Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ULTRASONICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Effect of ultrasonic power on the structure of activated carbon and the activities of Ru/AC catalyst.

Ruthenium-based materials are the second-generation catalysts for ammonia synthesis. Ruthenium is less inhibited by ammonia, less sensitive to poisons, and more active than the traditional iron-based catalyst. The relatively high cost of Ru compared to that of iron requires a high dispersion of the metal on a suitable support. Carbon-supported Ru catalysts with promoters have been reported to be active for ammonia synthesis. The ultrasonic technique has been proven to be beneficial to the preparation of supported catalysts. In this paper, the effects of ultrasonic treatment on the surface texture, oxygen groups of activated carbon (AC) as well as ruthenium dispersion were investigated by the employments of N(2) physisorption, TPD-MS and CO chemisorption respectively. It have been shown that ash content in AC can be effectively eliminated by ultrasonic pretreatment, at the same time, the BET surface area and total pore volume are reduced, and the amount of the decomposable surface oxygen groups are decreased. Furthermore the ash content decrease and the mesopore surface area increase with the ultrasonic power increasing. The activities of a series of barium-potassium-promoted Ru/AC catalysts for ammonia synthesis were tested at 10,000 h(-1), 10.0 MPa and 400 degrees C. The results show that the activities of Ru/AC catalysts which were prepared by ultrasonic treatment are greatly increased, and the optimum pretreatment power is 100 W. The ash content of this carbon support is decreased from 1.39% to 1.15%. As a result, the catalytic activity is improved from 65.3 to 83.8 mmol g(-1) h(-1).

Journal Article↗

Superimposed ultrasonic oscillations in compression tests of aluminium.

The application of ultrasonics in metal forming applications has been shown to reduce the forming load significantly in many research studies. The load reduction has been related to the stress superposition effect, rise in temperature and change in the friction condition between the specimen and die interfaces. This paper reports an investigation into the effects of superimposed ultrasonic oscillation of the die in compression tests on aluminium specimens. In particular, a finite element model is developed to simulate uniaxial compression and to model the effects of a change in the friction boundary condition when ultrasonic excitation is applied to the lower platen. The model predictions of the stress-strain relationship can be compared with test data to provide some insights into the effects of the interfacial condition. The paper shows how the analysis of the test data, combined with finite element models of ultrasonic compression test simulations, allows some initial conclusions to be drawn regarding the influence of the interfacial friction during ultrasonic compression.

Journal Article↗

Synergetic driving concepts for bundled miniature ultrasonic linear motors.

Rotary ultrasonic motors have found broad industrial application in camera lens drives and other systems. Linear ultrasonic motors in contrast have only found limited applications. The main reason for the limited range of application of these very attractive devices seems to be their small force and power range. Attempts to build linear ultrasonic motors for high forces and high power applications have not been truly successful yet. To achieve larger force and higher power, multiple miniaturized motors can be combined. This approach, however, is not as simple as it appears at first glance. The electromechanical behaviour of the individual motors differs slightly due to manufacturing and assembly tolerances. The individual motor characteristics are strongly dependent on the driving parameters (frequency, voltage, temperature, pre-stress, etc.) and the driven load and the collective behaviour of the swarm of motors is not just the linear superposition of the individual drive's forces. Thus, the bundle of motors has to be synchronized and controlled appropriately in order to obtain an optimized drive that is not oversized and costly. We have investigated driving and control strategies of a set of linear ultrasonic motors. Our contribution will be divided into three main parts. In part I ultrasonic linear motors will be introduced. In part II driving strategies for a single motor as well as for a bundle of motors will be presented. These concepts will be verified by simulation results and experimental data. In part III a simplified model for the motor's electromechanical behaviour will be given.

Journal Article↗

Ultrasonic effects on electroorganic processes. Part 25. Stereoselectivity control in cathodic debromination of stilbenedibromides.

