Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SILICATE CEMENT”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Changes in translucency and color of particulate filler composite resins.

PURPOSE: The purpose of this study was to examine changes in translucency and color of particulate filler composite resins that can be fabricated into metal-free crowns. MATERIALS AND METHODS: Eight types of materials were used in this study. The particulate filler composite resins were represented by Artglass, BelleGlass, Estenia, Gradia, and Targis. Herculite XRV and Solidex were the conventional composite resins for crowns and fixed partial denture facings, and Empress was the ceramic material. Disks with a thickness of 1.0 mm were fabricated from each material and subjected to an accelerated test by immersion in 60 degrees C distilled water for up to 8 weeks. Color measurements were made before and after water immersion. Changes in translucency were evaluated by determining the contrast ratio, and changes in color were evaluated by determining color difference. RESULTS: After water immersion, Targis and Solidex demonstrated a significant increase in contrast ratio (6% to 7%) and a decrease in translucency. A color difference of more than 2.0, a visually perceptible value, was found for Targis, Gradia, and Solidex. However, the maximum color difference for these was 3.0, a value that would be considered clinically acceptable. CONCLUSION: Within the limitations of this study, the particulate filler composite resins were stable in both translucency and color.

Aluminum Silicates↗

Fracture toughness of aged dental composites in combined mode I and mode II loading.

Resin-based laboratory dental composites for prosthetic restorations have been developed in the past years as a cost-effective alternative to conventional porcelain-fused-to-metal or full ceramic restorations. The fracture toughness at different stress states (K(Ic), K(IIc), and mixed-modes K(I), K(II) ) was assessed for three laboratory dental composite resins used for prosthetic restorations that were aged up to 12 months in a food simulating fluid (10% ethanol) at 37 degrees C. The materials were mainly di- methacrylate based resins reinforced with submicron glass filler particles. The Brazilian disk test was used on precracked chevron-notched specimens, and different stress states were obtained by angulating the precracked chevron notch relative to the diametral compressive loading direction. The stress intensity factors were calculated using Atkinson et al.'s relation. For all three materials, mode I fracture toughness values ranged between 0.48-0.64 MPa. m(0.5) and mode II values ranged between 0.93-1.2 MPa. m(0.5). Overall, aging time and storage media had little effect on toughness. Considering the inherently low toughness of these restorative materials, their use should be limited to low stress masticatory areas.

Aluminum Oxide↗

Mechanical behavior of glass ionomer cements affected by long-term storage in water.

OBJECTIVES: The early strength of glass ionomer cements was investigated previously (Cattani et al., 1993). Using the same set of glass ionomer cements, this study was designed to determine if mechanical property degradation occurred after an extended period of storage in water. METHODS: In the present study, the effect of aging in water on the compressive, tensile and flexural strengths of twelve commercial glass ionomer cements was evaluated at different time intervals after the beginning of the setting reaction. The aging periods varied from 24 h to 12 mon. RESULTS: The results show that the mechanical properties of the tested materials are in some cases affected by long-term aging in water. The evolution of strength follows distinct patterns of change. It has been established that the glass ionomer cements are neither characterized by a continuous increase nor a continuous decrease in strength. Most of the materials tested maintained a constant strength. However, several of them first display an improvement of the mechanical strength followed by a reduction. In this case, the 24h and the 12 mon strengths are usually similar. SIGNIFICANCE: The aging mechanisms of glass ionomers are complex. Strengthening probably results from additional crosslinking and build-up of a silica gel phase, whereas weakening may result from erosion and plasticizing effect of water.

Acrylic Resins↗

The bonding of an adhesive resin cement to single and combined adherends encountered in resin-bonded bridge work: an in vitro study.

Although resin-bonded bridges should ideally be bonded to enamel, abutment teeth may present with dentine or restorations at the bonding sites. This study assessed the influence of bonding to such adherends on bridge retention by using tensile bond strength measurements as the criteria for judgement. An adhesive resin cement (Panavia Ex) was bonded to single adherends of enamel, dentine, composite resin, glass ionomer or amalgam, and to combined adherends of enamel/dentine or enamel/restorative material. The bond strength to enamel (28 MPa) was comparable with that to composite resin (25 MPa), but significantly higher than to dentine (8 MPa), amalgam (8 MPa) and glass ionomer (13 MPa). When the bonding area was half enamel and half restorative material, the bond strength was only equivalent to that obtained when the entire bonding area consisted of restorative material, the less favourable adherend. A similar trend was observed with specimens of enamel/dentine. This indicated that the magnitude of the bond between the resin cement and combined adherends was limited by the strength of the bond to the less favourable adherend. It appears that extending a bridge retainer to cover exposed dentine, a glass-ionomer filling or an amalgam filling, could adversely affect the bridge retention.

Acrylic Resins↗

The survival and clinical performance of resin-based composite restorations used to treat localised anterior tooth wear.

OBJECTIVE: To examine the clinical performance of resin-based composite restorations placed at an increased vertical dimension when used to manage localised anterior tooth wear. DESIGN: A retrospective analysis of cases treated at a single centre. SETTING: UK Hospital setting in the year 2000. SUBJECTS AND METHODS: Two hundred and twenty five restorations placed in 31 subjects were included. Assessment was made following examination of study casts and projected slides. Modified United States Public Health Services criteria were used and data analysed using the software Statistical Programme for Social Sciences (SPSS). Survival analysis was carried out at two levels, major failure only and all types of failure. Kaplan-Meier survival plots were produced against different variables and modes of failure were also noted. RESULTS: Major failure requiring replacement of the restoration was uncommon within the first five years. Minor failure requiring repair or refinishing presented mainly as wear, marginal discolouration or marginal fracture. Median survival was 4 years 9 months when all types of failure were considered. The restorations have good appearance and are well tolerated. CONCLUSION: Placement of resin-based composite restorations at an increased vertical dimension to treat localised anterior tooth wear, has good short to medium term survival. The technique is conservative and relatively easy to maintain.

