Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Quartz”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Study on the therapeutic mechanism of the active principle of the Chinese drug Paeoniae Radix 801 through affinity biosensors IAsys plus quartz crystal microbalance.

OBJECTIVE: To study the targeted point and mechanism of the function of the blood-activating and stasis-removing Chinese drugs, Paeoniae Radix 801(PR801) in its cardiovascular protective effects and its specific binding with endothelin 1 (ET-1) as well as the dynamics of the two's interactive function by means of using affinity biosensors: IAsys Plus and quartz crystal microbalance (IAQCM). METHODS: ET-1 was immobilized on the surfaces of IAQCM by using the new surface modification methods. The PR801 in the solution was detected by modified substrates and the specific binding between PR801 and ET-1 was studied. RESULTS: The curves went up or down after adding PR801. There is specific binding between PR801 and ET-1. The bound mass were 0.458 ng/mm(2) and 133.54 ng/cm(2), respectively. There exists relatively good stability with these two methods. CONCLUSION: The affinity biosensors: IAQCM can be used to study the interaction mechanism between PR801 and ET-1, providing a new way to study the interaction mechanism of TCM. PR801 can bind ET-1 specifically in the experiments. Therefore, ET-1 is another target that PR801 can bind specifically besides thromboxane A(2).

Biosensing Techniques↗

Monitoring apple flavor by use of quartz microbalances.

"Electronic noses", i.e. arrays of differently coated quartz microbalances (QMB), have been used for selective detection of, and discrimination between, volatile organic compounds (VOC) formed during the post-harvest ripening of apples. The flavor components to be differentiated are chemically rather similar carbonyl compounds, chiefly aldehydes and esters. Because their relative ratios change during the post-harvest ripening period, appropriately selected sensor-active layers lead to characteristic patterns of the sensor responses which can be analyzed via pattern-recognition methods. This enables qualitative and quantitative identification of individual components whereby the post-harvest ripening of apples and other fruits can be monitored. Different kinds of apple differ in type and concentration of individual carbonyl compounds.

Aldehydes↗

Reagent injection FIA system for lead determination by hydride generation - quartz-tube atomic absorption spectrometry.

A method is proposed for the determination of lead by generation of its hydride and detection by quartz-tube AAS using a reagent injection FIA system based on the injection of sodium tetrahydroborate. Lead hydride generation was carried out using a combination of 0.5 M nitric acid, 10% m/ v hydrogen peroxide and 10% m/ v sodium tetrahydroborate. The characteristic concentration obtained was 3.1 ng mL(-1) and the detection limit was 2.6 ng mL(-1) for an injected volume of 0.125 mL of tetrahydroborate.

Borohydrides↗

A quartz crystal microbalance sensor for the detection of formic acid vapors.

A new quartz crystal microbalance sensor is developed to determine formic acid at low concentrations. Four previously selected polymers with acid-base characteristics were tested as possible coatings. Polyoxyethylene bis [amine] presented the best results. The sensor is rapid, sensitive [0.67 Hz/(mg/m3)], and reversible at low concentrations. The detection limit for formic acid (7.2 mg/m3) is comparable with the short term exposure limit and the threshold limit values. It presents a fast mechanical response to pressure changes, so that it can be quickly used in different environments and situations. The sensor also shows a good stability in a temperature range typical of work atmospheres (16-36 degrees C). It has a wide linear range (7.2-911.2 mg/m3) and a long useful time. It is also applicable to other low molecular mass carboxylic acids such as acetic acid.

Calibration↗

Isothermal decay studies of intermediate energy levels in quartz.

The recent interest in the thermoluminescence of quartz extracted from unfired building materials, such as mortar and concrete for dose reconstruction applications, led to the requirement of an accurate determination of the lifetime of the intermediate glow peaks in this mineral. The prediction of the lifetimes of these peaks is helpful in establishing the likely time range within which retrospective measurements can be carried out. These peaks, corresponding to intermediate energy levels, occur in the glow curve in the temperature range 150-250 degrees C (heating rate 2 degrees C/s). Lifetimes of 720+/-70 days and 580+/-70 years (at a temperature of 15 degrees C) were derived for the two main peaks placed in the glow curve at approximately 150 degrees C and 200 degrees C, respectively, using the isothermal decay technique. These results as well as the estimated values of the trap parameters (thermal activation energy and frequency factor) have been compared with the data already available in the literature.

