Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “deconvolution”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Handling non-negativity in deconvolution of physiological signals: a nonlinear stochastic approach.

A stochastic interpretation of Tikhonov regularization has been recently proposed to attack some open problems of deconvolution when dealing with physiological systems, i.e., in addition to ill-conditioning, infrequent and nonuniform sampling and necessity of having credible confidence intervals. However, the possible violation of the non-negativity constraint cannot be dealt with on firm statistical grounds, since the model of the unknown signal is compatible with negative realizations. In this paper, we propose a new model of the unknown input which excludes negative values. The model is embedded within a Bayesian estimation framework to calculate, by resorting to a Markov chain Monte Carlo algorithm, a nonlinear estimate of the unknown input given by its a posteriori expected value. Applications to simulated and real hormone secretion/pharmacokinetic problems are presented which show that this nonlinear approach is more accurate than the linear one. In addition, more realistic confidence intervals are obtained.

Algorithms↗

Removal of image intensifier veiling glare by mathematical deconvolution techniques.

X-ray images acquired with an image intensifier detector system suffer from veiling glare, a low-frequency degradation described by a point spread function (PSF). The PSF has two experimentally determined parameters unique to a given image intensifier. This information is utilized to deconvolve the degradation from digitally acquired images. Results demonstrate a significant increase in contrast ratio of high-contrast objects after deconvolution and image restoration.

Animals↗

Deconvolution techniques for removing the effects of chemical shift in 19F nuclear magnetic resonance imaging of perfluorocarbon compounds.

Nuclear magnetic resonance (NMR) imaging of perfluorocarbon (PFC) emulsions and neat liquids has shown potential for in vivo oxygen imaging in blood and organ tissue. PFC compounds exhibit complicated NMR spectra caused by chemical shifts and spin-spin couplings which can lead to artifacts and degraded spatial resolution of resulting NMR images. To correct for the chemical shift artifacts, the technique of spectral deconvolution has been applied to NMR imaging of PFC compounds. The temporal filter for this process can be directly applied to raw free induction decay data in projection reconstruction or to spin-echo data in two-dimensional Fourier transform imaging techniques. The effect of chemical shift artifacts was demonstrated through the NMR imaging of two PFC compounds (F-tributylamine and F-decalin) in phantoms. Methods are presented and demonstrated which allow the chemical shift artifacts to be removed and true images of the spatial distribution of the PFC's to be recovered.

Blood Substitutes↗

X-ray scatter removal by deconvolution.

The distribution of scattered x rays detected in a two-dimensional projection radiograph at diagnostic x-ray energies is measured as a function of field size and object thickness at a fixed x-ray potential and air gap. An image intensifier-TV based imaging system is used for image acquisition, manipulation, and analysis. A scatter point spread function (PSF) with an assumed linear, spatially invariant response is modeled as a modified Gaussian distribution, and is characterized by two parameters describing the width of the distribution and the fraction of scattered events detected. The PSF parameters are determined from analysis of images obtained with radio-opaque lead disks centrally placed on the source side of a homogeneous phantom. Analytical methods are used to convert the PSF into the frequency domain. Numerical inversion provides an inverse filter that operates on frequency transformed, scatter degraded images. Resultant inverse transformed images demonstrate the nonarbitrary removal of scatter, increased radiographic contrast, and improved quantitative accuracy. The use of the deconvolution method appears to be clinically applicable to a variety of digital projection images.

Computer Simulation↗

Deconvolution of detector size effect for small field measurement.

Parametrization of the small fields employed in stereotactic applications is a painstaking process involving extensive film dosimetry to achieve acceptable beam edge definition. Use of cylindrical or spherical detectors for profile measurements would simplify data acquisition but add a volume averaging artifact to beam edge definition. We demonstrate a simple approach to unfolding the chamber size artifact from measured small beam profiles using typical cylindrical chambers. In comparison with film measurements we have found good agreement when the detector response function is deconvoluted from the measured profiles, although the amount of correction needed is fairly minimal for the detectors studied.

Film Dosimetry↗

Inverse radiosurgery treatment planning through deconvolution and constrained optimization.