Ultrasonic effects on the cathodic debromination of stilbenedibromides on a platinum cathode was examined. Current efficiency and stereoselectivity for trans-stilbene, which was formed along with cis-stilbene in the cathodic debromination of stilbenedibromides, were significantly increased under ultrasonication with an intensity over the ultrasonic cavitation threshold. This ultrasonic effect is rationalized as due to mass transport promotion in the electrode-electrolytic solution interface. A mechanism for the ultrasonic effect is discussed in detail on the basis of the reaction pathway of the debromination of stilbenedibromides.

Bromides↗

The optimisation of ultrasonic cleaning procedures for dairy fouled ultrafiltration membranes.

Ultrafiltration (UF) of whey is a major membrane based process in the dairy industry. However, commercialization of this application has been limited by membrane fouling, which has a detrimental influence on the permeation rate. There are a number of different chemical and physical cleaning methods currently used for cleaning a fouled membrane. It has been suggested that the cleaning frequency and the severity of such cleaning procedures control the membrane lifetime. The development of an optimal cleaning strategy should therefore have a direct implication on the process economics. Recently, the use of ultrasound has attracted considerable interest as an alternative approach to the conventional methods. In the present study, we have studied the ultrasonic cleaning of polysulfone ultrafiltration membranes fouled with dairy whey solutions. The effects of a number of cleaning process parameters have been examined in the presence of ultrasound and results compared with the conventional operation. Experiments were conducted using a small single sheet membrane unit that was immersed totally within an ultrasonic bath. Results show that ultrasonic cleaning improves the cleaning efficiency under all experimental conditions. The ultrasonic effect is more significant in the absence of surfactant, but is less influenced by temperature and transmembrane pressure. Our results suggest that the ultrasonic energy acts primarily by increasing the turbulence within the cleaning solution.

Animals↗

Ultrasonic dehalogenation and toxicity reduction of trichlorophenol.

The study focussed on the effect of ultrasonic frequency and co-pollutants on dechlorination and toxicity reduction of a toxic model pollutant, i.e. 2,3,5-trichlorophenol (TCP). The effect of ultrasonic frequency on TCP degradation and chloride formation was studied at 41, 206, 360, 618, 1068, and 3217 kHz. Most efficient ultrasonic dechlorination was achieved at 360 kHz. The degradation of TCP and adsorbable organic halogens followed pseudo-first-order rate kinetics. Toxicity in the bioluminescence test increased during the initial sonication period, indicating the temporary formation of more toxic reaction products. Subsequently, toxicity was significantly reduced. Dehalogenation efficiency decreased in the presence of the hydrophobic radical scavenger t-butanol, whereas hydrophilic co-pollutants such as acetate or glucose did not interfere with ultrasonic dechlorination and toxicity reduction. After ultrasonic pre-treatment, a fast biodegradation of the remaining organic pollutants was observed. In conclusion, the results demonstrate the potential of integrated ultrasonic/biological approaches for the treatment of wastewaters containing toxic pollutants.

Halogens↗

Ultrasonic effects on electroorganic processes. Part 27. Electroreduction of acrylonitrile at suspended lead particle-electrode.

Ultrasonic effect on the electroreduction of acrylonitrile at suspended lead particle-electrode was examined. The product selectivity for adiponitrile, which was formed as the corresponding hydrodimeric product along with propionitrile as the hydromonomeric one in the cathodic reduction of acrylonitrile, was increased by addition of lead particles as a particle-electrode, and moreover the selectivity was further increased under ultrasonication. This ultrasonic effect is rationalized as due to not only mass transport of lead particles to the feeder cathode but also an increase in the effective surface area of particle-electrode by ultrasonic dispersion. A mechanism for the ultrasonic effect is discussed in detail on the basis of the reaction system.

Acrylonitrile↗

Study of ultrasonic melt treatment on the quality of horizontal continuously cast Al-1%Si alloy.

The fluctuation of the melt temperature in a tundish was measured during casting and experiments were conducted to investigate the effects of ultrasonic melt treatment on the surface quality and solidification structures of Al-1%Si ingots. The results show that the uniformity of melt temperature was enhanced with the application of ultrasonic melt treatment. When the ultrasonic power is 1,000W, the surface quality was evidently improved and grains of cast ingots were refined. Moreover, EPMA analysis was adopted to study the relationship between the ultrasonic power and boundary segregation of Si element. The result shows that boundary segregation is suppressed with the increase of ultrasonic power and the phenomenon was theoretically interpreted.

