Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Blood Specimen Collection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Cordocentesis.

Explore the source record for details and available documents.

Anemia↗

Effective measures for reducing blood loss from diagnostic laboratory tests in intensive care unit patients.

We studied ICU patient blood loss as a result of diagnostic testing (DBL) and the effect of two measures to reduce it. A policy of using small volumes (pediatric phlebotomy tubes, reduced syringe volumes) for the most frequent laboratory tests was implemented in our medical ICU. We prospectively studied 151 patients admitted during two consecutive 10-wk periods. During period 2, DBL was displayed on each ICU flow sheet. The DBL/day (43.6 +/- 3 [SEM] ml) was significantly lower (62.6 +/- 4 ml) than it would have been if standard volume tubes had been used. This represented an average savings of 33%. During period 1 (n = 81), eight (10%) patients with no diagnosis involving blood loss had a decrease in Hct and received transfusion. DBL was significantly higher (316 +/- 81 vs. 168 +/- 18 ml, p less than .001) for these patients and represented an average of 17% of transfusion requirements. During period 2 (n = 70), such transfusion requirements were significantly reduced (only one of 70, p less than .001), as were tests ordered/day (7.8 +/- 0.5 vs. 9.5 +/- 0.6, p less than .05). We conclude that DBL is a major health problem for the ICU patient. Routine use of small specimen volumes in this setting is warranted. Recording DBL for use in physician decision-making also significantly impacts this problem and should be considered an important part of the ICU database.

Blood Specimen Collection↗

A clinical evaluation of a blood conservation device in medical intensive care unit patients.

OBJECTIVES: This study was designed to a) document the efficacy of a device intended to conserve blood in critically ill patients; b) determine the effect of this blood conservation on hemoglobin concentration and the need for blood transfusions; c) determine if the blood conservation device resulted in interference with arterial pressure waveforms; d) determine if use of the blood conservation device resulted in a difference in the number of accidental needle punctures suffered by healthcare workers. DESIGN: Prospective, randomized, controlled trial. A clinical trial using prospective, random allocation of consecutive eligible patients. SETTING: The medical intensive care unit (ICU) of a university hospital located in a large metropolitan area. PATIENTS: A total of 100 patients who were admitted to the medical ICU, required arterial line monitoring for clinical purposes, and were managed by the ICU medical service. Exclusion criteria included active bleeding or chronic renal failure at the time of ICU admission. INTERVENTIONS: Patients in the experimental group had a blood conservation device incorporated into the arterial pressure monitoring system, while patients in the control group received a conventional arterial pressure monitoring system. MEASUREMENTS AND MAIN RESULTS: Data gathered included: age; gender; ICU discharge status; the duration of ICU stay; time in the study; volume of all blood drawn, discarded, or lost due to leakage; hemoglobin concentrations; blood transfusions; and accidental needle injuries. Arterial pressure waveforms were recorded and inspected for dampening or other deformation. Mean hemoglobin concentrations were compared on ICU admission and at 12-hr intervals. Demographic and clinical characteristics of the two groups were not significantly different. The volume of blood drawn and discarded from arterial catheters was significantly lower in the blood conservation group (blood conservation device: 5.7 +/- 7.5 mL; control: 96.4 +/- 88.5 mL; p < .0001), as was the total volume of blood discarded (blood conservation device: 19.4 +/- 47.4 mL; control: 103.5 +/- 99.9 mL; p < .0001). Mean hemoglobin concentration on admission was similar in the two groups (blood conservation device group: 11.8 +/- 2.5 g/dL; control group: 12.6 +/- 2.3 g/dL). In both groups, the mean hemoglobin concentration declined most rapidly in the first 24 hrs of ICU care and, thereafter, declined more slowly. Although the mean hemoglobin concentration was higher in the blood conservation group after 6 days, statistical significance was not reached until 9.5 days of ICU care. The mean change in hemoglobin concentration (overall: 1.2 +/- 2.2 g/dL) during the study represents a statistically significant (p < .0001) decrease of 9.7%. Hemoglobin concentration during the study decreased by 1.4 +/- 2.2 g/dL in the control group and 1.0 +/- 2.3 g/dL in the blood conservation group (p = nonsignificant). Univariate and multiple regression analysis demonstrated discarded blood volume to be a significant and independent predictor of the decline in hemoglobin concentration. Transfusion requirements were similar in both groups. The blood conservation system did not alter or interfere with pressure waveforms. There were no accidental needle injuries noted. CONCLUSIONS: The conservation of blood in critically ill patients must be a high-priority concern of all healthcare workers. Our data indicate that the blood conservation system eliminates a significant factor in the decline in hemoglobin concentration. With devices as described here, there is no reason to continue the practice of wasting the blood of critically ill patients in order to prevent preanalytic error.