An inverse radiosurgery treatment planning approach is presented which calculates conformal dose distributions for small, irregularly shaped targets. Two general approaches have been suggested for solution of the inverse radiotherapy problem: explicit and implicit. Explicit methods are typically fast, but generally require geometric and/or dosimetric simplifications. Implicit methods have also been used, but are computationally expensive because they require iterative manipulation of each beam's individual elements. The method presented here incorporates an integrated approach in order to efficiently solve the inverse problem without requiring simplifications which may affect the accuracy of the final result. A deconvolution algorithm (explicit approach) is utilized to determine the intensity modulation function for multiple user-selected beam's eye views of the desired dose distribution. A simulated annealing algorithm (implicit approach) then optimizes each beam's macroscopic weight. Additionally, this method is fully three-dimensional and accurately models phantom scatter by incorporating Monte Carlo generated energy deposition kernels into the dosimetry process. Several small target structure examples are presented and applicability of this methodology to larger targets for general radiotherapy cases is addressed.

Algorithms↗

Synthetic aperture imaging using sources with finite aperture: deconvolution of the spatial impulse response.

A method for ultrasonic synthetic aperture imaging using finite-sized transducers is introduced that is based on a compact, linear, discrete model of the ultrasonic measurement system developed using matrix formalism. Using this model a time-domain algorithm for deconvolution of the transducer's spatial impulse responses (SIRs) is developed that is based on a minimum mean square error (MMSE) criterion. The algorithm takes the form of a spatiotemporal filter that compensates for the SIRs associated with a finite-sized transducer at every point of the processed image. A major advantage of the proposed method is that it can be used for any transducer, provided that its associated SIRs are known. This is in contrast to the synthetic aperture focusing technique (SAFT), which treats the transducer as a point source. The performance of the method is evaluated with simulations and experiments, performed in water using a linear phased array. The results obtained using the proposed method are compared to those obtained with a classical time-domain SAFT algorithm. For a finite aperture source, it is clearly shown that the resolution obtained using the proposed method is superior to that obtained using the SAFT algorithm.

Journal Article↗

Deconvolution of evoked responses obtained at high stimulus rates.

Continuous loop averaging deconvolution (CLAD) is a new general mathematical theory and method developed to deconvolve overlapping auditory evoked responses obtained at high stimulation rates. Using CLAD, arbitrary stimulus sequences are generated and averaged responses deconvolved. Until now, only a few special stimulus series such as maximum length sequences (MLS) and Legendre sequences (LGS) were capable of performing this task. A CLAD computer algorithm is developed and implemented in an evoked potential averaging system. Computer simulations are used to verify the theory and methodology. Auditory brainstem responses (ABR) and middle latency responses (MLR) are acquired from subjects with normal hearing at high stimulation rates to validate and show the feasibility of the CLAD technique.

Acoustic Stimulation↗

An improvement in the range resolution of ultrasonic pulse echo systems by deconvolution.

Ultrasonic pulse echo systems are often limited in range resolution by the bandwidth of the piezoelectric transducer. Significant improvements in the range resolution of such systems can be obtained by minimizing the effects of the transducer's dynamic response on the overall pulse echo process. An approach to minimize the effects of the transducer is developed from linear system and impulse response techniques. In essence, the pulse echo voltage of interest is deconvolved with a pulse echo reference voltage which is obtained from an air/water interface in the nearfield of the transducer . A computer study of the pulse echo process and the deconvolution process is presented to illustrate the nature of the improvement in range resolution for several cases of interest. Finally, experimental results are presented to illustrate the improvement using commercially available transducers.

Transducers↗

Performance of some sparseness criterion blind deconvolution methods in the presence of noise

A comparison of the spareseness (simplicity) norm criterion blind deconvolution methods of Cabrelli and Wiggins is made in order to ascertain relative performance for underwater acoustic transient source signal estimation, especially in the presence of noise. Both methods perform well at high signal-to-noise ratios, producing source estimates that are significant improvements over the original received signal for classification purposes. At moderate and lower SNRs, the Cabrelli method tends to generate results that are superior to the Wiggins method. This is especially true for a damped sinusoid transient source, for which the Wiggins method fails completely at lower SNRs, while the Cabrelli method can still produce good source estimates.

