Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radius”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Thrombocytopenia with absent radius (TAR).

Forty examples (27 from the literature and 13 new cases) of a syndrome of hypomegakaryocytic thrombocytopenia with bilateral absence of the radius have been analyzed. This syndrome is designated in this paper as "thrombocytopenia with absent radius (TAR)". The onset of hematologic complications usually occurs at birth or during early infancy. Thrombocytopenia may be episodic and sometimes is accompanied by leukemoid reactions and eosinophilia. Bone marrow examination reveals decreased and/or abnormal megakaryocytes, with normal myeloid and erythroid precursors. Congenital skeletal deformities include bilateral absence of radius, shortening and deformity of the ulnae, and occasionally absence of all the long bones in the arm. The fingers and thumbs are always present. Other skeletal anomalies are frequent. Cardiac anomalies, particularly the tetralogy of Fallot and atrial septal defects, may be present. Other non-skeletal congenital abnormalities are rare. The prognosis is good if the patient survives to one year of age. The syndrome has been compared to Fanconi's anemia, thalidomide embryopathy, limb-cardiovascular syndrome, and a syndrome of multiple congenital malformations, from which it can be distinguished.

Abnormalities, Multiple↗

Extensive distal subcutaneous metastases of a "benign" giant cell tumor of the radius.

A case of distant metastases of a giant cell tumor of the radius is presented. The tumor within the radius was excised, followed by arthrodesis of the wrist and bone grafting with tibia. At the time she came to us, the patient presented distal dissemination, so we performed curettage of each one of the multiple metastases of soft tissues of the hand. After 9 months, a local recurrence in the radius was resected, and reconstruction was done with a vascularized graft of fibula. Later treatment consisted of intraarterial chemotherapy. The patient is in satisfactory condition 1 year after surgery.

Adult↗

Vascularized fibular graft after excision of giant-cell tumor of the distal radius: wrist arthroplasty versus partial wrist arthrodesis.

Several reconstructive procedures have been described for the complete defect of the distal radius that is created after a wide excision of a giant-cell tumor of bone, including hemiarthroplasty using the vascularized fibular head and partial wrist arthrodesis between a vascularized fibula and the scapholunate portion of the proximal carpal row. The objectives of this study are to compare clinical and radiographic results between the partial wrist arthrodesis and the wrist arthroplasty, and to discuss which procedure is superior. Four patients with giant-cell tumors involving the distal end of the radius were treated with en bloc resection and reconstruction with a free vascularized fibular graft. The wrists in two patients were reconstructed with an articular fibular head graft and the remaining two patients underwent partial wrist arthrodesis using a fibular shaft transfer. There was radiographic evidence of bone union at the host-graft junctions in all cases. In the newly reconstructed wrist joint, there was palmar subluxation of the carpal bones and degenerative changes in both patients. Local recurrence was seen in one patient. According to the functional results described by Enneking et al., the mean functional score was 67 percent. The functional scores including wrist/forearm range of motion in the cases with partial wrist arthrodesis were superior to those with wrist arthroplasty. A partial wrist arthrodesis using a vascularized fibular shaft graft appears a more useful and reliable procedure for reconstruction of the wrist after excision of the giant-cell tumor of the distal end of the radius than a wrist arthroplasty using the vascularized fibular head, although our study includes only a small number of patients.

Adult↗

Treatment of the neglected distal radius fracture.

Operative treatment of inadequately or imperfectly treated fractures of the distal radius can improve wrist and hand function substantially, but rarely restores the limb to normal. Patients with malunion of the distal radius present either with poor radiographic alignment before complete healing of the fracture (nascent malunion) or with functional problems that may be related to inadequate alignment of a healed fracture (mature malunion). Corrective osteotomy is offered to patients who have sufficient malalignment that the surgeon thinks problems are inevitable or to patients in whom the functional deficit can be related clearly to the malunion. Ununited fractures are associated with painful instability of the wrist and very poor hand function. Operative treatment has proved successful even when the distal fragment is small. Operative treatment for reconstruction of the distal radius has been facilitated by the introduction of plates with angular stable screws (screws that lock into the plate). Painful arthritis is salvaged with arthrodesis.

