Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulse sequences”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

The transient processes in multi-pulse nitrogen-14 NQR.

It has been demonstrated that transient processes, observed in a single crystal of NaNO2 acted upon by pulse sequences MW-2 and MW-4 and their modifications with 180 degrees flip angle of the pulses (Solid State Nucl. Magn. Resonance 10 (1997) 63; Sov. Phys.-JETP 88(5) (1999) 1580), which manifest themselves in the oscillating form of the NQR signals envelope, can be explained in the frames of a two-particle model. It has been proved that the nature of echo signals in the effective field of multi-pulse sequences received by the inversion of the phase of the sequence pulses or by introducing an additional 180 degrees pulse is connected with re-focusing of accumulated digressions of the flip angle from the ideal 180 degrees pulse. Experimental results of observing single and multiple echoes in a number of powdered nitrogenated substances in the effective field of various sequences at room temperature have been presented.

Journal Article↗

Contrast optimization for the detection of focal hepatic lesions by MR imaging at 1.5 T.

The relative efficacies of different spin-echo pulse sequences at 1.5 T were evaluated in the detection of focal hepatic disease. Pulse sequences compared were spin-echo with a repetition time (TR) of 200 msec and echo time (TE) of 20 msec, with six excitations; TR = 300 msec, TE = 20 msec, with 16 excitations (T1-weighted sequences); and a double spin-echo with TR = 2500 and TE = 25 and 70, with two excitations (proton-density-weighted and T2-weighted pulse sequences, respectively). Respiratory-motion compensation, which involved a recording of the phase-encoding gradients (Exorcist), was used for the last two sequences. Spin-echo with TR = 2500 msec and TE = 70 msec was superior in lesion detection and contrast-to-noise ratio. The proton-density-weighted and T2-weighted sequences with respiratory compensation produced better artifact suppression than did the short TR, short TE T1-weighted sequence with temporal averaging. In contradistinction to prior results at 0.6 T, T2-weighted pulse sequences appear superior to T1-weighted pulse sequences with multiple excitations for both lesion detection and artifact suppression at 1.5 T.

Cysts↗

Assignment of aliphatic side-chain 1HN/15N resonances in perdeuterated proteins.

The perdeuteration of aliphatic sites in large proteins has been shown to greatly facilitate the process of sequential backbone and side-chain 13C assignments and has also been utilized in obtaining long-range NOE distance restraints for structure calculations. To obtain the maximum information from a 4D 15N/15N-separated NOESY, as many main-chain and side-chain 1HN/15N resonances as possible must be assigned. Traditionally, only backbone amide 1HN/15N resonances are assigned by correlation experiments, whereas slowly exchanging side-chain amide, amino, and guanidino protons are assigned by NOEs to side-chain aliphatic protons. In a perdeuterated protein, however, there is a minimal number of such protons. We have therefore developed several gradient-enhanced and sensitivity-enhanced pulse sequences, containing water-flipback pulses, to provide through-bond correlations of the aliphatic side-chain 1HN/15N resonances to side-chain 13C resonances with high sensitivity: NH2-filtered 2D 1H-15N HSQC(H2N-HSQC), 3D H2N(CO)C gamma/beta and 3D H2N(COC gamma/beta)C beta/alpha for glutamine and asparagine side-chain amide groups; 2D refocused H(N epsilon/zeta)C delta/epsilon and H(N epsilon/zeta C delta/epsilon)C gamma/delta for arginine side-chain amino groups and non-refocused versions for lysine side-chain amino groups; and 2D refocused H(N epsilon)C zeta and nonrefocused H(N epsilon, eta)C zeta for arginine side-chain guanidino groups. These pulse sequences have been applied to perdeuterated 13C-/15N-labeled human carbonic anhydrase II (2H-HCA II). Because more than 95% of all side-chain 13C resonances in 2H-HCA II have already been assigned with the C(CC)(CO)NH experiment, the assignment of the side-chain 1HN/15N resonances has been straightforward using the pulse sequences mentioned above. The importance of assigning these side-chain HN protons has been demonstrated by recent studies in which the calculation of protein global folds was simulated using only 1HN-1HN NOE restraints. In these studies, the inclusion of NOE restraints to side-chain HN protons significantly improved the quality of the global fold that could be determined for a perdeuterated protein [R.A. Venters et al. (1995) J. Am. Chem. Soc., 117, 9592-9593].