Journal Article↗

Maximum a posteriori deconvolution of ultrasonic signals using multiple transducers

A new method for deconvolution of ultrasonic pulse-echo measurements employing multiple-transducer setup is proposed in the paper. An optimal way of estimating the material reflection sequence for a linear signal generation model using maximum a posteriori estimation is proposed. The method combines the measurements from a number of transducers covering different frequency bands yielding an optimal estimate of the reflection sequence. The main idea of this approach is to complement the information unavailable from one transducer in some frequency bands with the information from the other transducers. The method is based on the assumption that the measurements are performed using transducers with identical apertures and apodization, which are located exactly at the same position relative to the test object during the measurement. An error analysis presented in the paper proves that when the above assumptions are fulfilled, the proposed method, by utilizing more data for estimation, consistently yields more accurate reflection sequence estimates than the classical Wiener filter. Experimental evidence is presented using both simulated and real ultrasonic data as a verification of the correctness of the multiple-transducer model and the estimation scheme. An illustration of the advantages of the method is also given using real ultrasonic data.

Journal Article↗

A simple sequential incubation method for deconvoluting the complicated sequential metabolism of capravirine in humans.

Capravirine, a non-nucleoside reverse transcriptase inhibitor for the treatment of human immunodeficiency virus type 1, undergoes extensive oxygenations to numerous sequential metabolites in humans. Because several possible oxygenation pathways may be involved in the formation and/or sequential metabolism of a single metabolite, it is very difficult or even impossible to determine the definitive pathways and their relative contributions to the overall metabolism of capravirine using conventional approaches. For this reason, a human liver microsome-based "sequential incubation" method has been developed to deconvolute the complicated sequential metabolism of capravirine. In brief, the method includes three fundamental steps: 1) 30-min primary incubation of [(14)C]capravirine, 2) isolation of (14)C metabolites from the primary incubate, and 3) 30-min sequential incubation of each isolated (14)C metabolite supplemented with an ongoing (30 min) microsomal incubation with nonlabeled capravirine. Based on the extent of both the disappearance of the isolated precursor (14)C metabolites and the formation of sequential (14)C metabolites, definitive oxygenation pathways of capravirine were assigned. In addition, the percentage contribution of a precursor metabolite to the formation of each of its sequential metabolites (called sequential contribution) and the percentage contribution of a sequential metabolite formed from each of its precursor metabolites (called precursor contribution) were determined. An advantage of this system is that the sequential metabolism of each isolated (14)C metabolite can be monitored selectively by radioactivity in the presence of all relevant metabolic components (i.e., nonlabeled parent and its other metabolites). This methodology should be applicable to mechanistic studies of other compounds involving complicated sequential metabolic reactions when radiolabeled materials are available.

Biotransformation↗

Growth hormone secretory rates in children as estimated by deconvolution analysis of 24-h plasma concentration profiles.

The kinetics of growth-hormone (GH) distribution and elimination was estimated in five GH-deficient children who received 11 intravenous single injections of GH. The plasma disappearance data were analyzed in terms of a two-compartment model. The kinetic parameters obtained were then used in calculating the GH-secretory rate by a numerical deconvolution technique. A simple formula was derived for calculation of the cumulated secretion from the area under the concentration curve of 145 healthy children of various ages, heights, and stages of puberty. The estimated 24-h GH secretion increased with age, corresponding to a two- to fourfold increase during the adolescence period. The highest secretions were found in pubertal stages 3-4. In prepubertal children the heights correlated markedly with the secretion of GH (r = 0.83). Thus an indication of the range of the GH secretion in normal growing children is found, which is important to estimate substitution doses for treatment of GH-deficient children.

Activity Cycles↗

Nocturnal growth hormone secretory dynamics are altered after resistance exercise: deconvolution analysis of 12-hour immunofunctional and immunoreactive isoforms.

To characterize the effects of daytime exercise on subsequent overnight growth hormone (GH) secretion and elimination dynamics, serum was sampled, and GH was measured every 10 min for 12 h (1800 to 0600) in a control (CON) condition and after a 50-set resistance exercise protocol (EX) from 1500 to 1700. GH was measured with a conventional immunoreactive (IR) and an immunofunctional (IF) assay, and values were analyzed via a multi-parameter deconvolution analysis. EX resulted in a higher overnight secretory burst frequency [CON: 7.6 (SD 2.4) < EX: 9.4 (2.2) bursts per 12 h, P = 0.005] but lower mean burst mass [CON: 9.2 (4.7) > EX: 6.0 (2.9) microg/l, P = 0.019] and secretory rate [CON: 0.68 (0.29) > EX: 0.48 (0.23) microg/l/min; P = 0.015; ANOVA main effect means presented]. Approximate entropy (ApEn) was greater after EX, indicating a less orderly GH release process than CON. The estimated half-life of IF GH was significantly lower than IR GH [IF: 15.3 (1.1) < IR 19.8 (1.6) min, P < 0.001] but similar between the CON and EX conditions (approximately 17 min). Despite the changes in secretory dynamics, 12-h mean and integrated GH concentrations were similar between conditions. The results suggest that although quantitatively similar total amounts of GH are secreted overnight in CON and EX conditions, resistance exercise alters the dynamics of secretion by attenuating burst mass and amplitude yet increasing burst frequency.