Adult↗

Blood conservation strategies in cardiovascular surgery.

Blood conservation is a measurable intervention in which clinical and financial outcomes may be tracked. This article describes a systems approach to blood conservation for a cardiac surgery population. Four key areas are discussed: needs assessment, committee construction, blood conservation strategies, and outcome measurement. Specific evidenced-based blood conservation strategies include, but are not limited to, transfusion risk index, phlebotomy techniques, management of hemostasis and hemoglobin levels which includes blood testing, pharmacologic agents, and blood transfusion prescription guidelines.

Blood Loss, Surgical↗

HIV seroprevalence in hospital patients in rural Georgia.

To determine human immunodeficiency virus (HIV) seroprevalence among hospital patients in three rural community-based hospitals in southern Georgia, we anonymously tested patients 15 to 54 years old for antibodies to HIV-1 from residual blood specimens collected for routine diagnostic purposes. Data collected included age, sex, race, hospital service, presenting condition, physician's knowledge of HIV infection status, and discharge diagnosis. Of 1319 patients tested, seven (0.5%, 95% confidence interval = 0.2% to 1.1%) had antibodies to HIV-1. Of those seven, five had HIV infection unsuspected by their physicians, and four had an infectious disease. HIV seroprevalence was 0.5% for both men and women, 1.0% for blacks, and 0.3% for whites. HIV-positive patients were found on all hospital services. These results suggest that in rural southern Georgia hospitals, HIV should be routinely considered in the differential diagnosis of conditions that may be related to HIV. In addition, these data demonstrate a need for medical services or referral networks for HIV-related illnesses and a need for continuing HIV counseling and testing offered by local health departments in rural southern Georgia.

Adolescent↗

Nursing strategies to minimize blood loss associated with phlebotomy.

Blood loss associated with phlebotomy is significant in critically ill adults. Iatrogenic anemia may result and impose unnecessary stress on the cardiovascular and respiratory systems and may require allogeneic blood transfusions. Many strategies exist under nursing's direct control to decrease blood loss associated with phlebotomy. In the past, nursing effectively implemented many of these strategies in patients at high risk of anemia, such as pediatric, neonatal, transplant, or chronic renal failure patients, as well as patients who are Jehovah's Witnesses. Implementation of these strategies are needed for all critically ill patients because allogeneic blood transfusions carry infectious risk and because complications and chronic critical illness cannot be predicted reliably. Incorporation of these strategies into daily practice as well as the development of blood conservation programs represent imminent challenges for nursing.

Adult↗

Early diagnosis of HIV-1-infected infants in Thailand using RNA and DNA PCR assays sensitive to non-B subtypes.