Amino Acid Sequence↗

High intensity focused ultrasound ablation of kidney guided by MRI.

The effectiveness of magnetic resonance imaging (MRI) to monitor therapeutic protocols of high-intensity focused ultrasound (HIFU), in freshly excised pig kidney cortex is investigated. For high quality imaging, the pulse sequence fast spin echo (FSE) T1- and T2-weighted, and proton density were evaluated. For fast imaging, the pulse sequence T1-weighted fast spoiled gradient (FSPGR) was used. The main goal was to evaluate the MRI detection of large lesions (bigger than 1 cm x 1 cm x 1 cm) that is achieved by moving the transducer in a predetermined pattern. The contrast between lesion and kidney tissue is excellent with either T1-weighted or T2-weighted FSE. With T1-weighted FSE, the best contrast is observed for recovery time (TR) between 200 ms and 400 ms. With T2-weighted FSE best contrast can be achieved for echo time (TE) between 16 and 32 ms. T2-weighted FSE was proven as the best pulse sequence to detect cavitational activity. This advantage is attributed to the significant difference in signal intensity between air spaces and necrotic tissue. Air spaces appear brighter than thermal lesions. Therefore, for therapeutic protocols created using cavitational mode, T2-weighted FSE may be the optimum pulse sequence to use. The proton density pulse sequence does not provide any advantage over the T1- and T2-weighted pulse sequences. Using T1-weighted FSPGR, acquisition time as low as 5 s could be achieved. Good contrast and signal-to-noise ratio (SNR) are achieved with TR = 100 ms and flip angle between 75 to 90 degrees. The above techniques were very successful in detecting large lesion volumes.

Animals↗

MR sequence parameter optimization: an algorithmic approach.

The MR pulsing sequence is often described by terms such as spatial resolution, signal-to-noise, coverage, acquisition time, and contrast. These might be considered "secondary" parameters because they are not set directly but are instead specified indirectly by setting the "primary" parameters: field of view; projections (phase-encoded or readout); slice thickness and gap; number of excitations; and the sequence parameter times--repetition, echo delay, and inversion. Together, the primary and secondary parameters specify the MR pulsing sequence. Many of these parameters are interrelated such that setting one parameter indirectly affects another. Parameter specification is thus an iterative procedure that involves compromises to achieve an optimum relative to some predefined criteria. In this article, we examine the interrelationships between the primary and secondary parameters that specify the spin-echo pulsing sequence and suggest an algorithmic approach for selecting the best sequence parameters.

Algorithms↗

Combined diffusion weighting and CSF suppression in functional MRI.

In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal-to-noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 +/- 73 pixels (mean +/- SD) using the standard EPI pulse sequence, 31 +/- 12 pixels using IR-EPI and 15 +/- 13 pixels when DW-IR-EPI was employed. The relative signal increase was 5.7 +/- 1.1% using standard EPI, 11.5 +/- 3.1% using IR-EPI and 9.9 +/- 2.4% using DW-IR-EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 +/- 50 pixels using the standard EPI, and when using IR-EPI, the activated volume was 28 +/- 13 pixels. At equal S/N, the signal increase was 7.3 +/- 1.4% using standard EPI and 12.0 +/- 3.6% using IR-EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels.

Adult↗

Detection of hepatic malignancies using Mn-DPDP (manganese dipyridoxal diphosphate) hepatobiliary MRI contrast agent.

A new hepatobiliary contrast agent (Mn-DPDP) was used in the detection of liver metastases in six rabbits with seven hepatic V2 carcinomas. This contrast agent is derived from pyridoxyl-5-phosphate which is biomimetically designed to be secreted by the hepatocyte. After Mn-DPDP administration, a 105% increase in liver signal to noise was obtained using a 200/20 (TR/TE) pulsing sequence, and a 62% decrease in intensity was observed using a 1200/60 pulsing sequence. Liver V2 carcinoma contrast enhancement increased 427% using the 200/20 pulsing sequence and 176% using the 1200/60 pulsing sequence. Four of seven V2 carcinomas were not detectable prior to the administration of Mn-DPDP (50 mumol/kg). Two neoplasms were only detectable in retrospect (after Mn-DPDP) on the 1200/60 sequence. The smallest neoplasms detected in this study were 1-4 mm. Mn-DPDP appears to be a promising MRI contrast agent.

