady state (DESS): 0.96. With the use of 3D pulse sequences, the high-field system demonstrated a significantly better diagnostic performance than the low-field system in the detection of grades 2 and 3 articular cartilage lesions (P < 0.001).

Animals↗

Diagnostic value of anti-human citrullinated fibrinogen ELISA and comparison with four other anti-citrullinated protein assays.

We studied the diagnostic performance of the anti-human citrullinated fibrinogen antibody (AhFibA) ELISA for rheumatoid arthritis (RA) in a consecutive cohort (population 1) and evaluated the agreement between the AhFibA ELISA and four other assays for anti-citrullinated protein/peptide antibodies (ACPAs) as well as rheumatoid factor in patients with longstanding RA (population 2). Population 1 consisted of 1024 patients with rheumatic symptoms; serum samples from these patients were sent to our laboratory for ACPA testing within the context of a diagnostic investigation for RA. Ninety-two of these patients were classified as having RA according to the American College of Rheumatology criteria and 463 were classified as non-RA patients. Population 2 consisted of 180 patients with longstanding RA and was used to assess agreement and correlations between five ACPA assays: anti-cyclic citrullinated peptide (CCP)1 and anti-CCP2 antibodies were detected using a commercially available ELISA, AhFibA using ELISA, and anti-PepA and anti-PepB antibodies using line immunoassay. Applying previously proposed cut-offs for AhFibA, we obtained a sensitivity of 60.9% and a specificity of 98.7% in population 1. Receiver operating characteristic curve analysis could not detect a significant difference in diagnostic performance between the AhFibA ELISA and anti-CCP2 assay. Performing a hierarchical nearest neighborhood cluster analysis of the five different ACPA assays in population 2, we identified two clusters: a cluster of anti-pepA, anti-pepB and anti-CCP1, and a cluster of AhFibA and anti-CCP2. In conclusion, we found that AhFibA and anti-CCP2 antibodies had similar diagnostic performance. However, disagreement between ACPA tests may occur.

Adolescent↗

Breast disease: clinical application of US elastography for diagnosis.

PURPOSE: To evaluate the diagnostic performance of real-time freehand elastography by using the extended combined autocorrelation method (CAM) to differentiate benign from malignant breast lesions, with pathologic diagnosis as the reference standard. MATERIALS AND METHODS: This study was approved by the University of Tsukuba Human Subjects Institutional Review Board; all patients gave informed consent. Conventional ultrasonography (US) and real-time US elastography with CAM were performed in 111 women (mean age, 49.4 years; age range, 27-91 years) who had breast lesions (59 benign, 52 malignant). Elasticity images were assigned an elasticity score according to the degree and distribution of strain induced by light compression. The area under the curve and cutoff point, both of which were obtained by using a receiver operating characteristic curve analysis, were used to assess diagnostic performance. Mean scores were examined by using a Student t test. Sensitivity, specificity, and accuracy were compared by using the standard proportion difference test or the Delta-equivalent test. RESULTS: For elasticity score, the mean +/- standard deviation was 4.2 +/- 0.9 for malignant lesions and 2.1 +/- 1.0 for benign lesions (P < .001). When a cutoff point of between 3 and 4 was used, elastography had 86.5% sensitivity, 89.8% specificity, and 88.3% accuracy. When a best cutoff point of between 4 and 5 was used, conventional US had 71.2% sensitivity, 96.6% specificity, and 84.7% accuracy. Elastography had higher sensitivity than conventional US (P < .05). By using equivalence bands for noninferiority or equivalence, it was shown that the specificity of elastography was not inferior to that of conventional US and that the accuracy of elastography was equivalent to that of conventional US. CONCLUSION: For assessing breast lesions, US elastography with the proposed imaging classification, which was simple compared with that of the Breast Imaging Recording and Data System classification, had almost the same diagnostic performance as conventional US.

Adult↗

Influence of image processing on chest radiograph interpretation and decision changes.

