Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Preparative isolation and purification of amides from the fruits of Piper longum L. by upright counter-current chromatography and reversed-phase liquid chromatography.

A versatile counter-current chromatography (CCC) with upright type-J multilayer coil planet centrifuge, named upright CCC, was applied to the isolation and purification of amides from Piper longum L., which is widely used as an anodyne and a treatment for stomach disease in China. After the saponification by KOH of the ethanol extracts solution of 15 kg of crude drug "Piper Longi Fructus", the fruits of P. longum L., the solution was extracted with light petroleum and 500 g of red crude oil was obtained. Using 2.5 g of red crude oil as sample, the preparative upright CCC with a two-phase system composed of light petroleum (bp 60-90 degrees C)-ethyl acetate-tetrachloromethane-methanol-water (1:1:8:6:1, v/v) was successfully performed, which yielded nine fractions. Then these fractions were further purified by use of reversed-phase liquid chromatography (RPLC) with a glass column of 500 x 10 mm i.d. packed with reversed-phase silica gel. As a result, nine target amides with over 95% purity, i.e., 50 mg of (2E,4E)-N-isobutyl-eicosa-2,4-dienamide, 150 mg of (2E,4E,14Z)-N-isobutyl-eicosa-2,4,14-trienamide, 110 mg of (2E,4E,12Z)-N-isobutyl-ocatadeca-2,4,12-trienamide, 50 mg of guineensine, 60 mg of pipernonaline, 75 mg of pellitorine, 63 mg of piperine, 45 mg of piperanine, and 40 mg of piperlonguminine were isolated, respectively. Structures of all compounds were identified by electrospray ionization MS, electron impact ionization MS, one- and two-dimensional NMR spectra.

Amides↗

Comparison of conventional gas chromatography and comprehensive two-dimensional gas chromatography for the detailed analysis of petrochemical samples.

Comprehensive two-dimensional gas chromatography (GC x GC) has been investigated for the characterization of high valuable petrochemical samples from dehydrogenation of n-paraffins, Fischer-Tropsch and oligomerization processes. GC x GC separations, performed using a dual-jets CO2 modulator, were optimized using a test mixture representative of the hydrocarbons found in petrochemicals. For complex samples, a comparison of GC x GC qualitative and quantitative results with conventional gas chromatography (1D-GC) has demonstrated an improved resolution power of major importance for the processes: the group type separation has permitted the detection of aromatic compounds in the products from dehydrogenation of n-paraffins and from oligomerization, and the separation of alcohols from other hydrocarbons in Fischer-Tropsch products.

Chromatography, Gas↗

Characterization of complex hydrocarbons in cigarette smoke condensate by gas chromatography-mass spectrometry and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

Gas chromatography-mass spectrometry with electron ionization and positive-ion chemical ionization and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF-MS) were applied for the characterization of the chemical composition of complex hydrocarbons in the non-polar neutral fraction of cigarette smoke condensates. Automated data processing by TOF-MS software combined with structured chromatograms and manual review of library hits were used to assign the components from GC x GC-TOF-MS analysis. The distributions of aliphatic hydrocarbons and aromatics were also investigated. Over 100 isoprenoid hydrocarbons were detected, including carotene degradation products, phytadiene isomers and carbocyclic diterpenoids. A total of 1800 hydrocarbons were tentatively identified, including aliphatic hydrocarbons, aromatics, and isoprenoid hydrocarbons. The identified hydrocarbons by GC x GC-TOF-MS were far more than those by GC-MS.

Gas Chromatography-Mass Spectrometry↗

Group-type characterisation of mineral oil samples by two-dimensional comprehensive normal-phase liquid chromatography-gas chromatography with time-of-flight mass spectrometric detection.

Normal-phase liquid chromatography (NPLC) and capillary gas chromatography (GC) are complementary techniques, which makes them ideally suited for hyphenated and comprehensive coupling. In this work, an LC and a GC equipped with a time-of-flight mass spectrometer were on-line and comprehensively coupled (LC x GC-ToF MS) for the analysis of mineral oil samples. Classes of compounds present in the oil like paraffins, mono-aromatic and multi-aromatic compounds were separated by normal-phase LC. with a subsequent boiling-point separation within each class by means of GC. Sub-groups present in each class of compounds were distinguished by selecting their unique masses.

Gas Chromatography-Mass Spectrometry↗

Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.