Adaptation, Physiological↗

Estimation of growth hormone secretory patterns in children with use of a numerical deconvolution technique: experimental design with use of computer simulation.

Growth hormone (GH) secretion rates were estimated from 24-hour plasma GH concentration profiles using a model-based numerical deconvolution method. The basic kinetic parameters describing GH distribution and elimination were obtained from studies using single intravenous injections in GH-deficient children. Computer simulation techniques were used to produce 24-hour GH secretion profiles, which could serve as reference curves for analysis of the impact of certain practical aspects of the estimation of GH secretion, such as the method of blood sampling (discrete or integrated), sampling frequency and analytical errors. The results show that sampling intervals of 20 min are acceptable even in the presence of analytical errors, and that with this sampling interval, discrete blood sampling does not seem to be preferable to continuous withdrawal of blood.

Blood Specimen Collection↗

Deconvolution of event-related fMRI responses in fast-rate experimental designs: tracking amplitude variations.

Recent developments towards event-related functional magnetic resonance imaging has greatly extended the range of experimental designs. If the events occur in rapid succession, the corresponding time-locked responses overlap significantly and need to be deconvolved in order to separate the contributions of different events. Here we present a deconvolution approach, which is especially aimed at the analysis of fMRI data where sequence- or context-related responses are expected. For this purpose, we make the assumption of a hemodynamic response function (HDR) with constant yet not predefined shape but with possibly variable amplitudes. This approach reduces the number of variables to be estimated but still keeps the solutions flexible with respect to the shape. Consequently, statistical efficiency is improved. Temporal variations of the HDR strength are directly indicated by the amplitudes derived by the algorithm. Both the estimation efficiency and statistical inference are further supported by an improved estimation of the noise covariance. Using synthesized data sets, both differently shaped HDRs and varying amplitude factors were correctly identified. The gain in statistical sensitivity led to improved ratios of false- and true-positive detection rates for synthetic activations in these data. In an event-related fMRI experiment with a human subject, different HDR amplitudes could be derived corresponding to stimulation at different visual stimulus contrasts. Finally, in a visual spatial attention experiment we obtained different fMRI response amplitudes depending on the sequences of attention conditions.

Algorithms↗

An information-maximization approach to blind separation and blind deconvolution.

We derive a new self-organizing learning algorithm that maximizes the information transferred in a network of nonlinear units. The algorithm does not assume any knowledge of the input distributions, and is defined here for the zero-noise limit. Under these conditions, information maximization has extra properties not found in the linear case (Linsker 1989). The nonlinearities in the transfer function are able to pick up higher-order moments of the input distributions and perform something akin to true redundancy reduction between units in the output representation. This enables the network to separate statistically independent components in the inputs: a higher-order generalization of principal components analysis. We apply the network to the source separation (or cocktail party) problem, successfully separating unknown mixtures of up to 10 speakers. We also show that a variant on the network architecture is able to perform blind deconvolution (cancellation of unknown echoes and reverberation in a speech signal). Finally, we derive dependencies of information transfer on time delays. We suggest that information maximization provides a unifying framework for problems in "blind" signal processing.

Algorithms↗

Lateral deconvolution of ultrasonic beams.

A number of papers have appeared recently describing methods of lateral resolution improvement in ultrasonic images by deconvolution of the amplitude detected cross-beam characteristic. It is the intention of this paper to demonstrate that such methods of resolution improvement are appropriate only for a limited class of targets. In general, the effect of interference between the r.f. signals from multiple targets at differing distances is such that the amplitude beam width obtained for these targets cannot be considered as the linear combination of shifted replicas of the amplitude beam width for an individual target. This is a consequence of the non-linear character of the detection process. In these cases the method of deconvolving the detected responses, although capable of giving reduced spot sizes, makes errors in the position of the images and is susceptible to false images and sidelobes . The phenomenon is demonstrated with computer and experimental data on point targets.

Computers↗