Arthritis↗

External fixation techniques for distal radius fractures.

UNLABELLED: Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. LEVEL OF EVIDENCE: Level V (expert opinion).

Aftercare↗

The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model.

OBJECTIVE: The purpose of this cadaveric study was to compare the mechanical behavior of a locked compression plate, which uses threaded screw heads to create a fixed angle construct, with a dynamic compression plate construct in a cadaver radius model. DESIGN: Mechanical study with cyclic testing and high-speed optical motion analysis. SETTING: Biomechanics laboratory at an academic institution. PATIENTS/PARTICIPANTS: Eighteen pairs of fresh-frozen human cadaver radii were divided into 3 groups of 6 to be tested as a group in each of the following force applications: anteroposterior (AP) bending, mediolateral bending, or torsion. INTERVENTION: Each bone was osteotomized leaving a 5-mm fracture gap and then fixed with a plate. For each pair, 1 radius received a standard plate (limited-contact dynamic compression plates; LC-DCP), the contralateral radius was fixed with a locking compression plate (LCP), and specimens underwent cyclic loading. Normalized stiffness, average energy absorbed, and Newton-cycles to failure were calculated. In addition, a 3-dimensional, high-speed, infrared motion analysis system was used to evaluate motion at the fracture site. MAIN OUTCOME MEASUREMENTS: Construct stiffness, fracture site motion, cycles to failure, and energy absorption. Repeated measures ANOVA were used to detect differences between groups with time. RESULTS: In the torsion group, LCP specimens failed at 60% greater Newton-cycles than the LC-DCP (1473 vs. 918; P < 0.05). In the AP group, the LC-DCP absorbed significantly greater energy during 10,000 cycles compared with the LCP group (P < 0.05). The 2 constructs demonstrated different biomechanical behavior with time. As cycling progressed in the LC-DCP specimens under torsion testing, stiffness (measured at the actuator at the bone ends) did not change significantly; however, fracture motion (measured at the fracture surfaces) decreased significantly (P = 0.04). The LCP specimens did not display similar behavior. CONCLUSIONS: Our findings indicated that LCP constructs may demonstrate subtle mechanical superiority compared with the LC-DCP. The LCP specimens had less energy absorption in the AP group and survived longer in the torsion group. Discordance of motion between measurement regions was observed only in the LC-DCP torsion group, and may have been caused by plate-bone slippage or bone-screw subcatastrophic failure. However, many other compared parameters were found to be similar, and the clinical significance of the few differences found between constructs mandates further investigation.

Biomechanical Phenomena↗

A randomized, controlled trial of distal radius fractures with metaphyseal displacement but without joint incongruity: closed reduction and casting versus closed reduction, spanning external fixation, and optional percutaneous K-wires.

OBJECTIVES: To compare closed reduction and casting with closed reduction and external fixation with optional K-wire fixation for distal radius fractures with metaphyseal displacement but without joint incongruity. DESIGN: Prospective study. SETTING: Multicenter study at 3 University teaching hospitals. PATIENTS/PARTICIPANTS: A total of 113 skeletally mature patients with distal radius fractures with metaphyseal displacement, but without joint incongruity, were randomized to receive 1 of 2 standardized treatment protocols. Patients were evaluated at 6 weeks, 6 months, 1 year, and 2 years. INTERVENTION: Closed reduction and casting (n = 59) or closed reduction and external fixation (n = 54). MAIN OUTCOME MEASUREMENTS: Upper extremity function was measured using upper extremity MFA domain scores, overall Jebsen Taylor scores, and pinch and grip strength tests. Global function and pain were measured using the SF-36. Radiographic evaluation and range of motion were documented. RESULTS: Upper extremity MFA scores, Jebsen Taylor scores, SF-36 bodily pain scores, and grip strength improved significantly during the first year for all patients. By 2 years, mean Jebsen Taylor scores and SF 36 bodily pain scores for patients in both groups were similar to scores for normal age- and gender-matched population controls. At all points, there was a trend for better function in the external fixation; however, this did not reach statistical significance. There was a trend for better length and palmar tilt restoration with external fixation. CONCLUSIONS: For distal radius fractures with metaphyseal displacement but with a congruous joint, there exists a trend for better functional, clinical, and radiographic outcomes when treated by immediate external fixation and optional K-wire fixation.