1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The relative standard deviation (R.S.D.) values of each analytical method were smaller than 3%. The amount of 1,4-dioxane was found to vary from 11.6 +/- 0.3 ppm to 73.5 +/- 0.5 ppm in 30% of nonionic surfactants from manufacturers in Taiwan. These methods were linear over the studied range of 3-150 ppm with correlation coefficients higher than 0.995. The recoveries of 1,4-dioxane for these nonionic surfactants following SPME were all higher than 96 +/- 1% (n = 3). The detection limits of 1,4-dioxane for these nonionic surfactants following SPME were from 0.06 ppm to 0.51 ppm. The experimentally determined level of 1,4-dioxane in cosmetics from manufacturers in Taiwan varied from 4.2 +/- 0.1 ppm to 41.1 +/- 0.6 ppm in 22% of daily used cosmetics following SPME coupled with GC and GC-MS. Conventional solvent extraction takes around 1 h for extraction and reconcentration but SPME takes only around 10 min. SPME provides better analyses of 1,4-dioxane in nonionic surfactants and cosmetics than conventional solvent extraction and head space pretreatments in term of simplicity, speed, precision, detection limit, and solvent consumption.

Calibration↗

Trace anion determination in concentrated hydrofluoric acid solutions by two-dimensional ion chromatography I. Matrix elimination by ion-exclusion chromatography.

Since years, ion exclusion chromatography (ICE) has been the standard method to separate strong acid analyte anions from concentrated weak acid matrices such as hydrofluoric acid (HF). In this work, the commercially available IonPac ICE-AS 1 column was used to separate trace levels of chloride, nitrate, sulfate and phosphate from HF solutions at 20% (w/w). The efficiency of the separation was studied in more detail using techniques such as ion chromatography (IC), inductively coupled plasma optical emission spectrometry (ICP-OES) and ICP-mass spectrometry (ICP-MS). For 20% (w/w) HF solutions and at a water carrier flow-rate of 0.50 ml/min, the cut window was set from 8.5 to 14.5 min. Under these conditions, analyte recoveries of better than 90% were obtained for chloride, nitrate and sulfate, but only about 75% for phosphate. The HF rejection efficiency was better than 99.9%. It was found that the ICP techniques, measuring total element levels and not species, yielded significantly higher recoveries for phosphorus and sulfur compared to IC. Evidence will be given that part of the added phosphorus (approximately 15% for an addition of 10 mg PO4/kg) is present as mono-fluorophosphoric acid (H2FPO3). In the case of sulfate, the difference between IC and ICP-MS could be attributed to an important matrix effect from the residual HF concentration.

Algorithms↗

Integration of ion-exchange chromatography fractionation with reversed-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometer and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for isolation and identification of compounds in Psoralea corylifolia.

An approach for the separation and identification of components in a traditional Chinese medicine Psoralea corylifolia was developed. Ion-exchange chromatography (IEC) was applied for the fractionation of P. corylifolia extract, and then followed by concentration of all the fractions with rotary vacuum evaporator. Each of the enriched fractions was then further separated on an ODS column with detection of UV absorbance and atmospheric pressure chemical ionization mass spectrometer (APCI/MS), respectively, and also analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) with matrix of oxidized carbon nanotubes. Totally more than 188 components in P. corylifolia extract were detected with this integrated approach, and 12 of them were preliminary identified according to their UV spectra and mass spectra performed by APCI/MS and MALDI-TOF/MS. The obtained analytical results not only demonstrated the powerful resolution of integration IEC fractionation with reversed-phase liquid chromatography (RPLC)-APCI/MS and MALDI-TOF/MS for analysis of compounds in a complex sample, but also exhibited the superiority of APCI/MS and MALDI-TOF/MS for identification of low-mass compounds, such as for study of traditional Chinese medicines (TCMs) and metabolome.

Atmospheric Pressure↗

Simultaneous determination of synthetic phosphodiesterase-5 inhibitors found in a dietary supplement and pre-mixed bulk powders for dietary supplements using high-performance liquid chromatography with diode array detection and liquid chromatography-electrospray ionization tandem mass spectrometry.

A high-performance liquid chromatography-diode array detection (HPLC-DAD) method and a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method were developed to screen for the presence of synthetic phosphodiesterase-5 (PDE-5) inhibitors and their analogues, namely sildenafil, vardenafil, tadalafil, homosildenafil, acetildenafil and hydroxyhomosildenafil. The methods were applied to pre-market samples submitted to the Health Sciences Authority of Singapore (HSA) for testing. One sample was in the form of capsules while six other samples were pre-mixed bulk powder samples for dietary supplements to be repackaged or formulated into the final dosage forms (usually capsules). Identification of PDE-5 inhibitors and their analogues was achieved by comparing individual peak retention times, UV spectra and mass spectra with those of reference standards. The seven samples were found to contain at least one of the following compounds: sildenafil, vardenafil, hydroxyhomosildenafil, homosildenafil and acetildenafil. The five compounds were simultaneously determined by LC-ESI-MS/MS in multiple reactions monitoring (MRM) scan mode. The method has been validated for accuracy, precision, linearity and sensitivity.