Journal Article↗

Influence of ultrasonic waves in the reduction of nitrate to nitrite by hydrazine-Cu(II).

Colorimetric methods are still important for determining nitrate and nitrite. A critical step in the use of these methods to determine nitrate in low concentrations is the reaction time required to totally reduce nitrate to nitrite, i.e., 24h in the dark. This work involved a study of the influence of ultrasonic irradiation on the nitrate reduction reaction by hydrazine. Our findings indicated that ultrasonic irradiation, associated with copper(II) ion as a catalyst, increased the redox reaction rate, decreasing the reaction time to about 10min when the power of the ultrasonic irradiation was set in 14.0357W. The strong influence of the ultrasonic irradiation in the reduction reaction rates can be sustained by an excellent linear correlation (R(2)=0.9993) between the kinetic constants and ultrasonic powers. Nitrate conversion also increased from 68% to 98% at the latter conditions. It thus become clear that high intensity ultrasound is very beneficial for this reduction reaction to proceed in good yield and in short reaction time in comparison to its silent reaction.

Journal Article↗

Follicular aspiration: a comparison of an ultrasonic endovaginal transducer with fixed needle guide and other retrieval methods.

Ultrasonic techniques have been developed as alternatives to conventional laparoscopic aspiration for oocyte retrieval for in vitro fertilization (IVF). Given the advantages (less risk, lower cost, and greater patient acceptance) of these alternative techniques, it is appropriate to assess their efficacy compared with traditional laparoscopic retrieval. This article examines the recovery rate of oocytes and their subsequent fertilization rate with the use of an ultrasonic endovaginal transducer with fixed needle guide and compares these results with other retrieval methods. Comparisons were made between laparoscopic harvesting (n = 71, group I), ultrasonic transabdominal transvesical (n = 21, group II), and ultrasonic vaginal transducer (n = 76, group III). The data demonstrate comparable success using an ultrasonic endovaginal transducer with fixed needle guide. The authors believe this technique to be the procedure of choice for all routine oocyte retrievals during IVF treatment.

Female↗

Ultrasonic lithotripsy: the risk of hearing loss.

Ultrasonic lithotripsy has been applied widely to the percutaneous removal of upper tract calculi. The high noise levels generated by ultrasonic lithotriptors during clinical use have raised some concern among endourologists. In this study sound level measurements of all 3 commercially available ultrasonic lithotriptors were obtained in the audiology laboratory and operating room. In all circumstances the maximum noise levels recorded (103 dBA. or less) for the time of exposure that would be encountered in the clinical setting of ultrasonic lithotripsy never exceeded safe levels. We concluded that the routine use of ultrasonic lithotriptors does not present a hazard to the hearing of normal individuals.

Audiometry↗

Correlations to predict droplet size in ultrasonic atomisation.

In conventional two fluid nozzles, the high velocity air imparts its energy to the liquid and disrupts the liquid sheet into droplets. If the energy for liquid sheet fragmentation can be supplied by the use of ultrasonic energy, finer droplets with high sphericity and uniform size distribution can be achieved. The other advantage of ultrasound induced atomisation process is the lower momentum associated with ejected droplets compared to the momentum carried by the droplets formed using conventional nozzles. This has advantage in coating and granulation processes. An ultrasonic probe sonicator was designed with a facility for liquid feed arrangement and was used to atomise the liquid into droplets. An ingenious method of droplet measurement was attempted by capturing the droplets on a filter paper (size variation with regard to wicking was uniform in all cases) and these are subjected to image analysis to obtain the droplet sizes. This procedure was evaluated by high-speed photography of droplets ejected at one particular experimental condition and these were image analysed. The correlations proposed in the literature to predict droplet sizes using ultrasound do not take into account all the relevant parameters. In this work, a truly universal correlation is proposed which accounts for the effects of physico-chemical properties of the liquid (flow rate, viscosity, density and surface tension), and ultrasonic properties like amplitude, frequency and the area of vibrating surface. The significant contribution of this work is to define dimensionless numbers incorporating ultrasonic parameters, taking cue from the conventional numbers that define the significance of different forces involved in droplet formation. The universal correlations proposed are robust and can be used for designing ultrasonic atomisers for different applications. Among the correlations proposed here, those ones that are based on the dimensionless numbers and Davies approach predict droplet sizes within acceptable limits of deviation. Also, an empirical correlation from experimental data has been proposed in this work.