Adult↗

Radiographic assessment of pediatric proximal radius fractures: interrater and intrarater reliability.

Three methods of measuring pediatric proximal radius fracture radiographs were compared using injury films of 32 patients. Angulation and displacement were independently measured by four physicians. One physician measured the films by each method a second time 2 months later. Values for interrater and intrarater reliability were determined using inter- and intra-class coefficients (ICC). Interrater reliability was poor for methods using the axis of the proximal radial fragment or the proximal radial physis as a reference (ICC = 0.47 and 0.42, respectively). Measurement of the angle between a line parallel to the proximal radius articular surface and the radial shaft had the highest interrater reliability (0.76); measurement of displacement had the lowest interrater reliability (0.09). The intrarater reliability was excellent for all methods (0.93-0.99) and was also highest when the proximal articular surface reference was used. Of described methods, use of the proximal radius articular surface and the radial shaft as references had the highest interrater and intrarater reliability.

Adolescent↗

Simultaneous radial closing wedge and ulnar shortening osteotomy for distal radius malunion.

Closing wedge osteotomies are an attractive treatment option for distal radius malunion in patients with osteopenia. It does not require a separate-site bone graft, result-ing in decreased morbidity. However, this procedure has always been performed in combination with ulnar head resection to accommodate closure of corrective osteotomy and to address the issue of ulnocarpal abutment. Because ulnar shortening osteotomy is more physiological solution, it seemed advantageous to us to combine radial closing wedge osteotomy and ulnar shortening osteotomy. In this article, we present in detail our technique for treating patients with distal radius malunion. The patients are potentially osteopenic such as women aged over 45 years and are active at home, work, and/or recreation but are not involved in heavy physical work. Through volar approach an appropriate bone wedge is removed from the distal radius. A small volar T-plate is used to secure the osteotomized bone fragments. The aim of the radial osteotomy is to correct the dorsal angulation in the sagittal plane within a normal range of 1 degree to 2 degrees with reference to that of opposite wrist. Ulnar shortening osteotomy is performed by using transverse osteotomy and compression plating technique with an AO compression device. The ulnar variance is adjusted to neutral. Although the technique presented requires the surgeons to use careful plate and screw technique, early results have been encouraging, and patients with osteopenia can be treated successfully. Decreased grip strength which may be provoked by shorting of the forearm is acceptable.

Colles' Fracture↗

Distal radius fracture fixation with an intramedullary nail.

The purpose of this article is to describe a novel technique and implant system for fixation of unstable (Arbeitsgemeinschat fur Osteosynthesesfragen Types A and B) distal radius fractures. Currently the most common complications directly related to distal radius plate fixation includes tenosynovitis, tendon attrition, and rupture, often necessitating hardware removal. With the advent of this new device, a decrease in soft tissue complication is expected. The implant utilizes the principles of load sharing, subchondral screw divergence, and locked fixed-angle fixation. It is inserted through a small skin incision at the radial styloid and does not further devascularize the fracture fragments. The limited surgical dissection and rigid fracture fixation allow for minimal postoperative immobilization and an early return of function. The authors believe that this system is a valuable addition to the arsenal of distal radius fracture treatment options and can quickly get patients back on the road of recovery.

Aged↗

A new modification of corrective osteotomy for treatment of distal radius malunion.

A new modification of corrective osteotomy for distal radius malunion, which minimizes the need for bone grafting and addresses the constraining aspect of the extensor retinaculum, is described. This new modification uses a volar and dorsal approach to perform an angled step-cut osteotomy, release of the extensor retinaculum, and volar plating. The typically dorsally extruded comminuted fracture fragments from the distal, dorsal compression fracture component of the distal radius fracture is mobilized with the distal fragment and acts as a dorsal strut graft to span the opening wedge, corrective osteotomy. Therefore, this new modification facilitates and improves the realignment of the malunited radius, while minimizing or eliminating the need for bone grafting.