RATIONALE AND OBJECTIVES: The authors investigate the effect of image processing on diagnostic performance in the reading of computed chest radiographs. MATERIALS AND METHODS: Six radiologists read 168 chest images with and without the use of image processing. Diagnostic performance was measured by means of receiver operating characteristic analysis, and changes made in diagnostic decisions with the use of image processing were evaluated. RESULTS: There were no statistically significant differences between reader performance with image processing and reader performance without image processing (P < .05). Readers' decisions were just as likely to change from false-negative to true-positive as from true-positive to false-negative with the use of image processing. More decisions changed from true-negative to false-positive than from false-positive to true-negative with processing, CONCLUSION: The effect of image processing does not greatly influence diagnostic performance in chest radiography.

Attitude of Health Personnel↗

Ski-flying: related catecholamine excretion compared with cross-country skiing.

We examined the catecholamine excretion and its performance-diagnostic relevance in athletes of the German National Team during ski-flying and cross-country skiing. Five athletes were examined during the 1986 World Championship ski-flying competition and eight athletes during a 24-km cross-country qualification test. There is little doubt that the special competitive conditions have considerable influence on the usefulness of these data. We decided to publish the results anyway since the results may expand our knowledge about the performance-diagnostic relevance of catecholamine excretion under competitive conditions. During cross-country skiing, the average noradrenaline elimination (1166 pmol.min-1) was about 150% higher and the average adrenaline elimination (243 pmol.min-1) about 30% lower than during ski-flying. The noradrenaline-adrenaline ratio was about 4.8 in cross-country skiing and 1.3-1.5 in ski-flying. Catecholamine excretion does, as expected, therefore permit differentiation of the various strains on the organism. The impression with respect to performance-diagnostic relevance arises that successful athletes show a more stable and lower excretion of noradrenaline under competitive conditions. This can only be a preliminary statement; it should serve to stimulate discussion and further investigations of the problem.

Catecholamines↗

The use of axial reconstructed images from three-dimensional MRI datasets for morphological diagnosis of meniscal tears of the knee.

INTRODUCTION: In recent years, three-dimensional (3D) MRI has been utilized to detect meniscal tears and has displayed several advantages over 2D MRI. The diagnostic performance to discriminate the type of meniscal tears by 2D MRI (sagittal and coronal images) and axial images from 3D MRI datasets has not been reported yet. The aim of the present study is to evaluate the efficacy of the axial reconstructed images from 3D MRI datasets for the morphological diagnosis of meniscal tears of the knee. MATERIALS AND METHODS: Seventy-four menisci in 37 patients who underwent arthroscopic surgery of the knee were studied. All patients were examined by 2D sagittal and coronal MRI and by axial images from 3D MRI datasets prior to surgery. First, we compared the diagnostic performance for meniscal tears by 2D sagittal and coronal MRI to that by axial images from 3D MRI datasets as judged by arthroscopic findings. Second, we compared the correlation of tear types presumed from 2D sagittal and coronal MRI to arthroscopy with those presumed from axial images from 3D MRI datasets to arthroscopy. RESULTS: For the diagnostic performance of meniscal tears on 2D MRI, the sensitivity, specificity and accuracy were 93.5%, 88.4% and 90.5%, respectively. On axial images from 3D MRI, the sensitivity, specificity and accuracy were 96.8%, 79.1% and 86.5%, respectively. Nine cases were false-positive on axial images, while 5 cases were false-positive on 2D images. Correlations to arthroscopy were 100% by both scans for longitudinal tears and discoid meniscus tears. Only 29% were correctly diagnosed by 2D sagittal and coronal images for radial tears, however, all radial tears could be correctly diagnosed by axial images. All horizontal tears were correctly diagnosed on 2D sagittal and coronal images, while none of the horizontal tears could be correctly diagnosed from axial images. CONCLUSION: Axial images from 3D MRI datasets were useful in the diagnosis of radial tears, but two limitations are noted concerning the use of axial images. First, medial menisci should be carefully read on axial slices because of the relatively high rate of false-positives on medial menisci. Second, axial images cannot discriminate horizontal tears from other types of meniscus tears.

Adolescent↗

Plasma pro-B-type natriuretic peptide in the general population: screening for left ventricular hypertrophy and systolic dysfunction.