Humans↗

Internal tissue displacement measurement based on ultrasonic wave Doppler signal digital detection and its application to fetal movement monitoring.

We have developed a fetal movement monitoring system based on small displacement measurement of internal tissues. When ultrasonic pulses are transmitted to the fetus, the reflected ultrasonic waves which have a Doppler frequency shift due to the fetal movements are detected by using an ultrasonic pulsed Doppler technique. In this paper, we propose a displacement measurement method for internal tissues which is based on the Doppler signal digital detection technique. In the method, the received ultrasonic RF signals are sampled with a sampling frequency of four times higher than the centre frequency of the ultrasonic waves; the Doppler frequency shift signals are derived using digital signal processing. From the detected signals, the internal displacements are estimated using the arc-tangent method. The basic algorithm of the detection method has already been used in the area of blood flow sensing, however, we apply the algorithm to the displacement measurement of internal tissues. The comparison between the proposed method and the conventional method is presented. The fetal movement quantitative monitoring system based on the method which has been constructed is shown.

Algorithms↗

Ultrasonic actuators for nanometre positioning

This paper deals with ultrasonic motors based on bimodal plate vibrations and their application to nanometre resolution stepper positioning systems. The concept of a linear ultrasonic motor drive capable of nanometric steps, long-range travel and reversible controlled motion is presented. The motor concept developed is based on the superposition of a longitudinal and bending vibrations of a rectangular resonator. The ultrasonic motor model based on system identification via discrete observations and prediction has been developed for control applications. The control algorithm for ultrasonic motors has been developed and theoretical investigations have been made. The open loop positioning system with designed stepper ultrasonic drive produced 10 nm resolution and 5% displacement repeatability. The system with computer controlled position feedback has shown 0.3 micron positioning accuracy over the 100 mm positioning range.

Journal Article↗

Role of pups' ultrasonic calls in a particular maternal behavior in Wistar rat: pups' anogenital licking.

Stimuli from pups maintain maternal behavior in the postpartum period. Olfactory cues are strongly involved in a particular component of maternal behavior: anogenital licking (MAGL). In addition to the olfactive stimulus, ultrasonic calls from pups are critical in ensuring pup survival. Pups emit vocalizations in distress situations. In a first experiment, pups' calls are recorded around MAGL sequences. In 2 out of 3 cases these calls appear to induce MAGL behavior from the dam with preputialectomised pups as well as with intact pups, but preputialectomised pups alone call again at the end of MAGL sequences. In a second experiment, ultrasonic calls from pups emitted just before AGL sequences were recorded and played back to dams in a glass-dish selection test. Whatever the pups' treatment (preputialectomised or sham), dams showed the specific ingestive behavior towards filter paper impregnated with dodecyl propionate (DP) when auditory cues (pups' ultrasonic calls) and olfactory cues (DP) were combined. The coordination of pups' ultrasonic calls and anogenital odor in MAGL behavior is discussed, ultrasonic calls might be an inducing factor and DP the regulating factor.

Animals↗

Ultrasonic measurement of enamel thickness: a tool for monitoring dental erosion?