3',5'-Cyclic-GMP Phosphodiesterases↗

Purification of coenzyme Q10 from fermentation extract: high-speed counter-current chromatography versus silica gel column chromatography.

High-speed counter-current chromatography (HSCCC) is applied to the purification of coenzyme Q(10) (CoQ(10)) for the first time. CoQ(10) was obtained from a fermentation broth extract. A non-aqueous two-phase solvent system composed of heptane-acetonitrile-dichloromethane (12:7:3.5, v/v/v) was selected by analytical HSCCC and used for purification of CoQ(10) from 500 mg of the crude extract. The separation yielded 130 mg of CoQ(10) at an HPLC purity of over 99%. The overall results of the present studies show the advantages of HSCCC over an alternative of silica gel chromatography followed by recrystallization. These advantages extend to higher purity (97.8% versus 93.3%), recovery (88% versus 74.3%) and yield (26.4% versus 23.4%). An effort to avoid the toxic, expensive solvent CH(2)Cl(2) was unsuccessful, but at least its percentage is low in the solvent system.

Agrobacterium tumefaciens↗

Investigation of the use of immobilised metal affinity chromatography for the on-line sample clean up and pre-concentration of nucleotides prior to their determination by ion pair liquid chromatography-electrospray mass spectrometry: a pilot study.

This study explored an alternative way to enrich and pre-purify biological samples containing nucleoside mono-, di- and triphosphates. These compounds were trapped by immobilised metal affinity chromatography (IMAC) on a Poros 20 MC IMAC-column, which was conditioned with Fe3+. The IMAC-column was implemented in a column switching set-up separating nucleoside mono-, di- and triphosphates on a Hypersil ODS 35 mm x 0.3 mm capillary column hyphenated to electrospray mass spectrometry resulting in the first miniaturised column switching liquid chromatography-mass spectrometry (LC-MS) system for nucleotides.

Chromatography, Affinity↗

Identification of kinetin and kinetin riboside in coconut (Cocos nucifera L.) water using a combined approach of liquid chromatography-tandem mass spectrometry, high performance liquid chromatography and capillary electrophoresis.

Kinetin (free base and riboside), which was assumed by many scientists to be a synthetic cytokinin plant growth hormone, has been detected for the first time in the endosperm liquid of fresh young coconut fruits ("coconut water"). To facilitate the study, we developed a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the identification and quantification of kinetin and kinetin riboside in purified coconut water extract sample. Following a solid-phase extraction of cytokinins in coconut water using C18 columns, the samples were further purified by Oasis MCX columns and analyzed by LC-MS/MS for kinetin and kinetin riboside. Detection by mass spectrometry was carried out using selected reaction monitoring (SRM) mode, by identifying the putative kinetin and kinetin riboside based on their characteristic fragments. Based on a signal-to-noise ratio of 3, the limits of detection in SRM mode were 0.02 microM and 0.005 microM for kinetin and kinetin riboside, respectively. Furthermore, optimal conditions for a baseline chromatographic separation of 18 cytokinin standards by high performance liquid chromatography (HPLC) were developed. The HPLC method had been employed for the confirmation and further fractionation of kinetin in coconut water extracts. The confirmation and fractionation of kinetin riboside was carried out using a further modified HPLC program due to the presence of other interfering material(s) in the sample matrix. Finally, fractions of putative kinetin and kinetin riboside collected from HPLC eluate of coconut water sample were further authenticated by independent capillary zone electrophoresis (CZE) experiment.

Chromatography, High Pressure Liquid↗

Selective quantitative bioanalysis of proteins in biological fluids by on-line immunoaffinity chromatography-protein digestion-liquid chromatography-mass spectrometry.

A quantitative method for the determination of proteins in complex biological matrices has been developed based on the selectivity of antibodies for sample purification followed by proteolytic digestion and quantitative mass spectrometry. An immunosorbent of polyclonal anti-bovine serum albumin (BSA) antibodies immobilized on CNBR agarose is used in the on-line mode for selective sample pretreatment. Next, the purified sample is trypsin digested to obtain protein specific peptide markers. Subsequent analysis of the peptide mixture using a desalination procedure and a separation step coupled, on-line to an ion-trap mass spectrometer, reveals that this method enables selective determination of proteins in biological matrices like diluted human plasma. This approach enhances substantially the selectivity compared to common quantitative analysis executed with immunoassays and colorimetry, fluorimetry or luminescence detection. Hyphenation of the immunoaffinity chromatography with on-line digestion and chromatography-mass spectrometry is performed and a completely on-line quantification of the model protein BSA in bovine and human urine was established. A detection limit of 170 nmol/l and a quantification limit of 280 nmol/l is obtained using 50 microl of either standard or spiked biological matrix. The model system allows fully automated absolute quantitative mass spectrometric analysis of intact proteins in biological matrices without time-consuming labeling procedures.