AIMS: B-type natriuretic peptide (BNP) measurement in screening for left ventricular hypertrophy (LVH) and left ventricular systolic dysfunction (LVSD) has been evaluated in the general population, but corresponding information on proBNP and the N-terminal proBNP fragment is still limited. We therefore examined whether proBNP measurement is useful for LVH and LVSD screening in the general population. METHODS AND RESULTS: In the 4th Copenhagen City Heart Study, 3497 participants underwent echocardiography with assessment of left ventricular ejection fraction (LVEF) and mass. The impact of gender and age was determined and the diagnostic performance of the plasma proBNP concentration was evaluated using receiver operating characteristic (ROC) curves. Of 1502 men and 1995 women, 4.1 and 2.6% had LVSD defined as an LVEF<60% whereas only 0.4% displayed LVEF<40%. The proBNP concentration was 1.7-fold higher in women compared with men (P<0.0001) and related to age in both genders. The mean proBNP plasma concentration was two-fold higher in subjects with LVSD than without LVSD (P<0.0001). Likewise, LVH imposed a 1.9-fold increase in the proBNP concentration (P<0.0001): Both differences persisted after adjusting for ischaemic heart disease, hypertension, diabetes, gender, and age. The diagnostic performance of proBNP in detecting LVEF<40% was high with an area under the ROC curves of 0.92 (95% CI 0.79-1.00) in women and 0.85 (95% CI 0.74-0.96) in men. CONCLUSION: We have established the impact of age and gender on the proBNP concentration in a large, community-based cohort. The diagnostic performance for proBNP measurement in screening for LVH and LVSD in the general population parallels the reported data for BNP.

Echocardiography↗

Volumetric capnography as a screening test for pulmonary embolism in the emergency department.

STUDY OBJECTIVE: To compare the diagnostic performance of volumetric capnography (VCap), which is the plot of the expired CO(2) partial pressure against the expired volume during a single breath, with the PaCO(2) to end-tidal CO(2) (EtCO(2)) gradient, in the case of suspected pulmonary embolism (PE). DESIGN: Single-center, prospective study. SETTING: Emergency department of a teaching hospital. PATIENTS: A total of 45 outpatients with positive enzyme-linked immunosorbent assay d-dimer levels of > 500 ng/mL. The diagnosis of PE was confirmed in 18 outpatients according to a validated procedure based on the ventilation-perfusion lung scan and/or spiral CT scanning. INTERVENTIONS: Curves of VCap were obtained from a compact monitor connected to a computer. A sequence of four to six stable breaths allowed the calculation of the following several variables: alveolar dead space fraction; the ratio of alveolar dead space (VDalv) to airway dead space (VDaw); the VDalv to physiologic dead space (VDphys) fraction; the slope of phase 3; and the late dead space fraction (Fdlate) corresponding to the extrapolation of the capnographic curve to a volume of 15% of the predicted total lung capacity. RESULTS: The mean (+/- SD) PaCO(2)-EtCO(2) gradient was 5.3 +/- 0.7 mm Hg in the PE-positive group and 2.8 +/- 0.7 mm Hg in the PE-negative group (p = 0.019). Four variables of the VCap exhibited a statistical difference between both groups, as follows: the VDalv/VDaw fraction(;) the slope of phase 3; the VDalv/VDphys fraction; and the Fdlate, which was 8.2 +/- 3.3% vs -7.7 +/- 2.8%, respectively (p = 0.000011). The diagnostic performance expressed as the mean area under a receiver operating characteristic curve comparison was 75.9 +/- 7.4% for the PaCO(2)-EtCO(2) gradient and 87.6 +/- 4.9% for the Fdlate (p = 0.02). CONCLUSION: Fdlate, a variable of VCap, had a statistically better diagnostic performance in suspected PE than the PaCO(2)-EtCO(2) gradient. VCap is a promising computer-assisted bedside application of pulmonary pathophysiology. Future research should define the place of this technique in the diagnostic workup of PE, especially in the presence of positive d-dimers.

Breath Tests↗

Comparison between two hand-held autorefractors: the Sure-Sight and the Retinomax.