OBJECTIVES: To evaluate the sensitivity and specificity of RNA and DNA polymerase chain reaction (PCR) for early diagnosis of perinatal HIV-1 infection and to investigate early viral dynamics in infected infants. DESIGN: A cohort study of 395 non-breastfed infants born to HIV-infected mothers in a randomized clinical trial of short-course antenatal zidovudine. METHODS: Infant venous blood specimens collected at birth, 2 months, and 6 months of age were tested by qualitative DNA and quantitative RNA PCR (Roche Amplicor). To determine sensitivity and specificity of DNA and RNA PCR, results were compared with later DNA PCR results and to antibody results at 18 months. The HIV-1 subtype of the mother's infection was determined by peptide serotyping. RESULTS: In the study, 92% of mothers were infected with subtype E. DNA PCR sensitivity was 38% (20 of 53) at birth, and 100% at 2 months (53 of 53) and 6 months (47 of 47). RNA PCR sensitivity was 47% (25 of 53) at birth and 100% (53 of 53) at 2 months. All samples that tested DNA-positive tested RNA-positive. Specificity was 100% for both DNA and RNA testing at all timepoints. For infected infants, the median viral load of RNA-positive specimens was 407,000 copies/ml (5.6 log10) at birth, 3, 700,000 copies/ml (6.6 log10) at 2 months, and 1,700,000 copies/ml (6.2 log10) at 6 months. Infant RNA levels at 2 and 6 months did not differ by maternal zidovudine exposure, or RNA level at birth. CONCLUSION: This RNA PCR assay performed well for diagnosing perinatal HIV subtype E infection, detecting nearly half of infected infants at birth, and 100% at 2 and 6 months, with 100% specificity. Infected infant viral RNA levels were very high at 2 and 6 months, and were unaffected by maternal zidovudine treatment.

Age Factors↗

HIV sentinel surveillance among women seeking elective pregnancy termination, San Francisco.

OBJECTIVE: The objective of this study was to measure HIV prevalence, HIV incidence, and risk factors for infection among women seeking elective pregnancy termination in San Francisco. STUDY: The authors conducted a cross-sectional survey comprising a consecutive sample of women seeking elective pregnancy termination in San Francisco's county hospital from August 2002 to July 2003. Demographic and risk behavior information was abstracted from routine clinic records. HIV testing was conducted on blood specimens collected for other purposes after removing identifying information. RESULTS: Based on 11 HIV-positives among 1,992 tested, HIV prevalence among women seeking pregnancy termination was 0.55% (95% confidence interval [CI], 0.28-0.99). One recent HIV seroconversion was detected for an annual incidence of 0.11% per year (95% CI, 0.23-0.88). In addition, risk factors significantly associated with HIV infection included sex with a known HIV-positive man, history of an abnormal Pap smear, history of genital herpes infection, history of trichomoniasis, and age 25 to 29 years. CONCLUSIONS: Women electing pregnancy termination can serve as a sentinel population to track trends in the HIV epidemic. However, barriers remain to wider implementation of the approach as a surveillance tool.

Abortion, Induced↗

Poststorage leuko-depleted plasma inhibits T-cell proliferation and Th1 response in vitro: characterization of TGFbeta-1 as an important immunomodulatory component in stored blood.

BACKGROUND: Poststorage, leuko-depleted blood transfusions have been associated with increased postoperative infections and improved allograft survival compared with prestorage leukocyte-depleted blood transfusion. Although the mechanism of this phenomenon remains to be fully elucidated, it is clear that the immunomodulatory effect is mediated by leukocytes/platelets or their products. METHOD: The aim of this study was to investigate the in vitro effects of pre- and poststorage leuko-depleted plasma (LDP) and buffy coat LDP on T-cell proliferation and cytokine synthesis using multiparameter flow cytometry. RESULTS: In cell cultures exposed to prestorage LDP and buffy coat LDP there were no significant changes compared with fresh blood. In cell cultures exposed to poststorage LDP, T-cells showed reduced expression of CD69, CD25 (IL-2Ralpha), CD122 (IL-2Rbeta) and CD132 (IL-2Rtau) and production of TNF-alpha and IL-2 but there was no significant alteration for IFN-tau or IL-4. Changes in cytokine/cytokine receptor synthesis and T-cell proliferation were shown to be directly proportional to poststorage LDP concentration. Some of these changes were characteristic of TGFbeta-1. Addition of TGFbeta-1 neutralising antibody to poststorage LDP, negated the immunosuppressive effect on PHA-stimulated PBMC cultures. CONCLUSIONS: The decrease in T-cell proliferation and Th1 cytokines TNF-alpha and IL-2, may be one basis of altered immunoregulation resulting in increased rates of certain types of infections and increased graft tolerance reported in patients receiving poststorage LD blood transfusions. TGFbeta-1 is a major immunomodulatory component of poststorage LD blood transfusions.

Apoptosis↗

New technology for transfusion safety.