Animals↗

Comparison of liquid chromatography with fluorescence detection to liquid chromatography-mass spectrometry for the determination of fluoxetine and norfluoxetine in human plasma.

A comparison study on fluoxetine (FL) and norfluoxetine (NORFL) quantitation in human plasma was carried out between the recently developed liquid chromatographic method with fluorescence detection (LC-FLD) and an earlier established liquid chromatography-mass spectrometry (LC-MS) laboratory procedure. Comparative method evaluation was based on the analysis of plasma samples obtained from Parkinsonian patients receiving 20mg of FL per day. The LC-FLD method involves a two-step liquid extraction procedure without any derivatization, followed by direct chromatography on a Zorbax C8 reversed-phase column. The analytical results are discussed in terms of the method validation and the corresponding experimental protocol (r>/=0.998; CV<9%; LOQ 20 microg/l). There was good correlation between FL, as well as NORFL, plasma levels as determined by the LC-MS and LC-FLD techniques (r=0.9597, N=16 and r=0.9852, N=14 for FL and NORFL, respectively). The results confirm that direct FL/NORFL fluorimetric determination is acceptable for routine use in pharmacokinetic and clinical studies.

Calibration↗

Improved performance of column chromatography by arginine: dye-affinity chromatography.

Arginine has been effectively used in various column chromatographies for improving recovery and resolution, and suppressing aggregation. Here, we have tested the effectiveness of arginine as an eluent in dye-affinity column chromatography using Blue-Sepharose, which binds enzymes requiring adenyl-containing cofactors (e.g., NAD). A common eluent, NaCl, showed a broad elution peak with low recovery of lactate dehydrogenase, at most approximately 60% using 2M salt. The recovery decreased as the NaCl concentration was either decreased or increased; i.e., the recovery was maximum at 2M. On the contrary, addition of arginine to the eluent resulted in more than 80% recovery above 0.5M and the recovery was nearly independent of the arginine concentration. The elution peak was much sharper with arginine, leading to elution of more concentrated protein solution. Successful elution of proteins bound to the ATP-agarose resins by arginine was also described.

Arginine↗

Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of peptides.

Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF than reversed-phase packings that is scarcely dependent on the pH of the eluent. Applying a potential in gradient elution reversed-phase nano-LC of peptides shortens the analysis time as compared to separations without a potential. Electrically assisted reversed-phase gradient elution nano-LC is a powerful separation tool for analysis of tryptic digests. Peptides can be successfully resolved in acidic organic mobile phase at pH 2-3 with and without trifluoroacid as ion pairing reagent under isocratic conditions. It is demonstrated that CEC with mixed mode packing and an eluent of pH 2.3 with varying acetonitrile content can be applied to monitor impurities in a synthetic peptide.

Chromatography, High Pressure Liquid↗

Retention behaviour of ceramides in sub-critical fluid chromatography in comparison with non-aqueous reversed-phase liquid chromatography.

This study was devoted to the development of an analytical method for ceramide analysis in packed subcritical fluid chromatography (pSubFC). Monofunctional grafted silica support was found to be more suitable for ceramide analysis. Five Kromasil columns were coupled and the parameters, temperature, pressure and percentage of organic modifier in CO2 were optimised, considering selectivity and analysis time. The final conditions were 31 degrees C, 6% of methanol (MeOH) and 13 MPa. In these conditions the selectivity for structural differences (methylene group, unsaturation or two different bases) were studied. As classically observed, the methylene selectivity decreased with the increase of the eluotropic strength. Moreover, unlike in non-aqueous reversed-phase liquid chromatography (NARP-LC), adding a further unsaturation and two further methylene groups on ceramide results to an increase of retention in pSubFC. Moreover, this last technique allowed to separate ceramides with the same total number of carbons containing unsaturated fatty acids, when the distribution of carbon number of the two chain is very different. These results had enabled to plot retention chart in order to predict ceramide structure in view to identify additional ceramide. This retention chart was finally compared with the one already obtained in NARP-LC.

Ceramides↗

Enantioseparations in counter-current chromatography and centrifugal partition chromatography.

Examples of chiral separations in counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) are not numerous, due to the difficulty of finding chiral selectors highly selective in the liquid phase as well as a combination of solvents that does not destroy the selectivity and retains the capacity to elute chiral isomers of interest. New ideas and new chiral selectors generally come from other separation techniques, as will be highlighted in this review.

Chromatography, Liquid↗