PURPOSE: To compare the results of manifest refraction obtained with two different hand-held autorefractors (Sure-Sight, Welch Allyn Co. and Retinomax 1, Nikon Inc.) and with the Topcon RMA 6000 on-table autorefractor in order to estimate any potential bias between these refractometers and to compare the diagnostic performances of these two hand-held autorefractors as screening devices. METHODS: Ninety-eight children were refracted under manifest conditions with the three above-mentioned refractometers and under cycloplegic conditions with the Topcon on-table autorefractor, or by means of retinoscopy. The agreement between the manifest measurements obtained with the three different autorefractors was studied using the method of Bland and Altman. The validity of several thresholds of manifest refractive anomalies as measured with the Sure-Sight and with the Retinomax was estimated by receiver operating characteristic (ROC) curves using cycloplegic measures as reference. results There is a spherical positive bias of 1 D between the Sure-Sight and the Retinomax and better agreement between the Topcon and the Retinomax. The surface area indexes of the ROC curves and the diagnostic performances in term of sensitivity and specificity are better with the Retinomax in cases of hyperopia, astigmatism and anisometropia. For myopia, the Sure-Sight has better performance. CONCLUSIONS: The results suggest that either device may be sufficient for assessing refractive errors in children in a screening setting. However, because of a bias between both refractometers in measuring the sphere, distinctive referral criteria must be chosen for the detection of hyperopia and myopia. The diagnostic performance is slightly in favor of the Retinomax.

Adolescent↗

[Procalcitonin in the early diagnosis of invasive bacterial infection in febrile infants].

BACKGROUND: Procalcitonin (PCT) it is a new marker of bacterial infection. Because of its shorter half-life and earlier ascent it offers advantages over C-reactive protein (CRP). OBJECTIVE: To compare the diagnostic performance of PCT in the early detection of invasive bacterial infection in infants with that of CPR. MATERIAL AND METHODS: Between January of 1998 and February of 2000 we performed a prospective observational study in the emergency department of infants aged between 1 and 36 months who had been treated for fever and for whom PCT and CRP plasmatic values had been obtained. Plasmatic PCT and PCR values were evaluated and correlated with the final diagnosis. ROC curves for both markers were calculated. RESULTS: One hundred infants with a mean age of 8.8 months (SD 7.59) were included in four groups of 25 patients each (viral infection, localized bacterial infection, invasive bacterial infection and control group). The mean PCT and CRP values in invasive bacterial infections [PCT: 14.45 ng/mL (SD 27.95) and CRP: 95.10 mg/L (SD 7 2.77)] were significantly higher than in non-invasive infections [PCT: 0.27 ng/mL (SD 0.19) and CRP: 25.67 mg/L (SD 33.04)] but the diagnostic performance of PCT was better. The area under the curve for PCT was 0.95 (SD 0.03), which was significantly higher (p < 0.001) than that obtained for CRP [0.81 (SD 0.05)]. The optimal cut-off for PCT was > 0.4 ng/mL (sensitivity: 95.5 %; specificity: 86.4 %) and that for CRP was > 42.9 mg/L (sensitivity: 75 %; specificity: 81.8 %). In infants who had fever for less than 12 hours (n 30) the area under the curve for PCT was 0.90 (SD 0.06), which was higher (p < 0.001) than that for PCR [0.64 (SD 0.11)]. The optimal cut-off for PCT in this group was > 0.4 ng/mL (sensitivity: 90 %; specificity: 94 %) and that for CRP was > 26.6 mg/L (sensitivity: 60 %; specificity: 77.8 %). CONCLUSIONS: The diagnostic performance of PCT was higher than that of CRP in the early detection of invasive infection in febrile infants, even when evolution was less than 12 hours.

Bacterial Infections↗

Cardiac troponin T as a marker for myocardial ischemia in patients seen at the emergency department for acute chest pain.