Hemovigilance programs from around the world document that the greatest risk to recipients of blood transfusion is human error, resulting in transfusion of the incorrect blood component. Errors in transfusion care have strong parallels with errors in medication administration. Errors often result from 'lapse' or 'slip' mistakes in which details of patient identification are overlooked. Three areas of transfusion are focal points for improved care: the labelling of the patient's pre-transfusion sample, the decision to transfuse and the final bedside check designed to prevent mis-transfusion. Both barcodes and radio-frequency identification technology, each ideally suited to matching alpha-numeric identifiers, are being implemented in order to improve performance sample labelling and the bedside check. The decision to transfuse should ultimately be enhanced through the use of nanotechnology sensors, computerised order entry and decision support systems. Obstacles to the deployment of new technology include resistance to change, confusion regarding the best technology, and uncertainty regarding the return-on-investment. By focusing on overall transfusion safety, deploying validated systems appropriate for both medication and blood administration, thoughtful integration of technology into bedside practice and demonstration of improved performance, the application of new technologies will improve care for patients in need of transfusion therapy.

Blood Grouping and Crossmatching↗

Production of additional atypical alloantibodies in Rh(D)-sensitized pregnancies managed by intrauterine investigation methods.

The production of additional atypical alloantibodies by previously Rh(D)-alloimmunized antenatal patients can complicate the clinical management of both mother and fetus. The relative risks of stimulating additional antibodies following the use of intrauterine investigation methods currently used for the management of haemolytic disease of the newborn have been assessed. A significantly (P less than 0.05, X2) greater number of additional antibodies were detected during pregnancy in the group of pregnancies managed by intrauterine transfusion (IUT) (3/29) than in those managed without recourse to intrauterine investigation (0/50), although one of the patients in the IUT group produced a further antibody following a fetal blood sample but before an IUT had been carried out. The number of additional antibodies detected post-delivery was significantly greater (P less than 0.02) in pregnancies managed by intrauterine transfusion (2/10) than in those managed by fetal haematocrit determination alone (0/28).

Blood Specimen Collection↗

Bacterial risk reduction by improved donor arm disinfection, diversion and bacterial screening.

The Interventions of improved donor arm disinfection, diversion and bacterial screening have been implemented by blood services and shown to have substantial benefit. The major source of bacterial contamination is donor arm derived. Blood services are now introducing best practice donor arm disinfection techniques. Diversion has been shown to substantially reduce bacterial contamination in the order of 40-88%. Diversion, together with improved donor arm disinfection, has shown to improve the percentage of reduction in contamination from 47% to 77%. Residual contamination levels after the Introduction of diversion and improved donor arm disinfection may be in the order of 30-40%. Numerous countries have now implemented screen testing programmes for platelet concentrates, which are the major source of bacterial transfusion transmission. Pathogen reduction systems have been developed and are under development. At present, concerns remain with these systems regarding cost, process control, ability to inactivate high titres of viruses, killing of bacterial spores, product damage, genotoxicity and mutagenicity. The interventions of diversion, improved donor arm disinfection and bacterial screen testing are currently available, As such they can be implemented now to increase blood safety with no associated patient risk.

Blood Donors↗

Influence of blood-taking procedure on the heart function of blood donors.

The systolic time intervals and heart rate were studied in 11 blood-donors aged between 20 and 48 years by a non-invasive technique before and after the usual blood-taking procedure. No statistically significant difference was found between values determined before and after the procedure. A significant correlation (r = 0.76) was demonstrated between percent changes of pre-ejection period/left ventricular ejection time (PEP/LVET)-ratio and withdrawn volume of blood (450 ml) X time (min)-1 X bodyweight (kg)-1. No correlation was found between percent changes of PEP/LVET-ratio and withdrawn volume of blood X time-1, nor between percent changes of PEP/LVET-ratio and withdrawn volume of blood X percentage of circulatory volume removed-1. It is suggested that the blood-taking time (in minutes) should not be shorter than the quotient: donated volume of blood (ml) X bodyweight (kg)-1 if a negative influence of withdrawal procedure on left ventricular function is to be avoided. Mechanisms contributing to circulatory stability during reduction of blood volume are briefly discussed.

Adult↗