Animals↗

MR diagnosis of meniscal tears of the knee: value of axial three-dimensional Fourier transformation GRASS images.

Axial MR images of 40 knees in 37 patients with clinically suspected meniscal tears were obtained by using a three-dimensional (3-D) Fourier transform, gradient-refocused acquisition in the steady state (GRASS) pulse sequence. All knees also were examined in both coronal and sagittal planes with a two-dimensional (2-D) Fourier transform, spin-echo pulse sequence for T1-weighted images and a multiplanar GRASS pulse sequence for T2*-weighted images (conventional 2-D pulse sequences). Arthroscopic confirmation was available in all cases and was used as the gold standard. In these 40 knees, 32 of 33 meniscal tears and 45 of 47 normal menisci were correctly identified with axial 3-D imaging, yielding a sensitivity of 97% and specificity of 96%. Conversely, the sensitivity was 82% and the specificity was 100% for the 2-D technique in the diagnosis of meniscal tears. A combination of both techniques yielded 100% sensitivity, 100% specificity, and 100% accuracy in the evaluation of the menisci. Seven discrepancies between the findings of the two techniques were found in the evaluation of 33 arthroscopically proved torn menisci; six of the seven represented false-negative 2-D images and one was a false-negative axial 3-D image. Of 47 normal menisci, only two false-positives occurred with axial 3-D imaging and none with 2-D imaging. Despite the lack of a statistically significant difference, these preliminary findings suggest that the sensitivity in the diagnosis of meniscal tears can be improved by adding thin-sliced axial images with the 3-D GRASS pulse sequence to conventional 2-D imaging.

Adolescent↗

MR fat suppression technique in the evaluation of normal structures of the knee.

The chopper fat suppression (CFS) pulse sequence, which is a phase sensitive implementation of the Dixon fat suppression method and the spin echo (SE) pulse sequence, was used in the evaluation of anatomic structures of the normal knee using 48 sets of imaging sequences in six volunteers using a repetition time/echo time combination of 1,500/30, 60 ms. A demonstration of the CFS technique in 10 patients with suspected knee pathology is also presented. A semiquantitative grading scale was established to rate anatomic visualization and used to compare CFS and SE pulse sequence techniques. The results in normal subjects demonstrate that hyaline cartilage is significantly better visualized by fat suppression pulse sequence than by conventional SE pulse sequence in the coronal and sagittal planes of imaging (p less than 0.001). The preliminary results from patients studies suggest that CFS imaging may be useful in the evaluation of meniscal tears, in the differentiation of hyaline cartilage from joint fluid, and in the detection of both soft tissue and bone injuries.

Adipose Tissue↗

Improved spin-echo-edited NMR diffusion measurements.

The need for simple and robust schemes for the analysis of ligand-protein binding has resulted in the development of diffusion-based NMR techniques that can be used to assay binding in protein solutions containing a mixture of several ligands. As a means of gaining spectral selectivity in NMR diffusion measurements, a simple experiment, the gradient modified spin-echo (GOSE), has been developed to reject the resonances of coupled spins and detect only the singlets in the (1)H NMR spectrum. This is accomplished by first using a spin echo to null the resonances of the coupled spins. Following the spin echo, the singlet magnetization is flipped out of the transverse plane and a dephasing gradient is applied to reduce the spectral artifacts resulting from incomplete cancellation of the J-coupled resonances. The resulting modular sequence is combined here with the BPPSTE pulse sequence; however, it could be easily incorporated into any pulse sequence where additional spectral selectivity is desired. Results obtained with the GOSE-BPPSTE pulse sequence are compared with those obtained with the BPPSTE and CPMG-BPPSTE experiments for a mixture containing the ligands resorcinol and tryptophan in a solution of human serum albumin.

Albumins↗

MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils.