Construction Materials↗

Thermoluminescence dating of terrazzo from the monastery church of Tegernsee (Bavaria, Germany) using the 210 degrees C TL peak of quartz.

Thermoluminescence (TL) is one of the most important physical methods used in archaeometry for dating ceramics. In this study the newly developed procedures based on the use of the 210 degrees C TL peak of quartz were applied to well-dated bricks of the church of the Tegernsee monastery in Bavaria. The resulting TL ages obtained from these well-dated bricks were used as a reference for selection of the suitable measurement procedure and to test the precision of the measurements and the accuracy of the technique. The optimized procedure was applied to the terrazzo fragments from the monastery church. The TL results provide a new understanding of the architectural history of the church. The improved measurement procedure including various dose evaluation techniques and the components of the annual dose assessment are described.

Archaeology↗

A low temperature bonding of quartz microfluidic chip for serum lipoproteins analysis.

A low-temperature bonding method for microfabrication of quartz microfluidic chips has been developed. The bonding process involved two steps: pre-bonding and post-annealing at low temperature. The bonding quality was evaluated by measuring the shear force at bonding interface and the electrical properties of the chips. Shear force of 5.66 MPa (566 N/cm(2)) was obtained in a bonded chip after a post-annealing at 200 degrees C for 6 h. We owe the strong bonding strength to the formation of Si-O-Si bonds at the bonding interface during the post-annealing stage. The bonding procedures were not sensitive to surrounding and could be performed in a routine laboratory without clean room conditions. The performance of the fabricated microfluidic chips was tested by capillary zone electrophoresis (CZE) of serum lipoproteins with laser-induced fluorescence (LIF). The low-density (LDL) and high-density (HDL) lipoproteins in the serum was separated completely by using tricine buffer with methylglucamine.

Cold Temperature↗

A thin quartz cell suitable for vacuum ultraviolet absorption and circular dichroism measurements.

The design of a thin quartz cell suitable for absorption and circular dichroism measurements in the vacuum ultraviolet is described. Important features of the cell are (1) that it can be disassembled for cleaning and reproducibly reassembled with path lengths up to 0.3 mm, and (2) that strain in the windows from the compressed sample can be relieved by a sample overflow port. The latter feature allows the cell to be used for circular dichroism as well as absorption measurements.

Circular Dichroism↗

Characterization of monoclonal antibodies to 2,4-dichlorophenoxyacetic acid using a piezoelectric quartz crystal microbalance in solution.

Piezoelectric quartz crystals (resonance frequency 10 MHz) were used for an investigation of the immunochemical reaction between 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide and several monoclonal antibodies prepared against 2,4-D. The herbicide was immobilized on the gold electrodes of the crystals silanized with 3-aminopropyltriethoxysilane. The activated carboxylic group of 2,4-D was linked either directly to the silanized surface or through hexamethylenediamine or albumin as a macromolecule. The interaction of the immobilized antigen with monoclonal antibody in solution was followed as a change in the resonant frequency of the crystals. The best results were achieved using 2,4-D attached to albumin. The affinity binding of five monoclonal antibodies was characterized by association (ka) and dissociation (kd) kinetic rate constants and by equilibrium association constants (KA) which were obtained from the experimental frequency vs. time curves.

2,4-Dichlorophenoxyacetic Acid↗

Quartz crystal microbalance detection of Vibrio cholerae O139 serotype.

A piezoelectric (PZ) quartz crystal microbalance (QCM) biosensor for the rapid detection of Vibrio cholerae serotype O139 has been developed. The antibody to this serotype was immobilized on the gold transducer surface of a 10 MHz AT cut PZ crystal. Solutions containing known antigen concentrations were then incubated for 1 h on the antibody-bound transducer. The biosensor was able to detect 10(5) cells per ml of O139 versus a background of O1 (Ogawa) serotype.

Antigen-Antibody Reactions↗

The chemiluminescence of rabbit alveolar macrophages induced by quartz dust particles.

Quartz dust particles (respirable fraction) triggered luminol-dependent chemiluminescence (CL) when added to unstimulated rabbit alveolar macrophages (AM). It was shown by increasing the dust dose added to the same amount of cells, and conversely, that the intensity of chemiluminescent reaction depended on the ratio cells:dust particles. The ratio giving maximum CL yield was estimated.