Adolescent↗

Finishing and polishing of the ceromer material Targis. Lab-side and chair-side methods.

UNLABELLED: The aim of the study was to check four lab-side and four chair-side methods for finishing and polishing the ceromer material Targis. Eighty bar-shaped specimens (20 mm x 10 mm x 2 mm) of Vectris were produced; 72 were covered with a 2 mm (thickness) layer of the Ceromer Targis and eight samples with the composite Tetric. All specimens were ground plane parallel with 320 Silicium carbide grit sandpaper in order to start with the same level of roughness. Then the specimens were finished and polished using the following methods: (1) Artglass toolkit, (2) pumice-stone and brushes/linen brush and polishing paste P3, (3) Robinson brush/Ivoclar Universal paste and wool brush, (4) Silicone wheel and rag wheel, (5) Shofu Rainbow set, (6) Sof-Lex discs, (7) Vivadent Politip set and (8) Nupro-pastes and brushes. The surface roughness was determined with a profilometer. The arithmetical roughness value Ra was calculated. From each group one specimen was randomly chosen and sputtered with gold in order to observe the surface with a scanning electron microscope to evaluate its smoothness. The methods were ranked as followed: 2, 3 and 5 with the lowest roughness, then 8, 6, 7, 4, 1. The best ranked chair-side method (5) and the best ranked lab-side methods (2, 3) did not differ significantly between the Ra values. No difference was observed between the composite Tetric and the ceromer Targis when these materials were polished using the same method. CONCLUSION: the lab-side-methods 2 and 3 and the chair-side-method 5 can be recommended for finishing and polishing the new ceromer material Targis.

Carbon Compounds, Inorganic↗

Translucency of glass-fibre-reinforced composite materials.

summary The purpose of this study was to examine the translucency of glass-fibre-reinforced composite framework materials. Vectris and FibreKor, as well as an experimental material, were the glass-fibre-reinforced framework materials used. Targis, Sculpture and Estenia were the types of particulate filler composites veneered onto frameworks. Specimens were fabricated from each material, 0.5 and 1.0 mm thick. In addition, laminate specimens, 1.5 mm thick, were fabricated. The translucency of each specimen was evaluated by determining its contrast ratio. The laminate specimens were examined for colour differences. The experimental framework material was more translucent than the enamel composite when it was not coloured, and was nearly as translucent as the dentine composite when coloured. The commercial tooth-coloured framework materials were nearly as translucent as the dentine composite. It was found that it was possible to reproduce the same colour as the veneering dentine composite, when the framework thickness was 0.5 mm, except in the case of FibreKor. Within the limitations of this study, tooth-coloured, glass-fibre-reinforced framework materials are nearly as translucent as the veneering dentine composite, but these materials affect the colour of the prosthesis if the thickness of the framework material is increased beyond a certain point.

Composite Resins↗

Application of Heatless Glass as a coating material for denture base-evaluation of denture retentive force.

Heatless Glass (HG) was applied to the basal surface of dentures as a coating material. To evaluate the influence of this material on the retentive force of the dentures, the adhesive force of pairs of resin specimens (heat curing resin), metal specimens (Co-Cr alloy), and HG metal specimens (Co-Cr alloy coated with HG), using tap water or resting saliva as a medium was measured, and the following results were obtained. (i) The adhesive force of metal specimens coated with HG material was significantly larger (by 2.3-2.6 times) than that of resin materials (P < 0.001), and it was slightly lower (0.8-0.9 times) than that of metal specimens, showing no significant difference (P > 0.10). (ii) The adhesive force of specimens using tap water as a medium was approximately one-half to two-third of that of specimens using resting saliva as a medium. (iii) When resting saliva was used as the medium, the maximum difference in the adhesive force of the specimens among subjects was 1.7 times. (iv) These findings suggested that, from the perspective of adhesive force, HG coating material is suitable for application to the basal surface of dentures.

Adhesives↗

Short-term stress-relaxation behavior of nonmetallic restoratives.

The rheological behavior of five nonmetallic dental materials was studied. Short-term stress relaxation was found to be strongly dependent on time and temperature. Relaxation behavior of the test materials conformed well to simple mathematical models.

Dental Cements↗

Finite element analysis of fiber-reinforced fixed partial dentures.

Two-dimensional finite element models were created for a three-unit posterior fixed partial denture. An experimental resin-impregnated glass fiber was used as the fiber-reinforced composite (FRC) for the framework. The FRC was evaluated using varying combinations of position and thickness, alongside with two types of veneering composite. A load of 50 N simulating bite force was applied at the pontic in a vertical direction. Tensile stress was examined using a finite element analysis program. Model without FRC showed tensile stress concentrations within the veneering composite on the cervical side of the pontic--from the connector area to the bottom of the pontic. Model with FRC at the top of the pontic had almost the same stress distribution as the model without FRC. Models with 0.4-0.8 mm thick FRC positioned at the bottom of the pontic showed maximum tensile stresses reduced by 4-19% within the veneering composite.

Bite Force↗

[Study on dental cement. Part 4. Protective effect of a newly designed light-cured varnish on the vulnerability to water of glass polyalkenoate cement restorations].

The protective effect of a newly designed light-cured varnish on the vulnerability to water of two kinds of glass polyalkenoate cement restorations was examined by determining the penetration depth of Ag ion into the set cement on the SEM pictures in comparison with those of the conventional varnish and a light-cured resin bonding agent. The protective effect of the experimental light-cured varnish was perfect, while those of the conventional varnish and the light-cured resin bonding agent were inferior to that.

Dental Cavity Lining↗