PURPOSE: To implement and optimize a real-time pulse sequence and user interface to perform intravascular interventions using active catheter tracking. MATERIALS AND METHODS: In magnetic resonance (MR)-guided interventions, small radio-frequency coils can be used to rapidly determine the device position (active tracking). In this work, active catheter tracking was combined with a dedicated real-time pulse sequence and user interface. The pulse sequence offered the imaging contrasts fast low angle shot (FLASH), true Fast imaging with steady state precession (TrueFISP), and projection MR digital subtraction angiography (MR-DSA), which could be selected by the radiologist from within the scanner room at any time during the intervention. Automatic slice positioning was added to the real-time pulse sequence so that the location of the tracking coils defined the image slice position and orientation. The technique was assessed in phantoms and animal experiments. RESULTS: At a reaction time of 24 msec and a frame rate of three images per second, the movement of an active intravascular catheter could be monitored in the aorta and the renal arteries of a pig. With interactive contrast and orientation changes, the renal vasculature could be assessed by a fully MR-guided catheterization in less than 10 minutes. CONCLUSION: With carefully designed active catheters, a dedicated user interface, and an optimized pulse sequence intravascular interventions can successfully be performed by a single operator from within the MR scanner room.

Animals↗

Metallic artifacts in magnetic resonance imaging of patients with spinal fusion. A comparison of implant materials and imaging sequences.

STUDY DESIGN: Devices for spinal fusion were compared with respect to their influence on magnetic resonance images. In addition, different magnetic resonance pulse sequences were evaluated to elicit their susceptibility to imaging artifacts. OBJECTIVES: To determine the implants with the least imaging artifacts as a recommendation for the spine surgeon and to assess the best imaging strategy for the radiologist. SUMMARY OF BACKGROUND DATA: For patients who have had surgical spinal fusion with instrumentation, magnetic resonance imaging is the most favorable diagnostic method. Unfortunately, metallic implants lead to severe degradation of image quality. These artifacts depend on the material of the implant and on the choice of the pulse sequence. METHODS: The fusion devices were mounted on a simple plastic phantom in various combinations and were imaged on 1.5-T magnetic resonance units. Frequently used types of plates and screws made of titanium or steel in various alloys were examined on the phantom with routinely used pulse sequences. The results of these examinations were compared with those in patient studies involving the same implants as well as the same pulse sequences. RESULTS: The least imaging artifacts were caused by titanium implants, especially when using shorter screws, wider screw placement, and thinner titanium plates. Nevertheless, there were distinct image distortions that could lead to erroneous image interpretation. The best images were acquired by spin echo (T1), turbo spin echo (T1, T2), and half Fourier single shot turbo spin echo (HASTE) sequences. Sequences containing any gradient echo components (gradient echo or turbo gradient and spin echo sequence or frequency-selective fat saturation techniques) resulted in the highest amount of image degradation. CONCLUSION: By choosing appropriate spinal fusion devices as well as pulse sequences, postoperative magnetic resonance imaging examinations can give acceptable results, in spite of the presence of metallic implants.

Adolescent↗

Differences in definity and optison microbubble destruction rates at a similar mechanical index with different real-time perfusion systems.

The purpose of this study was to determine microbubble responses to different pulse sequence schemes that exist on low mechanical index (MI) real-time perfusion imaging systems using either intravenous albumin-coated (Optison) or lipid-encapsulated (Definity) microbubbles. A tissue-mimicking phantom was created that permitted insonation of microbubbles at 3 cm (near field) and 9 cm (far field) from the diagnostic transducer face. Differences in effluent microbubble concentration were measured after they passed through vessels being insonified with pulse sequence schemes that transmitted alternating polarity (pulse inversion Doppler), alternating amplitude (power modulation), or both (contrast pulse sequencing) at a similar MI, frame rate, and transmit frequency. Normalized contrast signal intensity within a recirculating chamber was also measured in the near and far field. Pulse inversion Doppler produced less initial normalized contrast signal intensity and greater destruction rates than amplitude varying pulse sequence schemes like power modulation or contrast pulse sequencing at both the 0.1- and 0.2-MI settings. These differences indicate that the same MI setting on different real-time perfusion imaging techniques will produce different microbubble responses.