Animals↗

Protection against experimental allergic neuritis with silica quartz dust.

Lewis rats sensitized against peripheral nervous system antigens can be protected against experimental allergic neuritis (EAN) by the intraperitoneal injection of silica quartz dust. Two doses of 200 mg silica given 8 and 11 days post-inoculation (dpi) protected against the development of both clinical and pathological disease. A single dose of 200 mg silica 8 dpi gave significant protection against clinical disease but all animals developed pathological signs. A single injection of 200 mg silica 11 dpi, after the onset of early signs, protected against further progression of disease. The protection was long lasting. Given the known toxic effects of silica for macrophages, these results would support the conclusion that macrophages function during the effector stage in the clinical and pathological expression of EAN in the Lewis rat.

Animals↗

Effect of cyclosporin A, silica quartz dust, and protease inhibitors on virus-induced demyelination.

Treatment with cyclosporin A, from the time of virus infection, suppressed inflammation and demyelination in the spinal cord of SJL/J or ASW(H-2s) mice persistently infected with Theiler's murine encephalomyelitis virus. Demyelination was not decreased if treatment was given after inflammation was established. The decrease was independent of serum titers of immunoglobulin G to purified viral antigen but did correlate with decreased proliferation of T lymphocytes to virus and myelin antigens. Silica quartz dust, a direct toxin of macrophages, suppressed demyelination and inflammation if begun at time of virus infection. No therapeutic effect was seen with inhibitors of plasminogen activators or other neutral proteases found primarily in macrophages.

Animals↗

Comparative cytotoxicity of DQ12-quartz and fly ash particles from coal combustion.

Fly ash samples obtained from different coal combustors were tested for cytotoxicity to alveolar macrophages in vitro by measuring the release of dehydrogenase into the culture media. Fly ash samples obtained from the combustion of a variety of coals in several types of combustors were not found to be cytotoxic when compared to a quartz sample of known toxicity.

Air Pollutants↗

Electroimmobilization of proinsulin C-peptide to a quartz crystal microbalance sensor chip for protein affinity purification.

Proinsulin C-peptide was electroimmobilized to a quartz crystal microbalance sensor chip, localizing this low-pI peptide for covalent attachment to activated surface carboxyl groups. The resulting chip was used in a continuous flow biosensor to capture anti-C-peptide antibodies, which could subsequently be eluted in 5% formic acid between air bubbles for efficient recovery and mass spectrometric identification. The method is reproducible through repeated cycles, providing affinity purification of proteins under real-time monitoring of the binding and elution processes.

Amino Acid Sequence↗

Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix.

A quartz crystal microbalance (QCM) cell biosensor utilizing living endothelial cells (ECs) or human breast cancer cells (MCF-7) adhering to the gold QCM surface was used to study the relative contributions of the cells and their underlying extracellular matrix (ECM) to the measured QCM Deltaf and DeltaR shifts. The ECM represents a natural biomaterial that is synthesized by the cells to enable their attachment to surfaces. We followed the detachment of the ECs or MCF-7 cells from their ECM using a nonproteolytic method and were able to apportion the total frequency, Deltaf, decrease of the biosensor into contributions from cell attachment and from the intact underlying ECM. We also demonstrated that the Deltaf shift remaining after EC removal corresponds to ECM as determined by light microscopic visualization of the stained protein. During the process of cell detachment, we observed a novel transient increase in viscoelastic behavior expressed as a transient increase in the motional resistance, DeltaR, parameter. Then we showed via a simulation experiment using ECs stained with fluorescent rhodamine-labeled phalloidin, an actin stain, that the transient viscoelastic increase correlated with cellular stress exhibited by the cells during removal with ethylene glycol bis(2-aminoethyl ether)-N,N,N',N'- tetraacetic acid. Prior to cells lifting from their ECM, the attached ECs rearrange their actin microfilaments first into peripheral stress fibers and second into internal aggregates, to maintain cell-cell connectivity, retain their spread morphology, and attempt to adhere more tightly to their underlying ECM. The decrease in DeltaR following its transient rise corresponds to cells finally losing their attachment focal points and lifting from the ECM. We also characterized the normalized f shifts, -Delta(Deltaf)(ECM)/attached cell and -Delta(Deltaf)(cells)/attached cell, as a function of varying the number of adherent cells. Finally, we demonstrate that the underlying native ECM biomaterial, from which all cells have been removed, does not exhibit any significant level of energy dissipation, in contrast to the cells when they are attached to the ECM.