Biomechanical Phenomena↗

Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.

RATIONALE AND OBJECTIVES: To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS: The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) with osteoporotic fractures. Measurements of SOS and bone mineral density (BMD) were carried out in all subjects. RESULTS: Intraobserver in vivo short-term precision was on average 0.76% for the radius, 0.47% for the tibia, and 1.54% for the phalanges. The interobserver precision ranged from 0.77% to 2.39%. Measurements of SOS at the 3 skeletal sites were significantly correlated (r = 0.28-0.44; P < 0.001). Significant correlations were found between SOS at all sites and BMD (r = 0.21-0.41; P < 0.001). The odds ratio for fracture prediction for SOS was 1.47 for tibia, 1.69 for radius, and 2.69 for phalanx. The corresponding odds ratios for BMD at the lumbar spine, femoral neck, and total hip ranged from 2.08 to 3.26. The area under the receiver operating characteristic curve ranged from 0.611 to 0.741 for SOS measurements and from 0.745 to 0.797 for BMD measurements. CONCLUSIONS: The Omnisense multisite QUS device exhibits reproducible performance. Among the QUS variables, the phalangeal SOS provides the best discrimination of fracture patients.

Aged↗

Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

RATIONALE AND OBJECTIVES: To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status. MATERIAL AND METHODS: High-resolution magnetic resonance images of the calcaneus and the distal radius and thin-section computed tomographic images of thoracic and lumbar vertebrae were obtained from 74 cadavers. Structure analysis was performed using parameters analogous to standard histomorphometry. BMD of the spine was determined by using quantitative computed tomography and of the calcaneus by using dual x-ray absorptiometry. Spine radiographs of these cadavers were assessed concerning vertebral deformities. RESULTS: The diagnostic performance in differentiating fracture and nonfracture subjects was highest for structure parameters in the spine and slightly lower for these parameters in the distal radius and for BMD of the spine. CONCLUSION: In this study structure parameters in the spine were best suited to predict the osteoporotic fracture status of the spine.

Absorptiometry, Photon↗

Use of an external fixation combined with the buttress-maintain pinning method in treating comminuted distal radius fractures in osteoporotic patients.

BACKGROUND: It is difficult to keep the alignment of a distal radius fracture in patients with osteoporosis and prevent malunion. Therefore, we hoped to design better method to maintain alignment. METHODS: Thirty-two patients over 65 years old with a displaced unstable distal radius fracture were treated by the external fixator combined with buttress-maintain pinning method and were compared with a group of 66 patients less than 60 years old treated by the same method. RESULT: The radiologic results demonstrated that postoperative and final radial length and volar tilt were not statistically different between both groups. The functional result (excellent and good) in the elderly group was 87.5% and 89% to that of the control group. There was only one complication of pin tract infection in the elderly group. CONCLUSIONS: External fixation for unstable distal radius fracture combined with buttress-maintain pinning method can be used in the osteoporotic bone of older adults with results similar to those for young adults at 18 months follow-up.

Adult↗

A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model.

BACKGROUND: This study compares the biomechanical stability of two volar locked plate systems for fixation of unstable, extra-articular distal radius fractures. METHODS: In six matched pairs of fresh frozen cadaveric specimens, a simulated unstable, extra-articular distal radius fracture was created. The fractures were stabilized with one of two types of volar locked plates. Specimens were axially loaded at five different positions: central, volar, dorsal, radial, and ulnar. Initial (precyclic loading) stiffness of each locked plate system was calculated. Each specimen was then loaded for 5,000 cycles with an 80 N central load. Finally, specimens were axially loaded at the same five positions to calculate the postcyclic loading stiffness of each volar locked plate system. Main outcome measurements were precyclic loading stiffness, postcyclic loading stiffness, maintenance of stiffness after cyclic loading, and amount of fracture displacement between the two volar locked plate systems. RESULTS: There were no differences in maintenance of stiffness and fracture displacement following cyclical loading between the two volar plate systems. After cyclic loading, the distal volar radius (DVR) locked plate was significantly stiffer than the Synthes volar locked plate in volar loading only (p < 0.01). CONCLUSION: Materials properties and design differences between these systems did not provide enough biomechanical difference to support use of either implant over the other. With this in vitro model, both implants provided adequate stability to resist physiologic loads expected during therapy in the initial postoperative period.