OBJECTIVES: Wear of dental hard tissues, e.g. dental erosion, is reported to be a growing problem. A non-destructive measurement of enamel layer thickness would provide the opportunity for both early diagnosis, and longitudinal measurement of progressive enamel loss. It was the aim of this study to investigate the potential of ultrasonic pulse-echo measurements for the enamel thickness measurement. METHODS: Nine extracted human incisor teeth were selected and stored in physiological saline. Mesial and distal tooth parts were removed, resulting in a central tooth slice of about 2 mm thickness. Where possible three buccal, and one palatal measuring sites were selected and indicated by pencil marks on one of the section planes. Ultrasonic pulse-echo measurements were made at each site using a Panametrics 25DL thickness gauge (Panametrics, Waltham, MA, USA), using a perspex delay line transducer (15 MHz) and glycerine coupling medium. Ultrasonic measurements were validated by measuring the thickness of the enamel layer at the marked side of the tooth slices with a light stereomicroscope at 120 x magnification. Two observers performed independent measurements. RESULTS: Limits of agreement for measurements by two observers (n = 42) were -0.09 and 0.09 mm. Measurements performed at 21 degrees C and 34 degrees C were not significantly different, as analysed by paired Student's t-test (p = 0.19). Pearson's correlation coefficient between ultrasonic and microscopic measurements was 0.90. Analysis of all measurements from both observers at both temperatures yielded a sound velocity in enamel of 6.5 x 10(3) m/s (standard error 0.1 x 10(3) m/s). CONCLUSIONS: It was concluded that the ultrasonic measurement of the enamel thickness is feasible without enamel preparation.

Dental Enamel↗

Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Shear wave elasticity imaging (SWEI) is a new approach to imaging and characterizing tissue structures based on the use of shear acoustic waves remotely induced by the radiation force of a focused ultrasonic beam. SWEI provides the physician with a virtual "finger" to probe the elasticity of the internal regions of the body. In SWEI, compared to other approaches in elasticity imaging, the induced strain in the tissue can be highly localized, because the remotely induced shear waves are attenuated fully within a very limited area of tissue in the vicinity of the focal point of a focused ultrasound beam. SWEI may add a new quality to conventional ultrasonic imaging or magnetic resonance imaging. Adding shear elasticity data ("palpation information") by superimposing color-coded elasticity data over ultrasonic or magnetic resonance images may enable better differentiation of tissues and further enhance diagnosis. This article presents a physical and mathematical basis of SWEI with some experimental results of pilot studies proving feasibility of this new ultrasonic technology. A theoretical model of shear oscillations in soft biological tissue remotely induced by the radiation force of focused ultrasound is described. Experimental studies based on optical and magnetic resonance imaging detection of these shear waves are presented. Recorded spatial and temporal profiles of propagating shear waves fully confirm the results of mathematical modeling. Finally, the safety of the SWEI method is discussed, and it is shown that typical ultrasonic exposure of SWEI is significantly below the threshold of damaging effects of focused ultrasound.

Acoustics↗

Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry.

PURPOSE: To compare central corneal thickness measurements taken with 3 pachymetry systems: Orbscan scanning-slit corneal topography/pachymetry, Topcon SP2000P noncontact specular microscopy, and Tomey ultrasonic pachymetry. SETTING: Multicenter study, Tokyo, Japan. METHODS: In 216 healthy eyes of 114 subjects, scanning-slit topography, noncontact specular microscopy, and ultrasonic pachymetry were used in that sequence to record central corneal thickness. In another 20 healthy eyes of 13 subjects, 2 sets of measurements were repeated for each pachymetry to assess repeatability. RESULTS: The mean central corneal thickness was compatible between scanning-slit topography (546.9 micrometers +/- 35.4 [SD] ) and ultrasonic pachymetry (548.1 +/- 33.0 micrometers); however, noncontact specular microscopy gave a significantly smaller mean (525.3 +/- 31.4 micrometers) than the other 2 tests (P<.001, Tukey multiple comparison). There were significant linear correlations between scanning-slit topography and noncontact specular microscopy (r = 0.846, P<.001), noncontact specular microscopy and ultrasonic pachymetry (r = 0.897, P<.001), and ultrasonic pachymetry and scanning-slit topography (r = 0.852, P<.001). Noncontact specular microscopy tended to show the best repeatability; however, the difference was not statistically significant (P =.663, repeated-measure analysis of variance). CONCLUSIONS: Corneal thickness readings were comparable between scanning-slit topography and pachymetry; noncontact specular microscopy gave significantly smaller values. The measurements of the 3 methods showed significant linear correlations with one another. All methods provided acceptable repeatability of measurements.

Adult↗