Biosensing Techniques↗

Development of quartz-crystal-microbalance-based immunosensor array for clinical immunophenotyping of acute leukemias.

An integrated piezoelectric immunosensor array has been developed to immunophenotype acute leukemias in clinic. Each quartz crystal microbalance (QCM) was fabricated with plasma-polymerized film of n-butylamine, nanogold particles, and protein A (PA) to be used to immobilize antibodies in orientation. Leukemic lineage-associated monoclonal antibodies were separately immobilized onto the nanogold-PA-modified surface of the crystals, which were constructed by a 2 x 2 type of probes forming a QCM-based immunosensor array. The main detection conditions were investigated, including the immobilization amount of antibodies, pH, immunoreaction time, sample dilution ratio, etc. The immunophenotyping feasibility of the new technique was investigated through simultaneously analyzing Jurkat cells by the immunosensor array method, immunohistochemistry, and flow cytometry. It was found that the developed technique could readily identify leukemia samples in 5 min and might monitor dynamically the immunoreaction processes. Moreover, comparison studies were carried out for CD antigens expressed on the nucleated cells isolated from 96 acute leukemic patients and 24 normal subjects using the QCM-based immunosensor method and the fluoroimmunoassay. Results obtained by immunophenotyping patients' samples with the immunosensor-based method achieved the rate of 88.93% in 768 groups of numerical data, where no significant statistical difference was observed between the two methods when checked by chi2 analysis (chi2 = 3.4, p > 0.05). This new immunosensor array showed the merits of high sensitivity, high specificity, good reproducibility, easy operation, and low cost. The results of specimen evaluation indicated that it might be clinically suitable for quantifying human differentiated leukocytes and immunophenotyping of acute leukemias.

Acute Disease↗

A comparative study of the cytoskeleton binding drugs nocodazole and taxol with a mammalian cell quartz crystal microbalance biosensor: different dynamic responses and energy dissipation effects.

The quartz crystal microbalance (QCM) was used to create piezoelectric whole-cell biosensors utilizing either living endothelial cells (ECs) or the metastatic human mammary cancer cell line MDA-MB-231 adhering to the gold QCM surface under in vitro growth conditions. We utilized the whole-cell QCM biosensors for the detection of the effects of varying concentrations of the microtubule binding drugs taxol and nocodazole by measuring changes in the QCM steady state frequency (Deltaf) and motional resistance (DeltaR), shift values. Using 0.11-50 microM nocodazole, we observed the Deltaf shift values of the biosensors, consisting of 20,000 ECs, to decrease significantly in magnitude (nearly 100%) to a limiting value, in a dose-dependent fashion, over a 5- to 6-h incubation period following drug addition. This effect is consistent with nocodazole's known disruption of intracellular microtubules. On the other hand, 10 microM taxol caused little alteration in Deltaf over the same time period, consistent with its microtubule hyperstabilization effect. When the EC QCM biosensor Deltaf shift values were normalized by the number of ECs found firmly attached to the QCM surface via trypsin removal and electronic counting, the dose curve was shifted to lower nocodazole concentrations, resulting in a more sensitive drug biosensor. The kinetics of the Deltaf decrease with increasing nocodazole concentrations measured by the EC QCM biosensor was found to be similar at all drug concentrations and was well fit by a single first-order exponential decay equation. For all nocodazole doses, t(0.5) was invariant, averaging t(0.5)=0.83+/-0.14 h. These data demonstrate that a single dynamic sensing system within the cell, the microtubules, is disrupted by the addition of nocodazole and this process is sensed by the cell QCM biosensor. This interpretation of the data was confirmed by a fluorescence light microscopy investigation of ECs undergoing treatment with increasing nocodazole doses using a fluorescent antibody to alpha-tubulin. These studies revealed a corresponding loss of the spread morphology of the cells, concomitant with a rearrangement of the extended native microtubules into increasingly large aggregates with the cells eventually lifting from the surface in significant numbers at 50 microM. At 6 microM nocodazole, partial reversibility of the EC QCM biosensor was demonstrated. These results indicate that the EC QCM biosensor can be used to detect and study EC cytoskeleton alterations and dynamics. We suggest the potential of this cellular biosensor for the real-time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment and cellular spreading, regardless of their molecular mechanism of action.

Animals↗