BACKGROUND: Identification of patients with acute chest pain at high risk for cardiovascular complications is a common and difficult challenge for clinicians and must be based initially on data from the history, physical examination, electrocardiogram, and chest radiograph. Some data suggest that elevations in cardiac troponin T (cTnT) may be useful for detection of less severe degrees of myocardial injury that may occur in some patients with unstable angina. Therefore we designed a prospective follow-up study to assess the diagnostic performance and prognostic value of cTnT in a population of patients presenting to the emergency department with acute chest pain. METHODS: The patient population included all 1477 admitted patients aged 30 years or more who presented to the emergency department of an urban teaching hospital from October 1992, through February 1994, with a chief symptom of acute chest pain not explained by trauma or chest radiograph abnormalities. The 1303 patients (88%) who had 2 or more measurements of cTnT during the first 24 hours after presentation comprised the final study population. Sensitivity, specificity, positive predictive value, negative predictive value, and receiver operator characteristics curve (ROC) were determined for cTnT and creatine kinase-MB (CK-MB) (measured using activity and mass assays) data from the first 24 hours after admission for the outcomes of acute myocardial infarction (AMI) and major cardiac events during the first 72 hours of hospitalization. RESULTS: The sensitivity and specificity of cTnT (threshold of 0.1 ng/mL) for detecting AMI during the first 24 hours after presentation were 99% and 86%, respectively. The CK-MB activity and mass assays had diagnostic performance for detecting AMI similar to cTnT. Among patients who did not meet study criteria for AMI, cTnT was elevated during the first 24 hours in 31% of patients who had major complications, compared with a 17% rate for the CK-MB activity assay and a 3% rate for the CK-MB mass assay. In these patients, the cTnT assay had superior diagnostic performance compared with the CK-MB mass assay as a marker for cardiac complications as assessed with ROC analysis (P <.0004). CONCLUSIONS: In a heterogeneous population of patients seen in the emergency department with acute chest pain, cTnT was similar to CK-MB (activity and mass assays) for detection of AMI and superior to the CK-MB mass assay as a marker for major cardiac events early in the hospital course among those who were ruled out for an AMI. Further study is required to determine how this assay can be used to provide more appropriate, cost-effective care.

Acute Disease↗

MIC-based tuberculosis drug susceptibility testing using Sensititre MYCOTB: a diagnostic accuracy meta-analysis.

Accurate drug susceptibility testing (DST) is crucial for designing effective regimens for multidrug-resistant (MDR) and pre-extensively drug-resistant tuberculosis (pre-XDR TB). Sensititre MYCOTB enables simultaneous determination of minimum inhibitory concentrations (MICs) for multiple drugs, but its diagnostic performance varies across studies. This meta-analysis evaluated the diagnostic performance of Sensititre MYCOTB for key MDR and pre-XDR TB drugs. The protocol was registered in PROSPERO (CRD420251230599). PubMed, Cochrane, Google Scholar, Scopus, ONOS, Web of Science, ScienceDirect, and registries were systematically searched for studies published between 2010 and 2025. Studies comparing the Sensititre MYCOTB with reference DST for Mycobacterium tuberculosis complex (MTBC) were included. Bias assessment and pooled diagnostic accuracy estimates were generated. Fourteen studies, including 1,728 isolates, were analyzed. Rifampicin and isoniazid demonstrated high sensitivity (0.976 [95% CI: 0.94-0.99] and 0.977 [95% CI: 0.95-0.99]) and specificity (0.958 [95% CI: 0.84-0.98] and 0.957 [95% CI: 0.83-0.99], respectively) with low heterogeneity. Amikacin, kanamycin, and ofloxacin demonstrate good diagnostic accuracy, with high specificity (>0.98 [95% CI]). Moderate diagnostic accuracy was observed for ethambutol, streptomycin, ethionamide, and rifabutin. Cycloserine, moxifloxacin, and para-aminosalicylic acid showed inconsistent performance despite excellent specificity (>0.97 [95% CI]). Sensitivity analysis partially improved pooled sensitivity for moxifloxacin 0.801 (95% CI: 0.585-0.924) and para-aminosalicylic acid 0.76 (95% CI: 0.518-0.894), whereas cycloserine remained at 0.436 (95% CI: 0.190-0.725), although heterogeneity persisted. Sensititre MYCOTB DST demonstrates high diagnostic accuracy for MDR-TB and pre-XDR-TB drugs, while caution is required with cycloserine, moxifloxacin, and para-aminosalicylic acid. These findings support the integration of MIC-based testing into clinical decision-making.

Microbial Sensitivity Tests↗

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans↗