Adult↗

Late onset bone marrow failure associated with proximal fusion of radius and ulna: a new syndrome.

Members of two unrelated families, one from England and the other from Portugal, presented with aplastic anaemia. Both families had clinical and laboratory features in common. The proposita presented with progressive bone marrow failure in adult life involving all three haemopoietic cell lines. In both families individuals with bone marrow failure also had proximal fusion of the radius and ulna bilaterally which segregates as an autosomal dominant trait. No cytogenetic defect was identified in myeloid or lymphoid cells, sampled from the marrow and peripheral blood. Proximal fusion of the radius and ulna is uncommon and its co-existance with late onset bone marrow failure may indicate an association. Growth failure, non-skeletal congenital malformations and cytogenetic abnormalities were absent suggesting that this syndrome is distinct from Fanconi's anaemia. The onset in adult life of generalized bone marrow failure involving all three haemopoietic cell lines associated with proximal fusion of the radius and ulna also makes this syndrome distinct from the thrombocytopenia with absent radii (TAR) syndrome.

Adolescent↗

Clinical, haematological and radiological evaluation of fragmented autogenous cortical bone grafting of radius in dogs.

In eight clinically healthy dogs, a midshaft diaphyseal defect of 2 cm was created in the right radius ulna. This gap was maintained by fixing a four hole sherman bone plate on the radius. In four dogs, the gap was filled with autogenous cancellous bone grafts (2-5 mm in diameter) harvested from the proximal end of the tibia (group 1). In the remaining 4 dogs, the fracture gap was filled with autogenous cortical bone fragments (ACBF) of 2-5 mm diameter made from the same 2 cm piece of bone removed from the radius. While comparing various clinical observations, it appeared that healing of the wounds and bearing of the weight on the grafted limb in dogs subjected to ACBF graft were similar to those given autogenous cancellous bone graft. In radiographs, taken on the 30th day in group 1, a fairly good amount of callus was found emerging from fracture ends but the whole of the bone graft area was not covered by bony density even on the 60th day. In group 2 (ACBF), 45th day radiograph revealed that the callus from the fracture end was mixing up with the cortical bone fragments, and at the 60th day, the callus was clearly found invading the cortical bone fragments grafted in the fracture gap.

Animals↗

Hyperextension trauma to the elbow joint induced through the distal ulna or the distal radius: pathoanatomy and kinematics. An experimental study of the ligament injuries.

Loads applied to the forearm result in hyperextension of the elbow. The pathomechanics of hyperextension trauma with load applied to the distal radius and ulna were studied in 10 macroscopically normal cadaver elbow joint specimens to reveal patterns of injury with radial traction (n = 5) compared to ulnar traction (n = 5). The mean age of the donors was 60.8 years (range 33-74). Kinematic testing was performed in an experimental 3D-kinematic loading apparatus. The extension range of motion increased by 20.9 degrees +/- 2.9 degrees after joint loading. Hyperextension loads induced joint laxity during flexion of less than 60 degrees. In both groups, the changes were significant in joint flexion during forced valgus and external rotation, but were not significant in flexion during forced varus and internal rotation. In both groups, the same four lesions were produced: 1) Anterior capsule rupture, 2) L-formed rupture of the origin of the pronator muscle with elongation of the anterior bundle of the medial collateral ligament, 3) partial rupture of the lateral collateral ligament and 4) small cartilage damage to the posterior or anteromedial edge of the ulna. In conclusion, hyperextension trauma to the elbow joint induced through the distal ulna or the distal radius produced the same pattern of injury as reported in hyperextension of the elbow with traction to the forearm when free rotation of the radius relative to the ulna was allowed.

Adult↗