Albumins↗

Gradient preemphasis calibration in diffusion-weighted echo-planar imaging.

This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions. The efficiency of the technique was demonstrated not only by the reduction of eddy-current fields to a negligible level using full preemphasis compensation, but also by the fact that adjustment of the slow time-base alone sufficed for the practical elimination of image distortions in the DW-SE-EPI images and the subsequent diffusion tensor maps (in a phantom and a human brain). By seeking to eliminate directly the effect of eddy-current-induced phase shifts during the EPI data collection, the method is free of the complications and restrictions associated with other eddy-current correction techniques for DW-SE-EPI (such as acquisition of additional calibration scans, intense postprocessing, extensive pulse-sequence modifications), making their use redundant.

Brain↗

Phase-Sensitive Two-Dimensional Heteronuclear Zero- and Double-Quantum-Coherence Spectroscopy

New pulse sequences for two-dimensional phase-sensitive detection of heteronuclear zero- and double-quantum coherence are presented for use with and without pulsed field gradients. The magnetization is phase modulated during t1 and then transferred to a proton for detection using a novel approach similar to the sensitivity-enhancement technique [Palmer et al. J. Magn. Reson. 93, 151 (1991)]. These pulse sequences are useful for the measurement of size and relative sign of passive J couplings as well as for the measurement of the relaxation rates of zero- and double-quantum coherence. They can also be used as building blocks in multidimensional pulse sequences. The pulse sequences are tested on the peptide hormone motilin with a selectively 13C-enriched alpha carbon.

Journal Article↗

The use of finite impulse response filters in pulse design.

We develop a new way of synthesizing pulse sequences with desirable frequency characteristics. By combining our previous results with techniques from the theory of finite impulse response filters, we can specify (1) the total duration of the pulse sequence, (2) the frequency ranges it is desired to perturb, (3) the desired perturbation, and (4) the frequency range it is desired not to perturb. We can then synthesize a hard pulse sequence which will yield that desired perturbation with the minimal possible error. The minimum error is global, in the sense that no pulse sequence can do better at achieving the specifications, and is not just a local minimum, around the pulse sequences close to the derived pulse.

Algorithms↗

Manual sequencing using pulsed field.

The use of pulsed fields in manual sequencing opens up the compression zone found with a DC field and extends the range of resolution from a few hundred bases to several thousand bases. The band inversion problem is overcome with the proper pulsing conditions, and the bands are sharper than for the DC field case. Accurate visual reading is possible up to about 800-900 bases. The method is compatible with automation techniques, since the band spectrum is stretched continuously during migration, and the smaller fragments are run off the gel.

Base Sequence↗

Reproducibility of left ventricular mass measurement using a half-Fourier black-blood single-shot fast spin-echo sequence within a single breath hold: comparison with a conventional multiple breath-hold segmented gradient echo technique in patients.

PURPOSE: To compare the reproducibility of left ventricular (LV) mass measurements using a black-blood half-Fourier single-shot fast spin-echo (SSFSE) and a segmented gradient echo magnetic resonance (MR) pulse sequence. MATERIAL AND METHODS: Breath-hold SSFSE and segmented gradient echo cardiac MR examinations were performed twice in 32 patients and manual detection of the LV endocardium and epicardium was applied by two blinded reviewers. The SSFSE pulse sequence allowed whole-heart coverage in a single breath hold, while multiple breath holds were required using the segmented gradient echo sequence. Spatial presaturation slabs were used with the SSFSE pulse sequence to reduce the field of view (FOV) and thereby achieve higher spatial resolution. RESULTS: Intraclass correlation coefficients were higher with the SSFSE pulse sequence than with the segmented gradient echo pulse sequence: intraobserver reproducibility reached 0.999 vs. 0.991; interobserver reproducibility: 0.997 vs. 0.981; and interstudy reproducibility: 0.998 vs. 0.936. These higher levels of reproducibility were confirmed on Bland and Altman plots. CONCLUSION: LV mass measurements can be assessed more reproducibly with the single breath-hold SSFSE technique than with the standard multiple breath-hold segmented gradient echo method.

Adult↗